Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Appl Clin Med Phys ; : e14347, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576174

RESUMO

PURPOSE: This work investigated the dosimetric accuracy of the intensity-modulated bolus electron conformal therapy (IM-BECT) planning and delivery process using the decimal ElectronRT (eRT) treatment planning system. METHODS: An IM-BECT treatment plan was designed using eRT for a cylindrical, anthropomorphic retromolar trigone phantom. Treatment planning involved specification of beam parameters and design of a variable thickness wax bolus and Passive Radiotherapy Intensity Modulator for Electrons (PRIME) device, which was comprised of 33 tungsten island blocks of discrete diameters from 0.158 to 0.223 cm (Intensity Reduction Factors from 0.937 to 0.875, respectively) inside a 10.1 × 6.7 cm2 copper cutout. For comparison of calculation accuracy, a BECT plan was generated by copying the IM-BECT plan and removing the intensity modulation. For both plans, a 16 MeV electron beam was used with 104.7 cm source-to-surface distance to bolus. In-phantom TLD-100 measurements (N = 47) were compared with both eRT planned dose distributions, which used the pencil beam redefinition algorithm with modifications for passive electron intensity modulation (IM-PBRA). Dose difference and distance to agreement (DTA) metrics were computed for each measurement point. RESULTS: Comparison of measured dose distributions with planned dose distributions yielded dose differences (calculated minus measured) characterized by a mean and standard deviation of -0.36% ± 1.64% for the IM-BECT plan, which was similar to -0.36% ± 1.90% for the BECT plan. All dose measurements were within 5% of the planned dose distribution, with both the BECT and IM-BECT measurement sets having 46/47 (97.8%) points within 3% or within 3 mm of the respective treatment plans. CONCLUSIONS: It was found that the IM-BECT treatment plan generated using eRT was sufficiently accurate for clinical use when compared to TLD measurements in a cylindrical, anthropomorphic phantom, and was similarly accurate to the BECT treatment plan in the same phantom.

2.
Int J Part Ther ; 10(2): 85-93, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38075486

RESUMO

Purpose: Many patients with metastatic cancer live years beyond diagnosis, and there remains a need to improve the therapeutic ratio of metastasis-directed radiation for these patients. This study aimed to assess a process for delivering cost-effective palliative proton therapy to the spine using diagnostic scan-based planning (DSBP) and prefabricated treatment delivery devices. Materials and Methods: We designed and characterized a reusable proton aperture system that adjusts to multiple lengths for spine treatment. Next, we retrospectively identified 10 patients scan treated with thoracic proton therapy who also had a diagnostic computed tomography within 4 months of simulation. We contoured a T6-T9 target volume on both the diagnostic scans (DS) and simulation scans (SS). Using the aperture system, we generated proton plans on the DS using a posterior-anterior beam with no custom range compensator to treat T6-T9 to 8 Gy × 1. Plans were transferred to the SS to compare coverage and normal tissue doses, followed by robustness analysis. Finally, we compared normal tissue doses and costs between proton and photon plans. Results were compared using the Wilcoxon signed-rank test. Results: Median D95% on the DS plans was 101% (range, 100%-102%) of the prescription dose. Median Dmax was 107% (range, 105%-108%). When transferred to SS, coverage and hot spots remained acceptable for all cases. Heart and esophagus doses did not vary between the DS and SS proton plans (P >.2). Robustness analysis with 5 mm X/Y/Z shifts showed acceptable coverage (D95% > 98%) for all cases. Compared with the proton plans, the mean heart dose was higher for both anterior-posterior/posterior-anterior and volumetric modulated arc therapy plans (P < .01). Cost for proton DSBP was comparable to more commonly used photon regimens. Conclusion: Proton DSBP is technically feasible and robust, with superior sparing of the heart compared with photons. Eliminating simulation and custom devices increases the value of this approach in carefully selected patients.

3.
Med Phys ; 50(10): 6569-6579, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37696040

RESUMO

PURPOSE: The increased normal tissue tolerance for FLASH radiotherapy (FLASH-RT), as compared to conventional radiotherapy, was first observed in ultra-high dose rate electron beams. Initial clinical trials in companion animals have revealed a high risk of developing osteoradionecrosis following high-dose single-fraction electron FLASH-RT, which may be related to inhomogeneities in the dose distribution. In the current study, we aim to evaluate the possibilities of intensity-modulated electron FLASH-RT in a clinical setting to ensure a homogeneous dose distribution in future veterinary and human clinical trials. METHODS: Our beam model in the treatment planning system electronRT (.decimal, LLC, Sanford, FL, USA) was based on a 10-MeV electron beam from a clinical linear accelerator used to treat veterinary patients with FLASH-RT in a clinical setting. In electronRT, the beam can be intensity-modulated using tungsten island blocks in the electron block cutout, and range-modulated using a customized bolus with variable thickness. Modulations were first validated in a heterogeneous phantom by comparing measured and calculated dose distributions. To evaluate the impact of intensity modulation in superficial single-fraction FLASH-RT, a treatment planning study was conducted, including eight canine cancer patient cases with simulated tumors in the head-and-neck region. For each case, treatment plans with and without intensity modulation were created for a uniform bolus and a range-modulating bolus. Treatment plans were evaluated using a target dose homogeneity index (HI), a conformity index (CI), the near-maximum dose outside the target ( D 2 % , Body - PTV ${D_{2{\mathrm{\% }},{\mathrm{\ Body}} - {\mathrm{PTV}}}}$ ), and the near-minimum dose to the target ( D 98 % ${D_{98\% }}$ ). RESULTS: By adding intensity modulation to plans with a uniform bolus, the HI could be improved (p = 0.017). The combination of a range-modulating bolus and intensity modulation provided a further significant improvement of the HI as compared to using intensity modulation in combination with a uniform bolus (p = 0.036). The range-modulating bolus also improved the CI compared to using a uniform bolus, both with an open beam (p = 0.046) and with intensity modulation (p = 0.018), as well as increased the D 98 % ${D_{98\% }}$ (p = 0.036 with open beam and p = 0.05 with intensity modulation) and reduced the median D 2 % , Body - PTV ${D_{2\% ,{\mathrm{\ Body}} - {\mathrm{PTV}}}}$ (not significant). CONCLUSIONS: By using intensity-modulated electron FLASH-RT in combination with range-modulating bolus, the target dose homogeneity and conformity in canine patients with simulated tumors in complex areas in the head-and-neck region could be improved. By utilizing this technique, we hope to decrease the dose outside the target volume and avoid hot spots in future clinical electron FLASH-RT studies, thereby reducing the risk of radiation-induced toxicity.


Assuntos
Neoplasias , Lesões por Radiação , Radioterapia de Intensidade Modulada , Humanos , Animais , Cães , Elétrons , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos
4.
Med Phys ; 50(11): 7263-7280, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37370239

RESUMO

BACKGROUND: The Dynamic Collimation System (DCS) has been shown to produce superior treatment plans to uncollimated pencil beam scanning (PBS) proton therapy using an in-house treatment planning system (TPS) designed for research. Clinical implementation of the DCS requires the development and benchmarking of a rigorous dose calculation algorithm that accounts for pencil beam trimming, performs monitor unit calculations to produce deliverable plans at all beam energies, and is ideally implemented with a commercially available TPS. PURPOSE: To present an analytical Pencil bEam TRimming Algorithm (PETRA) for the DCS, with and without its range shifter, implemented in the Astroid TPS (.decimal, Sanford, Florida, USA). MATERIALS: PETRA was derived by generalizing an existing pencil beam dose calculation model to account for the DCS-specific effects of lateral penumbra blurring due to the nickel trimmers in two different planes, integral depth dose variation due to the trimming process, and the presence and absence of the range shifter. Tuning parameters were introduced to enable agreement between PETRA and a measurement-validated Dynamic Collimation Monte Carlo (DCMC) model of the Miami Cancer Institute's IBA Proteus Plus system equipped with the DCS. Trimmer position, spot position, beam energy, and the presence or absence of a range shifter were all used as variables for the characterization of the model. The model was calibrated for pencil beam monitor unit calculations using procedures specified by International Atomic Energy Agency Technical Report Series 398 (IAEA TRS-398). RESULTS: The integral depth dose curves (IDDs) for energies between 70 MeV and 160 MeV among all simulated trimmer combinations, with and without the ranger shifter, agreed between PETRA and DCMC at the 1%/1 mm 1-D gamma criteria for 99.99% of points. For lateral dose profiles, the median 2-D gamma pass rate for all profiles at 1.5%/1.5 mm was 99.99% at the water phantom surface, plateau, and Bragg peak depths without the range shifter and at the surface and Bragg peak depths with the range shifter. The minimum 1.5%/1.5 mm gamma pass rates for the 2-D profiles at the water phantom surface without and with the range shifter were 98.02% and 97.91%, respectively, and, at the Bragg peak, the minimum pass rates were 97.80% and 97.5%, respectively. CONCLUSION: The PETRA model for DCS dose calculations was successfully defined and benchmarked for use in a commercially available TPS.


Assuntos
Terapia com Prótons , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Algoritmos , Imagens de Fantasmas , Método de Monte Carlo , Água
5.
J Appl Clin Med Phys ; 24(7): e13943, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36855930

RESUMO

PURPOSE: This work developed an x-ray-based method for performing factory quality assurance (QA) of Passive Radiotherapy Intensity Modulators for Electrons (PRIME) device fabrication. This method measures errors in position, diameter, and orientation of cylindrical island blocks on a hexagonal grid that comprises PRIME devices and the impact of such errors on the underlying intensity distribution. METHODS: X-ray images were acquired of six PRIME devices, which modeled three error cases (small random, large random, and systematic errors) for two island block diameters (0.158 and 0.352 cm). Island blocks in each device, 0.6 cm long tungsten cylinders of constant diameter, were spaced 0.6 cm on a hexagonal grid over approximately 8 cm square. Using a 50 kVp x-ray image, each island block projected a racetrack, whose perimeter was fit to a function that allowed determination of its position, diameter, and angular orientation (θ, ϕ). These measured parameters were input into a pencil beam algorithm (PBA) dose calculation performed in water (16 MeV, SSD = 103 cm) for each device. PBA calculated intensity distributions using measured and planned (exact) island block parameters were compared. RESULTS: Θ distributions for the 0.158 and 0.352 cm devices were nearly identical for each error case, with θ values for most island blocks being within 3.2°, 8.5°, and 7.5° for the small random, large random, and systematic error PRIME devices, respectively. Corresponding intensity differences between using measured and planned island block parameters were within 1.0% and 2.8% (small random), 2.2% and 4.8% (large random), and 3.2% and 6.7% (systematic) for the 0.158 and 0.352 cm devices, respectively. CONCLUSION: This approach provides a viable and economical method for factory QA of fabricated PRIME devices by determining errors in their planned intensity distribution from which their quality can be assessed prior to releasing to the customer.


Assuntos
Elétrons , Radioterapia de Intensidade Modulada , Humanos , Raios X , Radiografia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Imagens de Fantasmas , Radioterapia de Intensidade Modulada/métodos
6.
J Appl Clin Med Phys ; 24(2): e13889, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36610042

RESUMO

PURPOSE: Passive Radiotherapy Intensity Modulators for Electrons (PRIME) devices are comprised of cylindrical tungsten island blocks imbedded in a machinable foam slab within the patient's cutout. Intensity-modulated bolus electron conformal therapy (IM-BECT) uses PRIME devices to reduce dose heterogeneity caused by the irregular bolus surface. Heretofore, IM-BECT dose calculations used the pencil beam redefinition algorithm (PBRA) assuming perfect collimation. This study investigates modeling electron scatter into and out the sides of island blocks. METHODS: Dose distributions were measured in a water phantom at 7, 13, and 20 MeV for devices having nominal intensity reduction factors of 1.000 (foam only), 0.937, 0.812, and 0.688, corresponding to nominal island block diameters (dnom ) of 0.158, 0.273, and 0.352 cm, respectively. Pencil beam theory derived an effective diameter (dIS ) to account for in-scattered electrons as a function of dnom and beam energy (Ep,0 ). However, for out-scattered electrons, an effective diameter (dmod ) was estimated by best fitting measured data. RESULTS: In the modulated region (under island blocks, depth < R90 ), modified PBRA-calculated dose distributions showed 2%/2 mm passing rates for dnom  = 0.158, 0.273, and 0.352 cm of (100%, 100%, 100%) at 7 MeV, (100%, 100%, 93.5%) at 13 MeV, and (99.8%, 85.4%, and 71.5%) at 20 MeV. The largest dose differences (≤ 6%) occurred at the highest energy (20 MeV), largest dnom , shallowest depths (≤ 2 cm), and on central axis. CONCLUSIONS: An equation for modeling island block scatter, dmod (dnom , Ep,0 ), has been developed for use in the PBRA, insignificantly impacting calculation time. Although inaccuracy sometimes exceeded our 2%/2 mm criteria, it could be clinically acceptable, as superficial dose differences often fall inside the bolus. Also, patient PRIME devices are expected to have fewer large diameter island blocks than did test devices. Inaccuracies are attributed to out-scattered electrons having energy spectra different than the primary beams.


Assuntos
Elétrons , Radioterapia Conformacional , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Imagens de Fantasmas
7.
Int J Part Ther ; 9(1): 54-63, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774494

RESUMO

Purpose: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. Materials and Methods: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning systems) and three boundary-contoured (concentric contours, hybrid, and optimized) techniques. Treatment plans were created for two different target volumes, one spherical and one conical. An optimal set of planning parameters was defined for all treatment plans and the impact of spot placement techniques on the plan quality was evaluated in terms of lateral/distal dose falloff, normal tissue sparing, conformity and homogeneity of dose distributions, as well as total number of spots used. Results: The results of this work highlight that for grid-based spot placement techniques, the dose conformity is dependent on target cross-sectional shape perpendicular to beam direction, which changes for each energy layer. This variable conformity problem is mitigated by using boundary contoured spot placement techniques. However, in the case of concentric contours, the conformity is improved but at the cost of decreased homogeneity inside the target. Hybrid and optimized spot placement techniques, which use contoured spots at the boundary and gridlike interior spot patterns, provide more uniform dose distributions inside the target volume while maintaining the improved dose conformity. The optimized spot placement technique improved target coverage, homogeneity of dose, and minimal number of spots. The dependence of these results on spot size is also presented for both target shapes. Conclusion: This work illustrates that boundary-contoured spot placement techniques offer marked improvement in dosimetry metrics when compared to commercially available grid-based techniques for a range of proton scanned beam spot sizes.

8.
J Appl Clin Med Phys ; 22(10): 8-21, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34558774

RESUMO

PURPOSE: Bolus electron conformal therapy (BECT) is a clinically useful, well-documented, and available technology. The addition of intensity modulation (IM) to BECT reduces volumes of high dose and dose spread in the planning target volume (PTV). This paper demonstrates new techniques for a process that should be suitable for planning and delivering IM-BECT using passive radiotherapy intensity modulation for electrons (PRIME) devices. METHODS: The IM-BECT planning and delivery process is an addition to the BECT process that includes intensity modulator design, fabrication, and quality assurance. The intensity modulator (PRIME device) is a hexagonal matrix of small island blocks (tungsten pins of varying diameter) placed inside the patient beam-defining collimator (cutout). Its design process determines a desirable intensity-modulated electron beam during the planning process, then determines the island block configuration to deliver that intensity distribution (segmentation). The intensity modulator is fabricated and quality assurance performed at the factory (.decimal, LLC, Sanford, FL). Clinical quality assurance consists of measuring a fluence distribution in a plane perpendicular to the beam in a water or water-equivalent phantom. This IM-BECT process is described and demonstrated for two sites, postmastectomy chest wall and temple. Dose plans, intensity distributions, fabricated intensity modulators, and quality assurance results are presented. RESULTS: IM-BECT plans showed improved D90-10 over BECT plans, 6.4% versus 7.3% and 8.4% versus 11.0% for the postmastectomy chest wall and temple, respectively. Their intensity modulators utilized 61 (single diameter) and 246 (five diameters) tungsten pins, respectively. Dose comparisons for clinical quality assurance showed that for doses greater than 10%, measured agreed with calculated dose within 3% or 0.3 cm distance-to-agreement (DTA) for 99.9% and 100% of points, respectively. CONCLUSION: These results demonstrated the feasibility of translating IM-BECT to the clinic using the techniques presented for treatment planning, intensity modulator design and fabrication, and quality assurance processes.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Elétrons , Feminino , Humanos , Mastectomia , Imagens de Fantasmas
9.
Phys Med Biol ; 64(23): 235016, 2019 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-31618722

RESUMO

Maintaining a sharp lateral dose falloff in pencil beam scanning (PBS) proton therapy is crucial for sparing organs at risk (OARs), especially when they are in close proximity to the target volume. The most common approach to improve lateral dose falloff is through the use of physical beam shaping devices, such as brass apertures or collimator based systems. A recently proposed approach focuses on proton beam spot placements, moving away from traditional grid-based placements to concentric-contours based schemes. This improves lateral dose falloff in two ways: (1) by better conforming all spots to the tumor boundary and (2) allowing for 'edge enhancement', where boundary spots deliver higher fluence than more central spots, thereby creating a steeper lateral dose falloff. However, these benefits come at the expense of maintaining uniformity of spot distribution inside the target volume. In this work we have developed a new optimized spot placement scheme that provides robust spot distributions inside the target. This approach achieves the boundary conformity of a concentric-contours based approach and uses a fast-iterative method to distribute the interior spots in a highly uniform fashion in an attempt to improve both the lateral dose falloff and uniformity. Furthermore, we quantified the impact of this new approach through direct comparison with grid, contour, and hybrid spot placements schemes, showing improvements for this new approach. The results were validated in homogeneous medium for two different target shapes having concave and convex geometry.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Neoplasias/radioterapia , Órgãos em Risco , Dosagem Radioterapêutica
10.
J Appl Clin Med Phys ; 18(6): 10-19, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28875590

RESUMO

This work introduces a new technology for electron intensity modulation, which uses small area island blocks within the collimating aperture and small area island apertures in the collimating insert. Due to multiple Coulomb scattering, electrons contribute dose under island blocks and lateral to island apertures. By selecting appropriate lateral positions and diameters of a set of island blocks and island apertures, for example, a hexagonal grid with variable diameter circular island blocks, intensity modulated beams can be produced for appropriate air gaps between the intensity modulator (position of collimating insert) and the patient. Such a passive radiotherapy intensity modulator for electrons (PRIME) is analogous to using physical attenuators (metal compensators) for intensity modulated x-ray therapy (IMXT). For hexagonal spacing, the relationship between block (aperture) separation (r) and diameter (d) and the local intensity reduction factor (IRF) is discussed. The PRIME principle is illustrated using pencil beam calculations for select beam geometries in water with half beams modulated by 70%-95% and for one head and neck field of a patient treated with bolus electron conformal therapy. Proof of principle is further illustrated by showing agreement between measurement and calculation for a prototype PRIME. Potential utilization of PRIME for bolus electron conformal therapy, segmented-field electron conformal therapy, modulated electron radiation therapy, and variable surface geometries is discussed. Further research and development of technology for the various applications is discussed. In summary, this paper introduces a practical, new technology for electron intensity modulation in the clinic, demonstrates proof of principle, discusses potential clinical applications, and suggests areas of further research and development.


Assuntos
Elétrons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Humanos
11.
Med Dosim ; 40(1): 37-43, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25263491

RESUMO

In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample. The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from -4.7 to +3.0 and the average absolute performance results ranged from -6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design.


Assuntos
Neoplasias/radioterapia , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Radioterapia de Alta Energia/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Espalhamento de Radiação , Sensibilidade e Especificidade , Resultado do Tratamento
12.
Stud Health Technol Inform ; 163: 567-73, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21335858

RESUMO

This paper reports on the usage of physics-based 3D volumetric lung dynamic models for visualizing and monitoring the radiation dose deposited on the lung of a human subject during lung radiotherapy. The dynamic model of each subject is computed from a 4D Computed Tomography (4DCT) imaging acquired before the treatment. The 3D lung deformation and the radiation dose deposited are computed using Graphics Processing Units (GPU). Additionally, using the dynamic lung model, the airflow inside the lungs during the treatment is also investigated. Results show the radiation dose deposited on the lung tumor as well as the surrounding tissues, the combination of which is patient-specific and varies from one treatment fraction to another.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Radioterapia Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador , Sistemas Computacionais , Humanos , Tamanho do Órgão , Radioterapia Conformacional/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...