Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Sci Rep ; 14(1): 8253, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589478

RESUMO

This work presents a deep learning approach for rapid and accurate muscle water T2 with subject-specific fat T2 calibration using multi-spin-echo acquisitions. This method addresses the computational limitations of conventional bi-component Extended Phase Graph fitting methods (nonlinear-least-squares and dictionary-based) by leveraging fully connected neural networks for fast processing with minimal computational resources. We validated the approach through in vivo experiments using two different MRI vendors. The results showed strong agreement of our deep learning approach with reference methods, summarized by Lin's concordance correlation coefficients ranging from 0.89 to 0.97. Further, the deep learning method achieved a significant computational time improvement, processing data 116 and 33 times faster than the nonlinear least squares and dictionary methods, respectively. In conclusion, the proposed approach demonstrated significant time and resource efficiency improvements over conventional methods while maintaining similar accuracy. This methodology makes the processing of water T2 data faster and easier for the user and will facilitate the utilization of the use of a quantitative water T2 map of muscle in clinical and research studies.


Assuntos
Algoritmos , Aprendizado Profundo , Água , Calibragem , Imageamento por Ressonância Magnética/métodos , Músculos/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Encéfalo
2.
Front Cardiovasc Med ; 11: 1359715, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596691

RESUMO

Background: A reduced left atrial (LA) strain correlates with the presence of atrial fibrillation (AF). Conventional atrial strain analysis uses two-dimensional (2D) imaging, which is, however, limited by atrial foreshortening and an underestimation of through-plane motion. Retrospective gated computed tomography (RGCT) produces high-fidelity three-dimensional (3D) images of the cardiac anatomy throughout the cardiac cycle that can be used for estimating 3D mechanics. Its feasibility for LA strain measurement, however, is understudied. Aim: The aim of this study is to develop and apply a novel workflow to estimate 3D LA motion and calculate the strain from RGCT imaging. The utility of global and regional strains to separate heart failure in patients with reduced ejection fraction (HFrEF) with and without AF is investigated. Methods: A cohort of 30 HFrEF patients with (n = 9) and without (n = 21) AF underwent RGCT prior to cardiac resynchronisation therapy. The temporal sparse free form deformation image registration method was optimised for LA feature tracking in RGCT images and used to estimate 3D LA endocardial motion. The area and fibre reservoir strains were calculated over the LA body. Universal atrial coordinates and a human atrial fibre atlas enabled the regional strain calculation and the fibre strain calculation along the local myofibre orientation, respectively. Results: It was found that global reservoir strains were significantly reduced in the HFrEF + AF group patients compared with the HFrEF-only group patients (area strain: 11.2 ± 4.8% vs. 25.3 ± 12.6%, P = 0.001; fibre strain: 4.5 ± 2.0% vs. 15.2 ± 8.8%, P = 0.001), with HFrEF + AF patients having a greater regional reservoir strain dyssynchrony. All regional reservoir strains were reduced in the HFrEF + AF patient group, in whom the inferior wall strains exhibited the most significant differences. The global reservoir fibre strain and LA volume + posterior wall reservoir fibre strain exceeded LA volume alone and 2D global longitudinal strain (GLS) for AF classification (area-under-the-curve: global reservoir fibre strain: 0.94 ± 0.02, LA volume + posterior wall reservoir fibre strain: 0.95 ± 0.02, LA volume: 0.89 ± 0.03, 2D GLS: 0.90 ± 0.03). Conclusion: RGCT enables 3D LA motion estimation and strain calculation that outperforms 2D strain metrics and LA enlargement for AF classification. Differences in regional LA strain could reflect regional myocardial properties such as atrial fibrosis burden.

3.
Magn Reson Med ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501914

RESUMO

PURPOSE: To evaluate the use of pre-excitation gradients for eddy current-nulled convex optimized diffusion encoding (Pre-ENCODE) to mitigate eddy current-induced image distortions in diffusion-weighted MRI (DWI). METHODS: DWI sequences using monopolar (MONO), ENCODE, and Pre-ENCODE were evaluated in terms of the minimum achievable echo time (TE min $$ {}_{\mathrm{min}} $$ ) and eddy current-induced image distortions using simulations, phantom experiments, and in vivo DWI in volunteers ( N = 6 $$ N=6 $$ ). RESULTS: Pre-ENCODE provided a shorter TE min $$ {}_{\mathrm{min}} $$ than MONO (71.0 ± $$ \pm $$ 17.7ms vs. 77.6 ± $$ \pm $$ 22.9ms) and ENCODE (71.0 ± $$ \pm $$ 17.7ms vs. 86.2 ± $$ \pm $$ 14.2ms) in 100 % $$ \% $$ of the simulated cases for a commercial 3T MRI system with b-values ranging from 500 to 3000 s/mm 2 $$ {}^2 $$ and in-plane spatial resolutions ranging from 1.0 to 3.0mm 2 $$ {}^2 $$ . Image distortion was estimated by intravoxel signal variance between diffusion encoding directions near the phantom edges and was significantly lower with Pre-ENCODE than with MONO (10.1 % $$ \% $$ vs. 22.7 % $$ \% $$ , p = 6 - 5 $$ p={6}^{-5} $$ ) and comparable to ENCODE (10.1 % $$ \% $$ vs. 10.4 % $$ \% $$ , p = 0 . 12 $$ p=0.12 $$ ). In vivo measurements of apparent diffusion coefficients were similar in global brain pixels (0.37 [0.28,1.45] × 1 0 - 3 $$ \times 1{0}^{-3} $$ mm 2 $$ {}^2 $$ /s vs. 0.38 [0.28,1.45] × 1 0 - 3 $$ \times 1{0}^{-3} $$ mm 2 $$ {}^2 $$ /s, p = 0 . 25 $$ p=0.25 $$ ) and increased in edge brain pixels (0.80 [0.17,1.49] × 1 0 - 3 $$ \times 1{0}^{-3} $$ mm 2 $$ {}^2 $$ /s vs. 0.70 [0.18,1.48] × 1 0 - 3 $$ \times 1{0}^{-3} $$ mm 2 $$ {}^2 $$ /s, p = 0 . 02 $$ p=0.02 $$ ) for MONO compared to Pre-ENCODE. CONCLUSION: Pre-ENCODE mitigated eddy current-induced image distortions for diffusion imaging with a shorter TE min $$ {}_{\mathrm{min}} $$ than MONO and ENCODE.

4.
Ann Biomed Eng ; 52(5): 1335-1346, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38341399

RESUMO

Blood pressure gradient ( Δ P ) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of Δ P estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N = 17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. Δ P across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. The 0D simulations were extremely efficient ( ∼ 15 s computation time) compared to 3D simulations ( ∼ 30 h computation time on a cluster). However, the 0D Δ P estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as Δ P ≥ 20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.


Assuntos
Coartação Aórtica , Humanos , Coartação Aórtica/diagnóstico por imagem , Pressão Sanguínea , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Simulação por Computador
5.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38219955

RESUMO

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.

6.
Int J Cardiovasc Imaging ; 40(1): 157-165, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37831292

RESUMO

PURPOSE: Poor acoustic windows make interval assessment of systolic function in patients with (Duchenne Muscular Dystrophy) DMD by echocardiography (echo) difficult. Cardiac magnetic resonance imaging (CMR) can be challenging in DMD patients due to study duration and patient discomfort. We developed an abbreviated CMR (aCMR) protocol and hypothesized that aCMR would compare favorably to echo in image quality and clinical utility without significant differences in exam duration, patient satisfaction, and functional measurements. METHODS: DMD patients were recruited prospectively to undergo echo and aCMR. Modalities were compared with a global quality assessment score (GQAS), clinical utility score (CUS), and patient satisfaction score (PSS). Results were compared using Wilcoxon signed-rank tests, Spearman correlations, intraclass correlations, and Bland-Altman analyses. RESULTS: Nineteen DMD patients were included. PSS scores and exam duration were equivalent between modalities, while CUS and GQAS scores favored aCMR. ACMR scored markedly higher than echo in RV visualization and assessment of atrial size. Older age was negatively correlated with echo GQAS and CUS scores, as well as aCMR PSS scores. Higher BMI was positively correlated with aCMR GQAS scores. Nighttime PPV requirement and non-ambulatory status were correlated with worse echo CUS scores. Poor image quality precluding quantification existed in five (26%) echo and zero (0%) aCMR studies. There was moderate correlation between aCMR and echo for global circumferential strain and left ventricular four chamber global longitudinal strain. CONCLUSION: The aCMR protocol resulted in improved clinical relevance and quality scores relative to echo, without significant detriment to patient satisfaction or exam duration.


Assuntos
Distrofia Muscular de Duchenne , Disfunção Ventricular Esquerda , Humanos , Distrofia Muscular de Duchenne/complicações , Distrofia Muscular de Duchenne/diagnóstico por imagem , Ecocardiografia/métodos , Satisfação do Paciente , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos
7.
Sci Rep ; 13(1): 22557, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110526

RESUMO

Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance imaging (MRI). A baseline patient-specific 3D-printed model and two variants with modified tear size (smaller entry tear, smaller exit tear) were embedded into a flow- and pressure-controlled setup to perform MRI as well as 12-point catheter-based pressure measurements. The same models defined the wall and fluid domains for FSI simulations, for which boundary conditions were matched with measured data. Results showed exceptionally well matched complex flow patterns between 4D-flow MRI and FSI simulations. Compared to the baseline model, false lumen flow volume decreased with either a smaller entry tear (- 17.8 and - 18.5%, for FSI simulation and 4D-flow MRI, respectively) or smaller exit tear (- 16.0 and - 17.3%). True to false lumen pressure difference (initially 11.0 and 7.9 mmHg, for FSI simulation and catheter-based pressure measurements, respectively) increased with a smaller entry tear (28.9 and 14.6 mmHg), and became negative with a smaller exit tear (- 20.6 and - 13.2 mmHg). This work establishes quantitative and qualitative effects of entry or exit tear size on hemodynamics in aortic dissection, with particularly notable impact observed on FL pressurization. FSI simulations demonstrate acceptable qualitative and quantitative agreement with flow imaging, supporting its deployment in clinical studies.


Assuntos
Dissecção Aórtica , Humanos , Dissecção Aórtica/diagnóstico por imagem , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Pressão , Modelos Cardiovasculares
8.
ArXiv ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37961745

RESUMO

Congenital heart disease (CHD) encompasses a spectrum of cardiovascular structural abnormalities, often requiring customized treatment plans for individual patients. Computational modeling and analysis of these unique cardiac anatomies can improve diagnosis and treatment planning and may ultimately lead to improved outcomes. Deep learning (DL) methods have demonstrated the potential to enable efficient treatment planning by automating cardiac segmentation and mesh construction for patients with normal cardiac anatomies. However, CHDs are often rare, making it challenging to acquire sufficiently large patient cohorts for training such DL models. Generative modeling of cardiac anatomies has the potential to fill this gap via the generation of virtual cohorts; however, prior approaches were largely designed for normal anatomies and cannot readily capture the significant topological variations seen in CHD patients. Therefore, we propose a type- and shape-disentangled generative approach suitable to capture the wide spectrum of cardiac anatomies observed in different CHD types and synthesize differently shaped cardiac anatomies that preserve the unique topology for specific CHD types. Our DL approach represents generic whole heart anatomies with CHD type-specific abnormalities implicitly using signed distance fields (SDF) based on CHD type diagnosis, which conveniently captures divergent anatomical variations across different types and represents meaningful intermediate CHD states. To capture the shape-specific variations, we then learn invertible deformations to morph the learned CHD type-specific anatomies and reconstruct patient-specific shapes. Our approach has the potential to augment the image-segmentation pairs for rarer CHD types for cardiac segmentation and generate cohorts of CHD cardiac meshes for computational simulation.

9.
medRxiv ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37732242

RESUMO

Purpose: Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and gauge treatment efficacy. Invasive cardiac catheterization is currently the gold-standard method for measuring blood pressure. The objective of this study was to evaluate the accuracy of ΔP estimates derived non-invasively using patient-specific 0D and 3D deformable wall simulations. Methods: Medical imaging and routine clinical measurements were used to create patient-specific models of patients with CoA (N=17). 0D simulations were performed first and used to tune boundary conditions and initialize 3D simulations. ΔP across the CoA estimated using both 0D and 3D simulations were compared to invasive catheter-based pressure measurements for validation. Results: The 0D simulations were extremely efficient (~15 secs computation time) compared to 3D simulations (~30 hrs computation time on a cluster). However, the 0D ΔP estimates, unsurprisingly, had larger mean errors when compared to catheterization than 3D estimates (12.1 ± 9.9 mmHg vs 5.3 ± 5.4 mmHg). In particular, the 0D model performance degraded in cases where the CoA was adjacent to a bifurcation. The 0D model classified patients with severe CoA requiring intervention (defined as ΔP≥20 mmHg) with 76% accuracy and 3D simulations improved this to 88%. Conclusion: Overall, a combined approach, using 0D models to efficiently tune and launch 3D models, offers the best combination of speed and accuracy for non-invasive classification of CoA severity.

10.
Radiol Cardiothorac Imaging ; 5(3): e220196, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37404792

RESUMO

Purpose: To develop a three-dimensional (two dimensions + time) convolutional neural network trained with displacement encoding with stimulated echoes (DENSE) data for displacement and strain analysis of cine MRI. Materials and Methods: In this retrospective multicenter study, a deep learning model (StrainNet) was developed to predict intramyocardial displacement from contour motion. Patients with various heart diseases and healthy controls underwent cardiac MRI examinations with DENSE between August 2008 and January 2022. Network training inputs were a time series of myocardial contours from DENSE magnitude images, and ground truth data were DENSE displacement measurements. Model performance was evaluated using pixelwise end-point error (EPE). For testing, StrainNet was applied to contour motion from cine MRI. Global and segmental circumferential strain (Ecc) derived from commercial feature tracking (FT), StrainNet, and DENSE (reference) were compared using intraclass correlation coefficients (ICCs), Pearson correlations, Bland-Altman analyses, paired t tests, and linear mixed-effects models. Results: The study included 161 patients (110 men; mean age, 61 years ± 14 [SD]), 99 healthy adults (44 men; mean age, 35 years ± 15), and 45 healthy children and adolescents (21 males; mean age, 12 years ± 3). StrainNet showed good agreement with DENSE for intramyocardial displacement, with an average EPE of 0.75 mm ± 0.35. The ICCs between StrainNet and DENSE and FT and DENSE were 0.87 and 0.72, respectively, for global Ecc and 0.75 and 0.48, respectively, for segmental Ecc. Bland-Altman analysis showed that StrainNet had better agreement than FT with DENSE for global and segmental Ecc. Conclusion: StrainNet outperformed FT for global and segmental Ecc analysis of cine MRI.Keywords: Image Postprocessing, MR Imaging, Cardiac, Heart, Pediatrics, Technical Aspects, Technology Assessment, Strain, Deep Learning, DENSE Supplemental material is available for this article. © RSNA, 2023.

11.
J Hypertens ; 41(10): 1606-1614, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37466436

RESUMO

BACKGROUND: Left ventricular (LV) global longitudinal strain (GLS) has been proposed as an early imaging biomarker of cardiac mechanical dysfunction. OBJECTIVE: To assess the impact of angiotensin-converting enzyme (ACE) inhibitor treatment of hypertensive heart disease on LV GLS and mechanical function. METHODS: The spontaneously hypertensive rat (SHR) model of hypertensive heart disease ( n  = 38) was studied. A subset of SHRs received quinapril (TSHR, n  = 16) from 3 months (mo). Wistar Kyoto rats (WKY, n  = 13) were used as controls. Tagged cardiac MRI was performed using a 4.7 T Varian preclinical scanner. RESULTS: The SHRs had significantly lower LV ejection fraction (EF) than the WKYs at 3 mo (53.0 ±â€Š1.7% vs. 69.6 ±â€Š2.1%, P  < 0.05), 14 mo (57.0 ±â€Š2.5% vs. 74.4 ±â€Š2.9%, P  < 0.05) and 24 mo (50.1 ±â€Š2.4% vs. 67.0 ±â€Š2.0%, P  < 0.01). At 24 mo, ACE inhibitor treatment was associated with significantly greater LV EF in TSHRs compared to untreated SHRs (64.2 ±â€Š3.4% vs. 50.1 ±â€Š2.4%, P  < 0.01). Peak GLS magnitude was significantly lower in SHRs compared with WKYs at 14 months (7.5% ±â€Š0.4% vs. 9.9 ±â€Š0.8%, P  < 0.05). At 24 months, Peak GLS magnitude was significantly lower in SHRs compared with both WKYs (6.5 ±â€Š0.4% vs. 9.7 ±â€Š1.0%, P  < 0.01) and TSHRs (6.5 ±â€Š0.4% vs. 9.6 ±â€Š0.6%, P  < 0.05). CONCLUSIONS: ACE inhibitor treatment curtails the decline in global longitudinal strain in hypertensive rats, with the treatment group exhibiting significantly greater LV EF and GLS magnitude at 24 mo compared with untreated SHRs.


Assuntos
Cardiopatias , Hipertensão , Ratos , Animais , Quinapril , Ratos Endogâmicos WKY , Deformação Longitudinal Global , Hipertensão/tratamento farmacológico , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Ratos Endogâmicos SHR , Pressão Sanguínea
12.
Bioengineering (Basel) ; 10(3)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36978725

RESUMO

Cardiac magnetic resonance (CMR) is an essential clinical tool for the assessment of cardiovascular disease. Deep learning (DL) has recently revolutionized the field through image reconstruction techniques that allow unprecedented data undersampling rates. These fast acquisitions have the potential to considerably impact the diagnosis and treatment of cardiovascular disease. Herein, we provide a comprehensive review of DL-based reconstruction methods for CMR. We place special emphasis on state-of-the-art unrolled networks, which are heavily based on a conventional image reconstruction framework. We review the main DL-based methods and connect them to the relevant conventional reconstruction theory. Next, we review several methods developed to tackle specific challenges that arise from the characteristics of CMR data. Then, we focus on DL-based methods developed for specific CMR applications, including flow imaging, late gadolinium enhancement, and quantitative tissue characterization. Finally, we discuss the pitfalls and future outlook of DL-based reconstructions in CMR, focusing on the robustness, interpretability, clinical deployment, and potential for new methods.

13.
ArXiv ; 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36994169

RESUMO

Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance imaging (MRI). A baseline patient-specific 3D-printed model and two variants with modified tear size (smaller entry tear, smaller exit tear) were embedded into a flow- and pressure-controlled setup to perform MRI as well as 12-point catheter-based pressure measurements. The same models defined the wall and fluid domains for FSI simulations, for which boundary conditions were matched with measured data. Results showed exceptionally well matched complex flow patterns between 4D-flow MRI and FSI simulations. Compared to the baseline model, false lumen flow volume decreased with either a smaller entry tear (-17.8 and -18.5 %, for FSI simulation and 4D-flow MRI, respectively) or smaller exit tear (-16.0 and -17.3 %). True to false lumen pressure difference (initially 11.0 and 7.9 mmHg, for FSI simulation and catheter-based pressure measurements, respectively) increased with a smaller entry tear (28.9 and 14.6 mmHg), and became negative with a smaller exit tear (-20.6 and -13.2 mmHg). This work establishes quantitative and qualitative effects of entry or exit tear size on hemodynamics in aortic dissection, with particularly notable impact observed on FL pressurization. FSI simulations demonstrate acceptable qualitative and quantitative agreement with flow imaging, supporting its deployment in clinical studies.

14.
Ann Biomed Eng ; 51(7): 1574-1587, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36914919

RESUMO

Impaired cardiac filling in response to increased passive myocardial stiffness contributes to the pathophysiology of heart failure. By leveraging cardiac MRI data and ventricular pressure measurements, we can estimate in vivo passive myocardial stiffness using personalized inverse finite element models. While it is well-known that this approach is subject to uncertainties, only few studies quantify the accuracy of these stiffness estimates. This lack of validation is, at least in part, due to the absence of ground truth in vivo passive myocardial stiffness values. Here, using 3D printing, we created soft, homogenous, isotropic, hyperelastic heart phantoms of varying geometry and stiffness and simulate diastolic filling by incorporating the phantoms into an MRI-compatible left ventricular inflation system. We estimate phantom stiffness from MRI and pressure data using inverse finite element analyses based on a Neo-Hookean model. We demonstrate that our identified softest and stiffest values of 215.7 and 512.3 kPa agree well with the ground truth of 226.2 and 526.4 kPa. Overall, our estimated stiffnesses revealed a good agreement with the ground truth ([Formula: see text] error) across all models. Our results suggest that MRI-driven computational constitutive modeling can accurately estimate synthetic heart material stiffnesses in the range of 200-500 kPa.


Assuntos
Coração , Modelos Cardiovasculares , Coração/diagnóstico por imagem , Miocárdio , Ventrículos do Coração , Imageamento por Ressonância Magnética/métodos
17.
Bioengineering (Basel) ; 10(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36829660

RESUMO

The use of deep learning (DL) segmentation in cardiac MRI has the potential to streamline the radiology workflow, particularly for the measurement of myocardial strain. Recent efforts in DL motion tracking models have drastically reduced the time needed to measure the heart's displacement field and the subsequent myocardial strain estimation. However, the selection of initial myocardial reference points is not automated and still requires manual input from domain experts. Segmentation of the myocardium is a key step for initializing reference points. While high-performing myocardial segmentation models exist for cine images, this is not the case for tagged images. In this work, we developed and compared two novel DL models (nnU-net and Segmentation ResNet VAE) for the segmentation of myocardium from tagged CMR images. We implemented two methods to transform cardiac cine images into tagged images, allowing us to leverage large public annotated cine datasets. The cine-to-tagged methods included (i) a novel physics-driven transformation model, and (ii) a generative adversarial network (GAN) style transfer model. We show that pretrained models perform better (+2.8 Dice coefficient percentage points) and converge faster (6×) than models trained from scratch. The best-performing method relies on a pretraining with an unpaired, unlabeled, and structure-preserving generative model trained to transform cine images into their tagged-appearing equivalents. Our state-of-the-art myocardium segmentation network reached a Dice coefficient of 0.828 and 95th percentile Hausdorff distance of 4.745 mm on a held-out test set. This performance is comparable to existing state-of-the-art segmentation networks for cine images.

18.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36583628

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Feminino , Estudos Prospectivos , Decúbito Ventral , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar/métodos
19.
Magn Reson Med ; 89(1): 356-369, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36093915

RESUMO

PURPOSE: To develop and validate a deep learning-based reconstruction framework for highly accelerated two-dimensional (2D) phase contrast (PC-MRI) data with accurate and precise quantitative measurements. METHODS: We propose a modified DL-ESPIRiT reconstruction framework for 2D PC-MRI, comprised of an unrolled neural network architecture with a Complex Difference estimation (CD-DL). CD-DL was trained on 155 fully sampled 2D PC-MRI pediatric clinical datasets. The fully sampled data ( n = 29 $$ n=29 $$ ) was retrospectively undersampled (6-11 × $$ \times $$ ) and reconstructed using CD-DL and a parallel imaging and compressed sensing method (PICS). Measurements of peak velocity and total flow were compared to determine the highest acceleration rate that provided accuracy and precision within ± 5 % $$ \pm 5\% $$ . Feasibility of CD-DL was demonstrated on prospectively undersampled datasets acquired in pediatric clinical patients ( n = 5 $$ n=5 $$ ) and compared to traditional parallel imaging (PI) and PICS. RESULTS: The retrospective evaluation showed that 9 × $$ \times $$ accelerated 2D PC-MRI images reconstructed with CD-DL provided accuracy and precision (bias, [95 % $$ \% $$ confidence intervals]) within ± 5 % $$ \pm 5\% $$ . CD-DL showed higher accuracy and precision compared to PICS for measurements of peak velocity (2.8 % $$ \% $$ [ - 2 . 9 $$ -2.9 $$ , 4.5] vs. 3.9 % $$ \% $$ [ - 11 . 0 $$ -11.0 $$ , 4.9]) and total flow (1.8 % $$ \% $$ [ - 3 . 9 $$ -3.9 $$ , 3.4] vs. 2.9 % $$ \% $$ [ - 7 . 1 $$ -7.1 $$ , 6.9]). The prospective feasibility study showed that CD-DL provided higher accuracy and precision than PICS for measurements of peak velocity and total flow. CONCLUSION: In a retrospective evaluation, CD-DL produced quantitative measurements of 2D PC-MRI peak velocity and total flow with ≤ 5 % $$ \le 5\% $$ error in both accuracy and precision for up to 9 × $$ \times $$ acceleration. Clinical feasibility was demonstrated using a prospective clinical deployment of our 8 × $$ \times $$ undersampled acquisition and CD-DL reconstruction in a cohort of pediatric patients.


Assuntos
Aprendizado Profundo , Humanos , Criança , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética , Microscopia de Contraste de Fase
20.
Ann Biomed Eng ; 51(2): 377-393, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35963921

RESUMO

We previously introduced and verified the reduced unified continuum formulation for vascular fluid-structure interaction (FSI) against Womersley's deformable wall theory. Our present work seeks to investigate its performance in a patient-specific aortic setting in which assumptions of idealized geometries and velocity profiles are invalid. Specifically, we leveraged 2D magnetic resonance imaging (MRI) and 4D-flow MRI to extract high-resolution anatomical and hemodynamic information from an in vitro flow circuit embedding a compliant 3D-printed aortic phantom. To accurately reflect experimental conditions, we numerically implemented viscoelastic external tissue support, vascular tissue prestressing, and skew boundary conditions enabling in-plane vascular motion at each inlet and outlet. Validation of our formulation is achieved through close quantitative agreement in pressures, lumen area changes, pulse wave velocity, and early systolic velocities, as well as qualitative agreement in late systolic flow structures. Our validated suite of FSI techniques offers a computationally efficient approach for numerical simulation of vascular hemodynamics. This study is among the first to validate a cardiovascular FSI formulation against an in vitro flow circuit involving a compliant vascular phantom of complex patient-specific anatomy.


Assuntos
Imageamento por Ressonância Magnética , Análise de Onda de Pulso , Humanos , Hemodinâmica , Aorta/diagnóstico por imagem , Simulação por Computador , Velocidade do Fluxo Sanguíneo , Modelos Cardiovasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...