Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Resusc Plus ; 6: 100117, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34223376

RESUMO

STUDY AIM: To determine the impact of high-frequency CPR training on performance during simulated and real pediatric CPR events in a pediatric emergency department (ED). METHODS: Prospective observational study. A high-frequency CPR training program (Resuscitation Quality Improvement (RQI)) was implemented among ED providers in a children's hospital. Data on CPR performance was collected longitundinally during quarterly retraining sessions; scores were analyzed between quarter 1 and quarter 4 by nonparametric methods. Data on CPR performance during actual patient events was collected by simultaneous combination of video review and compression monitor devices to allow measurement of CPR quality by individual providers; linear mixed effects models were used to analyze the association between RQI components and CPR quality. RESULTS: 159 providers completed four consecutive RQI sessions. Scores for all CPR tasks during retraining sessions significantly improved during the study period. 28 actual CPR events were captured during the study period; 49 observations of RQI trained providers performing CPR on children were analyzed. A significant association was found between the number of prior RQI sessions and the percent of compressions meeting guidelines for rate (ß coefficient -0.08; standard error 0.04; p = 0.03). CONCLUSIONS: Over a 15 month period, RQI resulted in improved performance during training sessions for all skills. A significant association was found between number of sessions and adherence to compression rate guidelines during real patient events. Fewer than 30% of providers performed CPR on a patient during the study period. Multicenter studies over longer time periods should be undertaken to overcome the limitation of these rare events.

2.
BMJ Open ; 3(4)2013.
Artigo em Inglês | MEDLINE | ID: mdl-23616435

RESUMO

OBJECTIVE: This article sought to define whether an alternative safety-engineered device (SED) could help prevent needlestick injury (NSI) in healthcare workers (HCWs) who place central venous catheters (CVCs). DESIGN: The study involved three phases: (1) A retrospective analysis of deidentified occupational health records from our tertiary care urban US hospital to clearly identify NSI risk and rates to an HCW during invasive catheter placement; (2) 95 residents were surveyed regarding their knowledge and experience with NSIs and SEDs; (3) A random sample of six residents participated in a focus group session discussing barriers to the use of SED. SETTING: A single urban US tertiary care teaching hospital. PARTICIPANTS: A retrospective analysis of NSI to HCWs in a tertiary care urban US hospital was conducted over a 4-year period (July 2007-June 2011). Ninety-five residents from specialties that often place CVC during training (surgery, surgical subspecialties, internal medicine, anaesthesia and emergency medicine) were surveyed regarding their experience with NSIs and SEDs. A random sample of six residents participated in a focus group session discussing barriers to the use of SED. RESULTS: 314 NSIs were identified via occupational health records. 16% (21 of 131) of NSIs occurring in residents and fellows occurred during the securement of an invasive catheter such as a CVC. If an SED device had been used, the 5.25 NSIs/year could have been avoided. Each NSI occurring in an HCW incurred at least $2723 in charges. Thus, utilisation of the SED could have saved a minimum of $57 183 over the 4-year period. CONCLUSIONS: SEDs are currently available and can be used as an alternative to sharps. If safety and efficacy can be demonstrated, then implementation of such devices can significantly reduce the number of NSIs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA