Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nucl Med Biol ; 39(5): 697-701, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22300960

RESUMO

INTRODUCTION: Thymidylate synthase and folate receptors are well-developed targets of cancer therapy. Discovery of a simple and fast method for the conversion of 11CH3Ito[11C]-formaldehyde (11CH2O) encouraged us to label the co-factor of this enzyme. Preliminary studies conducted on cell lines have demonstrated a preferential uptake of [11-14C]-(R)-N5,N10-methylene-5,6,7,8-tetrahydrofolate (14CH2H4folate) by cancerous cell vs. normal cells from the same organ (Saeed M., Sheff D. and Kohen A. Novel positron emission tomography tracer distinguishes normal from cancerous cells. J Biol Chem 2011;286:33872-33878), pointing out 11CH2H4folate as a positron emission tomography (PET) tracer for cancer imaging. Herein we report the synthesis of 11CH2H4folate, which may serve as a potential PET tracer. METHODS: In a remotely controlled module, methyl iodide (11CH3I) was bubbled into a reaction vial containing trimethylamine N-oxide in N,N-Dimethylformamide (DMF) and heated to 70°C for 2 min. Formaldehyde (11CH2O) formed after the completion of reaction was then mixed with a solution of freshly prepared tetrahydrofolate (H4folate) by using a fast chemoenzymatic approach to accomplish synthesis of 11CH2H4folate. Purification of the product was carried out by loading the crude reaction mixture on a SAX cartridge, washing with water to remove unbound impurities and finally eluting with a saline solution. RESULTS: The synthesis and purification of 11CH2H4folate were completed within 5 min. High-performance liquid chromatography analysis of the product after SAX purification indicates that more than 90% of the radioactivity that was retained on the SAX cartridge was in 11CH2H4folate, with minor (<10%) radioactivity due to unreacted 11CH2O. CONCLUSION: We present a fast (∼5 min) synthesis and purification of 11CH2H4folate as a potential PET tracer. The final product is received in physiologically compatible buffer (100 mM sodium phosphate, pH 7.0 containing 500 mM NaCl) and ready for use in vivo.


Assuntos
Técnicas de Química Sintética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tetra-Hidrofolatos/síntese química , Timidilato Sintase/metabolismo , Radioisótopos de Carbono , Proliferação de Células , Ácido Fólico/química , Formaldeído/química , Cinética , Traçadores Radioativos , Tetra-Hidrofolatos/química
2.
Biomed Signal Process Control ; 3(4): 319-326, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19802329

RESUMO

In this paper, a new adaptive bolus-chasing control scheme is proposed to synchronize the bolus peak in a patient's vascular system and the imaging aperture of a computed tomography (CT) scanner. The proposed control scheme is theoretically evaluated and experimentally tested on a modified Siemens SOMATOM Volume Zoom CT scanner. The first set of experimental results are reported on bolus-chasing CT angiography using realistic bolus dynamics, real-time CT imaging and adaptive table control with physical vasculature phantoms. The data demonstrate that the proposed control approach tracks the bolus propagation well, and clearly outperforms the constant-speed scheme that is the current clinical standard.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA