RESUMO
BACKGROUND: Anxiety is a state of worry caused by the anticipation of external or internal danger. Awareness During Anesthesia (ADA) is an unexpected memory recall during anesthesia. In this study, we aimed to determine the factors that affect preoperative anxiety and observe the incidence of ADA, as well as to determine the anxiety levels of these patients with a history of ADA. METHODS: This study was planned to be prospective, observational, and cross-sectional. Patients in whom septoplasty was planned, who was admitted to the anesthesiology outpatients between March 2018 and September 2018, were ASA I-II, and aged 18-70 years were included in the study. The demographic characteristics of patients were recorded. The State-Trait Anxiety Inventory (STAI) was used to determine anxiety during a preoperative evaluation. The modified Brice awareness score was used simultaneously to determine previous ADA. RESULTS: The anxiety scores of patients who were conscious during anesthesia were higher than other patients. The mean STAI score was 40.85±14.8 in the 799 patients who met the inclusion criteria of this study. When the anxiety scores were compared, the scores were higher in females than in males (p < 0.05). The mean STAI score was found as 40.3±13.8 in patients who dreamed during anesthesia. CONCLUSION: It is important to determine the anxiety levels of patients in the preoperative period to prevent the associated complications. Preoperative anxiety, besides preventing ADA, should be dealt with in a multidisciplinary manner. ADA should be carefully questioned while evaluating previous anesthesia experiences.
Assuntos
Anestesia/métodos , Ansiedade/epidemiologia , Consciência no Peroperatório/epidemiologia , Período Pré-Operatório , Adulto , Estudos Transversais , Sonhos/psicologia , Feminino , Humanos , Consciência no Peroperatório/psicologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores SexuaisRESUMO
Abstract Background: Anxiety is a state of worry caused by the anticipation of external or internal danger. Awareness During Anesthesia (ADA) is an unexpected memory recall during anesthesia. In this study, we aimed to determine the factors that affect preoperative anxiety and observe the incidence of ADA, as well as to determine the anxiety levels of these patients with a history of ADA. Methods: This study was planned to be prospective, observational, and cross-sectional. Patients in whom septoplasty was planned, who was admitted to the anesthesiology outpatients between March 2018 and September 2018, were ASA I-II, and aged 18-70 years were included in the study. The demographic characteristics of patients were recorded. The State-Trait Anxiety Inventory (STAI) was used to determine anxiety during a preoperative evaluation. The modified Brice awareness score was used simultaneously to determine previous ADA. Results: The anxiety scores of patients who were conscious during anesthesia were higher than other patients. The mean STAI score was 40.85 ± 14.8 in the 799 patients who met the inclusion criteria of this study. When the anxiety scores were compared, the scores were higher in females than in males (p < 0.05). The mean STAI score was found as 40.3 ± 13.8 in patients who dreamed during anesthesia. Conclusion: It is important to determine the anxiety levels of patients in the preoperative period to prevent the associated complications. Preoperative anxiety, besides preventing ADA, should be dealt with in a multidisciplinary manner. ADA should be carefully questioned while evaluating previous anesthesia experiences.
Resumo Justificativa: A ansiedade é um estado de preocupação causado pela expectativa de perigo externo ou interno. Consciência durante a anestesia (CDA) é a evocação imprevista da memória de eventos intranestésicos. O objetivo deste estudo foi determinar os fatores que afetam a ansiedade pré-operatória, a incidência de CDA e os níveis de ansiedade nos pacientes com antecedente de CDA. Método: O estudo foi planificado como prospectivo, observacional e transversal. Foram incluídos no estudo pacientes programados para septoplastia eletiva, admitidos ao ambulatório de anestesiologia entre Março de 2018 e Setembro de 2018, com classe funcional ASA I-II e faixa etária entre 18 e 70 anos. As características demográficas dos pacientes foram registradas. O Inventário de Ansiedade Traço-Estado (IDATE) foi utilizado para determinar a ansiedade durante a avaliação pré-operatória. Simultaneamente, o escore de consciência de Brice modificado foi usado para determinar CDA anterior. Resultados: Os escores de ansiedade dos pacientes que apresentaram CDA foram mais elevados do que de outros pacientes. A pontuação média do IDATE foi 40,85±14,8 nos 799 pacientes que obedeceram aos critérios de inclusão do estudo. Quando os escores de ansiedade foram comparados, foram maiores no sexo feminino do que no masculino (p < 0,05). O escore médio do IDATE encontrado foi 40,3±13,8 nos pacientes que relataram sonhos durante a anestesia. Conclusão: É importante determinar no pré-operatório os níveis de ansiedade dos pacientes para evitar as complicações associadas. Ansiedade pré-operatória e a prevenção de CDA devem ser tratadas com abordagem multiprofissional. A CDA deve ser cuidadosamente investigada, avaliando-se as experiências vividas pelo paciente em anestesias pregressas.
Assuntos
Humanos , Masculino , Feminino , Adulto , Ansiedade/epidemiologia , Período Pré-Operatório , Consciência no Peroperatório/epidemiologia , Anestesia/métodos , Fatores Sexuais , Estudos Transversais , Estudos Prospectivos , Sonhos/psicologia , Consciência no Peroperatório/psicologia , Pessoa de Meia-IdadeRESUMO
ABSTRACTPURPOSE: The i-gelTM is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway ClassicTM with respect to the clinical performance.METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation.RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p = 0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6 ± 2.4 s versus 13.1 ± 1.8 s [p = 0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p = 0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24 h after the procedure (p = 0.752).CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
RESUMOJUSTIFICATIVA E OBJETIVO: A i-gel é um dos dispositivos supraglóticos de segunda geração para o manejo das vias aéreas. Nosso estudo foi projetado para comparar a i-gelTM e a máscara laríngea clássica (Laryngeal Mask Airway ClassicTM, LMA-C) em relação ao desempenho clínico.MÉTODOS: Avaliamos os desempenhos de i-gel e LMA-C em 120 pacientes submetidos à cirurgia urológica sob anestesia geral sem relaxante muscular. Comparamos o número de tentativas de inserção bem-sucedidas, o tempo de inserção, a pressão de pico das vias aéreas, a incidência de regurgitação, a visibilidade da glote com o uso de fibra óptica e as complicações no pós-operatório. Os dispositivos supraglóticos de segunda geração foram inseridos pelo mesmo anestesiologista com experiência na aplicação de ambos os dispositivos (> 200 aplicações e taxa de falha na primeira tentativa < 5%). O corante azul de metileno foi usado para detectar regurgitação gástrica.RESULTADOS: Não houve diferença estatística entre os dois grupos em relação ao sucesso da inserção do dispositivo supraglótico de segunda geração (p = 0,951). O tempo de inserção da máscara laríngea no grupo i-gel foi significativamente menor do que no grupo LMA-C (11,6 ± 2,4 segundos vs. 13,1 ± 1,8 segundos, p = 0,001). O escore de visibilidade da glote via fibra óptica do grupo i-gel foi significativamente melhor do que o do grupo LMA-C (p = 0,001). Na visão via fibra ótica, sinais do corante azul de metileno não foram observados em qualquer momento em ambos os grupos. Além disso, não houve diferença entre as respostas dos grupos quando perguntados sobre a presença de dor de garganta 24 horas após o procedimento (p = 0,752).CONCLUSÃO: Ambos os dispositivos apresentaram bom desempenho, com poucas complicações no pós-operatório e sem ocorrência de regurgitação. A máscara laríngea i-gel proporcionou um tempo de inserção mais curto e uma visão via fibra óptica melhor do que a LMA-C.
Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Máscaras Laríngeas/efeitos adversos , Manuseio das Vias Aéreas/instrumentação , Manuseio das Vias Aéreas/efeitos adversos , Tecnologia de Fibra Óptica , Glote , Pessoa de Meia-IdadeRESUMO
PURPOSE: The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance. METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation. RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p=0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6±2.4s versus 13.1±1.8s [p=0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p=0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24h after the procedure (p=0.752). CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
RESUMO
PURPOSE: The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance. METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation. RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p=0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6±2.4s versus 13.1±1.8s [p=0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p=0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24h after the procedure (p=0.752). CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.