Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(25): 253002, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38181339

RESUMO

We present the measurements of individual bound electron g factors of ^{20}Ne^{9+} and ^{22}Ne^{9+} on the relative level of 0.1 parts per billion. The comparison with theory represents the most stringent test of bound-state QED in strong electric fields. A dedicated mass measurement results in m(^{20}Ne)=19.992 440 168 77(9) u, which improves the current literature value by a factor of 18, disagrees by 4 standard deviations, and represents the most precisely measured mass value in atomic mass units. Together, these measurements yield an electron mass on the relative level of 0.1 ppb with m_{e}=5.485 799 090 99(59)×10^{-4} u as well as a factor of seven improved m(^{22}Ne)=21.991 385 098 2(26) u.

2.
Nanotechnology ; 33(1)2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34592729

RESUMO

The most significant goal of nanophotonics is the development of high-speed quantum emitting devices operating at ambient temperature. In this regard, plasmonic nanoparticles-on-mirror are potential candidates for designing high-speed photon sources. We introduce a novel hybrid nanoantenna (HNA) with CdSe/CdS colloidal quantum dots (QDs) based on a silver nanocube in a metal cup that presents a nanoparticle-in-cavity coupled with an emitters system. We use focused ion beam nanolithography to fabricate an ordered array of cups, which were then filled with colloidal nanoparticles using the most simple drop-casting and spin coating methods. The spectral and time-resolved studies of the samples with one or more nanocubes in the cup reveal a significant change in the radiation characteristics of QDs inside the nanoantenna. The Purcell effect causes an increase in the fluorescence decay rate (≥30) and an increase in the fluorescence intensity (≥3) of emitters in the HNA. Using the finite element method simulations, we have discovered that the proximity of the cups wall affects the oscillation modes of the gap plasmon, which, in turn, leads to changes in the electric field enhancement inside the nanoantenna gap. Additionally, substantial variations in the behavior of the gap plasmons at different polarizations of the exciting radiation have been revealed. The proposed nanoantenna can be useful in the development of plasmonic sensors, display pixels, and single-photon sources.

3.
Phys Rev Lett ; 127(7): 072502, 2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34459634

RESUMO

The cyclotron frequency ratio of ^{187}Os^{29+} to ^{187}Re^{29+} ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of R=1.000 000 013 882(5) is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multiconfiguration methods, yielding the value of ΔE=53.5(10) eV. Finally, using the achieved results, the mass difference between neutral ^{187}Re and ^{187}Os, i.e., the Q value of the ß^{-} decay of ^{187}Re, is determined to be 2470.9(13) eV.

4.
Nanotechnology ; 31(50): 505206, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33021216

RESUMO

Recent advances in nanotechnology and optics have paved the way for new plasmonic devices. One of them are nanopatch antennas that are simple and, at the same time, effective devices for localizing the electromagnetic field on a scale of less than 10 nm and can be used in photonic integrated circuits as effective sources of photons, including single-photon sources. In the present study, we investigate the radiative characteristics of a submonolayer of colloidal CdSe/CdS quantum dots that form island structures in a resonator: a cubic silver nanoparticle on an aluminum mirror. For detecting plasmonic nanoparticles on glass or metal surfaces, we propose a new technique involving a tunable laser and a confocal microscope. We provide a comparative study of the luminescence enhancement factors for QDs in the NPAs upon off-resonance excitation and at a wavelength close to the resonance; a significant difference in the luminescence enhancement factors (by order of magnitude) is demonstrated. A 60-fold reduction in the spontaneous emission time, as well as an increase in the radiation intensity by a factor of 330, has been obtained in the experiments. The increase in the spontaneous emission rate demonstrated for the quantum dots is explained by the Purcell effect. Full-wave simulations of electromagnetic fields were carried out for the model of the developed nanopatch antenna; luminescence enhancement factors and radiative efficiencies were calculated as well.

5.
Nature ; 581(7806): 42-46, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32376960

RESUMO

State-of-the-art optical clocks1 achieve precisions of 10-18 or better using ensembles of atoms in optical lattices2,3 or individual ions in radio-frequency traps4,5. Promising candidates for use in atomic clocks are highly charged ions6 (HCIs) and nuclear transitions7, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range8 that are accessible to frequency combs9. However, insufficiently accurate atomic structure calculations hinder the identification of suitable transitions in HCIs. Here we report the observation of a long-lived metastable electronic state in an HCI by measuring the mass difference between the ground and excited states in rhenium, providing a non-destructive, direct determination of an electronic excitation energy. The result is in agreement with advanced calculations. We use the high-precision Penning trap mass spectrometer PENTATRAP to measure the cyclotron frequency ratio of the ground state to the metastable state of the ion with a precision of 10-11-an improvement by a factor of ten compared with previous measurements10,11. With a lifetime of about 130 days, the potential soft-X-ray frequency reference at 4.96 × 1016 hertz (corresponding to a transition energy of 202 electronvolts) has a linewidth of only 5 × 10-8 hertz and one of the highest electronic quality factors (1024) measured experimentally so far. The low uncertainty of our method will enable searches for further soft-X-ray clock transitions8,12 in HCIs, which are required for precision studies of fundamental physics6.

6.
Phys Rev Lett ; 124(11): 113001, 2020 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-32242713

RESUMO

First ever measurements of the ratios of free cyclotron frequencies of heavy, highly charged ions with Z>50 with relative uncertainties close to 10^{-11} are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from ^{126}Xe to ^{134}Xe, have been determined. Moreover, the first direct measurement of an electron binding energy in a heavy highly charged ion, namely of the 37th atomic electron in xenon, with an uncertainty of a few eV is demonstrated. The obtained value agrees with the calculated one using two independent, different implementations of the multiconfiguration Dirac-Hartree-Fock method. PENTATRAP opens the door to future measurements of electron binding energies in highly charged heavy ions for more stringent tests of bound-state quantum electrodynamics in strong electromagnetic fields and for an investigation of the manifestation of light dark matter in isotopic chains of certain chemical elements.

7.
Phys Rev Lett ; 124(9): 092502, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32202869

RESUMO

We probe the N=82 nuclear shell closure by mass measurements of neutron-rich cadmium isotopes with the ISOLTRAP spectrometer at ISOLDE-CERN. The new mass of ^{132}Cd offers the first value of the N=82, two-neutron shell gap below Z=50 and confirms the phenomenon of mutually enhanced magicity at ^{132}Sn. Using the recently implemented phase-imaging ion-cyclotron-resonance method, the ordering of the low-lying isomers in ^{129}Cd and their energies are determined. The new experimental findings are used to test large-scale shell-model, mean-field, and beyond-mean-field calculations, as well as the ab initio valence-space in-medium similarity renormalization group.

8.
J Opt Soc Am A Opt Image Sci Vis ; 36(9): 1505-1511, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31503844

RESUMO

Periodical spatial modulation of the excitonic resonance in a quantum well could lead to the formation of a new highly directional and resonant coherent optical response-resonant diffraction. Such excitonic diffraction gratings were demonstrated in epitaxially grown quantum wells patterned by low-dose ion beam irradiation before or after the growth. In this paper we present a theoretical model of the resonant diffraction formation based on the step-by-step approximation of the Maxwell equation solution. The resulting theory allows us to reliably describe experimental data as well as to predict a way to increase the diffraction efficiency.

9.
Phys Rev Lett ; 122(14): 147401, 2019 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-31050466

RESUMO

We report on the experimental evidence for a nanosecond timescale spin memory based on nonradiative excitons with large in-plane wave vector. The effect manifests itself in magnetic-field-induced oscillations of the energy of the optically active (radiative) excitons. The oscillations detected by a spectrally resolved pump-probe technique applied to a GaAs/AlGaAs quantum well structure in a transverse magnetic field persist over a timescale, which is orders of magnitude longer than the characteristic decoherence time in the system. The effect is attributed to the spin-dependent electron-electron exchange interaction of the optically active and inactive excitons. The spin relaxation time of the electrons belonging to nonradiative excitons appears to be much longer than the hole spin relaxation time.

10.
Rev Sci Instrum ; 90(12): 123201, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893798

RESUMO

This paper reports on the development and testing of a novel, highly efficient technique for the injection of very rare species into electron beam ion traps (EBITs) for the production of highly charged ions (HCI). It relies on in-trap laser-induced desorption of atoms from a sample brought very close to the electron beam resulting in a very high capture efficiency in the EBIT. We have demonstrated a steady production of HCI of the stable isotope 165Ho from samples of only 1012 atoms (∼300 pg) in charge states up to 45+. HCI of these species can be subsequently extracted for use in other experiments or stored in the trapping volume of the EBIT for spectroscopic measurements. The high efficiency of this technique extends the range of rare isotope HCIs available for high-precision atomic mass and spectroscopic measurements. A first application of this technique is the production of HCI of the synthetic radioisotope 163Ho for a high-precision measurement of the QEC-value of the electron capture in 163Ho within the "Electron Capture in Holmium" experiment [L. Gastaldo et al., J. Low Temp. Phys. 176, 876-884 (2014); L. Gastaldo et al., Eur. Phys. J.: Spec. Top. 226, 1623-1694 (2017)] (ECHo collaboration) ultimately leading to a measurement of the electron neutrino mass with an uncertainty on the sub electronvolt level.

11.
Opt Lett ; 41(1): 104-6, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26696169

RESUMO

We propose a method of spatial modulation of inhomogeneous broadening of a quantum-well excitonic resonance based on local generation of defects produced by a focused ion beam. The method is applied to fabrication of excitonic diffraction grating in a single quantum-well InGaAs/GaAs structure by irradiating the sample with a beam of 35-keV He+ ions of exposure doses <1012 cm-2. The spectrum of resonant diffraction on such a structure is narrower than that of reflectivity and decreases much faster with increasing temperature. A proposed model of formation of the diffractive response based on the single scattering approximation well describes the results of the spectral and temperature measurements.

12.
Phys Rev Lett ; 115(6): 062501, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26296112

RESUMO

The atomic mass difference of (163)Ho and (163)Dy has been directly measured with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. Our measurement has solved the long-standing problem of large discrepancies in the Q value of the electron capture in (163)Ho determined by different techniques. Our measured mass difference shifts the current Q value of 2555(16) eV evaluated in the Atomic Mass Evaluation 2012 [G. Audi et al., Chin. Phys. C 36, 1157 (2012)] by more than 7σ to 2833(30(stat))(15(sys)) eV/c(2). With the new mass difference it will be possible, e.g., to reach in the first phase of the ECHo experiment a statistical sensitivity to the neutrino mass below 10 eV, which will reduce its present upper limit by more than an order of magnitude.

13.
Eksp Klin Gastroenterol ; (7): 85-96, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26817127

RESUMO

According to the World Health Organization, it is recorded steady growth of the number of chronic liver diseases, including nonalcoholic fatty liver disease (NAFLD), in recent years. As an independent nosological entity, NAFLD is one of the risk factors for cardiovascular diseases, associated with abdominal-visceral obesity, peripheral insulin resistance (IR), and is regarded as the hepatic component of Metabolic syndrome (MS). Nowadays there are no generally accepted national standards for diagnosis and treatment of NAFLD for physicians, gen- eral practitioners, gastroenterologists in Russia. This was the essential reason in their development. The main reason of The guidelines development is the absence of generally accepted national standards for diagnosis and treatment of NAFLD for physicians, general practitioners, gastroenterologists in Russia. These guidelines are based on the global and local data of treatment experience of NAFLD, recently published in reviews, analytical studies in the literature. Guidelines are intended for physicians, general practitioners, gastroenterologists and contain the description of the preferred approaches to the provision of diagnostic, curative and preventive care of patients NAFLD. The quality of recommendations was grading according to the GRADE approach.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/patologia , Hepatopatia Gordurosa não Alcoólica/terapia , Humanos , Guias de Prática Clínica como Assunto
14.
Phys Rev Lett ; 110(8): 082501, 2013 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-23473137

RESUMO

A novel approach based on the projection of the Penning-trap ion motion onto a position-sensitive detector opens the door to very accurate mass measurements on the ppb level even for short-lived nuclides with half-lives well below a second. In addition to the accuracy boost, the new method provides a superior resolving power by which low-lying isomeric states with excitation energy on the 10-keV level can be easily separated from the ground state. A measurement of the mass difference of ^{130}Xe and ^{129}Xe has demonstrated the great potential of the new approach.

15.
Science ; 337(6099): 1207-10, 2012 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-22878498

RESUMO

Quantum-mechanical shell effects are expected to strongly enhance nuclear binding on an "island of stability" of superheavy elements. The predicted center at proton number Z = 114, 120, or 126 and neutron number N = 184 has been substantiated by the recent synthesis of new elements up to Z = 118. However, the location of the center and the extension of the island of stability remain vague. High-precision mass spectrometry allows the direct measurement of nuclear binding energies and thus the determination of the strength of shell effects. Here, we present such measurements for nobelium and lawrencium isotopes, which also pin down the deformed shell gap at N = 152.

16.
Phys Rev Lett ; 107(15): 152501, 2011 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-22107289

RESUMO

The theory of octupolar-excitation ion-cyclotron-resonance mass spectrometry is presented which predicts an increase of up to several orders of magnitude in resolving power under certain conditions. The new method has been applied for a direct Penning-trap mass-ratio determination of the (164)Er-(164)Dy mass doublet. (164)Er is a candidate for the search for neutrinoless double-electron capture. However, the measured Q(ϵϵ) value of 25.07(12) keV results in a half-life of 10(30) years for a 1 eV Majorana-neutrino mass.

17.
Phys Rev Lett ; 106(12): 122501, 2011 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-21517310

RESUMO

The masses of ten proton-rich nuclides, including the N=Z+1 nuclides 85Mo and 87Tc, were measured with the Penning trap mass spectrometer SHIPTRAP. Compared to the Atomic Mass Evaluation 2003 a systematic shift of the mass surface by up to 1.6 MeV is observed causing significant abundance changes of the ashes of astrophysical x-ray bursts. Surprisingly low α separation energies for neutron-deficient Mo and Tc are found, making the formation of a ZrNb cycle in the rp process possible. Such a cycle would impose an upper temperature limit for the synthesis of elements beyond Nb in the rp process.

18.
Phys Rev Lett ; 106(5): 052504, 2011 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-21405389

RESUMO

In the search for the nuclide with the largest probability for neutrinoless double-electron capture, we have determined the Q(ϵϵ) value between the ground states of (152)Gd and (152)Sm by Penning-trap mass-ratio measurements. The new Q(ϵϵ) value of 55.70(18) keV results in a half-life of 10(26) yr for a 1 eV neutrino mass. With this smallest half-life among known 0νϵϵ transitions, (152)Gd is a promising candidate for the search for neutrinoless double-electron capture.

19.
Khirurgiia (Mosk) ; (5): 25-32, 2010.
Artigo em Russo | MEDLINE | ID: mdl-20559207

RESUMO

Data of 14 patients with chronic cystic pancreatitis, complicated by intracystic bleeding, were analyzed. Early diagnosis of a bleeding episode provides an in-time diagnostic and treatment procedures. Angiographic bleeding vessel occlusion is considered to be a method of choice. When the latter is impossible, a method of temporary intraoperative hemostasis is suggested, which decreases blood loss and permits an adequate surgical aid.


Assuntos
Hemostasia Cirúrgica/métodos , Cisto Pancreático/cirurgia , Pancreatite Crônica/cirurgia , Hemorragia Pós-Operatória/prevenção & controle , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cisto Pancreático/etiologia , Pancreatite Crônica/complicações , Hemorragia Pós-Operatória/diagnóstico por imagem , Radiografia , Ultrassonografia
20.
Nature ; 463(7282): 785-8, 2010 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-20148034

RESUMO

The mass of an atom incorporates all its constituents and their interactions. The difference between the mass of an atom and the sum of its building blocks (the binding energy) is a manifestation of Einstein's famous relation E = mc(2). The binding energy determines the energy available for nuclear reactions and decays (and thus the creation of elements by stellar nucleosynthesis), and holds the key to the fundamental question of how heavy the elements can be. Superheavy elements have been observed in challenging production experiments, but our present knowledge of the binding energy of these nuclides is based only on the detection of their decay products. The reconstruction from extended decay chains introduces uncertainties that render the interpretation difficult. Here we report direct mass measurements of trans-uranium nuclides. Located at the farthest tip of the actinide species on the proton number-neutron number diagram, these nuclides represent the gateway to the predicted island of stability. In particular, we have determined the mass values of (252-254)No (atomic number 102) with the Penning trap mass spectrometer SHIPTRAP. The uncertainties are of the order of 10 keV/c(2) (representing a relative precision of 0.05 p.p.m.), despite minute production rates of less than one atom per second. Our experiments advance direct mass measurements by ten atomic numbers with no loss in accuracy, and provide reliable anchor points en route to the island of stability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...