Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 21(8): 081212, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27311423

RESUMO

Changes within the microcirculation can provide an early indication of the onset of a plethora of ailments. Various techniques have thus been developed that enable the study of microcirculatory irregularities. Correlation mapping optical coherence tomography (cmOCT) is a recently proposed technique, which enables mapping of vasculature networks at the capillary level in a noninvasive and noncontact manner. This technique is an extension of conventional optical coherence tomography (OCT) and is therefore likewise limited in the penetration depth of ballistic photons in biological media. Optical clearing has previously been demonstrated to enhance the penetration depth and the imaging capabilities of OCT. In order to enhance the achievable maximum imaging depth, we propose the use of optical clearing in conjunction with the cmOCT technique. We demonstrate in vivo a 13% increase in OCT penetration depth by topical application of a high-concentration fructose solution, thereby enabling the visualization of vessel features at deeper depths within the tissue.


Assuntos
Frutose , Processamento de Imagem Assistida por Computador/métodos , Microcirculação/fisiologia , Pele , Tomografia de Coerência Óptica/métodos , Administração Tópica , Adulto , Frutose/administração & dosagem , Frutose/química , Frutose/farmacologia , Humanos , Masculino , Imagens de Fantasmas , Pele/irrigação sanguínea , Pele/diagnóstico por imagem , Pele/efeitos dos fármacos
2.
J Biophotonics ; 6(9): 663-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23616445

RESUMO

We propose the use of correlation mapping optical coherence tomography (cmOCT) to deliver additional biometrics associated with the finger that could complement existing fingerprint technology for law enforcement applications. The current study extends the existing fingerprint paradigm by measuring additional biometrics associated with sub-surface finger tissue such as sub-surface fingerprints, sweat glands, and the pattern of the capillary bed to yield a user-friendly cost effective and anti-spoof multi-mode biometric solution associated with the finger. To our knowledge no other method has been able to capture sub-surface fingerprint, papillary pattern and horizontal vessel pattern in a single scan or to show the correspondence between these patterns in live adult human fingertip. Unlike many current technologies this approach incorporates 'liveness' testing by default. The ultimate output is a biometric module which is difficult to defeat and complements fingerprint scanners that currently are used in border control and law enforcement applications.


Assuntos
Identificação Biométrica/métodos , Dermatoglifia , Fraude/prevenção & controle , Tomografia de Coerência Óptica , Estudos de Viabilidade , Humanos , Propriedades de Superfície
3.
J Biophotonics ; 4(9): 583-7, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21887769

RESUMO

Standard optical coherence tomography (OCT) in combination with software tools can be harnessed to generate vascular maps in vivo. In this study we have successfully combined a software algorithm based on correlation statistic to reveal microcirculation morphology on OCT intensity images of a mouse brain in vivo captured trans-cranially and through a cranial window. We were able to estimate vessel geometry at bifurcation as well as along vessel segments down-to mean diameters of about 24 µm. Our technique has potential applications in cardiovascular-related parameter measurements such as volumetric flow as well as in assessing vascular density of normal and diseased tissue.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/patologia , Processamento de Imagem Assistida por Computador/métodos , Microcirculação , Tomografia de Coerência Óptica/métodos , Algoritmos , Animais , Encéfalo/metabolismo , Sistema Cardiovascular/metabolismo , Sistema Cardiovascular/patologia , Camundongos , Sensibilidade e Especificidade , Software
4.
Biomed Opt Express ; 2(5): 1184-93, 2011 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-21559130

RESUMO

Correlation mapping optical coherence tomography (cmOCT) is a recently proposed technique that extends the capabilities of OCT to enable mapping of vasculature networks. The technique is achieved as a processing step on OCT intensity images that does not require any modification to existing OCT hardware. In this paper we apply the cmOCT processing technique to in vivo human imaging of the volar forearm. We illustrate that cmOCT can produce maps of the microcirculation that clearly follow the accepted anatomical structure. We demonstrate that the technique can extract parameters such as capillary density and vessel diameter. These parameters are key clinical markers for the early changes associated with microvascular diseases. Overall the presented results show that cmOCT is a powerful new tool that generates microcirculation maps in a safe non-invasive, non-contact technique which has clear clinical applications.

5.
Arch Dermatol Res ; 303(2): 79-87, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20524004

RESUMO

In routine clinical phototesting and in basic research, naked eye dermatological assessment is the "gold standard" for determining the patient's minimal erythemal dose (MED). In UV-B testing with a divergent, radially attenuating beam of characterised dosimetry, laser Doppler perfusion imaging has been previously used to give quantitative description of reactivity to doses above the MED in addition to a "single-dose" objective determination of the MED itself. In the present paper, the recently developed tissue viability imaging (TiVi) technology is presented for the first time as a reliable, easily applicable, high-resolution alternative to LDPI in the divergent beam testing concept. Data obtained after provocation with a range of doses was analysed in order to determine the reaction diameter, which can be related to the MED using field dosimetry. The dose-response features of exposure above the MED and the relationship between naked eye readings and the diameter were determined from the image data. TiVi data were obtained faster than LDPI data and at a higher spatial resolution of 100 µm instead of 1 mm. A tool was developed to centre over the erythema area of the acquired image. Response data could be plotted continuously against dose. Thresholding of processed images compared to naked eye "gold standard" readings showed that the normal skin value +4 standard deviations produced a good fit between both methods. A linear fitting method for the dose-response data provided a further method of determination of the reaction diameter (MED). Erythemal "volume under the surface (VUS)" for the reaction provided a new concept for visualising information. TiVi offers advantages over LDPI in the acquisition and analysis of data collected during divergent beam testing. An increased amount of data compared to traditional phototesting is easily and more objectively obtained which increases applicability in the clinical and research environment.


Assuntos
Diagnóstico por Imagem/métodos , Eritema/diagnóstico , Sobrevivência de Tecidos , Raios Ultravioleta , Adulto , Relação Dose-Resposta à Radiação , Eritema/etiologia , Eritema/fisiopatologia , Feminino , Humanos , Fluxometria por Laser-Doppler/métodos , Masculino , Microcirculação , Pessoa de Meia-Idade , Imagem de Perfusão , Fotobiologia/métodos , Pele/irrigação sanguínea
6.
J Biomed Opt ; 15(4): 046001, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20799803

RESUMO

The use of microneedles as a method of circumventing the barrier properties of the stratum corneum is receiving much attention. Although skin disruption technologies and subsequent transdermal diffusion rates are being extensively studied, no accurate data on depth and closure kinetics of microneedle-induced skin pores are available, primarily due to the cumbersome techniques currently required for skin analysis. We report on the first use of optical coherence tomography technology to image microneedle penetration in real time and in vivo. We show that optical coherence tomography (OCT) can be used to painlessly measure stratum corneum and epidermis thickness, as well as microneedle penetration depth after microneedle insertion. Since OCT is a real-time, in-vivo, nondestructive technique, we also analyze skin healing characteristics and present quantitative data on micropore closure rate. Two locations (the volar forearm and dorsal aspect of the fingertip) have been assessed as suitable candidates for microneedle administration. The results illustrate the applicability of OCT analysis as a tool for microneedle-related skin characterization.


Assuntos
Agulhas , Fenômenos Fisiológicos da Pele , Pele/citologia , Tomografia de Coerência Óptica/métodos , Animais , Módulo de Elasticidade/fisiologia , Dureza/fisiologia , Miniaturização , Suínos
7.
J Biomed Opt ; 14(3): 034025, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19566318

RESUMO

The use of laser Doppler perfusion imaging (LDPI) and laser speckle perfusion imaging (LSPI) is well known in the noninvasive investigation of microcirculatory blood flow. This work compares the two techniques with the recently developed tissue viability (TiVi) imaging system, which is proposed as a useful tool to quantify red blood cell concentration in microcirculation. Three systems are evaluated with common skin tests such as the use of vasodilating and vasoconstricting drugs (methlynicotinate and clobetasol, respectively) and a reactive hyperaemia maneuver (using a sphygmomanometer). The devices investigated are the laser Doppler line scanner (LDLS), the laser speckle perfusion imager (FLPI)-both from Moor Instruments (Axminster, United Kingdom)-and the TiVi imaging system (WheelsBridge AB, Linkoping, Sweden). Both imaging and point scanning by the devices are used to quantify the provoked reactions. Perfusion images of vasodilatation and vasoconstriction are acquired with both LDLS and FLPI, while TiVi images are acquired with the TiVi imager. Time acquisitions of an averaged region of interest are acquired for temporal studies such as the reactive hyperaemia. In contrast to the change in perfusion over time with pressure, the TiVi imager shows a different response due its measurement of blood concentration rather than perfusion. The responses can be explained by physiological understanding. Although the three devices sample different compartments of tissue, and output essentially different variables, comparisons can be seen between the three systems. The LDLS system proves to be suited to measurement of perfusion in deeper vessels, while FLPI and TiVi showed sensitivity to more superficial nutritional supply. LDLS and FLPI are insensitive to the action of the vasoconstrictor, while TiVi shows the clear boundaries of the reaction. Assessment of the resolution, penetration depth, and acquisition rate of each instrument show complimentary features that should be taken into account when choosing a system for a particular clinical measurement.


Assuntos
Eritrócitos/fisiologia , Fluxometria por Laser-Doppler/métodos , Microcirculação/fisiologia , Imagem de Perfusão/métodos , Pele/irrigação sanguínea , Adulto , Analgésicos/farmacologia , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Contagem de Eritrócitos , Eritrócitos/efeitos dos fármacos , Mãos/irrigação sanguínea , Humanos , Hiperemia/sangue , Microcirculação/efeitos dos fármacos , Ácidos Nicotínicos/farmacologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sobrevivência de Tecidos , Vasoconstritores/farmacologia , Vasodilatadores/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...