Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BJUI Compass ; 4(2): 135-155, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36816151

RESUMO

Introduction: Radical cystectomy (RC) is historically considered the gold standard treatment for muscle invasive and high-risk non-muscle invasive bladder cancer. However, this technique leaves the majority of patients of both sexes with poor sexual and urinary function. Organ-sparing cystectomy (OSC) techniques are emerging as an alternative to the standard procedure to preserve these functions, without compromising the oncological outcomes. We present a systematic review and meta-analysis of the published literature. Methods: MEDLINE, Embase and Web of Science were systematically searched for eligible studies on 6 April 2021. Primary outcomes studied were both oncological outcomes, specifically overall recurrence, and functional outcomes, specifically sexual function, and daytime and nighttime continence. Odds ratios (OR) with 95% confidence intervals (95% CI) were calculated. The PROSPERO registration reference number was CRD42018118897. Results: From 13 894 identified abstracts, 19 studies (1886 male and 305 female patients) were eligible for inclusion in this review. These studies included patients who underwent either whole prostate, prostate capsule, seminal vesicle, nerve, uterus, ovary, vagina and fallopian tube sparing techniques. Four studies included only female patients.Thirteen studies reported oncological outcomes, and overall recurrence rate was similar between the two groups (five studies; OR 0.73; 95% CI 0.38-1.40, p = 0.34). Thirteen studies reported on male sexual function. In men, OSC had significantly greater odds of retaining potency (five studies; OR 9.05; 95% CI 5.07-16.16, p < 0.00001). Fourteen studies (13 on males and 1 female) reported urinary outcomes. In men, OSC demonstrated greater odds of daytime (seven studies; OR 2.61; 95% CI 1.74 to 3.92, p < 0.00001) and nighttime continence (seven studies; OR 2.62; 95% CI 1.76 to 3.89, p < 0.00001). Conclusion: In carefully selected patients, OSC allows the potential to provide better sexual and urinary function without compromising oncological outcomes. There remains, however, a paucity of OSC studies in females. Further studies are required to make recommendations based on robust clinical evidence.

3.
Urology ; 164: 197-203, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35192862

RESUMO

OBJECTIVE: To assess outcomes following Holmium Laser Enucleation of Prostate (HoLEP) in men with prostate volumes ≥150cc and compare this to men with prostate volumes ≤150 cc. PATIENTS & METHODS: We analyzed our prospective database of consecutive patients undergoing HoLEP in a single tertiary public hospital between October 2016 and January 2019. We excluded patients with clinically significant prostate cancer or neurogenic bladders. Preoperative prostate volume was measured on MRI or ultrasonography. Perioperative variables and functional outcomes were recorded. RESULTS: Of 304 HoLEPs performed, we included 97 patients with prostate volume of ≥150 cc and 186 patients with prostate volume <150 cc. Comparing both cohorts (≥150 cc vs <150 cc): mean age was 71.5 vs 68.3 years, prostate volume 195 cc vs 93 cc, preoperative Qmax 9.6mL/s vs 10mL/s, American Urology Association Symptom Score (IPSS) 21 points vs 20.5 points; mean PSA 13.2µg/L vs 8.8µg/L; laser duration 86 vs 59 minutes; morcellation duration 29 vs 14 minutes; enucleated weight was 124 g vs 60 g. One patient (1%) from the ≥150 cc cohort required a surgical procedure for stress urinary incontinence, and none from the <150 cc cohort, but this did not achieve statistical significance (P = .12). There were no statistically significant differences in postoperative Qmax (32.3 vs 26.4 mL/s; P = .12), IPSS (5.9 points vs 7.3points; P = .23), mean PSA (3.9 µg/L vs 2.2 µg/L; P = .60), stricture incidence (1% vs 2.7%; P = .63), or significant stress urinary incontinence (4.1% vs 0.5%; P = .08). CONCLUSION: Our large series demonstrates that HoLEP is safe and effective in patients with massive prostates (≥150 cc), with similar outcomes compared to patients with prostates <150 cc.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Incontinência Urinária por Estresse , Idoso , Hólmio , Humanos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Masculino , Próstata/diagnóstico por imagem , Próstata/cirurgia , Antígeno Prostático Específico , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/métodos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia
4.
BJUI Compass ; 2(2): 97-104, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33821256

RESUMO

OBJECTIVES: To determine the safety of urological admissions and procedures during the height of the COVID-19 pandemic using "hot" and "cold" sites. The secondary objective is to determine risk factors of contracting COVID-19 within our cohort. PATIENTS AND METHODS: A retrospective cohort study of all consecutive patients admitted from March 1 to May 31, 2020 at a high-volume tertiary urology department in London, United Kingdom. Elective surgery was carried out at a "cold" site requiring a negative COVID-19 swab 72-hours prior to admission and patients were required to self-isolate for 14-days preoperatively, while all acute admissions were admitted to the "hot" site.Complications related to COVID-19 were presented as percentages. Risk factors for developing COVID-19 infection were determined using multivariate logistic regression analysis. RESULTS: A total of 611 patients, 451 (73.8%) male and 160 (26.2%) female, with a median age of 57 (interquartile range 44-70) were admitted under the urology team; 101 (16.5%) on the "cold" site and 510 (83.5%) on the "hot" site. Procedures were performed in 495 patients of which eight (1.6%) contracted COVID-19 postoperatively with one (0.2%) postoperative mortality due to COVID-19. Overall, COVID-19 was detected in 20 (3.3%) patients with two (0.3%) deaths. Length of stay was associated with contracting COVID-19 in our cohort (OR 1.25, 95% CI 1.13-1.39). CONCLUSIONS: Continuation of urological procedures using "hot" and "cold" sites throughout the COVID-19 pandemic was safe practice, although the risk of COVID-19 remained and is underlined by a postoperative mortality.

5.
Surg Endosc ; 32(11): 4590-4596, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29777349

RESUMO

BACKGROUND: Ureteropelvic junction obstruction (UPJO) is characterised by an obstruction compromising the passage of urine from the renal pelvis into the ureter, and can be corrected by Robot-Assisted Laparoscopic Pyeloplasty (RALP). We aimed to evaluate the surgical outcomes of RALP, and examine the rates of true pain resolution following the procedure. METHODS: We retrospectively explored the records of all patients who underwent RALP between April 2005 and January 2017. Measures of success were defined as the prevention of deterioration in split renal function and resolution of obstruction, and the resolution or improvement in subjective pain levels. RESULTS: 83 patients were included in this series. Mean patient age was 40.8 years. 38 patients had a left sided RALP, whilst 45 underwent RALP on the right. Crossing vessels were identified in 53.0% of patients. Mean operative time was 148.0 min. 68 patients had pain as their presenting feature. Following RALP, the pain resolved in 69.2% (n = 47), improved in 26.5% (n = 18), and remained the same in 4.4% (n = 3). 11.8% (n = 8) of patients required referral to other specialities for pain management. Success from a radiological perspective of cleared obstruction and arrest of deteriorating renal function was 97.6%. CONCLUSIONS: Our individual outcomes demonstrate a high success rate regarding resolution of obstruction and preventing deterioration in renal function. We also report that a number of patients, who despite meeting the radiological criteria to undergo RALP, had alternate underlying causes for their pain symptoms. For this reason, we propose that the primary measure of success for RALP should be based on renal function and radiological outcomes, rather than the outcomes relating to pain. Both surgeons and patients should be aware that whilst RALP is a highly successful procedure, persistence of pain may be due to overlapping clinical conditions which can be managed by a multidisciplinary approach.


Assuntos
Laparoscopia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos , Obstrução Ureteral/cirurgia , Procedimentos Cirúrgicos Urológicos , Adulto , Feminino , Humanos , Testes de Função Renal/métodos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Radiografia/métodos , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Obstrução Ureteral/diagnóstico , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Procedimentos Cirúrgicos Urológicos/métodos
6.
J Surg Educ ; 70(1): 161-3, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23337687

RESUMO

AIM: Access to facilities that allow trainees to develop their laparoscopic skills is very limited in the hospital environment and courses can be very expensive. We set out to build an inexpensive yet effective trainer to allow laparoscopic skill acquisition in the home or classroom environment based on using a tablet as a replacement for the laparoscopic stack and camera. METHODS: The cavity in which to train was made from a cardboard box; we left the sides and back open to allow for natural light to fill the cavity. An iPad 2 (Apple Inc.) was placed over the box to act as our camera and monitor. We provided 10 experienced laparoscopic surgeons with the task of passing a suture needle through 3 hoops; then they filled in a questionnaire to assess Face (training capacity) and Content (performance) validity. RESULTS: On a 5-point Likert scale, the tablet-based laparoscopic trainer scored a mean 4.2 for training capacity (hand eye coordination, development, and maintenance of lap skills) and for performance (graphics, video, and lighting quality) it scored a mean 4.1. CONCLUSIONS: The iPad 2-based laparoscopic trainer was successfully validated for training. It allows students and trainees to practice at their own pace and for inexpensive training on the go. Future "app-"based skills are planned.


Assuntos
Competência Clínica , Simulação por Computador , Computadores de Mão , Laparoscopia/educação , Técnicas de Sutura , Humanos , Inquéritos e Questionários , Análise e Desempenho de Tarefas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...