1.
Cancers (Basel) ; 16(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38730652

RESUMO

BACKGROUND: The accurate delineation of ablation zones (AZs) is crucial for assessing radiofrequency ablation (RFA) therapy's efficacy. Manual measurement, the current standard, is subject to variability and potential inaccuracies. AIM: This study aims to assess the effectiveness of Artificial Intelligence (AI) in automating AZ measurements in ultrasound images and compare its accuracy with manual measurements in ultrasound images. METHODS: An in vitro study was conducted using chicken breast and liver samples subjected to bipolar RFA. Ultrasound images were captured every 15 s, with the AI model Mask2Former trained for AZ segmentation. The measurements were compared across all methods, focusing on short-axis (SA) metrics. RESULTS: We performed 308 RFA procedures, generating 7275 ultrasound images across liver and chicken breast tissues. Manual and AI measurement comparisons for ablation zone diameters revealed no significant differences, with correlation coefficients exceeding 0.96 in both tissues (p < 0.001). Bland-Altman plots and a Deming regression analysis demonstrated a very close alignment between AI predictions and manual measurements, with the average difference between the two methods being -0.259 and -0.243 mm, for bovine liver and chicken breast tissue, respectively. CONCLUSION: The study validates the Mask2Former model as a promising tool for automating AZ measurement in RFA research, offering a significant step towards reducing manual measurement variability.

2.
Diagnostics (Basel) ; 14(3)2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38337854

RESUMO

Breast conserving resection with free margins is the gold standard treatment for early breast cancer recommended by guidelines worldwide. Therefore, reliable discrimination between normal and malignant tissue at the resection margins is essential. In this study, normal and abnormal tissue samples from breast cancer patients were characterized ex vivo by optical emission spectroscopy (OES) based on ionized atoms and molecules generated during electrosurgical treatment. The aim of the study was to determine spectroscopic features which are typical for healthy and neoplastic breast tissue allowing for future real-time tissue differentiation and margin assessment during breast cancer surgery. A total of 972 spectra generated by electrosurgical sparking on normal and abnormal tissue were used for support vector classifier (SVC) training. Specific spectroscopic features were selected for the classification of tissues in the included breast cancer patients. The average classification accuracy for all patients was 96.9%. Normal and abnormal breast tissue could be differentiated with a mean sensitivity of 94.8%, a specificity of 99.0%, a positive predictive value (PPV) of 99.1% and a negative predictive value (NPV) of 96.1%. For 66.6% patients all classifications reached 100%. Based on this convincing data, a future clinical application of OES-based tissue differentiation in breast cancer surgery seems to be feasible.

3.
Diagnostics (Basel) ; 13(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37958243

RESUMO

Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60-65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.

4.
Pathologie (Heidelb) ; 44(Suppl 3): 183-187, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37966557

RESUMO

Over the last century, there has been a steady development of new technologies for intraoperative tissue identification and differentiation. The applications are varied, with the core purpose being to identify target structures while preserving adjacent tissue and thereby follow a general paradigm of minimally invasive medicine. Particularly in oncology, a further asset of these technologies is the identification or classification of neoplastic tissue to support and improve therapy, for example, in breast cancer surgery.Many technologies under consideration make use of the different physical characteristics of treated tissues, such as induced fluorescence, optical coherence, and electrical impedance.Recent developments are focusing on moving from ex vivo to in situ and from asynchronous to real-time assistance of the clinicians, for example, by means of optical emission spectroscopy. Refinements of existing and the creation of new methods will include AI tools to make them more powerful while reducing the inter-operator variability in operative interventions. This talk addresses several aspects of the usage and suitability of these technologies for intraoperative, therapy-supporting application.


Assuntos
Neoplasias da Mama , Mama , Humanos , Feminino , Mama/cirurgia , Neoplasias da Mama/cirurgia
5.
Cancers (Basel) ; 15(14)2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37509365

RESUMO

Immunological consequences of endoscopic ultrasound (EUS)-local thermal ablation (LTA) for pancreatic ductal adenocarcinoma (PDAC) have not been extensively assessed. We aimed to explore EUS-LTA effects on the systemic immune response in PDAC. Peripheral blood was collected from 10 treatment-naïve patients with borderline resectable and locally advanced PDAC, randomly allocated to Nab-paclitaxel plus Gemcitabine chemotherapy (CT-arm, n = 5) or EUS-LTA with HybridTherm Probe plus CT (HTP + CT-arm, n = 5). Twenty healthy donors were included as controls. Flow-cytometry and multiplex assays were used to profile immune cell subsets and measure serum cytokines/chemokines, respectively. At baseline, PDAC patients showed increased circulating monocytes and lower circulating lymphocytes and CD19+ B cells counts compared to healthy controls. After 4 months, CT induced decrease of B regulatory cells, CD4+ cytotoxic T cells and IL-1ß. The addition of EUS-HTP to CT selectively decreased the serum levels of APRIL/TNFSF13 as well as T regulatory cells, total, classic and inflammatory monocytes. Serum levels of APRIL/TNFSF13 and total, classic and inflammatory monocytes counts at baseline were associated with worse overall survival. EUS-HTP has the potential to selectively impact on immune cells and cytokines associated with poor outcomes in PDAC.

6.
VideoGIE ; 8(4): 158-161, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37095838

RESUMO

Video 1Case description and video in cholangioscopic view demonstrating bile duct tissue acquisition by cholangioscopy-guided cryobiopsy technique.

7.
Arch Gynecol Obstet ; 307(1): 187-194, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35284956

RESUMO

PURPOSE: Endometriosis is a benign, but potentially serious gynaecological condition in terms of abdominal pain and impaired fertility. Laparoscopic excision techniques are considered the therapeutic standard. HybridAPC is presented as a novel technique for the non-contact thermal ablation of peritoneal endometriosis with simultaneous protection of the underlying thermosensitive structures by creating a needle-free elevated fluid cushion which enables a safer exposure and distance, as well as potentially improved peritoneal conditioning prior to APC. METHODS: In this prospective randomized clinical trial, 39 patients with 132 superficial endometriotic lesions in total were treated with HybridAPC or sharp excision in an initial laparoscopic procedure according to randomization. In a second-look laparoscopy, adhesion formation was rated macroscopically. Histologic samples were taken from previously treated areas for evaluation of eradication rate. RESULTS: The eradication rate was not significantly different between HybridAPC treatment and sharp excision (65 vs. 81%, p = .55). Adhesions formed in 5% of HybridAPC-treated lesions and in 10% after sharp excision (p = .49). HybridAPC treatment was significantly faster than sharp excision (69 vs. 106 s, p < .05). No intra- and postoperative complications were registered. CONCLUSION: This clinical trial demonstrates the feasibility of this novel surgical technique with a promising impact on adhesion prevention. Compared to sharp excision, HybridAPC is likely to be a safe, tissue-preserving, and fast method for the treatment of peritoneal endometriosis.


Assuntos
Endometriose , Laparoscopia , Feminino , Humanos , Endometriose/cirurgia , Endometriose/patologia , Coagulação com Plasma de Argônio , Estudos Prospectivos , Peritônio/patologia , Laparoscopia/métodos , Aderências Teciduais/prevenção & controle , Aderências Teciduais/cirurgia , Aderências Teciduais/patologia
8.
Minim Invasive Ther Allied Technol ; 31(8): 1131-1139, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36260701

RESUMO

INTRODUCTION: A novel multipurpose bipolar radiofrequency instrument, the Erbe Dissector (EDS), which simultaneously seals and cuts tissue, was developed. Ex vivo sealing rate and time, burst pressure, jaw temperature and thermal spread were studied in porcine renal arteries. MATERIAL AND METHODS: In vivo, 13 surgical tasks were performed in two pigs: beside sealing rate and time, overall performance in sharp and blunt dissection, tissue sticking, hemostasis, precision, etc., were evaluated by four surgeons compared with ENSEAL G2 (EG2) using surveys on a Likert scale (1 = very poor; 5 = very good). RESULTS: Ex vivo, the EDS sealing rate was 91.7% (33/36 arteries) at an average sealing time of 2.1 s (range 1.7-2.8) and a burst pressure of 1040 ± 350 mmHg. The maximum jaw temperature was 87 ± 4 °C and the mean lateral thermal spread was 0.8 ± 0.2 mm. In vivo, the sealing rate for arteries and veins was 92.6% (50/54) and the median seal and cut time was 1.6 s (range: 1.3-2.9). The average EDS performance score across all tasks was 4.4 ± 0.6 Likert points. For five shared tasks, EDS was better than EG2 (4.4 ± 0.5 versus 3.4 ± 0.6 Likert points; p = 0.016). CONCLUSIONS: EDS seals and cuts arteries and veins rapidly with good safety and user-friendliness.


Assuntos
Hemostasia Cirúrgica , Artéria Renal , Suínos , Animais , Artéria Renal/cirurgia , Veias/cirurgia , Ligadura , Eletrocoagulação
9.
Endosc Ultrasound ; 11(5): 383-392, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36255026

RESUMO

Background and Objectives: Data on the clinical efficacy of EUS-guided ablation using the HybridTherm-Probe (EUS-HTP) in locally advanced pancreatic ductal adenocarcinoma (LA-PDAC) are lacking. The aim of the study was to assess the impact of EUS-HTP added to chemotherapy (CT) on overall survival (OS) and progression-free survival (PFS) of LA-PDAC patients with local disease progression (DP) after first-line therapy, compared to CT alone in controls. Methods: LA-PDAC cases, prospectively treated by EUS-HTP, were retrospectively compared to matched controls (1:2) receiving standard treatment. Study endpoints were the OS and PFS from local DP after first-line therapy, compared through log-rank test calculating hazard ratios and differences in restricted mean OS/PFS time (RMOST/RMPFST) within prespecified time points (4, 6, and 12 months). Results: Thirteen cases and 26 controls were included. Clinical, tumor, and therapy features before and after first-line therapy were case-control balanced. The median OS and PFS were not significantly improved in cases over controls (months: 7 vs. 5 and 5 vs. 3, respectively). At 4 and 6 months, the RMPFST difference was in favor of cases (P = 0.0001 and P = 0.003, respectively). In cases and controls not candidate to further CT (N = 5 and N = 9), the median OS and PFS were not significantly improved in cases over controls (months: 6 vs. 3 and 4 vs. 2, respectively), but the RMPFST difference was in favor of cases at 4 months (P = 0.002). Conclusions: In locally progressive PDAC patients experiencing failure of first-line therapy, EUS-HTP achieves a significantly better RMPFST up to 6 months compared to standard treatment, although without a significant impact on OS.

10.
World J Gastroenterol ; 28(29): 4007-4018, 2022 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-36157546

RESUMO

BACKGROUND: Complete polyp resection is the main goal of endoscopic removal of large colonic polyps. Resection techniques have evolved in recent years and endoscopic submucosal dissection (ESD), endoscopic mucosal resection (EMR) with margin ablation, cold snare polypectomy (CSP), cold EMR, and underwater EMR have been introduced. Yet, efficacy of these techniques with regard to local recurrence rates (LRRs) vs traditional hot snare polypectomy and standard EMR remains unclear. AIM: To analyze LRR of large colonic polyps in a systematic review and meta-analysis. METHODS: MEDLINE, EMBASE, EBM Reviews, and CINAHL were searched for prospective studies reporting LRR or incomplete resection rate (IRR) after colonic polypectomy of polyps ≥ 10 mm, published between January 2011 and July 2021. Primary outcome was LRR for polyps ≥ 10 mm. RESULTS: Six thousand nine hundred and twenty-eight publications were identified, of which 34 prospective studies were included. LRR for polyps ≥ 10 mm at up to 12 mo' follow-up was 11.0% (95%CI, 7.1%-14.8%; 15 studies; 4904 polyps). ESD (1.7%; 95%CI, 0%-3.4%; 3 studies, 221 polyps) and endoscopic mucosal resection with margin ablation (3.3%; 95%CI, 2.2%-4.5%; 2 studies, 947 polyps) significantly reduced LRR vs standard EMR without (15.2%; 95%CI, 12.5%-18.0%; 4 studies, 650 polyps) or with unsystematic margin ablation (16.5%; 95%CI, 15.2%-17.8%; 6 studies, 3031 polyps). CONCLUSION: LRR is significantly lower after ESD or EMR with routine margin ablation; thus, these techniques should be considered standard for endoscopic removal of large colorectal polyps. Other techniques, such as CSP, cold EMR, and underwater EMR require further evaluation in prospective studies before their routine implementation in clinical practice can be recommended.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Pólipos do Colo/cirurgia , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Humanos , Margens de Excisão , Estudos Prospectivos , Resultado do Tratamento
11.
Endosc Int Open ; 10(6): E809-E814, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35692925

RESUMO

Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method for tissue extraction already used in different clinical settings. The aim of this ex vivo clinical study was to investigate feasibility and tissue quality of cryobiopsy in the bile duct. Patients and methods We included 14 patients who underwent pancreaticoduodenectomy. Bile duct samples were taken with either a new prototype cryoprobe or one of two forceps types. Results were analyzed for general feasibility, specimen size, histological assessability as well as representativity of retrieved tissue. Results Feasibility of cholangioscopic forceps was poor compared to gastric biopsy forceps or cryobiopsy. Significantly larger tissue samples were obtained with cryobiopsy (5.6 ±â€Š4.5 mm 2 ) compared to gastric biopsy forceps (3.3 ±â€Š5.1 mm 2 , P  = 0.006). Furthermore, cryobiopsy was superior in histological assessment quality ( P  = 0.02) and concerning representativity ( P  = 0.03). Conclusions Cryobiopsy in the bile duct is feasible and the quality of the obtained tissue is high. Further investigation of bile duct cryobiopsy in vivo is warranted.

12.
Biomedicines ; 10(5)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35625838

RESUMO

(1) Development of radiofrequency ablation (RFA) systems for pulmonary lesions is restricted by availability of human tumor specimens and limited comparability of animal tissue. We aimed to develop a new surrogate tissue overcoming these drawbacks. (2) Reference values for electrical impedance in lung tumor tissue were collected during routine lung tumor RFA (n = 10). Subsequently, a tissue-mimicking surrogate with comparable electrical impedance and facilitating detection of the ablation margins was developed. (3) The mean electrical impedance for all patients was 103.5 ± 14.7 Ω. In the optimized surrogate tissue model consisting of 68% agar solution, 23% egg yolk, 9% thermochromic ink, and variable amounts of sodium chloride, the mean electrical impedance was adjustable from 74.3 ± 0.4 Ω to 183.2 ± 5.6 Ω and was a function (y = 368.4x + 175.2; R2 = 0.96; p < 0.001) of sodium chloride concentration (between 0 and 0.3%). The surrogate tissue achieved sufficient dimensional stability, and sample cuts revealed clear margins of color change for temperatures higher 60 °C. (4) The tissue-mimicking surrogate can be adapted to lung tumor with respect to its electrical properties. As the surrogate tissue allows for simple and cost-effective manufacturing, it is suitable for extensive laboratory testing of RFA systems for pulmonary ablation.

13.
Cancers (Basel) ; 14(8)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35454839

RESUMO

(1) Background: Cervical intraepithelial neoplasia (CIN) of long-term persistence or associated with individual treatment indications often requires highly invasive treatments. These are associated with risks of bleeding, infertility, and pregnancy complications. For low- and middle-income countries (LMICs), standard treatment procedures are difficult to implement and manage. We characterized the application of the highly energized gas "noninvasive physical plasma" (NIPP) for tissue devitalization and the treatment of CIN. (2) Methods: We report the establishment of a promising tissue devitalization procedure by NIPP application. The procedure was characterized at the in vitro, ex vivo and in vivo levels. We performed the first prospective, single-armed phase-IIb trial in 20 CIN1/2 patients (NCT03218436). (3) Results: NIPP-treated cervical cancer cells used as dysplastic in vitro model exhibited significant cell growth retardation due to DNA damage, cell cycle arrest and apoptosis. Ex vivo and in vivo tissue assessments showed a highly noninvasive and tissue-preserving treatment procedure which induces transmucosal tissue devitalization. Twenty participants were treated with NIPP and attended a 24-week follow-up. Treatment success was achieved in 19 (95%) participants without postinterventional complications other than mild to moderate discomfort during application. (4) Conclusions: The results from this study preliminarily suggest that NIPP could be used for an effective and tissue-preserving treatment for CIN without the disadvantages of standard treatments. However, randomized controlled trials must confirm the efficacy and noninferiority of NIPP compared to standard treatments.

14.
Cell Transplant ; 31: 9636897221080943, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35466714

RESUMO

Current regimen to treat patients suffering from stress urinary incontinence often seems not to yield satisfactory improvement or may come with severe side effects. To overcome these hurdles, preclinical studies and clinical feasibility studies explored the potential of cell therapies successfully and raised high hopes for better outcome. However, other studies were rather disappointing. We therefore developed a novel cell injection technology to deliver viable cells in the urethral sphincter complex by waterjet instead of using injection needles. We hypothesized that the risk of tissue injury and loss of cells could be reduced by a needle-free injection technology. Muscle-derived cells were obtained from young male piglets and characterized. Upon expansion and fluorescent labeling, cells were injected into cadaveric tissue samples by either waterjet or injection needle. In other experiments, labeled cells were injected by waterjet in the urethra of living pigs and incubated for up to 7 days of follow-up. The analyses documented that the cells injected by waterjet in vitro were viable and proliferated well. Upon injection in live animals, cells appeared undamaged, showed defined cellular somata with distinct nuclei, and contained intact chromosomal DNA. Most importantly, by in vivo waterjet injections, a significantly wider cell distribution was observed when compared with needle injections (P < .05, n ≥ 12 samples). The success rates of waterjet cell application in living animals were significantly higher (≥95%, n = 24) when compared with needle injections, and the injection depth of cells in the urethra could be adapted to the need by adjusting waterjet pressures. We conclude that the novel waterjet technology injects viable muscle cells in tissues at distinct and predetermined depth depending on the injection pressure employed. After waterjet injection, loss of cells by full penetration or injury of the tissue targeted was reduced significantly in comparison with our previous studies employing needle injections.


Assuntos
Células Musculares , Agulhas , Animais , Humanos , Masculino , Músculos , Suínos , Tecnologia , Uretra
15.
Front Oncol ; 12: 810367, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35223492

RESUMO

OBJECTIVE: The quality of histopathological specimens obtained from the upper urinary tract with conventional flexible ureterorenoscopic biopsy needs to be improved. We investigated the feasibility and biopsy quality of specimens obtained by cryobiopsy, compared with standard ureterorenoscopic biopsy techniques in a human ex vivo model. MATERIALS AND METHODS: Human ureters obtained from nephrectomy specimens (N=12) were dissected and canulated with an ureteral access sheath. Ureterorenoscopic biopsies were randomly obtained from different sites of the renal pelvic caliceal system using different types of instruments. The performance of two newly developed flexible cryoprobes with outer diameters of 1.1 mm (CB11) and 0.9 mm (CB09) was compared with that of the biopsy forceps(FB) and Bigopsy®(BiG) and two different Dormia baskets N-Gage (NG) and Zero-Tip (ZT). We assessed the feasibility of the various biopsy techniques based on the number of biopsy attempts needed to obtain macroscopically discernible biopsies. The specimens were examined histopathologically for size, biopsy quality, presence of various artifact types, and representativeness. RESULTS: Biopsies taken with the cryoprobes showed a higher biopsy quality than biopsies taken with the comparative instruments. The CB11 provided significantly larger biopsies than forceps biopsies and also than biopsies with ZT. The CB09 was able to collect larger samples when compared with the FB and BiG biopsy forceps. There were no significant differences in artifact area, except for the CB11 cryoprobe compared with the NG. To clarify the results a subdivision of larger or smaller than 20% artifact area was performed. A significant difference was found between CB11 and the forceps biopsies, as well as between CB11 and NG and ZT in favor of the cryoprobe. The representation of the histopathological sample was also determined. Biopsies taken with CB11 were more representative compared with forceps biopsies BiG and FB and basket biopsies NG and ZT. CONCLUSIONS: In a standardized comparative ex vivo setting, larger biopsies were obtained by using the cryobiopsy technique with the CB11 probe. Qualitatively, cryobiopsy specimens were overlaid by fewer artifacts and a higher biopsy quality was achieved in histopathologic examination compared with standard instrumentation. Further stepwise development will transfer the promising cryobiopsy technique into the clinical setting.

16.
Interact Cardiovasc Thorac Surg ; 34(5): 775-782, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35137083

RESUMO

OBJECTIVES: Evaluation of smoke capture efficiency of different mobile smoke evacuation devices with respect to volatile organic compounds and their noise emission. METHODS: Electrosurgical incisions were performed on fresh porcine liver in an operating room with vertical laminar flow. The generated surgical smoke was analysed with proton-transfer-reaction mass spectrometry with and without the use of a mobile smoke evacuation system consisting of a smoke evacuator machine, a suction hose and a handpiece. The inlet of the mass spectrometer was positioned 40 cm above the specimen. Various devices were compared: a hard plastic funnel, a flexible foam funnel, an on-tip integrated aspirator of an electrosurgical knife and a standard secretion suction (Yankauer). Also, sound levels were measured at a distance of 40 cm from the handpieces' inlet. RESULTS: The smoke capture efficiency of the secretion suction was only 53%, while foam funnel, plastic funnel and integrated aspirator were all significantly more effective with a clearance of 95%, 91% and 91%, respectively. The mean sound levels were 68 and 59 A-weighted decibels with the plastic and foam funnel, respectively, 66 A-weighted decibels with the integrated aspirator and 63 A-weighted decibels with the secretion suction. CONCLUSIONS: Carcinogenic, mutagenic and reprotoxic volatile organic compounds in surgical smoke can be efficiently reduced by mobile smoke evacuation system, providing improved protection for medical personnel. Devices specifically designed for smoke evacuation are more efficient than standard suction tools. Noise exposure for the surgeon was lowest with the flexible foam funnel and higher with the other handpieces tested.


Assuntos
Exposição Ocupacional , Saúde Ocupacional , Compostos Orgânicos Voláteis , Animais , Eletrocoagulação/métodos , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Salas Cirúrgicas , Plásticos , Fumaça/efeitos adversos , Fumaça/análise , Fumaça/prevenção & controle , Suínos , Compostos Orgânicos Voláteis/análise
17.
Obes Surg ; 32(2): 381-390, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34797503

RESUMO

BACKGROUND AND AIMS: As the pig model has similar gastrointestinal anatomy and physiology to humans, we used pigs to create a gastric mucosal devitalization (GMD) model in preparation for clinical translation of this technique as an endoscopic bariatric therapy (EBT). The aims of this study were to determine the ablation parameters and technique for a successful, safe, and feasible large surface area GMD that produces weight loss. METHODS: We performed GMD using argon plasma coagulation (APC) in 3 phases. Phase 1 assessed the ablation energy required to accomplish selective mucosal ablation using ex vivo pig stomachs (n = 2). Phase 2 assessed the optimal percentage of mucosal surface area to be treated and was performed on 10 pigs. Phase 3 assessed feasibility, efficacy, and safety with 8 pigs randomized into GMD (n = 4) or sham (SH, n = 4) and survived for 1 month. Body weights (GMD, n = 4, SH, n = 4) were measured daily in phase 3 for 1 month, and relative body weights were calculated and analyzed using one-tailed Student's t-test. Percent body fat was compared between GMD and SH at baseline and 1 month post-GMD. RESULTS: Phase 1 identified the optimal ablation parameters (120 W) that were then used in phase 2. Phase 2 revealed a trend that was suggestive that the optimal percent surface area to ablate was similar to that which is removed at laparoscopic sleeve gastrectomy. In phase 3, GMD was performed over 70% surface area of the greater curvature of the stomach in four pigs. GMD pigs had significantly lower relative body weight increase compared to SH at 1 month (1.375 ± 0.085 vs 1.575 ± 0.047, p = 0.0435). MRI showed a significantly lower body fat mass at 1 month in GMD pigs (5.9 ± 0.4% vs 12.7 ± 2.3%, p = 0.026) compared to SH. CONCLUSIONS: GMD resulted in decreased weight gain in the GMD group as evidenced by a lower relative body weight at 1 month. GMD in an animal model appears to show promise as a potential weight loss therapy.


Assuntos
Laparoscopia , Obesidade Mórbida , Animais , Gastrectomia/métodos , Mucosa Gástrica/cirurgia , Humanos , Obesidade Mórbida/cirurgia , Estômago/cirurgia , Suínos , Aumento de Peso , Redução de Peso
18.
J Vis Exp ; (177)2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34897276

RESUMO

Urinary incontinence (UI) is a highly prevalent condition characterized by the deficiency of the urethral sphincter muscle. Regenerative medicine branches, particularly cell therapy, are novel approaches to improve and restore the urethral sphincter function. Even though injection of active functional cells is routinely performed in clinical settings by needle and syringe, these approaches have significant disadvantages and limitations. In this context, needle-free waterjet (WJ) technology is a feasible and innovative method that can inject viable cells by visual guided cystoscopy in the urethral sphincter. In the present study, we used WJ to deliver porcine adipose tissue-derived stromal cells (pADSCs) into cadaveric urethral tissue and subsequently investigated the effect of WJ delivery on cell yield and viability. We also assessed the biomechanical features (i.e., elasticity) by atomic force microscopy (AFM) measurements. We showed that WJ delivered pADSCs were significantly reduced in their cellular elasticity. The viability was significantly lower compared to controls but is still above 80%.


Assuntos
Tecido Adiposo , Células Estromais , Animais , Humanos , Injeções/métodos , Masculino , Suínos , Tecnologia , Uretra
19.
Ann Gastroenterol ; 34(6): 845-851, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34815651

RESUMO

BACKGROUND: Thermal damage to the muscle layer during mucosal application of argon plasma coagulation (APC) may be avoided by creating a fluid cushion within the submucosal layer, but the minimum injection volume needed or the ideal injection fluid are yet to be established. We conducted a systematic ex vivo study with this aim. METHODS: All experiments were performed in an ex vivo porcine gastrointestinal tract model. Five different fluids (saline, Glyceol, Gelafundin, Voluven, and Eleview) of different volumes were injected into the submucosa of different parts of the gastrointestinal tract. APC was applied to the mucosa at different power settings. Immediately after APC treatment, the temperature was measured through a thermocouple placed inside the fluid cushion, just on top of the muscle layer. The minimum volume of fluid needed to protect the muscle layer from thermal damage was determined. RESULTS: There was no difference in the temperature measured among the different injection fluids at the surface of the muscle, in all the locations, at equal injection volumes and power settings. The minimum amounts of fluid needed to protect the muscle layer were 2 and 3 mL for power settings of 30-90 W and 90-120 W, respectively. CONCLUSIONS: Normal saline and 4 commercially available submucosal injection fluids possess similar thermal protective effects. To reduce the likelihood of thermal damage to deeper layers when APC is applied, a minimum injection volume of 3 mL is recommended if less than 90 W power will be utilized over 3 sec.

20.
Cancers (Basel) ; 13(18)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34572743

RESUMO

Endoscopic ultrasound-ablation with HybridTherm-Probe (EUS-HTP) significantly reduces tumour volume (TV) in locally-advanced pancreatic ductal adenocarcinoma (LA-PDAC). We aimed at investigating the clinical efficacy of EUS-HTP plus chemotherapy versus chemotherapy (HTP-CT and CT arms) in LA- and borderline-resectable (BR) PDAC, with 6-months progression-free survival (6-PFS) rate as primary endpoint. In a phase-II randomized-controlled-trial, 33 LA/BR-PDAC patients per-arm were planned to verify 20% improved 6-PFS rate. Radiological response (Choi criteria), TV and serum CA19.9 were assessed up to 6-months. Seventeen and 20 LA/BR-PDAC patients were randomized to HTP-CT or CT. Baseline and CT-related features were balanced. At 6-months, 6-PFS rate was 41.2% and 30% in HTP-CT and CT arms (p = 0.48), respectively. A decrease ≥50% of serum CA19.9 was achieved in 75% and 64.3% of HTP-CT and CT patients (p = 0.53), respectively. TV reduced up to 6-months in 64.3% and 47.1% of HTP-CT and CT patients (p = 0.35), respectively. Resection rate, PFS-time and overall survival (OS-time) were similar. HTP-CT achieves a non-significant 11.2%, 10.7% and 17.2% improved 6-PFS, CA19.9 decrease ≥50% and TV reduction rates over CT, without any impact on resection rate, PFS-time and OS-time. As the study was underpowered, these results suggest further investigation of EUS-local ablation in selected patients with localized disease after induction CT.