Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113535, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461436

RESUMO

Measuring the time variation of the wavenumber spectrum of turbulence is important for understanding the characteristics of high-temperature plasmas, and the application of a Doppler reflectometer with simultaneous multi-frequency sources is expected. To implement this diagnostic in future fusion devices, the use of a phased array antenna (PAA) that can scan microwave beams without moving antennas is recommended. Since the frequency-scanning waveguide leaky-wave antenna-type PAA has a complex structure, we have investigated its characteristics by modeling it with 3D metal powder additive manufacturing (AM). First, a single waveguide is fabricated to understand the characteristics of 3D AM techniques, and it is clear that there are differences in performance depending on the direction of manufacture and surface treatment. Then, a PAA is made, and it is confirmed that the beam can be emitted in any direction by frequency scanning. The plasma flow velocity can be measured by applying the 3D manufacturing PAA to plasma measurement.

2.
Rev Sci Instrum ; 93(11): 113518, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461466

RESUMO

Doppler-backscattering (DBS) has been used in several fusion plasma devices because it can measure the perpendicular velocity of electron density perturbation v⊥, the radial electric field Er, and the perpendicular wavenumber spectrum S(k⊥) with high wavenumber and spatial resolution. In particular, recently constructed frequency comb DBS systems enable observation of turbulent phenomena at multiple observation points in the radial direction. A dual-comb microwave DBS system has been developed for the large helical device plasma measurement. Since it is desirable to control the gain of each frequency-comb separately, a frequency-comb DBS system was developed with a function to adjust the gain of the scattered signal intensity of each channel separately. A correction processing method was also developed to correct the amplitude ratio and the phase difference between the in-phase and quadrature-phase signals of the scattered signals. As a result, the error in Doppler-shift estimation required to observe vertical velocity and the radial electric field was reduced, which enables more precise measurements.

3.
Rev Sci Instrum ; 92(4): 043536, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243406

RESUMO

A 90 GHz W-band millimeter-wave back-scattering system is designed and installed for measuring electron scale turbulence (k⊥ρs ∼ 40). A metal lens relay antenna is used for in-vessel beam focusing, and a beam diameter of less than 40 mm is achieved in the plasma core region. This antenna can be steered at an angle of 159° ± 6°, which almost covers the plasma radius. The estimated size of the scattering volume is ∼105 mm at the edge and 135 mm at the core, respectively. A 60 m corrugated waveguide is used to achieve a low transmission loss of ∼8 dB. A heterodyne detection system for millimeter-wave circuits with probing power modulation can distinguish the scattered signal from background noise.

4.
Rev Sci Instrum ; 89(10): 10H118, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399698

RESUMO

We succeeded in increasing the radial observation points of the microwave frequency comb Doppler reflectometer system from 8 to 20 (or especially up to 45) using the high sampling rate of 40 GS/s digital signal processing. For a new acquisition system, the estimation scheme of the Doppler shifted frequency is constructed and compared with the conventional technique. Also, the fine radial profile of perpendicular velocity is obtained, and it is found that the perpendicular velocity profile is consistent with the E × B drift velocity one.

5.
Rev Sci Instrum ; 89(10): 10G120, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399783

RESUMO

A new tool has been developed to calculate the spectral, spatial, and temporal responses of multi-energy soft x-ray (ME-SXR) pinhole cameras for arbitrary plasma densities (n e,D), temperature (T e), and impurity densities (n Z). ME-SXR imaging provides a unique opportunity for obtaining important plasma properties (e.g., T e, n Z, and Z eff) by measuring both continuum and line emission in multiple energy ranges. This technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently. Simulations assuming a tangential geometry and DIII-D-like plasmas (e.g., n e,0 ≈ 8 × 1019 m-3 and T e,0 ≈ 2.8 keV) for various impurity (e.g., C, O, Ar, Ni, and Mo) density profiles have been performed. The computed brightnesses range from few 102 counts pixel-1 ms-1 depending on the cut-off energy thresholds, while the maximum allowable count rate is 104 counts pixel-1 ms-1. The typical spatial resolution in the mid-plane is ≈0.5 cm with a photon-energy resolution of 500 eV at a 500 Hz frame rate.

6.
Rev Sci Instrum ; 89(10): 10G116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399822

RESUMO

A multi-energy soft x-ray pinhole camera has been designed and built for the Madison Symmetric Torus reversed field pinch to aid the study of particle and thermal-transport, as well as MHD stability physics. This novel imaging diagnostic technique combines the best features from both pulse-height-analysis and multi-foil methods employing a PILATUS3 x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. Further improvements implemented on the new cooled systems allow a maximum count rate of 10 MHz per pixel and sensitivity to the strong Al and Ar emission between 1.5 and 4 keV. The local x-ray emissivity will be measured in multiple energy ranges simultaneously, from which it is possible to infer 1D and 2D simultaneous profile measurements of core electron temperature and impurity density profiles with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. The expected time and space resolutions will be 2 ms and <1 cm, respectively.

7.
Rev Sci Instrum ; 87(9): 093502, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782603

RESUMO

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (Te) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured Te and intensity of the signals. How accurate the values are depends on the electron temperature (Te) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high Te and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the Te in a wide Te range spanning over two orders of magnitude (0.01-1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the Te measurements are valid under harsh radiation conditions. This method to obtain Te can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

8.
Rev Sci Instrum ; 87(4): 043503, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131670

RESUMO

In TST-2 Ohmic discharges, local current is measured using a Rogowski probe by changing the angle between the local magnetic field and the direction of the hole of the Rogowski probe. The angular dependence shows a peak when the direction of the hole is almost parallel to the local magnetic field. The obtained width of the peak was broader than that of the theoretical curve expected from the probe geometry. In order to explain this disagreement, we consider the effect of sheath in the vicinity of the Rogowski probe. A sheath model was constructed and electron orbits were numerically calculated. From the calculation, it was found that the electron orbit is affected by E × B drift due to the sheath electric field. Such orbit causes the broadening of the peak in the angular dependence and the dependence agrees with the experimental results. The dependence of the broadening on various plasma parameters was studied numerically and explained qualitatively by a simplified analytical model.

9.
Rev Sci Instrum ; 85(11): 11D813, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430226

RESUMO

A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.

10.
Rev Sci Instrum ; 85(11): 11D846, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430259

RESUMO

The multi-pass Thomson scattering (TS) scheme enables obtaining many photons by accumulating multiple TS signals. The signal-to-noise ratio (SNR) depends on the accumulation number. In this study, we performed multi-pass TS measurements for ohmically heated plasmas, and the relationship between SNR and the accumulation number was investigated. As a result, improvement of SNR in this experiment indicated similar tendency to that calculated for the background noise dominant situation.

11.
Rev Sci Instrum ; 85(5): 056103, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24880428

RESUMO

In multi-pass Thomson scattering (TS) scheme, a laser pulse makes multiple round trips through the plasma, and the effective laser energy is enhanced, and we can increase the signal-to-noise ratio as a result. We have developed a coaxial optical cavity in which a laser pulse is confined, and we performed TS measurements using the coaxial cavity in tokamak plasmas for the first time. In the optical cavity, the laser energy attenuation was approximately 30% in each round trip, and we achieved a photon number gain of about 3 compared with that obtained in the first round trip. In addition, the temperature measurement accuracy was improved by accumulating the first three round trip waveforms.

12.
Rev Sci Instrum ; 83(10): 10E322, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126980

RESUMO

In order to measure the poloidal rotation velocity, a Doppler reflectometer has been developed in Large Helical Device (LHD). A remotely controlled antenna tilting system has been installed in an LHD vacuum vessel. A synthesizer is used as the source, and the operation microwave frequency ranges are ka-band and V-band. In LHD last experimental campaign we obtained the Doppler shifted signal, which was consistent with CXRS measurements.

13.
Rev Sci Instrum ; 83(2): 023507, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380091

RESUMO

This paper presents an experimental demonstration to determine electron temperature (T(e)) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T(e) can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T(e) measured from the ratio (T(e,r)) and T(e) measured from a standard method (T(e,s)) showed a good agreement with <∣T(e,r) - T(e,s)∣∕T(e,s)> = 7.3%.

14.
Rev Sci Instrum ; 81(10): 10D906, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033938

RESUMO

In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key issue of this development. For accurate phase measurement, the system utilizes a single sideband modulation technique. Currently, a dual channel heterodyne frequency hopping reflectometer system has been constructed and applied to the Alfvén eigenmode measurements.

15.
Rev Sci Instrum ; 79(10): 10F109, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044593

RESUMO

In order to measure the internal structure of fluctuation, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, is applied in the Large Helical Device. One of the important issues of density fluctuation measurements using this reflectometer is the study of energetic particle driven magnetohydrodynamics instability. During one plasma discharge, the launching frequency changes from one frequency to another frequency, which this operation is called as frequency hopping, and the cutoff position can be scanned in the wide area. As a hopping source, a synthesizer is used because it has a quite stable and low phase noise. The frequency component of the source output is multiplied to V-band (50-75 GHz) region for plasma measurements in extraordinary mode polarization. Also this system has a heterodyne detection with single side band frequency modulation for sensitive phase and amplitude measurement. We can obtain the radial profile of Alfvén eigenmodelike oscillation in a neutral beam injected plasma.

16.
Rev Sci Instrum ; 79(10): 10F120, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044604

RESUMO

A method to determine the poloidal mode number m in a spherical tokamak based on magnetic probe data was developed. Perturbed magnetic fields at Mirnov coils are calculated for distributed helical filamentary currents on rational surfaces assuming the maximum current amplitude, m and n (toroidal mode number), and the toroidal location of the filaments. These free parameters were determined from the best fit to the measured signals. The residual error was reduced by a factor of 2 by introducing helical filaments instead of toroidal filaments. Using this method, m/n=2/1 and 3/2 modes were identified in Mega-Ampere Spherical Tokamak discharges, and the time evolution of the tearing modes was derived.

17.
Rev Sci Instrum ; 79(10): 10F507, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044652

RESUMO

Parametric decay instability (PDI) is often observed in the TST-2 spherical tokamak during high harmonic fast wave heating by rf pickup probes. The frequency spectrum exhibits lower and upper sideband peaks in addition to the pump wave at f(0)=21 MHz. Two types of PDI are observed. One is the well-known decay into the ion-cyclotron quasimode (nf(ci)) and the ion Bernstein wave (f(0)-nf(ci)). The other is a newly found decay with the sideband frequency between f(0) and f(0)-f(ci). The frequency difference between this sideband and the pump increases in proportion to B(t). Moreover, high-speed visible light measuring systems with photomultiplier tubes or hybrid photodetectors viewing the plasma core detected oscillation of light emission at around f(0).

18.
Rev Sci Instrum ; 78(8): 083502, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764321

RESUMO

An O-mode reflectometer at a frequency of 25.85 GHz was applied to plasmas heated by the high harmonic fast wave (21 MHz) in the TST-2 spherical tokamak. An oscillation in the phase of the reflected microwave in the rf range was observed directly for the first time. In TST-2, the rf (250 kW) induced density oscillation depends mainly on the poloidal rf electric field, which is estimated to be about 0.2 kV/m rms by the reflectometer measurement. Sideband peaks separated in frequency by ion cyclotron harmonics from 21 MHz, and peaks at ion cyclotron harmonics which are suggested to be quasimodes generated by parametric decay, were detected.


Assuntos
Elétrons , Gases/química , Gases/efeitos da radiação , Oscilometria/instrumentação , Ondas de Rádio , Radiometria/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Oscilometria/métodos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Phys Rev Lett ; 95(9): 095002, 2005 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-16197220

RESUMO

Two types of electrostatic modes with small-poloidal wave numbers (approximately 1 and 10-15 kHz) are observed in the edge region of Ohmically heated plasmas in the JFT-2M tokamak. The envelope of the higher frequency coherent mode is modulated at the frequency of the lower frequency mode. A bispectral analysis revealed that a significant nonlinear coupling among the two types of fluctuations and the broadband background turbulent potential fluctuations occurs inside the last closed magnetic flux surface, suggesting that a nonlinear process such as the parametric-modulational instability is involved.

20.
J Clin Ultrasound ; 29(1): 1-6, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11180178

RESUMO

PURPOSE: A B-flow sonographic technique was recently developed to provide direct visualization of blood flow with gray-scale sonography. Compared with color Doppler sonography, B-flow imaging has wideband resolution and a high frame rate. The purpose of this study was to evaluate the usefulness of B-flow sonography for visualizing blood flow in hepatic vessels and tumor vascularity in patients with liver cirrhosis or hepatocellular carcinoma (HCC). METHODS: Twenty-five patients with liver cirrhosis, including 15 with HCC, were studied by B-flow and color Doppler sonography. Blood-flow detection rates in portal veins and hepatic arteries and tumor vascularity in HCC were analyzed, and the 2 methods were compared. RESULTS: Using B-flow, blood flow was visualized in the portal vein in 23 (92%) of 25 patients and was visualized in the hepatic artery separately from the portal vein in 9 (36%) of 25 patients. The blood-flow signals were visualized only within vessels, never "bleeding" outside the vessel's lumen. Blood flow in the portal vein was observed with color Doppler sonography in all 25 patients, but the hepatic artery was never clearly separated from the portal vein. Vascularity within the HCC tumor was detected in 9 (60%) of 15 nodules with B-flow imaging, and fine arteries flowing into the tumor were observed in 6 nodules. Color Doppler sonography detected blood flow in 13 (87%) of the 15 HCC nodules. CONCLUSIONS: Blood flow in hepatic vessels and tumor vessels of HCC were visualized with B-flow sonography. B-flow sonography is a potentially useful technique for the evaluation of liver vascularity and intratumoral vessels.


Assuntos
Carcinoma Hepatocelular/irrigação sanguínea , Processamento de Imagem Assistida por Computador , Cirrose Hepática/patologia , Neoplasias Hepáticas/irrigação sanguínea , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Artéria Hepática/diagnóstico por imagem , Humanos , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...