Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Aesthet Surg J ; 43(3): 389-391, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36514920
2.
Vet Clin North Am Small Anim Pract ; 50(4): 789-809, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32386771

RESUMO

Neuropathic pain represents the extreme in maladaptive pain processing. In itself, it is a disease in which pain has become exaggerated in some combination of scope, severity, character, field, duration, and spontaneity. It is almost certainly an underappreciated, underdiagnosed cause of possible significant patient morbidity in cats. This article explores the basic mechanisms, recognition, known and suspect syndromes, and prospective treatment of feline maladaptive and neuropathic pain.


Assuntos
Doenças do Gato/fisiopatologia , Neuralgia/veterinária , Animais , Gatos , Neuralgia/fisiopatologia
4.
Quant Imaging Med Surg ; 5(5): 673-84, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26682137

RESUMO

BACKGROUND: Current measurement of the single longest dimension of a polyp is subjective and has variations among radiologists. Our purpose was to develop a computerized measurement of polyp volume in computed tomography colonography (CTC). METHODS: We developed a 3D automated scheme for measuring polyp volume at CTC. Our scheme consisted of segmentation of colon wall to confine polyp segmentation to the colon wall, extraction of a highly polyp-like seed region based on the Hessian matrix, a 3D volume growing technique under the minimum surface expansion criterion for segmentation of polyps, and sub-voxel refinement and surface smoothing for obtaining a smooth polyp surface. Our database consisted of 30 polyp views (15 polyps) in CTC scans from 13 patients. Each patient was scanned in the supine and prone positions. Polyp sizes measured in optical colonoscopy (OC) ranged from 6-18 mm with a mean of 10 mm. A radiologist outlined polyps in each slice and calculated volumes by summation of volumes in each slice. The measurement study was repeated 3 times at least 1 week apart for minimizing a memory effect bias. We used the mean volume of the three studies as "gold standard". RESULTS: Our measurement scheme yielded a mean polyp volume of 0.38 cc (range, 0.15-1.24 cc), whereas a mean "gold standard" manual volume was 0.40 cc (range, 0.15-1.08 cc). The "gold-standard" manual and computer volumetric reached excellent agreement (intra-class correlation coefficient =0.80), with no statistically significant difference [P (F≤f) =0.42]. CONCLUSIONS: We developed an automated scheme for measuring polyp volume at CTC based on Hessian matrix-based shape extraction and volume growing. Polyp volumes obtained by our automated scheme agreed excellently with "gold standard" manual volumes. Our fully automated scheme can efficiently provide accurate polyp volumes for radiologists; thus, it would help radiologists improve the accuracy and efficiency of polyp volume measurements in CTC.

5.
Clin Plast Surg ; 42(4): 437-50, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26408435

RESUMO

This article discusses perception of three-dimensional objects and binocular vision. High-resolution three-dimensional images of the breast can be captured using a camera system consisting of 3 separate stereoscopic pairs of digital cameras. The images (surfaces) are then joined to form a 220° surface of the torso, including the breasts. The images can be rotated freely in space. Simulation of augmentation with or without mastopexy is presented. Three-dimensional imaging and computer simulation of breast augmentation has become an emerging technology in many breast augmentation practices. This technology can be integrated in different ways into the consultation and informed consent process.


Assuntos
Mama/cirurgia , Simulação por Computador , Imageamento Tridimensional , Mamoplastia/métodos , Algoritmos , Comunicação , Feminino , Humanos , Software
6.
J Am Anim Hosp Assoc ; 51(2): 67-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25764070

RESUMO

The robust advances in pain management for companion animals underlie the decision of AAHA and AAFP to expand on the information provided in the 2007 AAHA/AAFP Pain Management Guidelines for Dogs and Cats . The 2015 guidelines summarize and offer a discriminating review of much of this new knowledge. Pain management is central to veterinary practice, alleviating pain, improving patient outcomes, and enhancing both quality of life and the veterinarian-client-patient relationship. The management of pain requires a continuum of care that includes anticipation, early intervention, and evaluation of response on an individual-patient basis. The guidelines include both pharmacologic and nonpharmacologic modalities to manage pain; they are evidence-based insofar as possible and otherwise represent a consensus of expert opinion. Behavioral changes are currently the principal indicator of pain and its course of improvement or progression, and the basis for recently validated pain scores. A team-oriented approach, including the owner, is essential for maximizing the recognition, prevention, and treatment of pain in animals. Postsurgical pain is eminently predictable but a strong body of evidence exists supporting strategies to mitigate adaptive as well as maladaptive forms. Degenerative joint disease is one of the most significant and under-diagnosed diseases of cats and dogs. Degenerative joint disease is ubiquitous, found in pets of all ages, and inevitably progresses over time; evidence-based strategies for management are established in dogs, and emerging in cats. These guidelines support veterinarians in incorporating pain management into practice, improving patient care.


Assuntos
Doenças do Gato/terapia , Doenças do Cão/terapia , Dor/veterinária , Guias de Prática Clínica como Assunto/normas , Terapia por Acupuntura/veterinária , Analgésicos/uso terapêutico , Animais , Comportamento Animal , Gatos , Doença Crônica , Cães , Hospitais Veterinários/organização & administração , Hospitais Veterinários/normas , Medição da Dor/veterinária , Sociedades Científicas/organização & administração , Sociedades Científicas/normas , Estados Unidos , Medicina Veterinária/organização & administração , Medicina Veterinária/normas
7.
J Feline Med Surg ; 17(3): 251-72, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25701863

RESUMO

RATIONALE: The robust advances in pain management for companion animals underlie the decision of the American Animal Hospital Association (AAHA) and American Association of Feline Practitioners (AAFP) to expand on the information provided in the 2007 AAHA/AAFP Pain Management Guidelines. The 2015 Guidelines summarize and offer a discriminating review of much of this new knowledge. RELEVANCE: Pain management is central to veterinary practice, alleviating pain, improving patient outcomes, and enhancing both quality of life and the veterinarian-client-patient relationship. These Guidelines support veterinarians in incorporating pain management into practice, improving patient care. APPROACHES: The management of pain requires a continuum of care that includes anticipation, early intervention, and evaluation of response on an individual patient basis. A team-oriented approach, including the owner, is essential for maximizing the recognition, prevention and treatment of pain in animals. EVIDENCE BASE: The Guidelines include both pharmacologic and non-pharmacologic modalities to manage pain; they are evidence-based insofar as possible and otherwise represent a consensus of expert opinion. Behavioral changes are currently the principal indicator of pain and its course of improvement or progression, and the basis for recently validated pain scores. Post-surgical pain is eminently predictable but a strong body of evidence exists supporting strategies to mitigate adaptive as well as maladaptive forms. Chronic pain is dominated by degenerative joint disease (DJD), which is one of the most significant and under-diagnosed diseases of cats and dogs. DJD is ubiquitous, found in pets of all ages, and inevitably progresses over time; evidence-based strategies for management are established in dogs, and emerging in cats.


Assuntos
Analgesia/veterinária , Doenças do Gato/tratamento farmacológico , Doenças do Cão/tratamento farmacológico , Medição da Dor/veterinária , Dor/veterinária , Medicina Veterinária/normas , Analgesia/métodos , Analgesia/normas , Analgésicos/uso terapêutico , Animais , Doenças do Gato/prevenção & controle , Gatos , Consenso , Doenças do Cão/prevenção & controle , Cães , Diretrizes para o Planejamento em Saúde , Dor/tratamento farmacológico , Dor/prevenção & controle , Medição da Dor/métodos , Medição da Dor/normas , Padrões de Prática Médica/normas , Sociedades Médicas , Estados Unidos , Médicos Veterinários/normas
8.
Top Companion Anim Med ; 29(2): 30-4, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25454373

RESUMO

Outside the realm of nonsteroidal antiinflammatory drug(NSAID) and opioid exist a broad range of medications that exert an analgesic effect, or otherwise modify and protect against pain, by manipulating various targets along the nociceptive pathway. Strength of evidence for dogs and cats can vary widely, and this article will review the available literature that may guide clinical usage in these species.


Assuntos
Adjuvantes Anestésicos/administração & dosagem , Gatos/fisiologia , Cães/fisiologia , Dor/veterinária , Analgesia/veterinária , Animais , Dor/prevenção & controle , Medicina Veterinária
10.
Bioconjug Chem ; 24(9): 1552-61, 2013 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-23941326

RESUMO

The CyDye family of fluorescent dyes is currently the overwhelming choice for applications in proteomic analysis, using two-dimensional difference gel electrophoresis (2D-DIGE). Protein labeling with CyDyes is hampered by protein precipitation and gel smearing when used above minimal labeling. The solubility of labeled protein may be improved by introducing water solubilizing groups on the dye such as cysteic acids. However, addition of a negatively charged functionality will have the undesired effect of shifting the pI in relation to the unlabeled protein. These limitations have been addressed through the synthesis of highly water-soluble and pI balancing zwitterionic CyDye fluorophores (Z-CyDyes). The new dyes feature a cysteic acid motif, a titratable amine functionality and a NHS activated ester group. In side by side 2D-DIGE comparisons of Z-CyDyes and CyDyes, the new dyes significantly enhanced protein spot volume and the number of spots that were detected. Z-CyDyes have the potential to enhance the depth of proteome coverage and provide a general strategy for improving the performance of protein tagging reagents.


Assuntos
Proteínas Arqueais/análise , Cisteína/análogos & derivados , Eletroforese em Gel Bidimensional/métodos , Corantes Fluorescentes/análise , Proteômica/métodos , Sulfolobus solfataricus/química , Carbocianinas/análise , Solubilidade , Coloração e Rotulagem/métodos , Água/química
11.
J Pediatr ; 161(5): 927-32, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22704249

RESUMO

OBJECTIVES: To describe the efficacy and outcome of dexmedetomidine (Dex) via the intramuscular (IM) route for sedation for electroencephalography (EEG). STUDY DESIGN: Quality assurance data and EEG studies were reviewed for consecutive patients who received IM Dex for EEGs between August 2007 and September 2009. Sleep spindles, delta waves, and beta activity were evaluated to determine the deepest stage of sleep achieved. RESULTS: One hundred seven consecutive children (age 0.2-17 years) between August 2007 and September 2009 received IM Dex (range 1.0-4.5 mcg/kg). The average time to achieve sedation was 15.5 minutes (range 3.0-55.0) with an average of 54.5 minutes to meet discharge criteria following EEG studies, which averaged 34.2 ± 22.6 minutes. The deepest stage of sleep recorded for each child was: awake (n = 1), stage N2 (n = 51), and stage N3 (n = 55). Excessive beta activity was seen in only 1 patient. Epileptiform activity was noted in 11 patients. Hemodynamic fluctuations in heart rate and blood pressure were noted, none of which required pharmacologic intervention. All EEGs were successfully completed. CONCLUSION: We describe Stage 3 sleep and preserved background activity in response to Dex. We present the IM route as a new method, which preserves background EEG activity to provide safe and effective sedation for EEG studies.


Assuntos
Sedação Profunda/métodos , Dexmedetomidina/administração & dosagem , Eletroencefalografia/métodos , Injeções Intramusculares/métodos , Adolescente , Pressão Sanguínea/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipnóticos e Sedativos/farmacologia , Lactente , Recém-Nascido , Masculino , Pediatria/métodos , Sono , Fases do Sono
12.
AJR Am J Roentgenol ; 197(4): W706-12, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21940543

RESUMO

OBJECTIVE: The purpose of this study was to evaluate automated CT volumetry in the assessment of living-donor livers for transplant and to compare this technique with software-aided interactive volumetry and manual volumetry. MATERIALS AND METHODS: Hepatic CT scans of 18 consecutively registered prospective liver donors were obtained under a liver transplant protocol. Automated liver volumetry was developed on the basis of 3D active-contour segmentation. To establish reference standard liver volumes, a radiologist manually traced the contour of the liver on each CT slice. We compared the results obtained with automated and interactive volumetry with those obtained with the reference standard for this study, manual volumetry. RESULTS: The average interactive liver volume was 1553 ± 343 cm(3), and the average automated liver volume was 1520 ± 378 cm(3). The average manual volume was 1486 ± 343 cm(3). Both interactive and automated volumetric results had excellent agreement with manual volumetric results (intraclass correlation coefficients, 0.96 and 0.94). The average user time for automated volumetry was 0.57 ± 0.06 min/case, whereas those for interactive and manual volumetry were 27.3 ± 4.6 and 39.4 ± 5.5 min/case, the difference being statistically significant (p < 0.05). CONCLUSION: Both interactive and automated volumetry are accurate for measuring liver volume with CT, but automated volumetry is substantially more efficient.


Assuntos
Transplante de Fígado , Fígado/anatomia & histologia , Fígado/diagnóstico por imagem , Doadores Vivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Automação , Meios de Contraste/administração & dosagem , Feminino , Humanos , Imageamento Tridimensional , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Software
13.
Liver Transpl ; 17(12): 1427-36, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21850689

RESUMO

The purpose of this study was to evaluate the relationship between the slice thickness and the calculated volume in computed tomography (CT) liver volumetry through the comparison of the results from images [including 3-dimensional (3D) images] with various slice thicknesses. Twenty potential adult liver donors (12 men and 8 women) with a mean age of 39 years (range = 24-64 years) underwent CT with a 64-section multidetector row CT scanner after the intravenous injection of a contrast material. Four image sets with slice thicknesses of 0.625, 2.5, 5, and 10 mm were used. First, a program developed in our laboratory for automated liver extraction was applied to the CT images, and the liver boundaries were determined automatically. Then, an abdominal radiologist reviewed all images onto which automatically extracted boundaries had been superimposed and then edited the boundaries on each slice to enhance the accuracy. The liver volumes were determined via the counting of the voxels within the liver boundaries. The mean whole liver volumes estimated with CT were 1322.5 cm(3) from 0.625-mm images, 1313.3 cm(3) from 2.5-mm images, 1310.3 cm(3) from 5-mm images, and 1268.2 cm(3) from 10-mm images. The volumes calculated from 3D (0.625-mm) images were significantly larger than the volumes calculated from thicker images (P < 0.001). The partial liver volumes of right lobes, left lobes, and lateral segments were evaluated in a similar manner. The estimated maximum difference in the calculated volumes of lateral segments was -10.9 cm(3) (-4.63%) between 0.625- and 5-mm images. In conclusion, liver volumes calculated from 2.5-mm-thick or thicker images are significantly smaller than liver volumes calculated from 3D images. If a maximum error of 5% in the calculated graft volume will not have a significant clinical impact, 5-mm-thick images are acceptable for CT volumetry. If the impact is significant, 3D images could be essential.


Assuntos
Hepatectomia , Imageamento Tridimensional , Transplante de Fígado , Fígado/diagnóstico por imagem , Fígado/cirurgia , Doadores Vivos , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Simulação por Computador , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Análise Numérica Assistida por Computador , Tamanho do Órgão , Valor Preditivo dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
Med Phys ; 37(5): 2159-66, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20527550

RESUMO

PURPOSE: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as "gold standard." RESULTS: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F = 0.77; p(F < or = f) = 0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). CONCLUSIONS: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Processamento de Imagem Assistida por Computador/normas , Tamanho do Órgão , Padrões de Referência
16.
Clin Infect Dis ; 44(3): 431-7, 2007 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-17205454

RESUMO

BACKGROUND: Studies of the progression liver fibrosis in human immunodeficiency virus (HIV) and hepatitis C virus-coinfected patients suggest that cirrhosis is associated with immunosuppression, as measured by low absolute CD4(+) T cell counts. However, we hypothesized that, in patients with advanced liver disease, low CD4(+) T cell counts may occur secondary to portal hypertension and splenic sequestration, regardless of the presence or absence of HIV infection. METHODS: Sixty HIV-seronegative outpatients with cirrhosis were enrolled during the period 2001-2003 in a prospective, cross-sectional study of the association between liver disease and CD4(+) T cell counts and percentages. Demographic characteristics, liver disease-related characteristics, and laboratory results--including CD4(+) T cell parameters--were collected. RESULTS: A total of 39 patients (65%) had a low CD4(+) T cell count; 26 patients (43%) and 4 patients (7%) had CD4(+) T cell counts <350 and <200 cells/mm(3), respectively. Abnormal CD4(+) T cell counts were associated with splenomegaly (P=.03), thrombocytopenia (P=.002), and leukopenia (P<.001). The percentage of CD4(+) T cells was normal in 95% of patients who had a low absolute CD4(+) T cell count. CD4(+) T cell counts were significantly lower among cirrhotic patients than among 7638 HIV-seronegative historic control subjects without liver disease. CONCLUSIONS: Cirrhosis is associated with low CD4(+) T cell counts in the absence of HIV infection. Discordance between low absolute CD4(+) T cell counts and normal CD4(+) T cell percentages may be attributable to portal hypertension and splenic sequestration. Our findings have significant implications for the use and interpretation of absolute CD4(+) T cell counts in HIV-infected patients with advanced liver disease.


Assuntos
Contagem de Linfócito CD4 , Linfócitos T CD4-Positivos/citologia , Hipertensão Portal/complicações , Cirrose Hepática/sangue , Cirrose Hepática/imunologia , Esplenomegalia/sangue , Adulto , Linfócitos T CD4-Positivos/fisiologia , Estudos Transversais , Feminino , Humanos , Hipertensão Portal/imunologia , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
20.
J Am Anim Hosp Assoc ; 41(2): 81-91, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15767650

RESUMO

This paper provides a working framework for enhancing the well-being of senior pet dogs and cats. Approaches to screening the medical status of senior pets are described in detail, with particular emphasis on establishing baseline data in healthy animals, the testing of clinically ill animals, and assessing senior pets prior to anesthesia and surgery. The management of pain and distress and the application of hospice and palliative care are addressed. Advice on ways to approach euthanasia and dealing with end-of-life issues is also provided.


Assuntos
Envelhecimento , Bem-Estar do Animal , Doenças do Gato/diagnóstico , Doenças do Cão/diagnóstico , Eutanásia Animal , Envelhecimento/patologia , Envelhecimento/fisiologia , Anestesia/efeitos adversos , Anestesia/veterinária , Animais , Doenças do Gato/psicologia , Doenças do Gato/terapia , Gatos/fisiologia , Doença Crônica , Gerenciamento Clínico , Doenças do Cão/psicologia , Doenças do Cão/terapia , Cães/fisiologia , Feminino , Vínculo Humano-Animal , Humanos , Masculino , Cuidados Paliativos , Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...