1.
Anal Chem ; 92(15): 10597-10605, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32564597

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are emerging as harmful environmental micropollutants. Generally, PFAS species are quantified by mass spectrometry, for which a collected sample is taken to a centralized facility. Robust techniques to quantify PFAS in the field are necessary to diagnose environmental contamination at the earliest onset of pollution. Here, we developed a molecularly imprinted polymer (MIP) electrode for the detection of perfluorooctanesulfonate (PFOS) and explored the MIP surface and the effects of interfering molecules. MIPs were formed by the anodic deposition of o-phenylenediamine (o-PD) in the presence of PFOS template molecules on a glassy carbon macroelectrode. The performance of the resulting MIP electrode was evaluated by the current obtained from the oxidation of ferrocene carboxylic acid as the electrochemical probe. The MIP electrode was able to detect PFOS with a detection limit of 0.05 nM, which is lower than the health advisory limit of 0.14 nM reported by the U.S. EPA. To better understand PFOS association into the MIP, a Langmuir binding model was developed based on the changes in electrochemical responses of the MIP. Fitting the model to the experimental data gave an association constant (KA) of 4.95 × 1012 over a PFOS concentration range of 0 to 0.05 nM. The binding isotherm of other commonly found substances in contaminated water sources such as chloride, humic acid, perfluorooctanoic acid (PFOA), and perfluorobutanesulfonate (PFBS) was also investigated. In the case of chloride and humic acid, the calculated KA values of 9.05 × 107 and 6.01 × 105, respectively, indicate relatively weak adsorption of these species on the MIP. However, PFOA, which is the carboxylate analog of PFOS, revealed a very close KA value (3.41 × 1012) to PFOS. A greater KA value (1.43 × 1013) was obtained for PFBS, which possesses the same functional group and a smaller molecular size compared to PFOS. The presented platform emphasizes the necessity to develop new strategies to make MIP sensors more specific if practical applications are to be pursued.


Assuntos
Técnicas de Química Analítica/instrumentação , Poluentes Ambientais/análise , Poluentes Ambientais/química , Fluorocarbonos/análise , Fluorocarbonos/química , Polímeros Molecularmente Impressos/química , Alquilação , Eletrodos
2.
Eur Radiol Exp ; 3(1): 33, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31410624

RESUMO

BACKGROUND: Bone strain index (BSI) is a tool measuring bone strain, derived from dual x-ray photon absorptiometry. It is able to characterise an aspect of bone quality that, joined to the quantity and quality parameters of bone mineral density (BMD) and trabecular bone score (TBS), permits an accurate definition of fracture risk. As no data are available about BSI precision, our aim was to assess its in vitro reproducibility. METHODS: A Hologic spine phantom was used to perform BSI scans with three different scan modes: fast array (FA), array (A), and high definition (HD). Different soft tissue thicknesses (1, 3, 6 cm) of fresh pork rind layers as a surrogate of abdominal fat were interposed. For each scan mode, the phantom was consecutively scanned 25 times without repositioning. RESULTS: In all scan modes (FA, A, HD) and at every fat thickness, BSI reproducibility was lower than that of BMD. The highest reproducibility was found using HD-mode with 1 cm of pork rind and the lowest one using HD-mode with 6 cm of pork rind. Increasing fat thickness, BSI reproducibility tended to decrease. BSI least significant change appeared to be about three times that of BMD in all modalities and fat thicknesses. Without pork rind superimposition and with 1-cm fat layer, BSI reproducibility was highest with HD-mode; with 3 or 6 cm fat thickness, it was higher with A-mode. CONCLUSIONS: BSI reproducibility was worse than that of BMD, but it is less sensitive to fat thickness increase, similarly to TBS.


Assuntos
Gordura Abdominal/anatomia & histologia , Gordura Abdominal/diagnóstico por imagem , Absorciometria de Fóton/métodos , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/fisiologia , Imagens de Fantasmas , Animais , Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Tamanho do Órgão , Reprodutibilidade dos Testes , Suínos