Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Med Sci ; 83(5): 863-868, 2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-33790088

RESUMO

Cleanliness of milking equipment is known to be important for the safety of dairy products and to prevent the spread of diseases among cows. We investigated the cleaning procedures of milking equipment and suckling equipment on Japanese dairy farms, and the cleanliness of bucket milkers, suckling buckets, milk receivers, and bulk tanks, using adenosine triphosphate (ATP) bioluminescence test. Bulk tanks (except one bulk tank) and milk receivers were washed by automated cleaning, but all bucket milkers and suckling buckets were washed by manual cleaning. Detergents were often not used to clean bucket milkers and suckling buckets. The log10 transformed relative luminescence units (LRLU) of equipment washed by manual cleaning was higher than equipment washed by automated cleaning. Clean surfaces (≤2.2 LRLU) were only observed on the bulk tank and the milk receiver. More than 50% of the LRLU of the mouthpiece, the rubber packing of claw, and the nipple of the suckling bucket were determined dirty. These results suggest that the cleanliness of the bucket milkers and the suckling buckets washed by manual cleaning was lower than that of the equipment washed by automated cleaning, and may be due to insufficient cleaning procedures.


Assuntos
Indústria de Laticínios , Leite , Animais , Bovinos , Fazendas , Feminino , Japão
2.
Anim Sci J ; 92(1): e13502, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33403781

RESUMO

The immune response during the onset of coliform mastitis in vaccinated cows was investigated by measuring lactoferrin (LF), interleukin-8 (IL-8), and interleukin-1ß (IL-1ß) concentrations and somatic cell counts in 28 milk samples at the onset of acute coliform mastitis (ACM) and 73 milk samples at the onset of peracute coliform mastitis (PCM). Vaccinated ACM, unvaccinated ACM, and vaccinated PCM showed significantly higher values for LF and IL-1ß levels than unvaccinated PCM (p < .01). The IL-8 concentration was lower in vaccinated PCM than in unvaccinated PCM (p < .05). There was no significant difference in somatic cell counts for each parameter. There were no significant differences in the parameters between vaccinated and unvaccinated ACM cows, or vaccinated ACM and PCM cows. From the above results, it is suggested that mastitis vaccination improved the early immune response, particularly at the onset of PCM, and played a large role in host defense against the initial infection.


Assuntos
Vacinas Bacterianas/imunologia , Infecções por Enterobacteriaceae , Enterobacteriaceae/imunologia , Mastite Bovina/imunologia , Mastite Bovina/microbiologia , Vacinação/veterinária , Animais , Bovinos , Contagem de Células , Feminino , Interleucina-1beta/metabolismo , Interleucina-8/metabolismo , Lactoferrina/metabolismo , Leite/citologia , Leite/imunologia , Leite/metabolismo
3.
Anim Sci J ; 91(1): e13389, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32515521

RESUMO

Efforts to improve dairy performance have been focused on increasing milk productivity of cows through improved feeding systems and genetic potential. However, methods for evaluating milking system performance based on milk productivity have not yet been established. Milking system performance was evaluated by measuring the claw vacuum at five flow rates (1.9-8.7 kg/min) produced using a flow simulator for a single eight-swing milking parlor with a high-line system. Based on these results, a double eight-parallel milking parlor with a low-line system was installed and tested. Farmers can take data obtained from evaluations of milking system performance into account for future management decisions, such as renewing the milking system. By renewing the milking system, average milking productivity, somatic cell linear score (LS) of bulk milk, and LS of each cow were significantly improved in the year after installing the new system (p < .01). In addition to checking conventional milking systems, this novel diagnostic method using a flow simulator can be used for checking new installations and also for proposing renovations.


Assuntos
Bovinos/metabolismo , Bovinos/fisiologia , Indústria de Laticínios/instrumentação , Lactação/fisiologia , Leite/metabolismo , Animais , Indústria de Laticínios/métodos , Feminino , Qualidade dos Alimentos
4.
Anim Sci J ; 91(1): e13315, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31755160

RESUMO

To prevent mastitis caused by inappropriate milking systems, inspection of the system, and maintenance of optimal function are crucial. This study aimed to clarify the problems with milking systems in Japan by analyzing the results of milking system inspections over the past 21 years. A total of 190 dairy farms (358 systems; 153 high-line systems, 205 low-line systems) were inspected for the checkpoints of problems originating from installation (PI) or problems originating from insufficient maintenance (PIM). Results were divided into initial and periodic inspections, then analyzed by year of inspection or years elapsed since equipment installation. With increasing years, inadequacy of milk piping and regulator maintenance tended to increase for high-line systems. On the other hand, defects in milking units tended to increase for low-line systems. This difference was attributed to the structures of these milking systems. The present study revealed potential problem areas in high- and low-line milking systems from recent years. To maintain normal functioning in milking systems, the frequency and content of inspections as currently being conducted need to be reviewed.


Assuntos
Indústria de Laticínios/instrumentação , Falha de Equipamento/veterinária , Fazendas , Manutenção/métodos , Mastite Bovina/prevenção & controle , Animais , Bovinos , Indústria de Laticínios/métodos , Feminino , Japão , Fatores de Tempo
5.
Anim Sci J ; 88(8): 1134-1140, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27892648

RESUMO

Milking performance of milking machines that matches the production capability of dairy cows is important in reducing the risk of mastitis, particularly in high-producing cows. This study used a simulated milking device to examine the milking performance of the milking system of 73 dairy farms and to analyze the factors affecting claw vacuum. Mean claw vacuum and range of fluctuation of claw vacuum (claw vacuum range) were measured at three different flow rates: 5.7, 7.6 and 8.7 kg/min. At the highest flow rate, only 16 farms (21.9%) met both standards of mean claw vacuum ≥35 kPa and claw vacuum range ≤ 7 kPa, showing that milking systems currently have poor milking performance. The factors affecting mean claw vacuum were claw type, milk-meter and vacuum shut-off device; the factor affecting claw vacuum range was claw type. Examination of the milking performance of the milking system using a simulated milking device allows an examination of the performance that can cope with high producing cows, indicating the possibility of reducing the risk of mastitis caused by inappropriate claw vacuum.


Assuntos
Bovinos/fisiologia , Indústria de Laticínios/instrumentação , Lactação , Vácuo , Animais , Feminino , Mastite Bovina/prevenção & controle
6.
Anim Sci J ; 87(6): 848-54, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26336796

RESUMO

Bovine mastitis is typically caused by microbial infection of the udder, but the factors responsible for this condition are varied. One potential cause is the milking system, and although previous studies have investigated various methods for inspecting these devices, most have not assessed methods for evaluating the milking units. With this in mind, we analyzed the factors that affect the vacuum inside the milking claw by using a simulated milking device and by measuring milking claw vacuum when adjusting the flow rate in five stages. The factors analyzed in each milking system were the vacuum pressure settings (high and low line system) , milk tube length (200-328 cm), aperture diameter (14-22.2 mm), constricted aperture diameter (12 mm), tubing configurations, lift formation (0-80 cm), claw type (bottom and top flow) and use or non-use of a milk sampler. The study findings demonstrated that all of these variables had a significant impact on claw vacuum and suggest that a diagnostic method using a simulated milking device should be considered when inspecting modern milking systems.


Assuntos
Indústria de Laticínios/instrumentação , Desenho de Equipamento/veterinária , Segurança de Equipamentos/métodos , Leite , Vácuo , Animais , Bovinos , Feminino , Mastite Bovina/etiologia , Mastite Bovina/prevenção & controle , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...