Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
BMC Geriatr ; 24(1): 141, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38326734

RESUMO

BACKGROUND: Osteosarcopenia is a common geriatric syndrome with an increasing prevalence with age, leading to secondary diseases and complex consequences such as falls and fractures, as well as higher mortality and frailty rates. There is a great need for prevention and treatment strategies. METHODS: In this analysis, we used magnetic resonance imaging (MRI) data from the randomised controlled FrOST trial, which enrolled community-dwelling osteosarcopenic men aged > 72 years randomly allocated to 16 months of twice-weekly high-intensity resistance training (HIRT) or a non-training control group. MR Dixon imaging was used to quantify the effects of HIRT on muscle fat infiltration in the paraspinal muscles, determined as changes in muscle tissue, fat faction and intermuscular adipose tissue (IMAT) in the erector spinae and psoas major muscles. Intention-to-treat analysis with multiple imputation was used to analyse the data set. RESULTS: After 16 months of intervention, 15 men from the HIRT and 16 men from the CG were included in the MRI analysis. In summary, no positive effects on the fat infiltration of the erector spinae and psoas major muscles were observed. CONCLUSIONS: The previously reported positive effects on lumbar spine bone mineral density (BMD) suggest that mechanotransduction induces tropic effects on bone, but that fat infiltration of the erector spinae and psoas major muscles are either irreversible or, for some unknown reason, resistant to exercise. Because of the beneficial effects on spinal BMD, HIRT is still recommended in osteosarcopenic older men, but further research is needed to confirm appropriate age-specific training exercises for the paraspinal muscles. The potential of different MRI sequences to quantify degenerative and metabolic changes in various muscle groups must be better characterized. TRIAL REGISTRATIONS: FrOST was approved by the University Ethics Committee of the Friedrich-Alexander University of Erlangen-Nürnberg (number 67_15b and 4464b) and the Federal Office for Radiation Projection (BfS, number Z 5-2,246,212 - 2017-002). Furthermore, it fully complies with the Declaration of Helsinki and is registered at ClinicalTrials.gov: NCT03453463 (05/03/2018). JAMA 310:2191-2194, 2013.


Assuntos
Mecanotransdução Celular , Músculos Paraespinais , Idoso , Masculino , Humanos , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/fisiologia , Densidade Óssea , Tecido Adiposo/diagnóstico por imagem , Projetos de Pesquisa , Imageamento por Ressonância Magnética/métodos
2.
Bone Rep ; 20: 101732, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38226335

RESUMO

Purpose: Predictors of 'imminent' risk of second hip fracture are unknown. The aims of the study were to explore strength of hip areal bone mineral density (aBMD), and muscle area and density for predicting second hip fracture at different time intervals. Methods: Data of the Chinese Second Hip Fracture Evaluation were analyzed, a longitudinal study to evaluate the risk of second hip fracture (of the contralateral hip) by using CT images obtained immediately after first hip fracture. Muscle cross-sectional area and density were measured of the gluteus maximus (G.MaxM) and gluteus medius and minimus (G.Med/MinM) and aBMD of the proximal femur at the contralateral unfractured side. Patients were followed up for a median time of 4.5 years. Separate Cox models were used to predict second hip fracture risk at different time intervals after first event adjusted for age, sex, BMI and diabetes. Results: The mean age of subjects with imminent (within 1st or 2nd year) second hip fracture was 79.80 ± 5.16 and 81.56 ± 3.64 years. In the 1st year after the first hip fracture, femoral neck (FN) aBMD predicted second hip fracture (HR 5.88; 95 % CI, 1.32-26.09). In the remaining years of follow-up after 2nd year, muscle density predicted second hip fracture (G.MaxM HR 2.13; 95 % CI, 1.25-3.65,G.Med/MinM HR 2.10; 95 % CI, 1.32-3.34). Conclusions: Our results show that femoral neck aBMD is an important predictor for second hip fracture within the first year and therefore suggest supports the importance concept of early and rapid-acting bone-active drugs to increase hip BMD. In addition, the importance of muscle density predicting second hip fracture after the second year suggest post hip fracture rehabilitation and exercise programs could also be important to reduce muscle fatty infiltration.

3.
J Bone Miner Res ; 38(11): 1689-1699, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37732678

RESUMO

Opportunistic screening is a new promising technique to identify individuals at high risk for osteoporotic fracture using computed tomography (CT) scans originally acquired for an clinical purpose unrelated to osteoporosis. In these CT scans, a calibration phantom traditionally required to convert measured CT values to bone mineral density (BMD) is missing. As an alternative, phantomless calibration has been developed. This study aimed to review the principles of four existing phantomless calibration methods and to compare their performance against the gold standard of simultaneous calibration (ΔBMD). All methods were applied to a dataset of 350 females scanned with a highly standardized CT protocol (DS1) and to a second dataset of 114 patients (38 female) from clinical routine covering a large range of CT acquisition and reconstruction parameters (DS2). Three of the phantomless calibration methods must be precalibrated with a reference dataset containing a calibration phantom. Sixty scans from DS1 and 57 from DS2 were randomly selected for this precalibration. For each phantomless calibration method first the best combination of internal reference materials (IMs) was selected. These were either air and blood or subcutaneous adipose tissue, blood, and cortical bone. In addition, for phantomless calibration a fifth method based on average calibration parameters derived from the reference dataset was applied. For DS1, ΔBMD results (mean ± standard deviation) for the phantomless calibration methods requiring a precalibration ranged from 0.1 ± 2.7 mg/cm3 to 2.4 ± 3.5 mg/cm3 with similar means but significantly higher standard deviations for DS2. Performance of the phantomless calibration method, which does not require a precalibration was worse (ΔBMD DS1: 12.6 ± 13.2 mg/cm3 , DS2: 0.5 ± 8.8 mg/cm3 ). In conclusion, phantomless BMD calibration performs well if precalibrated with a reference dataset. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Assuntos
Densidade Óssea , Osteoporose , Humanos , Feminino , Calibragem , Tomografia Computadorizada por Raios X/métodos , Osteoporose/diagnóstico por imagem , Minerais , Absorciometria de Fóton
4.
J Orthop Translat ; 42: 57-72, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37654433

RESUMO

Background: Magnetic resonance imaging (MRI) is the dominant 3D imaging modality to quantify muscle properties in skeletal muscle disorders, in inherited and acquired muscle diseases, and in sarcopenia, in cachexia and frailty. Methods: This review covers T1 weighted and Dixon sequences, introduces T2 mapping, diffusion tensor imaging (DTI) and non-proton MRI. Technical concepts, strengths, limitations and translational aspects of these techniques are discussed in detail. Examples of clinical applications are outlined. For comparison 31P-and 13C-MR Spectroscopy are also addressed. Results: MRI technology provides a rich toolset to assess muscle deterioration. In addition to classical measures such as muscle atrophy using T1 weighted imaging and fat infiltration using Dixon sequences, parameters characterizing inflammation from T2 maps, tissue sodium using non-proton MRI techniques or concentration or fiber architecture using diffusion tensor imaging may be useful for an even earlier diagnosis of the impairment of muscle quality. Conclusion: Quantitative MRI provides new options for muscle research and clinical applications. Current limitations that also impair its more widespread use in clinical trials are lack of standardization, ambiguity of image segmentation and analysis approaches, a multitude of outcome parameters without a clear strategy which ones to use and the lack of normal data.

5.
J Cachexia Sarcopenia Muscle ; 14(4): 1824-1835, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37208980

RESUMO

BACKGROUND: Mortality following hip fracture is high and incompletely understood. We hypothesize that hip musculature size and quality are related to mortality following hip fracture. This study aims to investigate the associations of hip muscle area and density from hip CT with death following hip fracture as well as assess the dependence of this association on time after hip fracture. METHODS: In this secondary analysis of the prospectively collected CT images and data from the Chinese Second Hip Fracture Evaluation, 459 patients were enrolled between May 2015 and June 2016 and followed up for a median of 4.5 years. Muscle cross-sectional area and density were measured of the gluteus maximus (G.MaxM) and gluteus medius and minimus (G.Med/MinM) and aBMD of the proximal femur. The Goutallier classification (GC) was used for qualitatively assessing muscle fat infiltration. Separate Cox models were used to predict mortality risk adjusted for covariates. RESULTS: At the end of the follow-up, 85 patients were lost, 81 patients (64% women) had died, and 293 (71% women) survived. The mean age of non-surviving patients at death (82.0 ± 8.1 years) was higher than that of the surviving patients (74.4 ± 9.9 years). The Parker Mobility Score and the American Society of Anesthesiologists scores of the patients that died were respectively lower and higher compared to the surviving patients. Hip fracture patients received different surgical procedures, and no significant difference in the percentage of hip arthroplasty was observed between the dead and the surviving patients (P = 0.11). The cumulative survival was significantly lower for patients with low G.MaxM area and density and low G.Med/MinM density, independent of age and clinical risk scores. The GC grades were not associated with the mortality after hip fracture. Muscle density of both G.MaxM (adj. HR 1.83; 95% CI, 1.06-3.17) and G.Med/MinM (adj. HR 1.98; 95% CI, 1.14-3.46) was associated with mortality in the 1st year after hip fracture. G.MaxM area (adj. HR 2.11; 95% CI, 1.08-4.14) was associated with mortality in the 2nd and later years after hip fracture. CONCLUSION: Our results for the first time show that hip muscle size and density are associated with mortality in older hip fracture patients, independent of age and clinical risk scores. This is an important finding to better understand the factors contributing to the high mortality in older hip fracture patients and to develop better future risk prediction scores that include muscle parameters.


Assuntos
Fraturas do Quadril , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Prospectivos , Fêmur , Fatores de Risco , Músculo Esquelético
6.
Bone ; 168: 116673, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36623756

RESUMO

OBJECTIVE: Osteoarthritis (OA) is a highly prevalent chronic condition. The subchondral bone plays an important role in onset and progression of OA making it a potential treatment target for disease-modifying therapeutic approaches. However, little is known about changes of periarticular bone mineral density (BMD) in OA and its relation to meniscal coverage and meniscal extrusion at the knee. Thus, the aim of this study was to describe periarticular BMD in the Applied Public-Private Research enabling OsteoArthritis Clinical Headway (APPROACH) cohort at the knee and to analyze the association with structural disease severity, meniscal coverage and meniscal extrusion. DESIGN: Quantitative CT (QCT), MRI and radiographic examinations were acquired in 275 patients with knee osteoarthritis (OA). QCT was used to assess BMD at the femur and tibia, at the cortical bone plate (Cort) and at the epiphysis at three locations: subchondral (Sub), mid-epiphysis (Mid) and adjacent to the physis (Juxta). BMD was evaluated for the medial and lateral compartment separately and for subregions covered and not covered by the meniscus. Radiographs were used to determine the femorotibial angle and were evaluated according to the Kellgren and Lawrence (KL) system. Meniscal extrusion was assessed from 0 to 3. RESULTS: Mean BMD differed significantly between each anatomic location at both the femur and tibia (p < 0.001) in patients with KL0. Tibial regions assumed to be covered with meniscus in patients with KL0 showed lower BMD at Sub (p < 0.001), equivalent BMD at Mid (p = 0.07) and higher BMD at Juxta (p < 0.001) subregions compared to regions not covered with meniscus. Knees with KL2-4 showed lower Sub (p = 0.03), Mid (p = 0.01) and Juxta (p < 0.05) BMD at the medial femur compared to KL0/1. Meniscal extrusion grade 2 and 3 was associated with greater BMD at the tibial Cort (p < 0.001, p = 0.007). Varus malalignment is associated with significant greater BMD at the medial femur and at the medial tibia at all anatomic locations. CONCLUSION: BMD within the epiphyses of the tibia and femur decreases with increasing distance from the articular surface. Knees with structural OA (KL2-4) exhibit greater cortical BMD values at the tibia and lower BMD at the femur at the subchondral level and levels beneath compared to KL0/1. BMD at the tibial cortical bone plate is greater in patients with meniscal extrusion grade 2/3.


Assuntos
Menisco , Osteoartrite do Joelho , Humanos , Densidade Óssea , Tíbia/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Gravidade do Paciente
7.
Clin Interv Aging ; 18: 71-80, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36700164

RESUMO

Purpose: To evaluate the effect of a high-intensity resistance training (HIT-RT) on visceral adipose tissue (VAT) and abdominal aortic calcifications (AAC). Patients and Methods: We conducted a post hoc analysis of the Franconian Osteopenia and Sarcopenia Trial (FrOST). 43 community-dwelling men with osteosarcopenia aged 72 years and older were randomly allocated to a supervised high-intensity resistance training (HIT-RT) twice weekly for 18 months (EG; n=21) and a non-training control group (CG; n=22). Non-contrast enhanced 2-point Dixon MRI scans covering mid L2 to mid L3 were acquired to measure VAT volume inside the abdominal cavity. Volume of AAC and hard plaques in renal arteries, truncus celiacus and superior mesenteric artery was measured by computed tomography (CT) scans covering mid T12 to mid L3. Intention-to-treat analysis with imputation for missing data was used to determine longitudinal changes in VAT and AAC volume. Correlations were used to determine associations between VAT and AAC. Results: Significant reduction of VAT volume in the EG (-7.7%; p<0.001) combined with no change in the CG (-1.3%; p=0.46) resulted in a significant 6.4% between group effect (p=0.022). We observed a significant increase of AAC volume in EG (+10.3%; p<0.001) and CG (12.0%; p<0.001). AAC differences between groups were not significant (p=0.57). In vascular outlets increases in volume of the hard plaques were observed in both groups, however, not all of them were significant. There was no significant correlation between changes in VAT and AAC volumes. Conclusion: The study confirmed a positive impact of HIT-RT on the metabolic and cardiovascular risk profile with respect to reduction of VAT volume. No positive exercise effect on AAC was observed. However, there was a further progression of AAC volume independent of group affiliation. Whether different exercise regimen may show a positive effect on AAC remains subject to further studies.


Assuntos
Doenças Ósseas Metabólicas , Treinamento Resistido , Sarcopenia , Masculino , Humanos , Idoso , Gordura Intra-Abdominal/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Sarcopenia/terapia , Tomografia Computadorizada por Raios X/métodos
8.
Curr Osteoporos Rep ; 21(1): 65-76, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36435912

RESUMO

PURPOSE OF REVIEW: Opportunistic screening is a combination of techniques to identify subjects of high risk for osteoporotic fracture using routine clinical CT scans prescribed for diagnoses unrelated to osteoporosis. The two main components are automated detection of vertebral fractures and measurement of bone mineral density (BMD) in CT scans, in which a phantom for calibration of CT to BMD values is not used. This review describes the particular challenges of opportunistic screening and provides an overview and comparison of current techniques used for opportunistic screening. The review further outlines the performance of opportunistic screening. RECENT FINDINGS: A wide range of technologies for the automatic detection of vertebral fractures have been developed and successfully validated. Most of them are based on artificial intelligence algorithms. The automated differentiation of osteoporotic from traumatic fractures and vertebral deformities unrelated to osteoporosis, the grading of vertebral fracture severity, and the detection of mild vertebral fractures is still problematic. The accuracy of automated fracture detection compared to classical radiological semi-quantitative Genant scoring is about 80%. Accuracy errors of alternative BMD calibration methods compared to simultaneous phantom-based calibration used in standard quantitative CT (QCT) range from below 5% to about 10%. The impact of contrast agents, frequently administered in clinical CT on the determination of BMD and on fracture risk determination is still controversial. Opportunistic screening, the identification of vertebral fracture and the measurement of BMD using clinical routine CT scans, is feasible but corresponding techniques still need to be integrated into the clinical workflow and further validated with respect to the prediction of fracture risk.


Assuntos
Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Inteligência Artificial , Osteoporose/diagnóstico por imagem , Densidade Óssea , Tomografia Computadorizada por Raios X , Absorciometria de Fóton/métodos
9.
Invest Radiol ; 58(4): 265-272, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36374200

RESUMO

OBJECTIVES: The aims were to investigate if potassium ( 39 K) magnetic resonance imaging (MRI) can be used to analyze changes in the apparent tissue potassium concentration (aTPC) in calf muscle tissue after eccentric exercise and in delayed-onset muscle soreness, and to compare these to corresponding changes in the apparent tissue sodium concentration (aTSC) measured with sodium ( 23 Na) MRI. MATERIALS AND METHODS: Fourteen healthy subjects (7 female, 7 male; 25.0 ± 2.8 years) underwent 39 K and 23 Na MRI at a 7 T MR system, as well as 1 H MRI at a 3 T MR system. Magnetic resonance imaging data and blood samples were collected at baseline (t0), directly after performing eccentric exercise (t1) and 48 hours after exercise (t2). Self-reported muscle soreness was evaluated using a 10-cm visual analog scale for pain (0, no pain; 10, worst pain) at t0, t1, and t2. Quantification of aTPC/aTSC was performed after correcting the measured 39 K/ 23 Na signal intensities for partial volume and relaxation effects using 5 external reference phantoms. Edema volume and 1 H T 2 relaxation times were determined based on the 1 H MRI data. Participants were divided according to their increase in creatine kinase (CK) level into high (CK t2 ≥ 10·CK t0 ) and low CK (CK t2 < 10·CK t0 ) subjects. RESULTS: Blood serum CK and edema volume were significantly increased 48 hours after exercise compared with baseline ( P < 0.001). Six participants showed a high increase in blood serum CK level at t2 relative to baseline, whereas 8 participants had only a low to moderate increase in blood serum CK. All participants reported increased muscle soreness both at rest and when climbing stairs at t1 (0.4 ± 0.7; 1.4 ± 1.2) and t2 (1.6 ± 1.4; 4.8 ± 1.9) compared with baseline (0 ± 0; 0 ± 0). Moreover, aTSC was increased at t1 in exercised muscles of all participants (increase by 57% ± 24% in high CK, 73% ± 33% in low CK subjects). Forty-eight hours after training, subjects with high increase in blood serum CK still showed highly increased aTSC (increase by 79% ± 57% compared with t0). In contrast, aTPC at t2 was elevated in exercised muscles of low CK subjects (increase by 19% ± 11% compared with t0), in which aTSC had returned to baseline or below. Overall, aTSC and aTPC showed inverse evolution, with changes in aTSC being approximately twice as high as in aTPC. CONCLUSIONS: Our results showed that 39 K MRI is able to detect changes in muscular potassium concentrations caused by eccentric exercise. In combination with 23 Na MRI, this enables a more holistic analysis of tissue ion concentration changes.


Assuntos
Creatina Quinase , Mialgia , Humanos , Masculino , Feminino , Mialgia/diagnóstico por imagem , Mialgia/patologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Imageamento por Ressonância Magnética , Edema/patologia
10.
NMR Biomed ; 36(1): e4819, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994248

RESUMO

Noninvasively assessing tissue potassium concentrations (TPCs) using potassium magnetic resonance imaging (39 K MRI) could give valuable information on physiological processes connected to various pathologies. However, because of inherently low 39 K MR image resolution and strong signal blurring, a reliable measurement of the TPC is challenging. The aim of this work was to investigate the feasibility of a muscle-specific TPC determination with a focus on the influence of a varying residual quadrupolar interaction in human lower leg muscles. The quantification accuracy of a muscle-specific TPC determination was first assessed using simulated 39 K MRI data. In vivo 39 K and corresponding sodium (23 Na) MRI data of healthy lower leg muscles (n = 14, seven females) were acquired on a 7-T MR system using a double-resonant 23 Na/39 K birdcage Tx/Rx RF coil. Additional 1 H MR images were acquired on a 3-T MR system and used for tissue segmentation. Quantification of TPC was performed after a region-based partial volume correction (PVC) using five external reference phantoms. Simulations not only underlined the importance of PVC for correctly assessing muscle-specific TPC values, but also revealed the strong impact of a varying residual quadrupolar interaction between different muscle regions on the measured TPC. Using 39 K T2 * decay curves, we found significantly higher residual quadrupolar interaction in tibialis anterior muscle (TA; ωq = 194 ± 28 Hz) compared with gastrocnemius muscle (medial/lateral head, GM/GL; ωq = 151 ± 25 Hz) and soleus muscle (SOL; ωq = 102 ± 32 Hz). If considered in the PVC, TPC in individual muscles was similar (TPC = 98 ± 11/96 ± 14/99 ± 8/100 ± 12 mM in GM/GL/SOL/TA). Comparison with tissue sodium concentrations suggested that residual quadrupolar interactions might also influence the 23 Na MRI signal of lower leg muscles. A TPC determination of individual lower leg muscles is feasible and can therefore be applied in future studies. Considering a varying residual quadrupolar interaction for PVC of 39 K MRI data is essential to reliably assess potassium concentrations in individual muscles.


Assuntos
Músculos , Potássio , Humanos , Sódio , Imageamento por Ressonância Magnética
11.
Bone ; 165: 116571, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36174928

RESUMO

Identification of bone erosions and quantification of erosion volume is important for rheumatoid arthritis diagnosis, and can add important information to evaluate disease progression and treatment effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) is well suited for this purpose, however analysis methods are not widely available. The purpose of this study was to develop an open-source software tool for the identification and quantification of bone erosions using images acquired by HR-pQCT. The collection of modules, Bone Analysis Modules (BAM) - Erosion, implements previously published erosion analysis techniques as modules in 3D Slicer, an open-source image processing and visualization tool. BAM includes a module to automatically identify cortical interruptions, from which erosions are manually selected, and a hybrid module that combines morphological and level set operations to quantify the volume of bone erosions. HR-pQCT images of the second and third metacarpophalangeal (MCP) joints were acquired in patients with RA (XtremeCT, n = 14, XtremeCTII, n = 22). The number of cortical interruptions detected by BAM-Erosion agreed strongly with the previously published cortical interruption detection algorithm for both XtremeCT (r2 = 0.85) and XtremeCTII (r2 = 0.87). Erosion volume assessment by BAM-Erosion agreed strongly (r2 = 0.95) with the Medical Image Analysis Framework. BAM-Erosion provides an open-source erosion analysis tool that produces comparable results to previously published algorithms, with improved options for visualization. The strength of the tool is that it implements multiple image processing algorithms for erosion analysis on a single, widely available, open-source platform that can accommodate future updates.


Assuntos
Artrite Reumatoide , Humanos , Artrite Reumatoide/diagnóstico por imagem , Articulação Metacarpofalângica , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador , Progressão da Doença
12.
Quant Imaging Med Surg ; 12(6): 3340-3350, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35655834

RESUMO

Background: Radiographic absorptiometry (RA) is one of the earliest methods of bone densitometry and has been used to measure the phalanges and metacarpals where soft tissue attenuation is minimal. The aim of this study was to determine whether the technique can be adapted to correct for soft tissue attenuation and measure areal bone mineral density (aBMD) in the forearm. Methods: A total of 51 patients referred for a clinical spine and hip dual-energy X-ray absorptiometry (DXA) examination and 8 young and middle-aged volunteers were recruited to this study. The first 29 participants (20 women, 9 men, aged 61±14 years) served as the training cohort, and the remaining 30 (20 women, 10 men, aged 55±16 years) comprised the validation cohort. All participants underwent a DXA scan of their non-dominant forearm, and a digital X-ray image of the same arm was acquired with a step phantom. Identical regions of interest (ROIs) in the radius and ulna at the one-third radius site were measured on the X-ray and DXA images, and a soft tissue ROI was measured on X-ray images between the radius and ulna. The X-ray measurements in the training cohort were expressed as equivalent step phantom thickness (Eq. SPT) and used to estimate forearm aBMD using a linear equation calibrated against the DXA scans. Estimates of forearm aBMD made from the digital X-ray images acquired in the validation cohort were compared with the results of the DXA scans. Results: Digital X-ray estimates of radius and ulna aBMD at the one-third radius site in the validation cohort showed a good correlation with GE-Lunar iDXA scanner measurements (r=0.795; P<0.001). The Bland-Altman plot had a mean bias of -0.002 g/cm2 and 95% limits of agreement of -0.185 to +0.181 g/cm2. Conclusions: Digital X-ray estimates of proximal forearm aBMD corrected for soft tissue attenuation correlated with DXA measurements with correlation coefficients comparable to those seen for other peripheral bone densitometry technologies.

13.
Aging Clin Exp Res ; 34(9): 2089-2098, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35633478

RESUMO

BACKGROUND: Myosteatosis, skeletal muscle fat infiltration, is associated with inflammation and fibrosis. The age-related increase of myosteatosis is an important characteristic of sarcopenia and contributes to fragility. AIMS: To investigate the impact of healthy aging on intermuscular adipose tissue (IMAT) and muscle fat fraction (FF) in the thigh and the paraspinal muscles in males. METHODS: In 54 healthy males (age 20-70), all active hobby golfers, magnetic resonance imaging was performed to determine volume of IMAT, volume of muscle tissue (MT) and of percentage of FF. RESULTS: Between ages 20-70, at the thigh, IMAT/MT volume and MT FF increased annually by 2.9% and 1.3%, respectively. At the psoas IMAT/Psoas volume did not change with age. MT FF increased by 1.5% annually. At the erector spinae IMAT/Erector volume decreased by 0.3% and MT FF increased by 2.8% annually. DISCUSSION: With increasing age, in males, thigh muscle atrophied, muscle tissue was partly replaced by adipose tissue and remaining muscle tissue also contained more fat. Similar effects were observed in the erector spinae. The psoas muscle did not atrophy, although MT FF also increased with age. Overall correlations with age were weak to moderate with higher correlations observed in the paraspinal muscles. CONCLUSIONS: Age-related increases of muscle fat infiltration were observed in the thigh and in the spine. Muscle atrophy did not occur in the psoas. In cross-sectional studies, an adjustment of volumetric parameters by muscle volume is advisable when comparing age-dependent results.


Assuntos
Músculos Paraespinais , Coxa da Perna , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Idoso , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Atrofia Muscular , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/patologia , Coxa da Perna/patologia
14.
Z Med Phys ; 32(4): 403-416, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35597742

RESUMO

Photon-counting (PC) detectors for clinical computed tomography (CT) may offer improved imaging capabilities compared to conventional energy-integrating (EI) detectors, e.g. superior spatial resolution and detective efficiency. We here investigate if PCCT can reduce the administered dose in examinations aimed at quantifying trabecular bone microstructure. Five human vertebral bodies were scanned three times in an abdomen phantom (QRM, Germany) using an experimental dual-source CT (Somatom CounT, Siemens Healthineers, Germany) housing an EI detector (0.60 mm pixel size at the iso-center) and a PC detector (0.25 mm pixel size). A tube voltage of 120 kV was used. Tube current-time product for EICT was 355 mAs (23.8 mGy CTDI32 cm). Dose-matched UHR-PCCT (UHRdm, 23.8 mGy) and noise-matched acquisitions (UHRnm, 10.5 mGy) were performed and reconstructed to a voxel size of 0.156 mm using a sharp kernel. Measurements of bone mineral density (BMD) and trabecular separation (Tb.Sp) and Tb.Sp percentiles reflecting the different scales of the trabecular interspacing were performed and compared to a gold-standard measurement using a peripheral CT device (XtremeCT, SCANCO Medical, Switzerland) with an isotropic voxel size of 0.082 mm and 6.6 mGy CTDI10 cm. The image noise was quantified and the relative error with respect to the gold-standard along with the agreement between CT protocols using Lin's concordance correlation coefficient (rCCC) were calculated. The Mean ±â€¯StdDev of the measured image noise levels in EICT was 109.6 ±â€¯3.9 HU. UHRdm acquisitions (same dose as EICT) showed a significantly lower noise level of 78.6 ±â€¯4.6 HU (p = 0.0122). UHRnm (44% dose of EICT) showed a noise level of 115.8 ±â€¯3.7 HU, very similar to EICT at the same spatial resolution. For BMD the overall Mean ±â€¯StdDev for EI, UHRdm and UHRnm were 114.8 ±â€¯28.6 mgHA/cm3, 121.6 ±â€¯28.8 mgHA/cm3 and 121.5 ±â€¯28.6 mgHA/cm3, respectively, compared to 123.1 ±â€¯25.5 mgHA/cm3 for XtremeCT. For Tb.Sp these values were 1.86 ±â€¯0.54 mm, 1.80 ±â€¯0.56 mm and 1.84 ±â€¯0.52 mm, respectively, compared to 1.66 ±â€¯0.48 mm for XtremeCT. The ranking of the vertebrae with regard to Tb.Sp data was maintained throughout all Tb.Sp percentiles and among the CT protocols and the gold-standard. The agreement between protocols was very good for all comparisons: UHRnm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.998), UHRnm vs. UHRdm (BMD rCCC = 0.998; Tb.Sp rCCC = 0.993) and UHRdm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.991). Consequently, the relative RMS-errors from linear regressions against the gold-standard for EICT, UHRdm and UHRnm were very similar for BMD (7.1%, 5.2% and 5.4%) and for Tb.Sp (3.3%, 3.3% and 2.9%), with a much lower radiation dose for UHRnm. Short-term reproducibility for BMD measurements was similar and below 0.2% for all protocols, but for Tb.Sp showed better results for UHR (about 1/3 of the level for EICT). In conclusion, CT with UHR-PC detectors demonstrated lower image noise and better reproducibility for assessments of bone microstructure at similar dose levels. For UHRnm, radiation exposure levels could be reduced by 56% without deterioration of performance levels in the assessment of bone mineral density and bone microstructure.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Abdome
15.
J Cachexia Sarcopenia Muscle ; 13(3): 1927-1937, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35429146

RESUMO

BACKGROUND: Patients with a first hip fracture are at high risk of fracturing their other hip. Despite this, preventive therapy is often not given. Because little is known about specific risk factors of a second hip fracture, we investigated the association with areal bone mineral density (aBMD), muscle size, and density. We also investigated whether muscle parameters predict the risk of a contralateral fracture independently of aBMD. METHODS: Three groups were included, one without hip fracture (a subcohort of the China Action on Spine and Hip Status study), one with a first, and one with a second hip fracture. Subjects with fractures were recruited from the longitudinal Chinese Second Hip Fracture Evaluation (CSHFE). Computed tomography scans of CSHFE patients, which were obtained immediately following their first fracture, were used to measure cross-sectional area and density of the gluteus maximus (G.MaxM) and gluteus medius and minimus (G.Med/MinM) muscles. Computed tomography X-ray absorptiometry was used to measure aBMD of the contralateral femur. Median follow-up time to second fracture was 4.5 years. Cox proportional hazards models were used to compute hazard ratios (HR) of second hip fracture risk in subjects with a first hip fracture. Multivariate logistic regressions were used to compare odds ratios (OR) for the risk of a first and second hip fracture. RESULTS: Three hundred and one participants (68.4 ± 6.1 years, 64% female) without and 302 participants (74.6 ± 9.9 years, 71% female) with a first hip fracture were included in the analysis. Among the latter, 45 (79.2 ± 7.1 years) sustained a second hip fracture. ORs for first hip fracture were significant for aBMD and muscle size and density. ORs for a second fracture were smaller by a factor of 3 to 4 and no longer significant for femoral neck (FN) aBMD. HRs for predicting second hip fracture confirmed the results. G.Med/MinM density (HR, 1.68; CI, 1.20-2.35) and intertrochanter aBMD (HR, 1.62; CI, 1.13-2.31) were the most significant. FN aBMD was not significant. G.Med/MinM density remained significant for predicting second hip fracture after adjustment for FN (HR, 1.66; Cl, 1.18-2.30) or total hip aBMD (HR, 1.50; 95% Cl, 1.04-2.15). CONCLUSIONS: Density of the G.Med/MinM muscle is an aBMD independent predictor of the risk of second hip fracture. Intertrochanteric aBMD is a better predictor of second hip fracture than FN and total hip aBMD. These results may trigger a paradigm shift in the assessment of second hip fracture risk and prevention strategies.


Assuntos
Colo do Fêmur , Fraturas do Quadril , Feminino , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/etiologia , Humanos , Masculino , Músculos , Estudos Prospectivos , Fatores de Risco
16.
Front Endocrinol (Lausanne) ; 13: 799381, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35282435

RESUMO

Background and Purpose: Although it is widely recognized that hip BMD is reduced in patients with hip fracture, the differences in geometrical parameters such as cortical volume and thickness between subjects with and without hip fracture are less well known. Materials and Methods: Five hundred and sixty two community-dwelling elderly women with hip CT scans were included in this cross-sectional study, of whom 236 had an acute hip fracture. 326 age matched women without hip fracture served as controls. MIAF-Femur software was used for the measurement of the intact contralateral femur in patients with hip fracture and the left femur of the controls. Integral and cortical volumes (Vols) of the total hip (TH), femoral head (FH), femoral neck (FN), trochanter (TR) and intertrochanter (IT) were analyzed. In the FH and FN the volumes were further subdivided into superior anterior (SA) and posterior (SP) as well as inferior anterior (IA) and posterior (IP) quadrants. Cortical thickness (CortThick) was determined for all sub volumes of interest (VOIs) listed above. Results: The average age of the control and fracture groups was 71.7 and 72.0 years, respectively. The fracture patients had significantly lower CortThick and Vol of all VOIs except for TRVol. In the fracture patients, cortical thickness and volume at the FN were significantly lower in all quadrants except for cortical volume of quadrant SA (p= 0.635). Hip fracture patients had smaller integral FN volume and cross-sectional area (CSA) before and after adjustment of age, height and weight. With respect to hip fracture discrimination, cortical volume performed poorer than cortical thickness across the whole proximal femur. The ratio of Cort/TrabMass (RCTM), a measure of the internal distribution of bone, performed better than cortical thickness in discriminating hip fracture risk. The highest area under curve (AUC) value of 0.805 was obtained for the model that included THCortThick, FHVol, THRCTM and FNCSA. Conclusion: There were substantial differences in total and cortical volume as well as cortical thickness between fractured and unfractured women across the proximal femur. A combination of geometric variables resulted in similar discrimination power for hip fracture risk as aBMD.


Assuntos
Densidade Óssea , Fraturas do Quadril , Idoso , Estudos de Casos e Controles , Estudos Transversais , Feminino , Colo do Fêmur , Fraturas do Quadril/diagnóstico por imagem , Humanos
17.
J Bone Miner Res ; 37(6): 1136-1146, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35340062

RESUMO

In a randomized clinical trial in patients initiating glucocorticoid therapy (GC-I) or on long-term therapy (GC-C), denosumab every 6 months increased spine and hip bone mineral density at 12 and 24 months significantly more than daily risedronate. The aim of this study was to evaluate the effects of denosumab compared with risedronate on bone strength and microarchitecture measured by high-resolution peripheral quantitative computed tomography (HR-pQCT) in GC-I and GC-C. A subset of 110 patients had high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of the distal radius and tibia at baseline and at 12 and 24 months. Cortical and trabecular microarchitecture were assessed with standard analyses and failure load (FL) with micro-finite element analysis. At the radius at 24 months, FL remained unchanged with denosumab and significantly decreased with risedronate in GC-I (-4.1%, 95% confidence interval [CI] -6.4, -1.8) and, in GC-C, it significantly increased with denosumab (4.3%, 95% CI 2.1, 6.4) and remained unchanged with risedronate. Consequently, FL was significantly higher with denosumab than with risedronate in GC-I (5.6%, 95% CI 2.4, 8.7, p < 0.001) and in GC-C (4.1%, 95% CI 1.1, 7.2, p = 0.011). We also found significant differences between denosumab and risedronate in percentage changes in cortical and trabecular microarchitectural parameters in GC-I and GC-C. Similar results were found at the tibia. To conclude, this HR-pQCT study shows that denosumab is superior to risedronate in terms of preventing FL loss at the distal radius and tibia in GC-I and in increasing FL at the radius in GC-C, based on significant differences in changes in the cortical and trabecular bone compartments between treatment groups in GC-I and GC-C. These results suggest that denosumab could be a useful therapeutic option in patients initiating GC therapy or on long-term GC therapy and may contribute to treatment decisions in this patient population. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Assuntos
Denosumab , Glucocorticoides , Densidade Óssea , Osso e Ossos , Denosumab/farmacologia , Denosumab/uso terapêutico , Glucocorticoides/efeitos adversos , Humanos , Rádio (Anatomia) , Ácido Risedrônico/farmacologia , Tíbia/diagnóstico por imagem
19.
Bone ; 157: 116304, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34973497

RESUMO

Opportunistic screening using existing CT images may be a new strategy to identify subjects at increased risk for osteoporotic fracture. Low bone mineral density (BMD) is a key parameter but routine clinical CT scans do not include a calibration phantom to calculate BMD from the measured CT values. An alternative is internal or phantomless calibration, which is based on the CT values of air and of internal tissues of the subject such as blood, muscle or adipose tissue. However, the composition and as a consequence the CT values of these so-called internal calibration materials vary among subjects, which introduces additional BMD accuracy errors compared to phantom based calibration. The objective of this study was to quantify these accuracy errors and to identify optimum combinations of internal calibration materials (IM) for BMD assessments in opportunistic screening. Based on the base material decomposition theory we demonstrate how BMD can be derived from the CT values of the internal calibration materials. 121 CT datasets of the lumbar spine form postmenopausal women were used to determine the population variance of blood assessed in the aorta or the inferior vena cava, skeletal muscle of the erector spinae or psoas, subcutaneous adipose tissue (SAT) and air. The corresponding standard deviations were used for error propagation to determine phantomless calibration related BMD accuracy errors. Using a CT value of 150 HU, a typical value of trabecular bone, simulated BMD accuracy errors for most IM combinations containing air as one of the two base materials were below 5% or 6 mg/cm3. The lowest errors were determined for the combination of blood and air (<2 mg/cm3). The combination of blood and skeletal muscle resulted in higher errors (>10.5% or >12 mg/cm3) and is not recommended. Due to possible age-related differences in tissue composition, the selection of IMs is suggested to be adapted according to the measured subject. In younger subjects without significant aortic calcifications, air and blood of the aorta may be the best combination whereas in elderly subjects, air and SAT (error of 4%) may be preferable. The use of skeletal muscle as one of the two IMs is discouraged, in particular in elderly subjects because of varying fatty infiltration. A practical implementation of the internal calibration with different IM pairs confirmed the theoretical results. In summary, compared to a phantom based calibration the phantomless approach used for opportunistic screening creates additional BMD accuracy errors of 2% or more, dependent on the used internal reference tissues. The impact on fracture prediction still must be evaluated.


Assuntos
Densidade Óssea , Fraturas por Osteoporose , Absorciometria de Fóton , Idoso , Calibragem , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
20.
Front Physiol ; 12: 700423, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34366890

RESUMO

Whole-body electromyostimulation (WB-EMS) is commercially advertised as a time-efficient resistance-type exercise technology. Indeed, the commercial, non-medical setting applies 20 min of WB-EMS only once a week. However, this setting conflicts with the approved scientific approach of higher training frequencies. Using data from an ongoing study on WB-EMS and golf performance as a vehicle, we evaluate the effect of once weekly WB-EMS on changes of fatty muscle infiltration, as a crucial parameter of muscle quality. Fifty-four moderately physically active male amateur golfers 18-70 years old were randomly allocated to a WB-EMS (n = 27) with a standard setting of once weekly 20 min and a non-WB-EMS control group (CG, n = 27). Intermuscular adipose tissue (IMAT) volume and intrafascial muscle tissue (MT) volume per unit of intrafascial volume as determined by magnetic resonance imaging were used to characterize muscle quality. Intention to treat analysis with multiple imputation was applied. WB-EMS was conducted at the participants' homes; thus, the attendance rate was close to 100%. After 16 weeks of intervention, we observed increases in volume-adjusted IMAT (p = 0.040) and decreases in MT (p = 0.206) in the CG. IMAT decreased in the WB-EMS group (p = 0.215), while MT increased significantly (p = 0.032). Of importance, group difference (i.e., "effects") for intra-group changes in volume-adjusted IMAT (effect size: d´ = 0.66; p = 0.028) and MT (d´ = 0.70; p = 0.020) was significant for both parameters. Once weekly WB-EMS application significantly affects muscle quality of the mid-thigh in moderately active, healthy men 18-70 years old.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...