Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 31(8): 861-874, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26653251

RESUMO

Understanding the fundamental mechanisms involved in the induction of biological damage by ionizing radiation remains a major challenge of today's radiobiology research. The Monte Carlo simulation of physical, physicochemical and chemical processes involved may provide a powerful tool for the simulation of early damage induction. The Geant4-DNA extension of the general purpose Monte Carlo Geant4 simulation toolkit aims to provide the scientific community with an open source access platform for the mechanistic simulation of such early damage. This paper presents the most recent review of the Geant4-DNA extension, as available to Geant4 users since June 2015 (release 10.2 Beta). In particular, the review includes the description of new physical models for the description of electron elastic and inelastic interactions in liquid water, as well as new examples dedicated to the simulation of physicochemical and chemical stages of water radiolysis. Several implementations of geometrical models of biological targets are presented as well, and the list of Geant4-DNA examples is described.


Assuntos
DNA/química , Modelos Moleculares , Método de Monte Carlo , Água/química , Fenômenos Químicos , Humanos
2.
Phys Med Biol ; 59(24): 7573-85, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25415206

RESUMO

It is well-known that in pinhole SPECT (single-photon-emission computed tomography), iterative reconstruction methods including accurate estimations of the system response matrix can lead to submillimeter spatial resolution. There are two different methods for obtaining the system response matrix: those that model the system analytically using an approach including an experimental characterization of the detector response, and those that make use of Monte Carlo simulations. Methods based on analytical approaches are faster and handle the statistical noise better than those based on Monte Carlo simulations, but they require tedious experimental measurements of the detector response. One suggested approach for avoiding an experimental characterization, circumventing the problem of statistical noise introduced by Monte Carlo simulations, is to perform an analytical computation of the system response matrix combined with a Monte Carlo characterization of the detector response. Our findings showed that this approach can achieve high spatial resolution similar to that obtained when the system response matrix computation includes an experimental characterization. Furthermore, we have shown that using simulated detector responses has the advantage of yielding a precise estimate of the shift between the point of entry of the photon beam into the detector and the point of interaction inside the detector. Considering this, it was possible to slightly improve the spatial resolution in the edge of the field of view.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Humanos , Compostos de Organotecnécio/metabolismo , Fótons , Reprodutibilidade dos Testes
3.
Phys Med Biol ; 59(24): 7691-702, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25415376

RESUMO

In this study, fragmentation yields of carbon therapy beams are estimated using the Geant4 simulation toolkit version 9.5. Simulations are carried out in a step-by-step mode using the Geant4-DNA processes for each of the major contributing fragments. The energy of the initial beam is taken 400 MeV amu(-1) as this is the highest energy, which is used for medical accelerators and this would show the integral role of secondary contributions in radiotherapy irradiations. The obtained results showed that 64% of the global dose deposition is initiated by carbon ions, while up to 36% is initiated by the produced fragments including all their isotopes. The energy deposition clustering yields of each of the simulated fragments are then estimated using the DBSCAN clustering algorithm and they are compared to the yields of the incident primary beam.


Assuntos
Carbono/uso terapêutico , Radioterapia com Íons Pesados , Nanotecnologia/métodos , Imagens de Fantasmas , Algoritmos , Simulação por Computador , Humanos , Transferência Linear de Energia , Doses de Radiação , Radiometria/métodos , Eficiência Biológica Relativa
4.
Comput Methods Programs Biomed ; 112(3): 673-83, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24070545

RESUMO

GATE/Geant4 Monte Carlo simulations are computationally demanding applications, requiring thousands of processor hours to produce realistic results. The classical strategy of distributing the simulation of individual events does not apply efficiently for Positron Emission Tomography (PET) experiments, because it requires a centralized coincidence processing and large communication overheads. We propose a parallel computational model for GATE that handles event generation and coincidence processing in a simple and efficient way by decentralizing event generation and processing but maintaining a centralized event and time coordinator. The model is implemented with the inclusion of a new set of factory classes that can run the same executable in sequential or parallel mode. A Mann-Whitney test shows that the output produced by this parallel model in terms of number of tallies is equivalent (but not equal) to its sequential counterpart. Computational performance evaluation shows that the software is scalable and well balanced.


Assuntos
Simulação por Computador , Algoritmos , Método de Monte Carlo
5.
Phys Med Biol ; 58(7): 2395-411, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23492938

RESUMO

Clinical single photon emission computed tomography (SPECT) equipped with pinhole collimators have a magnification factor that results in high spatial resolution images for small animal imaging. Using Monte Carlo simulations to model the acquisition process and the propagation of the photons from their point of emission to their detection point then integrating the model into an iterative reconstruction algorithm improves the signal-to-noise ratio, the contrast and the spatial resolution in the reconstructed images. However, pinhole SPECT systems are known to be very sensitive to geometrical misalignments. Geometrical misalignments are defined as the radial or axial shift of the collimator pinhole and/or twist and tilt of the detector heads and are introduced in the system each time the collimation device is changed (pinhole to parallel holes or vice versa). In this work, we present a flexible detector response function table (DRFT) design that takes into account the geometrical misalignments and avoids performing new Monte Carlo simulations for each exam in order to calculate a geometrical study-dependent system matrix. The utilization of the DRFT for the calculation of the system matrix speeds up its computation time by two orders of magnitude making it acceptable for preclinical and clinical applications.


Assuntos
Método de Monte Carlo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Calibragem , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Ratos , Ratos Wistar
6.
Phys Med Biol ; 57(1): 209-24, 2012 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-22156022

RESUMO

This work presents a Monte Carlo study of energy depositions due to protons, alpha particles and carbon ions of the same linear-energy-transfer (LET) in liquid water. The corresponding track structures were generated using the Geant4-DNA toolkit, and the energy deposition spatial distributions were analyzed using an adapted version of the DBSCAN clustering algorithm. Combining the Geant4 simulations and the clustering algorithm it was possible to compare the quality of the different radiation types. The ratios of clustered and single energy depositions are shown versus particle LET and frequency-mean lineal energies. The estimated effect of these types of radiation on biological tissues is then discussed by comparing the results obtained for different particles with the same LET.


Assuntos
Transferência Linear de Energia , Método de Monte Carlo , Água/química , Algoritmos , Partículas alfa , Carbono , Prótons
7.
Phys Med Biol ; 56(5): 1471-85, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21321386

RESUMO

Some current investigations based on small animal models are dedicated to functional cerebral imaging. They represent a fundamental tool to understand the mechanisms involved in neurodegenerative diseases. In the radiopharmaceutical development approach, the main challenge is to measure the radioactivity distribution in the brain of a subject with good temporal and spatial resolutions. Classical SPECT systems mainly use parallel hole or pinhole collimators. In this paper we investigate the use of a rotating slat collimator system for small animal brain imaging. The proposed prototype consists of a 64-channel multi-anode photomultiplier tube (H8804, Hamamatsu Corp.) coupled to a YAP:Ce crystal highly segmented into 32 strips of 0.575 × 18.4 × 10 mm(3). The parameters of the rotating slat collimator are optimized using GATE Monte Carlo simulations. The performance of the proposed prototype in terms of spatial resolution, detection efficiency and signal-to-noise ratio is compared to that obtained with a gamma camera equipped with a parallel hole collimator. Preliminary experimental results demonstrate that a spatial resolution of 1.54 mm can be achieved with a detection efficiency of 0.012% for a source located at 20 mm, corresponding to the position of the brain in the prototype field of view.


Assuntos
Imagem Molecular/instrumentação , Rotação , Animais , Encéfalo/diagnóstico por imagem , Camundongos , Método de Monte Carlo , Distribuição Normal , Imagens de Fantasmas , Microtomografia por Raio-X
8.
Phys Med Biol ; 50(16): 3739-54, 2005 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16077224

RESUMO

In single photon emission computed tomography (SPECT) with parallel hole collimation, image reconstruction is usually performed as a set of bidimensional (2D) analytical or iterative reconstructions. This approach ignores the tridimensional (3D) nature of scatter and detector response function that affects the detected signal. To deal with the 3D nature of the image formation process, iterative reconstruction can be used by considering a 3D projector modelling the 3D spread of photons. In this paper, we investigate the value of using accurate Monte Carlo simulations to determine the 3D projector used in a fully 3D Monte Carlo (F3DMC) reconstruction approach. Given the 3D projector modelling all physical effects affecting the imaging process, the reconstruction problem is solved using the maximum likelihood expectation maximization (MLEM) algorithm. To validate the concept, three data sets were simulated and F3DMC was compared with two other 3D reconstruction strategies using analytical corrections for attenuation, scatter and camera point spread function. Results suggest that F3DMC improves spatial resolution, relative and absolute quantitation and signal-to-noise ratio. The practical feasibility of the approach on real data sets is discussed.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/métodos , Algoritmos , Simulação por Computador , Estudos de Viabilidade , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Funções Verossimilhança , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Reprodutibilidade dos Testes , Espalhamento de Radiação , Estatística como Assunto , Tomografia Computadorizada de Emissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...