Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 217
Filtrar
1.
Front Cardiovasc Med ; 11: 1285685, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476377

RESUMO

Coronary artery bypass grafting (CABG) is and continues to be the preferred revascularization strategy in patients with multivessel disease. Graft selection has been shown to influence the outcomes following CABG. During the last almost 60 years saphenous vein grafts (SVG) together with the internal mammary artery have become the standard of care for patients undergoing CABG surgery. While there is little doubt about the benefits, the patency rates are constantly under debate. Despite its acknowledged limitations in terms of long-term patency due to intimal hyperplasia, the saphenous vein is still the most often used graft. Although reendothelialization occurs early postoperatively, the process of intimal hyperplasia remains irreversible. This is due in part to the persistence of high shear forces, the chronic localized inflammatory response, and the partial dysfunctionality of the regenerated endothelium. "No-Touch" harvesting techniques, specific storage solutions, pressure controlled graft flushing and external stenting are important and established methods aiming to overcome the process of intimal hyperplasia at different time levels. Still despite the known evidence these methods are not standard everywhere. The use of arterial grafts is another strategy to address the inferior SVG patency rates and to perform CABG with total arterial revascularization. Composite grafting, pharmacological agents as well as latest minimal invasive techniques aim in the same direction. To give guide and set standards all graft related topics for CABG are presented in this expert opinion document on graft treatment.

2.
Cardiol Ther ; 13(1): 39-67, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38381282

RESUMO

Numerous genetic and epidemiologic studies have demonstrated an association between elevated levels of lipoprotein(a) (Lp[a]) and cardiovascular disease. As a result, lowering Lp(a) levels is widely recognized as a promising strategy for reducing the risk of new-onset coronary heart disease, stroke, and heart failure. Lp(a) consists of a low-density lipoprotein-like particle with covalently linked apolipoprotein A (apo[a]) and apolipoprotein B-100, which explains its pro-thrombotic, pro-inflammatory, and pro-atherogenic properties. Lp(a) serum concentrations are genetically determined by the apo(a) isoform, with shorter isoforms having a higher rate of particle synthesis. To date, there are no approved pharmacological therapies that effectively reduce Lp(a) levels. Promising treatment approaches targeting apo(a) expression include RNA-based drugs such as pelacarsen, olpasiran, SLN360, and lepodisiran, which are currently in clinical trials. In this comprehensive review, we provide a detailed overview of RNA-based therapeutic approaches and discuss the recent advances and challenges of RNA therapeutics specifically designed to reduce Lp(a) levels and thus the risk of cardiovascular disease.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38218725

RESUMO

OBJECTIVES: Patients with diabetes mellitus (DM) undergoing coronary artery bypass grafting (CABG) have been repeatedly demonstrated to have worse clinical outcomes compared to patients without DM. The objective of this study was to evaluate the impact of DM on 1-year clinical outcomes after isolated CABG. METHODS: The European DuraGraft registry included 1130 patients (44.6%) with and 1402 (55.4%) patients without DM undergoing isolated CABG. Intra-operatively, all free venous and arterial grafts were treated with an endothelial damage inhibitor. Primary end point in this analysis was the incidence of a major adverse cardiac event (MACE), a composite of all-cause death, repeat revascularization or myocardial infarction at 1 year post-CABG. To balance between differences in baseline characteristics (n = 1072 patients in each group), propensity score matching was used. Multivariable Cox proportional hazards regression was performed to identify independent predictors of MACE. RESULTS: Diabetic patients had a higher cardiovascular risk profile and EuroSCORE II with overall more comorbidities. Patients were comparable in regard to surgical techniques and completeness of revascularization. At 1 year, diabetics had a higher MACE rate {7.9% vs 5.5%, hazard ratio (HR) 1.43 [95% confidence interval (CI) 1.05-1.95], P = 0.02}, driven by increased rates of death [5.6% vs 3.5%, HR 1.61 (95% CI 1.10-2.36), P = 0.01] and myocardial infarction [2.8% vs 1.4%, HR 1.99 (95% CI 1.12-3.53) P = 0.02]. Following propensity matching, no statistically significant difference was found for MACE [7.1% vs 5.7%, HR 1.23 (95% CI 0.87-1.74) P = 0.23] or its components. Age, critical operative state, extracardiac arteriopathy, ejection fraction ≤50% and left main disease but not DM were identified as independent predictors for MACE. CONCLUSIONS: In this study, 1-year outcomes in diabetics undergoing isolated CABG were comparable to patients without DM.

4.
Transplantation ; 108(3): 634-642, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37389638

RESUMO

Aging affects immunity broadly through changes caused by immunosenescence, clinically resulting in augmented susceptibility to infections, autoimmunity, and cancer. The most striking alterations associated with immunosenescence have been observed in the T-cell compartment with a significant shift toward a terminally differentiated memory phenotype taking on features of innate immune cells. At the same time, cellular senescence impairs T-cell activation, proliferation, and effector functions, compromising the effectiveness of immunity. In clinical transplantation, T-cell immunosenescence has been the main driver of less frequent acute rejections in older transplant recipients. This patient population, at the same time, suffers more frequently from the side effects of immunosuppressive therapy including higher rates of infections, malignancies, and chronic allograft failure. T-cell senescence has also been identified as an instigator of age-specific organ dysfunction through a process that has been coined "inflammaging," accelerating organ injury and potentially contributing to the limited lifetime of organ transplants. Here, we provide a summary of the latest evidence on molecular characteristics of T-cell senescence affecting alloimmunity and organ quality while dissecting the consequences of unspecific organ injury and immunosuppression on T-cell senescence. Rather than conceptualizing immunosenescence as a broad and general "weaker" alloimmune response, it appears critical to understand both mechanisms and clinical effects in detail as a basis to refine treatment.


Assuntos
Imunossenescência , Transplante de Órgãos , Humanos , Idoso , Senescência de Células T , Envelhecimento/fisiologia , Imunossenescência/fisiologia , Senescência Celular , Transplante de Órgãos/efeitos adversos , Inflamação/etiologia
6.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37740952

RESUMO

OBJECTIVES: Despite the success of coronary artery bypass graft (CABG) surgery using autologous saphenous vein grafts (SVGs), nearly 50% of patients experience vein graft disease within 10 years of surgery. One contributing factor to early vein graft disease is endothelial damage during short-term storage of SVGs in inappropriate solutions. Our aim was to evaluate the effects of a novel endothelial damage inhibitor (EDI) on SVGs from patients undergoing elective CABG surgery and on venous endothelial cells (VECs) derived from these SVGs. METHODS: SVGs from 11 patients participating in an ongoing clinical registry (NCT02922088) were included in this study, and incubated with both full electrolyte solution (FES) or EDI for 1 h and then examined histologically. In 8 of 11 patients, VECs were isolated from untreated grafts, incubated with both FES and EDI for 2 h under hypothermic stress conditions and then analysed for activation of an inflammatory phenotype, cell damage and cytotoxicity, as well as endothelial integrity and barrier function. RESULTS: The EDI was superior to FES in protecting the endothelium in SVGs (74 ± 8% versus 56 ± 8%, P < 0.001). Besides confirming that the EDI prevents apoptosis in SVG-derived VECs, we also showed that the EDI temporarily reduces adherens junctions in VECs while protecting focal adhesions compared to FES. CONCLUSIONS: The EDI protects the connectivity and function of the SVG endothelium. Our data suggest that the EDI can preserve focal adhesions in VECs during short-term storage after graft harvesting. This might explain the superiority of the EDI in maintaining most of the endothelium in venous CABG surgery conduits.


Assuntos
Células Endoteliais , Doenças Vasculares , Humanos , Veia Safena/transplante , Grau de Desobstrução Vascular/fisiologia , Ponte de Artéria Coronária/efeitos adversos , Endotélio Vascular
8.
Front Med (Lausanne) ; 10: 1179145, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37425319

RESUMO

Objectives: Stethoscopes carry a significant risk for pathogen transmission. Here, the safe use and performance of a new, non-sterile, single-use stethoscope cover (SC), that is impermeable for pathogens, was investigated by different healthcare professionals (HCPs) in the postoperative care setting of an intensive care unit (ICU). Methods: Fifty-four patients underwent routine auscultations with the use of the SC (Stethoglove®, Stethoglove GmbH, Hamburg, Germany). The participating HCPs (n = 34) rated each auscultation with the SC on a 5-point Likert scale. The mean ratings of acoustic quality and the SC handling were defined as primary and secondary performance endpoint. Results: 534 auscultations with the SC were performed (average 15.7/user) on the lungs (36.1%), the abdomen (33.2%), the heart (28.8%), or other body-sites (1.9%). No adverse device-effects occurred. The acoustic quality was rated at 4.2 ± 0.7 (mean) with a total of 86.1% of all auscultations being rated at least as 4/5, and with no rating as below 2. The SC handling was rated at 3.7 ± 0.8 (mean) with a total of 96.4% of all auscultations being rated at least 3/5. Conclusion: Using a real-world setting, this study demonstrates that the SC can be safely and effectively used as cover for stethoscopes during auscultation. The SC may therefore represent a useful and easy-to-implement tool for preventing stethoscope-mediated infections.Study Registration: EUDAMED no. CIV-21-09-037762.

9.
J Thorac Dis ; 15(6): 3013-3024, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37426140

RESUMO

Background: Minimally invasive mitral valve surgery (MIV) through a right lateral thoracotomy has become the standard of care at specialized centers and might soon will be the only acceptable surgical treatment option in the future era of interventional procedures. The aim of our study was to analyze the outcomes of our MIV-specialized, single-center, mixed valve pathology cohort with regard to morbidity, mortality and midterm outcomes comparing two different repair techniques (respect versus resect). Methods: Baseline and operative variables, postoperative outcomes and follow-up information about survival, valve competence and freedom from reoperation were retrospectively collected and analyzed. The repair cohort was divided into three groups (resection, neo-chordae and both) and compared for outcomes. Results: Between July 22nd 2013 and May 31st 2022 a total of 278 consecutive patients underwent MIV. Out of those, we identified 165 eligible patients for the three repair groups: 82 patients (29.5%) had "resection", 66 "neo-chordae" (23.7%) and 17 "both" (6.1%). All preoperative variables were comparable between the groups. The predominant valve pathology of the entire cohort was degenerative disease with 20.5% Barlow's, 20.5% bi-leaflet and 32.4% double segment pathology. Bypass time was 164±47, cross-clamp time 106±36 minutes. All valves planned for repair (85.6%) were successfully repaired except for 13 resulting in a repair rate of 94.5%. Only 1 patient (0.4%) had to be converted to clamshell and 2 (0.7%) needed rethoracotomy for bleeding. Mean intensive care unit (ICU) stay was 1.8 days and hospital stay 10.6±1.3 days. In-hospital mortality was 1.1% and the incidence of stroke (1.8%). All in-hospital outcomes were comparable between the groups. Follow up was complete in 86.2% (n=237) for a mean of 3.7±0.8, up to 9 years. Five-year survival was 92.6% (P=0.5) and freedom from re-intervention 96.5% (P=0.1). All but 10 patients had mitral regurgitation less than grade 2 (95.8%, P=0.2) and all but two had less than New York Heart Association (NYHA) II (99.2%, P=0.1). Conclusions: Despite a heterogeneous cohort with mixed valve pathologies, there is a high reconstruction rate, low short- and midterm morbidity, mortality and need for re-intervention with comparable outcomes of the resect and respect technique in a specialized MIV center.

10.
Int J Mol Sci ; 24(13)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37445658

RESUMO

Heart failure is the leading cause of morbidity and mortality and currently affects more than 60 million people worldwide. A key feature in the pathogenesis of almost all forms of heart failure is cardiac fibrosis, which is characterized by excessive accumulation of extracellular matrix components in the heart. Although cardiac fibrosis is beneficial in the short term after acute myocardial injury to preserve the structural and functional integrity of the heart, persistent cardiac fibrosis contributes to pathological cardiac remodeling, leading to mechanical and electrical dysfunction of the heart. Despite its high prevalence, standard therapies specifically targeting cardiac fibrosis are not yet available. Cell-based approaches have been extensively studied as potential treatments for cardiac fibrosis, but several challenges have been identified during clinical translation. The observation that extracellular vesicles (EVs) derived from stem and progenitor cells exhibit some of the therapeutic effects of the parent cells has paved the way to overcome limitations associated with cell therapy. However, to make EV-based products a reality, standardized methods for EV production, isolation, characterization, and storage must be established, along with concrete evidence of their safety and efficacy in clinical trials. This article discusses EVs as novel therapeutics for cardiac fibrosis from a translational perspective.


Assuntos
Cardiomiopatias , Vesículas Extracelulares , Insuficiência Cardíaca , Humanos , Cardiomiopatias/patologia , Coração , Insuficiência Cardíaca/patologia , Vesículas Extracelulares/patologia , Fibrose
11.
JACC Basic Transl Sci ; 8(5): 546-564, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37325404

RESUMO

Continuous measurement of vascular and hemodynamic parameters could improve monitoring of disease progression and enable timely clinical decision making and therapy surveillance in patients suffering from cardiovascular diseases. However, no reliable extravascular implantable sensor technology is currently available. Here, we report the design, characterization, and validation of an extravascular, magnetic flux sensing device capable of capturing the waveforms of the arterial wall diameter, arterial circumferential strain, and arterial pressure without restricting the arterial wall. The implantable sensing device, comprising a magnet and a magnetic flux sensing assembly, both encapsulated in biocompatible structures, has shown to be robust, with temperature and cyclic-loading stability. Continuous and accurate monitoring of arterial blood pressure and vascular properties was demonstrated with the proposed sensor in vitro with a silicone artery model and validated in vivo in a porcine model mimicking physiologic and pathologic hemodynamic conditions. The captured waveforms were further used to deduce the respiration frequency, the duration of the cardiac systolic phase, and the pulse wave velocity. The findings of this study not only suggest that the proposed sensing technology is a promising platform for accurate monitoring of arterial blood pressure and vascular properties, but also highlight the necessary changes in the technology and the implantation procedure to allow the translation of the sensing device in the clinical setting.

13.
Pediatr Cardiol ; 44(5): 973-995, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37149833

RESUMO

Patch augmentation of the right ventricular outflow tract (RVOT) and pulmonary artery (PA) arterioplasty are relatively common procedures in the surgical treatment of patients with congenital heart disease. To date, several patch materials have been applied with no agreed upon clinical standard. Each patch type has unique performance characteristics, cost, and availability. There are limited data describing the various advantages and disadvantages of different patch materials. We performed a review of studies describing the clinical performance of various RVOT and PA patch materials and found a limited but growing body of literature. Short-term clinical performance has been reported for a multitude of patch types, but comparisons are limited by inconsistent study design and scarce histologic data. Standard clinical criteria for assessment of patch efficacy and criteria for intervention need to be applied across patch types. The field is progressing with improvements in outcomes due to newer patch technologies focused on reducing antigenicity and promoting neotissue formation which may have the ability to grow, remodel, and repair.


Assuntos
Cardiopatias Congênitas , Tetralogia de Fallot , Obstrução do Fluxo Ventricular Externo , Humanos , Artéria Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Ventrículos do Coração/cirurgia , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Resultado do Tratamento , Tetralogia de Fallot/cirurgia
14.
Int J Mol Sci ; 24(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36982261

RESUMO

The adult human heart cannot regain complete cardiac function following tissue injury, making cardiac regeneration a current clinical unmet need. There are a number of clinical procedures aimed at reducing ischemic damage following injury; however, it has not yet been possible to stimulate adult cardiomyocytes to recover and proliferate. The emergence of pluripotent stem cell technologies and 3D culture systems has revolutionized the field. Specifically, 3D culture systems have enhanced precision medicine through obtaining a more accurate human microenvironmental condition to model disease and/or drug interactions in vitro. In this study, we cover current advances and limitations in stem cell-based cardiac regenerative medicine. Specifically, we discuss the clinical implementation and limitations of stem cell-based technologies and ongoing clinical trials. We then address the advent of 3D culture systems to produce cardiac organoids that may better represent the human heart microenvironment for disease modeling and genetic screening. Finally, we delve into the insights gained from cardiac organoids in relation to cardiac regeneration and further discuss the implications for clinical translation.


Assuntos
Organoides , Células-Tronco Pluripotentes , Adulto , Humanos , Miócitos Cardíacos , Medicina Regenerativa/métodos
15.
Int J Surg ; 109(4): 707-715, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36912566

RESUMO

OBJECTIVES: The objective of the European Multicenter Registry to Assess Outcomes in coronary artery bypass grafting (CABG) patients (DuraGraft Registry) was to determine clinical outcomes and quality of life (QoL) after contemporary CABG that included isolated CABG and combined CABG/valve procedures, using an endothelial damage inhibitor (DuraGraft) intraoperatively for conduit preservation. Here, we report outcomes in the patient cohort undergoing isolated CABG. METHODS: The primary outcome was the composite of all-cause death, myocardial infarction (MI), or repeat revascularization (RR) [major adverse cardiac events (MACE)] at 1 year. Secondary outcomes included the composite of all-cause death, MI, RR, or stroke [major adverse cardiac and cerebrovascular events (MACCE)], and QoL. QoL was assessed with the EuroQol-5 Dimension questionnaire. Independent risk factors for MACE at 1 year were determined using Cox regression analysis. RESULTS: A total of 2532 patients (mean age, 67.4±9.2 years; 82.5% male) underwent isolated CABG. The median EuroScore II was 1.4 [interquartile range (IQR), 0.9-2.3]. MACE and MACCE rates at 1 year were 6.6% and 7.8%, respectively. The rates of all-cause death, MI, RR, and stroke were 4.4, 2.0, 2.2, and 1.9%, respectively. The 30-day mortality rate was 2.3%. Age, extracardiac arteriopathy, left ventricular ejection fraction less than 50%, critical operative state, and left main disease were independent risk factors for MACE. QoL index values improved from 0.84 [IQR, 0.72-0.92] at baseline to 0.92 [IQR, 0.82-1.00] at 1 year ( P <0.0001). CONCLUSION: Contemporary European patients undergoing isolated CABG have a low 1-year clinical event rate and an improved QoL.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Qualidade de Vida , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Acidente Vascular Cerebral/etiologia
16.
Stem Cells Transl Med ; 12(2): 72-82, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36806699

RESUMO

Cardiovascular disease is a major cause of morbidity and mortality worldwide and, to date, the clinically available prostheses still present several limitations. The design of next-generation regenerative replacements either based on cellular or extracellular matrix technologies can address these shortcomings. Therefore, tissue engineered constructs could potentially become a promising alterative to the current therapeutic options for patients with cardiovascular diseases. In this review, we selectively present an overview of the current tissue engineering tools such as induced pluripotent stem cells, biomimetic materials, computational modeling, and additive manufacturing technologies, with a focus on their application to translational cardiovascular therapies. We discuss how these advanced technologies can help the development of biomimetic tissue engineered constructs and we finally summarize the latest clinical evidence for their use, and their potential therapeutic outcome.


Assuntos
Doenças Cardiovasculares , Células-Tronco Pluripotentes Induzidas , Humanos , Engenharia Tecidual , Biomimética , Doenças Cardiovasculares/terapia , Matriz Extracelular
18.
Front Cardiovasc Med ; 9: 953582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277782

RESUMO

Thrombogenicity remains a major issue in cardiovascular implants (CVIs). Complete surficial coverage of CVIs by a monolayer of endothelial cells (ECs) prior to implantation represents a promising strategy but is hampered by the overall logistical complexity and the high number of cells required. Consequently, extensive cell expansion is necessary, which may eventually lead to replicative senescence. Considering that micro-structured surfaces with anisotropic topography may promote endothelialization, we investigated the impact of gratings on the biomechanical properties and the replicative capacity of senescent ECs. After cultivation on gridded surfaces, the cells showed significant improvements in terms of adherens junction integrity, cell elongation, and orientation of the actin filaments, as well as enhanced yes-associated protein nuclear translocation and cell proliferation. Our data therefore suggest that micro-structured surfaces with anisotropic topographies may improve long-term endothelialization of CVIs.

19.
Front Cardiovasc Med ; 9: 971028, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36186971

RESUMO

Cardiovascular (CV) implants are still associated with thrombogenicity due to insufficient hemocompatibility. Endothelialization of their luminal surface is a promising strategy to increase their hemocompatibility. In this review, we provide a collection of research studies and review articles aiming to summarize the recent efforts on surface modifications of CV implants, including stents, grafts, valves, and ventricular assist devises. We focus in particular on the implementation of micrometer or nanoscale surface modifications, physical characteristics of known biomaterials (such as wetness and stiffness), and surface morphological features (such as gratings, fibers, pores, and pits). We also review how biomechanical signals originating from the endothelial cell for surface interaction can be directed by topography engineering approaches toward the survival of the endothelium and its long-term adaptation. Finally, we summarize the regulatory and economic challenges that may prevent clinical implementation of endothelialized CV implants.

20.
Front Vet Sci ; 9: 949410, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36118338

RESUMO

Aortic insufficiency caused by paravalvular leakage (PVL) is one of the most feared complications following transcatheter aortic valve replacement (TAVI) in patients. Domestic pigs (Sus scrofa domestica) are a popular large animal model to study such conditions and develop novel diagnostic and therapeutic techniques. However, the models based on prosthetic valve implantation are time intensive, costly, and often hamper further hemodynamic measurements such as PV loop and 4D MRI flow by causing implantation-related wall motion abnormalities and degradation of MR image quality. This study describes in detail, the establishment of a minimally invasive porcine model suitable to study the effects of mild-to-moderate "paravalvular" aortic regurgitation on left ventricular (LV) performance and blood flow patterns, particularly under the influence of altered afterload, preload, inotropic state, and heart rate. Six domestic pigs (Swiss large white, female, 60-70 kg of body weight) were used to establish this model. The defects on the hinge point of aortic leaflets and annulus were created percutaneously by the pierce-and-dilate technique either in the right coronary cusp (RCC) or in the non-coronary cusp (NCC). The hemodynamic changes as well as LV performance were recorded by PV loop measurements, while blood flow patterns were assessed by 4D MRI. LV performance was additionally challenged by pharmaceutically altering cardiac inotropy, chronotropy, and afterload. The presented work aims to elaborate the dos and don'ts in porcine models of aortic insufficiency and intends to steepen the learning curve for researchers planning to use this or similar models by giving valuable insights ranging from animal selection to vascular access choices, placement of PV Loop catheter, improvement of PV loop data acquisition and post-processing and finally the induction of paravalvular regurgitation of the aortic valve by a standardized and reproducible balloon induced defect in a precisely targeted region of the aortic valve.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...