Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 5(5): 281-90, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23297247

RESUMO

The continuous appearance of novel psychoactive substances (NPS) in legal high products presents a challenge for the routine analytical laboratory. A rapid screening method for NPS analysis using fast gas chromatography mass spectrometry (fast GC-MS) is presented. Twenty-three analytes, including 5-iodo-2-aminoindane (5-IAI), 1-(thiophen-2-yl)-2-methylaminopropane (MPA), 1-benzylpiperazine (BZP), 4-methylmethcathinone (mephedrone), 5,6-methylenedioxy-2-aminoindane (MDAI) and methoxetamine (MXE) were separated within 4 min. The method was used to analyze 35 Internet and head shop purchased 'legal high' products with the successful identification of their active ingredients. As previously observed, legal high products do not always contain their stated ingredients. Of the group of products purchased as 5-IAI not one contained 5-IAI with several containing mixtures of substances either already controlled in the UK or under consideration by the Advisory Council on Misuse of Drugs (ACMD). The low bleed and high inertness of the chromatography column used ensured clean high quality mass spectrometry data which when combined with the short run time resulted in an efficient tool for NPS screening, even when standards were unavailable. Electron impact and chemical ionization mass spectra used in combination for the identification of unknown NPS are presented.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Drogas Ilícitas/análise , Indanos/análise , Psicotrópicos/análise , Detecção do Abuso de Substâncias/métodos , Cromatografia Gasosa-Espectrometria de Massas/economia , Detecção do Abuso de Substâncias/economia , Fatores de Tempo
2.
Drug Test Anal ; 5(7): 573-80, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22639448

RESUMO

A comparison between microcrystalline tests performed on microscope slides and flat capillary tubes with inner diameters ranging from 0.1 to 0.7 mm was carried out to explore the appropriateness of tubes for rapid testing of suspected drugs of abuse in the laboratory as well as in the field. Tests for mephedrone, cocaine, and phencyclidine were chosen as examples to investigate the handling of the capillary tubes, the influence on crystal habit, size, and the effects on the limit of detection. Image stacking software was used to increase the depth of field of micrographs taken from developed microcrystals greatly enhancing the interpretability even months after carrying out the microcrystalline test. Additionally, the potential of seeding capillary tubes with a reagent was studied. Pre-treatment of tubes would allow microcrystalline tests to be carried out quicker and anywhere without the necessity of taking along expensive and hazardous reagents. The sealing of capillary tubes containing developed microcrystalline tests in order to preserve results for a long period of time was successfully done by applying paraffin wax to the open ends. Finally, it was concluded that capillary tubes are suitable vessels for performing microcrystalline tests. The increased portability of the improved set-up allows tests to be safely executed outside laboratories without impairing the quality of the result. Findings were applied to six legal high samples purchased online between May and August 2011. The active ingredients like MDAI as well as cutting agents like caffeine were successfully identified using the microcrystalline test technique in capillary tubes.


Assuntos
Tubo Capilar/normas , Detecção do Abuso de Substâncias/instrumentação , Detecção do Abuso de Substâncias/normas , Cristalização , Detecção do Abuso de Substâncias/métodos
3.
Forensic Sci Int ; 207(1-3): e55-8, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21288671

RESUMO

A combined analysis of microcrystalline tests followed by LC-MS or GC-MS analysis is described. Microcrystalline tests are shown to be non-destructive as addition products formed were easily dissociated after the application of an appropriate solvent. Subsequent analysis of the sample was done to quantify the recovery of the drug. Examples were performed using the date rape drug γ-hydroxybutyrate (GHB) and the synthetic opioid methadone.

4.
J Forensic Sci ; 53(1): 147-50, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18279251

RESUMO

An enhancement of the microcrystalline test for the detection of gamma-hydroxybutyrate (GHB) is described. The original test used a silver/copper reagent which consisted of 0.1 g of silver nitrate and 0.1 g of copper nitrate in 10 mL water. The enhanced test utilizes lanthanum nitrate in place of copper nitrate. A detection limit of 0.5 mg/mL was achieved and the visual discrimination was improved because of larger sized crystals. Transient crystals were observed between 0.1 and 0.4 mg/mL. Silver nitrate alone appeared to be suitable for GHB detection but was not specific as other hydroxyl acids, such as glycolic acid, produced a similar crystal pattern. Tests conducted on chemical precursors of GHB and substances with similar biological activity highlight the specificity of the enhanced test. The reagent is therefore selective and sensitive for GHB in aqueous solutions. However, in beverage testing, crystal formation appeared to be inhibited for some drinks. Citric acid was identified as a possible interference depending on its concentration relative to GHB.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...