Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 88(3): 033301, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372389

RESUMO

We demonstrate techniques to improve the accuracy of the energy calibration of Timepix pixel detectors, used for the measurement of energetic particles. The typical signal from such particles spreads among many pixels due to charge sharing effects. As a consequence, the deposited energy in each pixel cannot be reconstructed unless the detector is calibrated, limiting the usability of such signals for calibration. To avoid this shortcoming, we calibrate using low energy X-rays. However, charge sharing effects still occur, resulting in part of the energy being deposited in adjacent pixels and possibly lost. This systematic error in the calibration process results in an error of about 5% in the energy measurements of calibrated devices. We use FLUKA simulations to assess the magnitude of charge sharing effects, allowing a corrected energy calibration to be performed on several Timepix pixel detectors and resulting in substantial improvement in energy deposition measurements. Next, we address shortcomings in calibration associated with the huge range (from kiloelectron-volts to megaelectron-volts) of energy deposited per pixel which result in a nonlinear energy response over the full range. We introduce a new method to characterize the non-linear response of the Timepix detectors at high input energies. We demonstrate improvement using a broad range of particle types and energies, showing that the new method reduces the energy measurement errors, in some cases by more than 90%.

2.
Phys Rev Lett ; 115(23): 231802, 2015 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-26684111

RESUMO

Borexino is a liquid scintillation detector located deep underground at the Laboratori Nazionali del Gran Sasso (LNGS, Italy). Thanks to the unmatched radio purity of the scintillator, and to the well understood detector response at low energy, a new limit on the stability of the electron for decay into a neutrino and a single monoenergetic photon was obtained. This new bound, τ≥6.6×10^{28} yr at 90% C.L., is 2 orders of magnitude better than the previous limit.

3.
Adv Space Res ; 35(2): 214-22, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15934197

RESUMO

The modeling of ion transport and interactions in matter is a subject of growing interest, driven by the continuous increase of possible application fields. These include hadron therapy, dosimetry, and space missions, but there are also several issues involving fundamental research, accelerator physics, and cosmic ray physics, where a reliable description of heavy ion induced cascades is important. In the present work, the capabilities of the FLUKA code for ion beams will be briefly recalled and some recent developments presented. Applications of the code to the simulation of therapeutic carbon, nitrogen and oxygen ion beams, and of iron beams, which are of direct interest for space mission related experiments, will be also presented together with interesting consideration relative to the evaluation of dosimetric quantities. Both applications involve ion beams in the AGeV range.


Assuntos
Simulação por Computador , Radiação Cósmica , Modelos Teóricos , Radioterapia , Carbono , Íons , Ferro , Transferência Linear de Energia , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Polimetil Metacrilato , Doses de Radiação , Monitoramento de Radiação/instrumentação , Voo Espacial
4.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 113-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16604609

RESUMO

The FLUKA Monte Carlo code has been evolving over the last several decades and is now widely used for radiation shielding calculations. In order to facilitate the use of FLUKA in dosimetry and therapy applications, supporting software has been developed to allow the direct conversion of the output files from standard CT-scans directly into a voxel geometry for transport within FLUKA. Since the CT-scan information essentially contains only the electron density information over the scanned volume, one needs the specific compositions for each voxel individually. We present here the results of a simple algorithm to assign tissues in the human body to one of four categories: soft-tissue, hard-bone, trabecular-bone and porous-lung. In addition, we explore the problem of the pathlength distributions in porous media such as trabecular bone. A mechanism will be implemented within FLUKA to allow for variable multipal fixed density materials to accommodate the pathlength distributions discovered.


Assuntos
Neoplasias Ósseas/radioterapia , Modelos Biológicos , Proteção Radiológica/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Tecidos Moles/radioterapia , Software , Algoritmos , Simulação por Computador , Humanos , Modelos Estatísticos , Método de Monte Carlo , Dosagem Radioterapêutica , Espalhamento de Radiação , Interface Usuário-Computador
5.
Adv Space Res ; 34(6): 1302-10, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15881773

RESUMO

The FLUKA Monte Carlo transport code is widely used for fundamental research, radioprotection and dosimetry, hybrid nuclear energy system and cosmic ray calculations. The validity of its physical models has been benchmarked against a variety of experimental data over a wide range of energies, ranging from accelerator data to cosmic ray showers in the earth atmosphere. The code is presently undergoing several developments in order to better fit the needs of space applications. The generation of particle spectra according to up-to-date cosmic ray data as well as the effect of the solar and geomagnetic modulation have been implemented and already successfully applied to a variety of problems. The implementation of suitable models for heavy ion nuclear interactions has reached an operational stage. At medium/high energy FLUKA is using the DPMJET model. The major task of incorporating heavy ion interactions from a few GeV/n down to the threshold for inelastic collisions is also progressing and promising results have been obtained using a modified version of the RQMD-2.4 code. This interim solution is now fully operational, while waiting for the development of new models based on the FLUKA hadron-nucleus interaction code, a newly developed QMD code, and the implementation of the Boltzmann master equation theory for low energy ion interactions.


Assuntos
Simulação por Computador , Radiação Cósmica , Interações de Partículas Elementares , Modelos Teóricos , Método de Monte Carlo , Meio Ambiente Extraterreno , Íons Pesados , Matemática , Nêutrons , Física Nuclear , Atividade Solar , Voo Espacial
6.
Phys Rev Lett ; 90(23): 232502, 2003 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-12857252

RESUMO

High-energy, cw electron beams at new accelerator facilities allow electromagnetic production and precision study of hypernuclear structure, and we report here on the first experiment demonstrating the potential of the (e,e'K+) reaction for hypernuclear spectroscopy. This experiment is also the first to take advantage of the enhanced virtual photon flux available when electrons are scattered at approximately zero degrees. The observed energy resolution was found to be approximately 900 keV for the (12)(Lambda)B spectrum, and is substantially better than any previous hypernuclear experiment using magnetic spectrometers. The positions of the major excitations are found to be in agreement with a theoretical prediction and with a previous binding energy measurement, but additional structure is also observed in the core excited region, underlining the future promise of this technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...