Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 177: 111599, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38970995

RESUMO

PURPOSE: This study aims to develop Various Age-size Pediatric Chest Phantoms (VAPC) to evaluate low-dose protocol that approximates clinical conditions achieved by low organ-specific doses and optimal image quality among the challenges of pediatric size variations. METHODS: Three original pediatric data aged 1, 4, and 7 years were used as a reference for developing VAPC phantoms. Six protocols, namely standard dose (STD) and low dose (low mA and low kV) reconstructed using Filtered Back Projection (FBP) and iterative reconstruction (IR) algorithms, were investigated. This study directly measured the lungs, heart, and spinal cord dose using LD-V1 film. Linearity, Modulation Transfer Function (MTF), Contrast to Noise Ratio (CNR), and Noise Power Spectrum (NPS) were evaluated to assess the CT image quality of the VAPC phantom. RESULTS: This study found that the mean organ-specific dose was higher than CTDIvol. A Comparison of mean lung doses showed VAPC phantom 1 (y.o.) received 74.8% and 137.2% more doses than 4 (y.o.) and 7 (y.o.), respectively. Low kV produces a lower organ dose than low mA. The linearity of CT numbers is not biased at low doses. Differences in age measures significantly influenced organ-specific dose, MTF, CNR, and NPS. CONCLUSION: Smaller pediatrics are still exposed to higher doses at low-dose examinations, whereas larger pediatrics have lower contrast resolution and increased image noise. CT number linearity is unbiased. The combination of low kV with FBP produces higher spatial resolution, while low mA with IR effectively reduces noise to detect low-contrast objects better.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica , Tomografia Computadorizada por Raios X , Humanos , Criança , Pré-Escolar , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Lactente , Masculino , Feminino , Algoritmos , Pulmão/diagnóstico por imagem
2.
Diabetes Metab Syndr Obes ; 17: 2203-2209, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854446

RESUMO

Background: Type 1 diabetes mellitus (T1DM) is the most common chronic disease in children, with several severe short and long-term complications. Glycemic control is an important aspect of diabetes management with the most influential factor being compliance with self-monitoring blood glucose (SMBG). Mostly, in Indonesia, the finger stick devices as a glucose monitoring tool were frequently used. About 20% of children follow the recommendation to measure blood glucose four to six times daily. Methods: This is a single center, cross-sectional study that was conducted between July-November 2022. The Population is children with T1DM at the Pediatric Outpatient Clinic of Dr. Soetomo Hospital, Surabaya, Indonesia. Children with T1DM aged 4-18 years were enrolled using consecutive sampling. A compliance questionnaire was used to assess SMBG. Psychosocial conditions were assessed using the Pediatric Symptom Checklist 17, and medication adherence was evaluated using the Adherence to Refills and Medications Scale for Diabetes (ARMS-D). Pearson correlation and linear regression were employed for statistical analyses using Statistical Package for Social Sciences version 21.0, with p < 0.05 indicating statistical significance. Results: A total of 36 children were included in this study. SMBG frequency over 4x per day was significantly associated with increased medication adherence as measured by the ARMS-D score (p = 0.012). Higher SMBG frequency was also correlated with decreased HbA1c (p = 0.014, r = 0.406) and nutritional status (p = 0.031, r = 0.360). Less than 50% of the patients in Indonesia adhered to the recommended guidelines for SMBG (ie, ≥4 times per day). Conclusion: Higher SMBG frequency was correlated with better glycemic control. This finding suggests the need for further support in conducting SMBG based on the national guideline. However, due to it being conducted in a single center, we suggest increasing the sample size or conducting multi-centre collaborations in future studies. Originality/Value: By specifically investigating the relationship between adherence to self-monitoring of blood glucose (SMBG) and glycemic control in children with type 1 diabetes mellitus (T1DM), our study represents a novel contribution to the field of pediatric diabetes management in Indonesia. While previous research has explored similar relationships in other populations, our study focuses exclusively on the unique context of Indonesia, where rates of adherence to SMBG in pediatric patients have not been well studied and are relatively low compared to global standards.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA