Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 22(1): 216, 2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35300620

RESUMO

BACKGROUND: To evaluate the impact of interval between induction of spinal anesthesia to delivery of the fetus by elective cesarean section on umbilical arterial pH and neonatal outcome. PATIENTS AND METHODS: Two hundred and twenty pregnant women who were planned for elective cesarean section at term under spinal anesthesia were recruited. Minimum systolic, diastolic and mean arterial blood pressures (SBP, DBP, MAP) and largest pressure decrease (SBP, DBP, MPA) were also recorded. Induction of spinal anesthesia to delivery interval was measured. Following delivery, umbilical arterial cord analysis for pH and base deficit were done. Apgar scores at 1 min and at 5 min, neonatal intensive care unit (NICU) admission, need for mechanical ventilation and incidence of hypoxemic-ischemic encephalopathy were recorded. RESULTS: Induction of spinal anesthesia to delivery interval was 25.7 ± 5.6 min. Lowest SBP and MAP reached during cesarean delivery were 88.9 ± 7.3 mmHg and 60.4 ± 5.6 mmHg, respectively. MAP < 65 mmHg was reached in 136 (62%) patients with a decrease of MAP of > 20% in 149 (68%) patients. Duration of the longest hypotension episode was 3.3 ± 2.2 min. All patients required ephedrine administration for hypotensive episodes with an average dosage of 11.4 ± 3.2 mg. Umbilical pH of 7.3 ± 0.1 and base deficit of 8.3 ± 4.4 mmol/l were recorded. Apgar scores at 5 min were 8.5 ± 1.2. Eight (3.6%) neonates were admitted in the NICU. One neonate needed mechanical ventilation. There were no cases of hypoxemic-ischemic encephalopathy. There were inverse correlations between induction of spinal anesthesia to delivery interval, body mass index (BMI) and duration of longest hypotension episode in relation to umbilical pH (r = -0.817, -0.395 and -0.268, respectively). Cut off value for induction of spinal anesthesia to delivery interval greater than 27 min predicted an umbilical pH of < 7.2. Cut off value for the duration of the longest hypotension episode greater than 5 min predicted an umbilical pH of < 7.2. Cut off value for BMI greater than 35 kg/m2 predicted an umbilical pH of < 7.2. CONCLUSION: Prolonged interval between induction of spinal anesthesia to delivery could be associated with neonatal acidosis. This could be aggravated by maternal obesity and prolonged duration of hypotension episodes during cesarean delivery.


Assuntos
Raquianestesia , Cesárea , Sangue Fetal/química , Cordão Umbilical/química , Acidose/epidemiologia , Índice de Apgar , Pressão Sanguínea , Feminino , Humanos , Concentração de Íons de Hidrogênio/efeitos dos fármacos , Recém-Nascido , Doenças do Recém-Nascido/epidemiologia , Gravidez , Fatores de Tempo
2.
J Microsc Ultrastruct ; 9(3): 103-107, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34729349

RESUMO

AIM: The aim was to assess the risk of osteopenia and osteoporosis and to identify possible risk factors affecting bone density (BD) during pregnancy as parity, body mass index (BMI), Vitamin D, and calcium supplementation using quantitative ultrasound (QUS) of the calcaneus among first- and third-trimester pregnant women. METHODS: It is a case-control study conducted at Ain Shams Maternity Hospital, Egypt, from May 7 to December 14, 2015. One hundred and thirty-two women in the third trimester and 33 matched controls in the first trimester were screened for BD at the calcaneus by QUS. Stiffness index (SI), QUS-T, and Z scores were measured. RESULTS: Comparing both the groups regarding QUS-T score, Z score, and SI showed a statistically significant difference between both groups. Third-trimester participants had lower scores (-0.72 ± 1.0, -0.63 ± 0.99, and 88.53 ± 14.81, respectively) compared to their matched controls (1.05 ± 0.89, 1.16 ± 0.91, and 113.79 ± 12.49, respectively). According to QUS-T scores, 82 women (62.1%) in the third-trimester group were assessed as having normal BD, whereas 47 women (35.6%) were at risk of being osteopenic and 3 women (2.3%) were at risk of being osteoporotic. All women of the first trimester were assessed as having normal BD. Logistic regression was performed to identify possible risk factors affecting BD among third-trimester patients. BMI was the only statistically significant predictor for changes in bone health in those women (P = 0.001, odds ratio: 0.857, 95% confidence interval: 0.786-0.936). CONCLUSION: With one-unit rise in BMI, a 14% reduction in risk of decreased bone health is obtained.

3.
Obstet Gynecol Int ; 2016: 3561324, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28003825

RESUMO

The aim is to compare hysteroscopy, two-dimensional transvaginal ultrasound (2D TVUS), and three-dimensional (3D) Virtual Organ Computer-aided AnaLysis™ (VOCAL) to detect endometrial polyps (EPs) in premenopausal women with abnormal uterine bleeding (AUB). This prospective study was done at Ain Shams Maternity Hospital, Egypt, from March 5, 2015, to December 30, 2015, enrolling 118 premenopausal women with AUB. 2D TVUS, 3D VOCAL, and hysteroscopy were done. 109 patients reached final analysis. 36 women (33%) were diagnosed with EP by 2D TVUS. 50 (45.9%) had EP by hysteroscopy. Endometrial thickness was 10.1 mm by 2D TVUS and endometrial volume was 4.92 mL by VOCAL in women with EP by hysteroscopy compared to 9.9 mm and 3.50 mL in women with no EP, respectively (P = 0.223; P = 0.06). 2D TVUS has sensitivity, specificity, and positive and negative predictive values of 54%, 84.7%, 75%, and 68.5%, respectively. Endometrial thickness of >7.5 mm has sensitivity, specificity, positive and negative predictive values, and overall accuracy of 82%, 37.3%, 52.6%, 71%, and 57.8%, respectively. Endometrial volume of >1.2 mL has sensitivity, specificity, positive and negative predictive values, and overall accuracy of 90%, 42.4%, 57%, 83.3%, and 64.2%, respectively. 3D VOCAL may be used as a noninvasive method for the diagnosis of EP in premenopausal women with AUB.

4.
J Matern Fetal Neonatal Med ; 29(5): 850-4, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25758628

RESUMO

OBJECTIVE: To study the efficacy of 100 µg intravenous shot of carbetocin compared to 20 IU oxytocin intravenous infusion to prevent placental retention in second trimester medical termination of pregnancy. METHODS: A double-blinded randomized controlled trial was conducted at Ain Shams University Maternity Hospital from 1 April 2013 to 30 November 2013. A total of 132 women between 14 and 24 weeks gestation indicated for termination were randomized to receive either 20 IU oxytocin infusion (n = 66) or 100 µg carbetocin shot (n = 66) after fetal expulsion. Patients were observed for time elapsed between fetal and placental expulsion, presence of placental retention and blood loss. RESULTS: Third stage was 33.4 ± 20.4 min in oxytocin group & 23.1 ± 16.8 min in carbetocin group (p = 0.002). Eight patients (12.1%) in oxytocin group had complete placental retention versus two patients (3.0%) in carbetocin group (p = 0.05). Eight patients (13.8%) received oxytocin had remnants of placenta compared to four patients (6.2%) received carbetocin (p = 0.04). Sixteen patients (24.2%) received oxytocin and six patients (9%) received carbetocin needed surgical curettage (p = 0.04). Third stage blood loss was 87.2 ± 33.7 ml in carbetocin and 206.9 ± 35.2 ml in oxytocin groups (p = 0.001). CONCLUSION: Carbetocin is superior to oxytocin infusion for management of placental delivery in second trimester abortion.


Assuntos
Aborto Eugênico/métodos , Ocitocina/análogos & derivados , Ocitocina/administração & dosagem , Placenta Retida/prevenção & controle , Segundo Trimestre da Gravidez , Aborto Eugênico/estatística & dados numéricos , Administração Intravenosa , Adulto , Feminino , Humanos , Recém-Nascido , Projetos Piloto , Placenta/efeitos dos fármacos , Placenta Retida/epidemiologia , Hemorragia Pós-Parto/epidemiologia , Hemorragia Pós-Parto/prevenção & controle , Gravidez , Segundo Trimestre da Gravidez/efeitos dos fármacos , Resultado do Tratamento , Adulto Jovem
5.
Artigo em Inglês | MEDLINE | ID: mdl-26664250

RESUMO

OBJECTIVE: The aim of this study was to estimate the accuracy of prenatal assessment of interventricular septum (IVS) thickness, right myocardial wall thickness (RMWT), and left myocardial wall thickness (LMWT) by two-dimensional (2D) ultrasound for the prediction of perinatal mortality and postnatal diagnosis of hypertrophic cardiomyopathy (HCM) among diabetic pregnant women. SUBJECTS AND METHODS: A total of 120 diabetic pregnant women at 35 weeks or more were enrolled in this study from January 1, 2012, to June 30, 2014, at Ain Shams Maternity Hospital, Cairo, Egypt. The 2D ultrasound was done once for all the participants at the time of recruitment; IVS thickness, RMWT, and LMWT were measured. The glycosylated hemoglobin (HbA1c) levels of the participants were recorded. Neonatal assessment including postnatal echocardiography was done after 48 hours. Postnatal results were compared with the prenatal predictive results. RESULTS: Higher thickness values for IVS, RMW, and LMW were obtained in the uncontrolled diabetic cases (HbA1c > 6.5%) than in the controlled diabetic cases (HbA1c < 6.5%; P < 0.01). Of the included 120 neonates, 10 (8.3%) were stillborn, 99 (82.5%) had a five-minute Apgar score ≥7, and 4 (3.3%) had a five-minute Apgar score ≤3. The four neonates with severe neonatal distress died after admission to neonatal intensive care unit within one week after delivery. Out of 110 live-born neonates, 4 (3.6%) neonates had a low ejection fraction (EF) (<50%) due to HCM; of them 2 (1.8%) died within one week after delivery, while 2 (1.8%) survived. Another two (1.8%) neonates died from severe respiratory distress syndrome. A cutoff value of ≥4.5 mm for prenatal IVS thickness was predictive of neonatal distress due to HCM with a sensitivity of 82%, specificity of 68%, and diagnostic accuracy of 72%. A cutoff value of <1.18 for the ratio of IVS thickness to LMWT had a sensitivity of 82%, specificity of 72%, and diagnostic accuracy of 74% for the prediction of neonatal distress due to HCM. In this study, 8 of the 10 fetuses with intrauterine demise and the 2 neonates who died within one week after delivery due to heart failure had a prenatal IVS thickness of ≥4.5 mm, while 7 of the 10 fetuses with intrauterine demise and the 2 neonates who died postnatal from heart failure had a prenatal IVS thickness to LMWT ratio of ≤1.18. CONCLUSION: A prenatal IVS thickness of ≥4.5 mm or an IVS/LMWT ratio of ≤1.18 seems to be predictive of HCM and is associated with almost twofold higher risk of intrauterine fetal death and almost threefold higher risk of possibly relevant perinatal mortality.

6.
Int J Gynaecol Obstet ; 128(3): 246-50, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25468052

RESUMO

OBJECTIVE: To develop reference cutoff values for mean fetal lung volume (FLV) and pulmonary artery resistance index (PA-RI) for prediction of neonatal respiratory distress syndrome (RDS) in low-risk term pregnancies. METHODS: As part of a cross-sectional study, women aged 20-35 years were enrolled and admitted to a tertiary hospital in Cairo, Egypt, for elective repeat cesarean at 37-40 weeks of pregnancy between January 1, 2012, and July 31, 2013. FLV was calculated by virtual organ computer-aided analysis, and PA-RI was measured by Doppler ultrasonography before delivery. RESULTS: A total of 80 women were enrolled. Neonatal RDS developed in 11 (13.8%) of the 80 newborns. Compared with neonates with RDS, healthy neonates had significantly higher FLVs (P<0.001) and lower PA-RIs (P<0.001). Neonatal RDS is less likely with FLV of at least 32 cm(3) or PA-RI less than or equal to 0.74. Combining these two measures improved the accuracy of prediction. CONCLUSION: The use of either FLV or PA-RI predicted neonatal RDS. The predictive value increased when these two measures were combined.


Assuntos
Pulmão/embriologia , Artéria Pulmonar/embriologia , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Adulto , Recesariana , Estudos Transversais , Egito , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Recém-Nascido , Medidas de Volume Pulmonar/métodos , Valor Preditivo dos Testes , Gravidez , Síndrome do Desconforto Respiratório do Recém-Nascido/epidemiologia , Ultrassonografia Doppler/métodos , Resistência Vascular/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...