Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 43(4): 947-55, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26451972

RESUMO

BACKGROUND: The purpose of this study was to evaluate a recently developed two-dimensional (2D) image-based navigation approach (iNAVG+C ) combined with respiratory bellows gating for CMRA in patients with congenital heart disease. METHODS: Nine healthy volunteers (mean age 32 ± 6 years [standard deviation]) and 29 patients (28 ± 9 years) were scanned on a 1.5 Tesla clinical scanner using iNAV(G+C) motion compensated T2prepared CMRA, and the conventional 1D NAV approach. Scan time was recorded for each CMRA scan. An image quality score was given to each coronary artery from (0, uninterpretable; to 4, excellent image quality). Additionally, vessel sharpness of each coronary artery was measured. RESULTS: Average scan time was significantly shorter (P < 0.01) using the proposed iNAVC+G approach (7:57 ± 1:34) compared with 1D NAV (9:15 ± 3:02). Improved visual scores of the right coronary artery (iNAV(G+C) : 4,3,4 (median, 25th percentile, 75th percentile) versus 1D NAV: 3,3,4; P < 0.001) and left anterior descending artery (iNAV(G+C) : 3,3,4 versus 1D NAV: 3,2,3; P < 0.001) were obtained using iNAV(G+C) compared with 1D NAV as well as an increased vessel sharpness of the right coronary artery (iNAV(G+C) : 65.3% ± 6.6% (mean ± standard deviation) versus 1D NAV: 60.2% ± 11.4%; P < 0.05) and left anterior descending artery (iNAV(G+C) : 63.2% ± 6.7% versus 1D NAV: 58.3% ± 9.5%; P < 0.05). CONCLUSION: Image-based navigation in combination with respiratory bellows gating allows for more robust suppression of respiratory motion artifacts for whole-heart CMRA compared with conventional 1D NAV as images can be acquired in a shorter time and with improved image quality.


Assuntos
Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Feminino , Voluntários Saudáveis , Cardiopatias Congênitas/patologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Movimento (Física) , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA