1.
J Surg Case Rep ; 2021(4): rjab089, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33897996

RESUMO

Post-thyroidectomy bleeding is a fortunately rare but potentially life-threatening complication that may increase postoperative morbidity and hospital stay. In this case series, we demonstrate the relation between the measurement of neck circumference and haemorrhage following thyroid surgery and the value of this measurement in predicting post-thyroidectomy haemorrhage. Currently, there is no simple and reliable method available for the early detection of post-thyroidectomy bleeding. Continuous pressure measurement could be a potential tool for the early detection of haemorrhage but is invasive, and more data are required to recommend threshold values for revision surgery. Early recognition and prompt surgical intervention are key to the management of cervical haematoma. Measurement of the neck circumference is a valuable adjunct tool in the early recognition of post-thyroidectomy bleeding. In this case series, we concluded that a 4-cm increase in neck circumference may trigger the clinical decision for cervical exploration.