1.
Chemosphere ; 72(1): 95-103, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18313102

RESUMO

A 96-microwell enzyme-linked immunosorbent assay (ELISA) method was evaluated to determine PCDDs/PCDFs in sediment and soil samples from an EPA Superfund site. Samples were prepared and analyzed by both the ELISA and a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. Comparable method precision, accuracy, and detection level (8 ng kg(-1)) were achieved by the ELISA method with respect to GC/HRMS. However, the extraction and cleanup method developed for the ELISA requires refinement for the soil type that yielded a waxy residue after sample processing. Four types of statistical analyses (Pearson correlation coefficient, paired t-test, nonparametric tests, and McNemar's test of association) were performed to determine whether the two methods produced statistically different results. The log-transformed ELISA-derived 2,3,7,8-tetrachlorodibenzo-p-dioxin values and log-transformed GC/HRMS-derived TEQ values were significantly correlated (r=0.79) at the 0.05 level. The median difference in values between ELISA and GC/HRMS was not significant at the 0.05 level. Low false negative and false positive rates (<10%) were observed for the ELISA when compared to the GC/HRMS at 1,000 ng TEQ kg(-1). The findings suggest that immunochemical technology could be a complementary monitoring tool for determining concentrations at the 1,000 ng TEQ kg(-1) action level for contaminated sediment and soil. The ELISA could also be used in an analytical triage approach to screen and rank samples prior to instrumental analysis.


Assuntos
Dioxinas/análise , Ensaio de Imunoadsorção Enzimática/métodos , Sedimentos Geológicos/química , Poluentes do Solo/análise , Cromatografia Gasosa-Espectrometria de Massas
2.
Talanta ; 67(3): 658-66, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970221

RESUMO

An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

3.
Talanta ; 63(5): 1213-23, 2004 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-18969550

RESUMO

Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the growing demand for rapid and low cost analysis. In this work, we describe the application of an immunoassay that uses 2,3,7-trichloro-8-methyldibenzo-p-dioxin (TMDD) as a surrogate standard for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) to sediment and human serum samples. Sample extraction and preparation methods were developed with the aim to establish the simplest, cost-effective and efficient removal of the matrix interferences in the enzyme-linked immunosorbent assay (ELISA). The overall method for sediments is based on a hexane extraction; clean up by a multilayered silica gel column and an activated carbon column; an organic solvent exchange with DMSO-Triton X-100 and ELISA measurement. The gas chromatography-high resolution mass spectrometry (GC-HRMS) validation studies (n = 13) revealed that the method is suitable for the toxic equivalents (TEQ) screening of dioxin in sediments with a method detection limit of about 100pgg(-1) dry sediment with a precision of 13-33% R.S.D. The analysis of a large number of samples originating from different sources would be required to establish more precisely the screening level, as well as the number of false positives and negatives of dioxin TEQ by the immunoassay for sediments. The immunoassay method for sediment analysis offers improvement in speed, sample throughput, and cost in comparison to GC-HRMS. Dioxins were determined in serum samples after a simple liquid-liquid extraction and solvent exchange into DMSO-Triton X-100 without further dilution. The current method (approximate method LOQ of 200pgml(-1) serum) is not sufficiently sensitive for the determination of dioxins in serum to measure acceptable exposure limit.