Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Semin Cardiothorac Vasc Anesth ; : 10892532241260535, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864441

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) with MitraClip is a safe and effective alternative to surgical mitral valve repair/replacement in patients with high operative risk. Pleth Variability Index (PVI) is a non-invasive, dynamic index based on analysis of the respiratory variations in the plethysmographic waveform recorded transcutaneously by the pulse oximeter. OBJECTIVES: The objective of the study was to evaluate if the hemodynamic effect of improved left-sided output after successful transcatheter mitral valve repair would lead to a significant change in PVI, and if it would correlate with the decrease in left atrial pressure (LAP). DESIGN: Prospective, observational cohort study (ClinicalTrials.gov NCT03993938). SETTING: Single academic hospital in Detroit, Michigan (USA), from October 2019 to February 2021. PARTICIPANTS: The authors included adult patients with severe mitral regurgitation who underwent successful MitraClip placement. MEASUREMENTS AND MAIN RESULTS: Of 30 patients, all components of the LAP (a wave, v wave, and mean) decreased significantly after successful MitraClip placement (P < .01). The median (IQR) PVI increased from 21 (11-35) to 23 (13-38) after clip placement; however, this change was not statistically significant (P = .275). No significant correlation between change in PVI and change in LAP was observed (P = .235). CONCLUSIONS: In patients with severe mitral regurgitation, successful MitraClip resulted in a significant reduction in LAP without a significant change in PVI. A larger sample size may provide more insight on the utility of using PVI as an indicator of LAP change in patients with mitral regurgitation.

3.
Circ Cardiovasc Interv ; : e013558, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38785079

RESUMO

BACKGROUND: Elevated aortic valve gradients are common after transcatheter aortic valve implantation for degenerated surgical aortic valve replacement bioprostheses, but their clinical impact is uncertain. METHODS: A total of 12 122 patients who underwent transcatheter aortic valve implantation-in-surgical aortic valve replacement from November 2011 to December 2019 in the Society of Thoracic Surgery/American College of Cardiology Transvalvular Therapeutics Registry were included. The primary outcome was a composite of 1-year all-cause mortality, stroke, myocardial infarction, or valve reintervention. Secondary outcomes included 1-year all-cause mortality, readmission, and change from baseline 12-question self-administered Kansas City Cardiomyopathy Questionnaire-Overall Summary Score. Due to nonlinearity observed with restricted cubic splines analysis, a Cox regression analysis with aortic valve mean gradient modeled as a spline-continuous variable (with 20 mm Hg as a cutoff) was used to study the 1-year composite outcome and mortality. RESULTS: The composite outcome occurred most frequently in patients with aortic valve mean gradient ≥30 and <10 mm Hg, as compared with those with 10 to 20 and 20 to 30 mm Hg ranges (unadjusted rates, 13.9%, 12.1%, 7.5%, and 6.5%, respectively; P=0.002). When the mean aortic valve gradient was ≥20 mm Hg, higher gradients were associated with greater risk of the 1-year composite outcome (adjusted hazard ratio, 1.02 [1.02-1.03] per mm Hg; P<0.001) and 1-year mortality (adjusted hazard ratio, 1.02 [1.00-1.03] per mm Hg; P=0.007). Whereas when the mean aortic valve gradient was <20 mm Hg, higher gradients were not significantly associated with the composite outcome (adjusted hazard ratio, 0.99 [0.98-1.003] per mm Hg; P=0.12) but were associated with lower 1-year mortality (adjusted hazard ratio, 0.98 [0.97-0.99] per mm Hg; P=0.007). CONCLUSIONS: The relationship between postprocedural aortic valve mean gradient after transcatheter aortic valve implantation-in-surgical aortic valve replacement and clinical outcomes is complex and nonlinear, with relatively greater adverse events occurring at low and high gradient extremes. Further study of factors mediating the relationship between postprocedural gradients and clinical outcomes, including low-flow states, is necessary.

4.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599690

RESUMO

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/métodos
5.
Interv Cardiol Clin ; 13(2): 207-216, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432763

RESUMO

Reintervention is commonly required postsurgical mitral valve replacement (SMVR) or repair due to bioprosthetic valve and annuloplasty ring degeneration. However, redo SMVR is associated with a high risk of morbidity and mortality. Postsurgical transcatheter mitral valve replacement (TMVR) is a safe and less-invasive alternative that has repeatedly been shown to be associated with improved survival and lower rates of complications compared with redo SMVR. Comprehensive patient evaluation and thorough procedural planning are key to successful TMVR.


Assuntos
Catéteres , Valva Mitral , Humanos , Valva Mitral/cirurgia
6.
Interv Cardiol Clin ; 13(2): 227-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432765

RESUMO

Mitral valve dysfunction is prevalent amongst older patients. Of those not suitable for surgical therapy, mitral transcatheter edge-to-edge repair (TEER) can treat as large proportion of patients, many are not suitable TEER candidates. As such, orthotopic transcatheter mitral valve replacement (TMVR) is an important innovation but it faces significant challenges. Orthotopic TMVR requires a prosthesis with stable anchoring, adequate sealing, minimal footprint in the left ventricle and long term durability. Multidisciplinary expertise in advanced imaging, surgery, heart failure are needed for success.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ventrículos do Coração , Implantação de Prótese
7.
8.
Interv Cardiol Clin ; 12(4): ix, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37673501
10.
Interv Cardiol Clin ; 12(3): xi, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37290847
11.
Cardiovasc Revasc Med ; 55: 99-100, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37290992

RESUMO

Mitral valve endocarditis complicated by peri-mitral annular destruction requires surgical intervention. We present a case where surgery was not an option. A 45-year-old man who developed an enlarging left ventricle pseudoaneurysm, left ventricle to left atrium fistula and red blood cell hemolysis as sequalae of mitral valve endocarditis was not a surgical candidate. Patient underwent a hybrid repair of left ventricle pseudoaneurysm via a transapical and transseptal approach. The body of pseudoaneurysm was coiled trans-apically whereas the neck of pseudoaneurysm was reached and coiled via a transseptal approach. The left ventricle to left atrium fistula was closed via an Amplatz muscular ventricle septal occluder. The pseudoaneurysm was fully obliterated, patient symptoms improved and was discharged with stable hemoglobin levels.


Assuntos
Falso Aneurisma , Endocardite , Fístula , Estenose da Valva Mitral , Masculino , Humanos , Pessoa de Meia-Idade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Fístula/complicações
12.
J Vasc Surg Cases Innov Tech ; 9(2): 101108, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37181477

RESUMO

Chronic distal thoracic dissections treated with thoracic endovascular repair are prone to type Ib false lumen perfusion. When the supraceliac aorta is of normal caliber, fenestration of the dissection flap proximal to the visceral vessels creates a seal zone for the thoracic stent graft and eliminates the type Ib false lumen perfusion. We describe a novel way of crossing the septum using electrocautery delivered through a wire tip then fenestrating the septum using electrocautery delivered over a 1-mm area of uninsulated wire to cut the septum. We believe the use of electrocautery creates a controlled and deliberate aortic fenestration during endovascular repair of a distal thoracic dissections.

13.
Interv Cardiol Clin ; 12(2): xiii, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36922070
15.
J Thorac Cardiovasc Surg ; 165(6): 2011-2020.e5, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34538638

RESUMO

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement since its approval, the frequency and outcomes of aortic valve reintervention after transcatheter aortic valve replacement are poorly understood. METHODS: Valve reinterventions, either surgical transcatheter aortic valve explantation or repeat transcatheter aortic valve replacement, between 2012 and 2019 were queried using the Society of Thoracic Surgeons Database and the Transcatheter Valve Therapy Registry through the Michigan Statewide quality collaborative. The reintervention frequency and clinical outcomes including observed-to-expected mortality ratio using Society of Thoracic Surgeons Predicted Risk of Mortality were reviewed. RESULTS: Among 9694 transcatheter aortic valve replacement recipients, a total of 87 patients (0.90%) received a reintervention, consisting of 34 transcatheter aortic valve explants and 53 repeat transcatheter aortic valve replacement procedures. The transcatheter aortic valve explant group demonstrated a higher Society of Thoracic Surgeons Predicted Risk of Mortality. Reintervention cases increased from 0 in 2012 and 2013 to 26 in 2019. The proportion of transcatheter aortic valve explants among all reinterventions increased and was 65% in 2019. Self-expandable devices had a higher reintervention rate than balloon-expandable devices secondary to a higher transcatheter aortic valve explant frequency (0.58% [23/3957] vs 0.19% [11/5737]; P = .001), whereas repeat transcatheter aortic valve replacement rates were similar (0.61% [24/3957] vs 0.51% [29/5737]; P = .51). Among patients with transcatheter aortic valve explants, contraindications to repeat transcatheter aortic valve replacement included unfavorable anatomy (75%), need for other cardiac surgery (29%), other structural issues by transcatheter aortic valve device (18%), and endocarditis (12%). For transcatheter aortic valve explant and repeat transcatheter aortic valve replacement, the 30-day mortality was 15% and 2% (P = .032) and the observed-to-expected mortality ratio was 1.8 and 0.3 (P = .018), respectively. CONCLUSIONS: Aortic valve reintervention remains rare but is increasing. The clinical impact of surgical device explantation was substantial, and the proportion of transcatheter aortic valve explants was significantly higher in patients with a self-expandable device.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
16.
Interv Cardiol Clin ; 12(1): xiii, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36372466
17.
Interv Cardiol Clin ; 11(4): xi, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36243492
18.
Catheter Cardiovasc Interv ; 100(3): 437-438, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36084190
19.
Curr Cardiol Rep ; 24(10): 1417-1424, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35980565

RESUMO

PURPOSE OF REVIEW: Repeat surgery for failed mitral valve prostheses and repairs are fraught with high rates of morbidity and mortality. Therefore, clinicians have evolved transcatheter technology as an alternative therapy. This review serves as an update as the field has moved out of the early learning curve of treating postsurgical mitral valve failures. RECENT FINDINGS: Mitral valve-in-valve procedures have higher rates of technical success and better in-hospital and 1-year mortality rates than mitral valve-in-ring cases. The higher rates of complications, including left ventricular outflow tract obstruction, paravalvular leak, valve embolization, and need for a 2nd valve, may explain these outcomes. Mitral valve-in-ring procedures have attenuated outcomes as compared to valve-in-valve. Clinicians should be cognizant of the nuanced complexities and the potential for suboptimal outcomes in using balloon-expandable valves for mitral valve-in-ring procedures.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Falha de Prótese , Instrumentos Cirúrgicos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...