Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Front Cardiovasc Med ; 10: 1103751, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025678

RESUMO

The total kinetic energy (KE) of blood can be decomposed into mean KE (MKE) and turbulent KE (TKE), which are associated with the phase-averaged fluid velocity field and the instantaneous velocity fluctuations, respectively. The aim of this study was to explore the effects of pharmacologically induced stress on MKE and TKE in the left ventricle (LV) in a cohort of healthy volunteers. 4D Flow MRI data were acquired in eleven subjects at rest and after dobutamine infusion, at a heart rate that was ∼60% higher than the one in rest conditions. MKE and TKE were computed as volume integrals over the whole LV and as data mapped to functional LV flow components, i.e., direct flow, retained inflow, delayed ejection flow and residual volume. Diastolic MKE and TKE increased under stress, in particular at peak early filling and peak atrial contraction. Augmented LV inotropy and cardiac frequency also caused an increase in direct flow and retained inflow MKE and TKE. However, the TKE/KE ratio remained comparable between rest and stress conditions, suggesting that LV intracavitary fluid dynamics can adapt to stress conditions without altering the TKE to KE balance of the normal left ventricle at rest.

2.
Anal Chem ; 93(32): 11215-11224, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34355890

RESUMO

The accurate processing of complex liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) data from biological samples is a major challenge for metabolomics, proteomics, and related approaches. Here, we present the pipelines and systems for threshold-avoiding quantification (PASTAQ) LC-MS/MS preprocessing toolset, which allows highly accurate quantification of data-dependent acquisition LC-MS/MS datasets. PASTAQ performs compound quantification using single-stage (MS1) data and implements novel algorithms for high-performance and accurate quantification, retention time alignment, feature detection, and linking annotations from multiple identification engines. PASTAQ offers straightforward parameterization and automatic generation of quality control plots for data and preprocessing assessment. This design results in smaller variance when analyzing replicates of proteomes mixed with known ratios and allows the detection of peptides over a larger dynamic concentration range compared to widely used proteomics preprocessing tools. The performance of the pipeline is also demonstrated in a biological human serum dataset for the identification of gender-related proteins.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Algoritmos , Cromatografia Líquida , Humanos , Peptídeos , Proteoma
3.
Clin Transl Med ; 11(7): e451, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34323402

RESUMO

The MM500 meta-study aims to establish a knowledge basis of the tumor proteome to serve as a complement to genome and transcriptome studies. Somatic mutations and their effect on the transcriptome have been extensively characterized in melanoma. However, the effects of these genetic changes on the proteomic landscape and the impact on cellular processes in melanoma remain poorly understood. In this study, the quantitative mass-spectrometry-based proteomic analysis is interfaced with pathological tumor characterization, and associated with clinical data. The melanoma proteome landscape, obtained by the analysis of 505 well-annotated melanoma tumor samples, is defined based on almost 16 000 proteins, including mutated proteoforms of driver genes. More than 50 million MS/MS spectra were analyzed, resulting in approximately 13,6 million peptide spectrum matches (PSMs). Altogether 13 176 protein-coding genes, represented by 366 172 peptides, in addition to 52 000 phosphorylation sites, and 4 400 acetylation sites were successfully annotated. This data covers 65% and 74% of the predicted and identified human proteome, respectively. A high degree of correlation (Pearson, up to 0.54) with the melanoma transcriptome of the TCGA repository, with an overlap of 12 751 gene products, was found. Mapping of the expressed proteins with quantitation, spatiotemporal localization, mutations, splice isoforms, and PTM variants was proven not to be predicted by genome sequencing alone. The melanoma tumor molecular map was complemented by analysis of blood protein expression, including data on proteins regulated after immunotherapy. By adding these key proteomic pillars, the MM500 study expands the knowledge on melanoma disease.


Assuntos
Melanoma/patologia , Proteoma/metabolismo , Proteômica/métodos , Transcriptoma , Antineoplásicos/uso terapêutico , Proteínas Sanguíneas/metabolismo , Linhagem Celular , Cromatografia Líquida de Alta Pressão , Bases de Dados Factuais , Humanos , Melanoma/tratamento farmacológico , Melanoma/metabolismo , Mutação , Processamento de Proteína Pós-Traducional/genética , Proteínas Proto-Oncogênicas B-raf/genética , Proteínas Proto-Oncogênicas B-raf/metabolismo , Espectrometria de Massas em Tandem
4.
Clin Transl Med ; 11(7): e473, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34323403

RESUMO

The MM500 study is an initiative to map the protein levels in malignant melanoma tumor samples, focused on in-depth histopathology coupled to proteome characterization. The protein levels and localization were determined for a broad spectrum of diverse, surgically isolated melanoma tumors originating from multiple body locations. More than 15,500 proteoforms were identified by mass spectrometry, from which chromosomal and subcellular localization was annotated within both primary and metastatic melanoma. The data generated by global proteomic experiments covered 72% of the proteins identified in the recently reported high stringency blueprint of the human proteome. This study contributes to the NIH Cancer Moonshot initiative combining detailed histopathological presentation with the molecular characterization for 505 melanoma tumor samples, localized in 26 organs from 232 patients.


Assuntos
Melanoma/patologia , Proteoma/análise , Proteômica/métodos , Neoplasias Cutâneas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Linhagem Celular Tumoral , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Masculino , Melanoma/metabolismo , Pessoa de Meia-Idade , Neoplasias Cutâneas/metabolismo , Espectrometria de Massas em Tandem , Adulto Jovem , Melanoma Maligno Cutâneo
5.
Anal Chem ; 92(24): 16138-16148, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33317272

RESUMO

Mass spectrometry imaging (MSI) is a technique that provides comprehensive molecular information with high spatial resolution from tissue. Today, there is a strong push toward sharing data sets through public repositories in many research fields where MSI is commonly applied; yet, there is no standardized protocol for analyzing these data sets in a reproducible manner. Shifts in the mass-to-charge ratio (m/z) of molecular peaks present a major obstacle that can make it impossible to distinguish one compound from another. Here, we present a label-free m/z alignment approach that is compatible with multiple instrument types and makes no assumptions on the sample's molecular composition. Our approach, MSIWarp (https://github.com/horvatovichlab/MSIWarp), finds an m/z recalibration function by maximizing a similarity score that considers both the intensity and m/z position of peaks matched between two spectra. MSIWarp requires only centroid spectra to find the recalibration function and is thereby readily applicable to almost any MSI data set. To deal with particularly misaligned or peak-sparse spectra, we provide an option to detect and exclude spurious peak matches with a tailored random sample consensus (RANSAC) procedure. We evaluate our approach with four publicly available data sets from both time-of-flight (TOF) and Orbitrap instruments and demonstrate up to 88% improvement in m/z alignment.

6.
Cell Biol Toxicol ; 36(3): 261-272, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31599373

RESUMO

In the advanced stages, malignant melanoma (MM) has a very poor prognosis. Due to tremendous efforts in cancer research over the last 10 years, and the introduction of novel therapies such as targeted therapies and immunomodulators, the rather dark horizon of the median survival has dramatically changed from under 1 year to several years. With the advent of proteomics, deep-mining studies can reach low-abundant expression levels. The complexity of the proteome, however, still surpasses the dynamic range capabilities of current analytical techniques. Consequently, many predicted protein products with potential biological functions have not yet been verified in experimental proteomic data. This category of 'missing proteins' (MP) is comprised of all proteins that have been predicted but are currently unverified. As part of the initiative launched in 2016 in the USA, the European Cancer Moonshot Center has performed numerous deep proteomics analyses on samples from MM patients. In this study, nine MPs were clearly identified by mass spectrometry in MM metastases. Some MPs significantly correlated with proteins that possess identical PFAM structural domains; and other MPs were significantly associated with cancer-related proteins. This is the first study to our knowledge, where unknown and novel proteins have been annotated in metastatic melanoma tumour tissue.


Assuntos
Melanoma/genética , Metástase Neoplásica/genética , Proteômica/métodos , Adulto , Biomarcadores Tumorais/genética , Feminino , Genoma Humano/genética , Humanos , Masculino , Pessoa de Meia-Idade , Anotação de Sequência Molecular/métodos , Anotação de Sequência Molecular/tendências , Prognóstico , Proteoma/genética , Proteoma/metabolismo , Neoplasias Cutâneas/genética , Melanoma Maligno Cutâneo
7.
Cancers (Basel) ; 11(12)2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31835364

RESUMO

In comparison to other human cancer types, malignant melanoma exhibits the greatest amount of heterogeneity. After DNA-based detection of the BRAF V600E mutation in melanoma patients, targeted inhibitor treatment is the current recommendation. This approach, however, does not take the abundance of the therapeutic target, i.e., the B-raf V600E protein, into consideration. As shown by immunohistochemistry, the protein expression profiles of metastatic melanomas clearly reveal the existence of inter- and intra-tumor variability. Nevertheless, the technique is only semi-quantitative. To quantitate the mutant protein there is a fundamental need for more precise techniques that are aimed at defining the currently non-existent link between the levels of the target protein and subsequent drug efficacy. Using cutting-edge mass spectrometry combined with DNA and mRNA sequencing, the mutated B-raf protein within metastatic tumors was quantitated for the first time. B-raf V600E protein analysis revealed a subjacent layer of heterogeneity for mutation-positive metastatic melanomas. These were characterized into two distinct groups with different tumor morphologies, protein profiles and patient clinical outcomes. This study provides evidence that a higher level of expression in the mutated protein is associated with a more aggressive tumor progression. Our study design, comprised of surgical isolation of tumors, histopathological characterization, tissue biobanking, and protein analysis, may enable the eventual delineation of patient responders/non-responders and subsequent therapy for malignant melanoma.

8.
Anal Chem ; 91(18): 11888-11896, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31403280

RESUMO

Mass spectrometry imaging (MSI) has the potential to reveal the localization of thousands of biomolecules such as metabolites and lipids in tissue sections. The increase in both mass and spatial resolution of today's instruments brings on considerable challenges in terms of data processing; accurately extracting meaningful signals from the large data sets generated by MSI without losing information that could be clinically relevant is one of the most fundamental tasks of analysis software. Ion images of the biomolecules are generated by visualizing their intensities in 2-D space using mass spectra collected across the tissue section. The intensities are often calculated by summing each compound's signal between predefined sets of borders (bins) in the m/z dimension. This approach, however, can result in mixed signals from different compounds in the same bin or splitting the signal from one compound between two adjacent bins, leading to low quality ion images. To remedy this problem, we propose a novel data processing approach. Our approach consists of a sensitive peak detection method able to discover both faint and localized signals by utilizing clusterwise kernel density estimates (KDEs) of peak distributions. We show that our method can recall more ground-truth molecules, molecule fragments, and isotopes than existing methods based on binning. Furthermore, it automatically detects previously reported molecular ions of lipids, including those close in m/z, in an experimental data set.

9.
Sci Rep ; 9(1): 5154, 2019 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-30914758

RESUMO

Metastatic melanoma is one of the most common deadly cancers, and robust biomarkers are still needed, e.g. to predict survival and treatment efficiency. Here, protein expression analysis of one hundred eleven melanoma lymph node metastases using high resolution mass spectrometry is coupled with in-depth histopathology analysis, clinical data and genomics profiles. This broad view of protein expression allowed to identify novel candidate protein markers that improved prediction of survival in melanoma patients. Some of the prognostic proteins have not been reported in the context of melanoma before, and few of them exhibit unexpected relationship to survival, which likely reflects the limitations of current knowledge on melanoma and shows the potential of proteomics in clinical cancer research.


Assuntos
Genômica , Melanoma/genética , Melanoma/patologia , Proteômica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Estimativa de Kaplan-Meier , Análise dos Mínimos Quadrados , Masculino , Melanoma/diagnóstico , Pessoa de Meia-Idade , Análise de Componente Principal , Prognóstico , Modelos de Riscos Proporcionais , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
10.
Cell Biol Toxicol ; 35(4): 293-332, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30900145

RESUMO

Melanoma of the skin is the sixth most common type of cancer in Europe and accounts for 3.4% of all diagnosed cancers. More alarming is the degree of recurrence that occurs with approximately 20% of patients lethally relapsing following treatment. Malignant melanoma is a highly aggressive skin cancer and metastases rapidly extend to the regional lymph nodes (stage 3) and to distal organs (stage 4). Targeted oncotherapy is one of the standard treatment for progressive stage 4 melanoma, and BRAF inhibitors (e.g. vemurafenib, dabrafenib) combined with MEK inhibitor (e.g. trametinib) can effectively counter BRAFV600E-mutated melanomas. Compared to conventional chemotherapy, targeted BRAFV600E inhibition achieves a significantly higher response rate. After a period of cancer control, however, most responsive patients develop resistance to the therapy and lethal progression. The many underlying factors potentially causing resistance to BRAF inhibitors have been extensively studied. Nevertheless, the remaining unsolved clinical questions necessitate alternative research approaches to address the molecular mechanisms underlying metastatic and treatment-resistant melanoma. In broader terms, proteomics can address clinical questions far beyond the reach of genomics, by measuring, i.e. the relative abundance of protein products, post-translational modifications (PTMs), protein localisation, turnover, protein interactions and protein function. More specifically, proteomic analysis of body fluids and tissues in a given medical and clinical setting can aid in the identification of cancer biomarkers and novel therapeutic targets. Achieving this goal requires the development of a robust and reproducible clinical proteomic platform that encompasses automated biobanking of patient samples, tissue sectioning and histological examination, efficient protein extraction, enzymatic digestion, mass spectrometry-based quantitative protein analysis by label-free or labelling technologies and/or enrichment of peptides with specific PTMs. By combining data from, e.g. phosphoproteomics and acetylomics, the protein expression profiles of different melanoma stages can provide a solid framework for understanding the biology and progression of the disease. When complemented by proteogenomics, customised protein sequence databases generated from patient-specific genomic and transcriptomic data aid in interpreting clinical proteomic biomarker data to provide a deeper and more comprehensive molecular characterisation of cellular functions underlying disease progression. In parallel to a streamlined, patient-centric, clinical proteomic pipeline, mass spectrometry-based imaging can aid in interrogating the spatial distribution of drugs and drug metabolites within tissues at single-cell resolution. These developments are an important advancement in studying drug action and efficacy in vivo and will aid in the development of more effective and safer strategies for the treatment of melanoma. A collaborative effort of gargantuan proportions between academia and healthcare professionals has led to the initiation, establishment and development of a cutting-edge cancer research centre with a specialisation in melanoma and lung cancer. The primary research focus of the European Cancer Moonshot Lund Center is to understand the impact that drugs have on cancer at an individualised and personalised level. Simultaneously, the centre increases awareness of the relentless battle against cancer and attracts global interest in the exceptional research performed at the centre.


Assuntos
Melanoma/patologia , Melanoma/terapia , Pesquisa Translacional Biomédica/métodos , Bancos de Espécimes Biológicos/tendências , Biomarcadores Tumorais , Resistencia a Medicamentos Antineoplásicos/genética , Resistencia a Medicamentos Antineoplásicos/fisiologia , Humanos , Imidazóis/farmacologia , Melanoma/metabolismo , Estadiamento de Neoplasias , Oximas/farmacologia , Inibidores de Proteínas Quinases/farmacologia , Proteômica/métodos , Piridonas/farmacologia , Pirimidinonas/farmacologia , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/terapia , Melanoma Maligno Cutâneo
11.
J Cardiovasc Magn Reson ; 20(1): 15, 2018 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-29499706

RESUMO

BACKGROUND: Quantification and visualisation of left ventricular (LV) blood flow is afforded by three-dimensional, time resolved phase contrast cardiovascular magnetic resonance (CMR 4D flow). However, few data exist upon the repeatability and variability of these parameters in a healthy population. We aimed to assess the repeatability and variability over time of LV 4D CMR flow measurements. METHODS: Forty five controls underwent CMR 4D flow data acquisition. Of these, 10 underwent a second scan within the same visit (scan-rescan), 25 returned for a second visit (interval scan; median interval 52 days, IQR 28-57 days). The LV-end diastolic volume (EDV) was divided into four flow components: 1) Direct flow: inflow that passes directly to ejection; 2) Retained inflow: inflow that enters and resides within the LV; 3) Delayed ejection flow: starts within the LV and is ejected and 4) Residual volume: blood that resides within the LV for > 2 cardiac cycles. Each flow components' volume was related to the EDV (volume-ratio). The kinetic energy at end-diastole (ED) was measured and divided by the components' volume. RESULTS: The dominant flow component in all 45 controls was the direct flow (volume ratio 38 ± 4%) followed by the residual volume (30 ± 4%), then delayed ejection flow (16 ± 3%) and retained inflow (16 ± 4%). The kinetic energy at ED for each component was direct flow (7.8 ± 3.0 microJ/ml), retained inflow (4.1 ± 2.0 microJ/ml), delayed ejection flow (6.3 ± 2.3 microJ/ml) and the residual volume (1.2 ± 0.5 microJ/ml). The coefficients of variation for the scan-rescan ranged from 2.5%-9.2% for the flow components' volume ratio and between 13.5%-17.7% for the kinetic energy. The interval scan results showed higher coefficients of variation with values from 6.2-16.1% for the flow components' volume ratio and 16.9-29.0% for the kinetic energy of the flow components. CONCLUSION: LV flow components' volume and their associated kinetic energy values are repeatable and stable within a population over time. However, the variability of these measurements in individuals over time is greater than can be attributed to sources of error in the data acquisition and analysis, suggesting that additional physiological factors may influence LV flow measurements.


Assuntos
Circulação Coronária , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Função Ventricular Esquerda , Adulto Jovem
12.
Magn Reson Imaging ; 47: 83-88, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29217489

RESUMO

4D Flow MRI has been used to quantify normal and deranged left ventricular blood flow characteristics on the basis of functionally distinct flow components. However, the application of this technique to the atria is challenging due to the presence of continuous inflow. This continuous inflow necessitates plane-based emission of particle traces from the inlet veins, leading to particles that represents different amounts of blood, and related quantification errors. The purpose of this study was to develop a novel fixed-volume approach for particle tracing and employ this method to develop quantitative analysis of 4D blood flow characteristics in the left atrium. 4D Flow MRI data were acquired during free-breathing using a navigator-gated gradient-echo sequence in three volunteers at 1.5T. Fixed-volume particle traces emitted from the pulmonary veins were used to visualize left atrial blood flow and to quantitatively separate the flow into two functionally distinct flow components: Direct flow=particle traces that enter and leave the atrium in one heartbeat, Retained flow=particle traces that enter the atrium and remains there for one cardiac cycle. Flow visualization based on fixed-volume traces revealed that, beginning in early ventricular systole, flow enters the atrium and engages with residual blood volume to form a vortex. In early diastole during early ventricular filling, the organized vortical flow is extinguished, followed by formation of a second transient atrial vortex. Finally, in late diastole during atrial contraction, a second acceleration of blood into the ventricle is seen. The direct and retained left atrial flow components were between 44 and 57% and 43-56% of the stroke volume, respectively. In conclusion, fixed-volume particle tracing permits separation of left atrial blood flow into different components based on the transit of blood through the atrium.


Assuntos
Átrios do Coração/diagnóstico por imagem , Hemodinâmica , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia , Volume Sanguíneo , Feminino , Voluntários Saudáveis , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Ventrículos do Coração , Humanos , Imageamento Tridimensional , Masculino , Tamanho da Partícula , Sístole , Adulto Jovem
13.
Int J Cardiovasc Imaging ; 34(4): 587-596, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29098524

RESUMO

The impact of left bundle branch block (LBBB) related mechanical dyssynchrony on left ventricular (LV) diastolic function remains unclear. 4D flow cardiovascular magnetic resonance (CMR) has provided reliable markers of LV dysfunction: reduced volume and kinetic energy (KE) of the portion of LV inflow which passes directly to outflow (Direct Flow) has been demonstrated in failing hearts compared to normal hearts. We sought to investigate the impact of mechanical dyssynchrony on diastolic function by comparing 4D flow in myopathic LVs with and without LBBB. CMR data were acquired at 3 T in 22 heart failure patients; 11 with LBBB and 11 without LBBB matched according to several demographic and clinical parameters. An established 4D flow analysis method was used to separate the LV end-diastolic (ED) volume into functional flow components based on the blood's timing and route through the heart cavities. While the Direct Flow volume was not different between the groups, the KE possessed at ED was lower in LBBB patients (P = 0.018). Direct Flow entering the LV during early diastolic filling possessed less KE at ED in LBBB patients compared to non-LBBB patients, whereas no intergroup difference was observed during late filling. Pre-systolic KE of LV Direct Flow was reduced in patients with LBBB compared to matched patients with normal conduction. These intriguing findings propose that 4D flow specific measures can serve as markers of LV mechanical dyssynchrony in heart failure patients, and could possibly be investigated as predictors of response to cardiac resynchronization therapy.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Contração Miocárdica , Imagem de Perfusão do Miocárdio/métodos , Função Ventricular Esquerda , Adulto , Idoso , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Bloqueio de Ramo/fisiopatologia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes
14.
Sci Rep ; 7(1): 2971, 2017 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-28592851

RESUMO

Left bundle branch block (LBBB) causes left ventricular (LV) dyssynchrony which is often associated with heart failure. A significant proportion of heart failure patients do not demonstrate clinical improvement despite cardiac resynchronization therapy (CRT). How LBBB-related effects on LV diastolic function may contribute to those therapeutic failures has not been clarified. We hypothesized that LV hemodynamic forces calculated from 4D flow MRI could serve as a marker of diastolic mechanical dyssynchrony in LBBB hearts. MRI data were acquired in heart failure patients with LBBB or matched patients without LBBB. LV pressure gradients were calculated from the Navier-Stokes equations. Integration of the pressure gradients over the LV volume rendered the hemodynamic forces. The findings demonstrate that the LV filling forces are more orthogonal to the main LV flow direction in heart failure patients with LBBB compared to those without LBBB during early but not late diastole. The greater the conduction abnormality the greater the discordance of LV filling force with the predominant LV flow direction (r2 = 0.49). Such unique flow-specific measures of mechanical dyssynchrony may serve as an additional tool for considering the risks imposed by conduction abnormalities in heart failure patients and prove to be useful in predicting response to CRT.


Assuntos
Bloqueio de Ramo/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/parasitologia , Idoso , Biomarcadores , Eletrocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
15.
J Magn Reson Imaging ; 46(5): 1389-1399, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28295788

RESUMO

PURPOSE: Hemodynamic atlases can add to the pathophysiological understanding of cardiac diseases. This study proposes a method to create hemodynamic atlases using 4D Flow magnetic resonance imaging (MRI). The method is demonstrated for kinetic energy (KE) and helicity density (Hd ). MATERIALS AND METHODS: Thirteen healthy subjects underwent 4D Flow MRI at 3T. Phase-contrast magnetic resonance cardioangiographies (PC-MRCAs) and an average heart were created and segmented. The PC-MRCAs, KE, and Hd were nonrigidly registered to the average heart to create atlases. The method was compared with 1) rigid, 2) affine registration of the PC-MRCAs, and 3) affine registration of segmentations. The peak and mean KE and Hd before and after registration were calculated to evaluate interpolation error due to nonrigid registration. RESULTS: The segmentations deformed using nonrigid registration overlapped (median: 92.3%) more than rigid (23.1%, P < 0.001), and affine registration of PC-MRCAs (38.5%, P < 0.001) and affine registration of segmentations (61.5%, P < 0.001). The peak KE was 4.9 mJ using the proposed method and affine registration of segmentations (P = 0.91), 3.5 mJ using rigid registration (P < 0.001), and 4.2 mJ using affine registration of the PC-MRCAs (P < 0.001). The mean KE was 1.1 mJ using the proposed method, 0.8 mJ using rigid registration (P < 0.001), 0.9 mJ using affine registration of the PC-MRCAs (P < 0.001), and 1.0 mJ using affine registration of segmentations (P = 0.028). The interpolation error was 5.2 ± 2.6% at mid-systole, 2.8 ± 3.8% at early diastole for peak KE; 9.6 ± 9.3% at mid-systole, 4.0 ± 4.6% at early diastole, and 4.9 ± 4.6% at late diastole for peak Hd . The mean KE and Hd were not affected by interpolation. CONCLUSION: Hemodynamic atlases can be obtained with minimal user interaction using nonrigid registration of 4D Flow MRI. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1389-1399.


Assuntos
Coração/anatomia & histologia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Angiografia , Diástole , Feminino , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Hidrodinâmica , Cinética , Masculino , Microscopia de Contraste de Fase , Valores de Referência , Volume Sistólico , Sístole , Função Ventricular Esquerda , Adulto Jovem
16.
PLoS One ; 11(8): e0161391, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27532640

RESUMO

AIMS: 4D flow magnetic resonance imaging (MRI) allows quantitative assessment of left ventricular (LV) function according to characteristics of the dynamic flow in the chamber. Marked abnormalities in flow components' volume and kinetic energy (KE) have previously been demonstrated in moderately dilated and depressed LV's compared to healthy subjects. We hypothesized that these 4D flow-based measures would detect even subtle LV dysfunction and remodeling. METHODS AND RESULTS: We acquired 4D flow and morphological MRI data from 26 patients with chronic ischemic heart disease with New York Heart Association (NYHA) class I and II and with no to mild LV systolic dysfunction and remodeling, and from 10 healthy controls. A previously validated method was used to separate the LV end-diastolic volume (LVEDV) into functional components: direct flow, which passes directly to ejection, and non-ejecting flow, which remains in the LV for at least 1 cycle. The direct flow and non-ejecting flow proportions of end-diastolic volume and KE were assessed. The proportions of direct flow volume and KE fell with increasing LVEDV-index (LVEDVI) and LVESV-index (LVESVI) (direct flow volume r = -0.64 and r = -0.74, both P<0.001; direct flow KE r = -0.48, P = 0.013, and r = -0.56, P = 0.003). The proportions of non-ejecting flow volume and KE rose with increasing LVEDVI and LVESVI (non-ejecting flow volume: r = 0.67 and r = 0.76, both P<0.001; non-ejecting flow KE: r = 0.53, P = 0.005 and r = 0.52, P = 0.006). The proportion of direct flow volume correlated moderately to LVEF (r = 0.68, P < 0.001) and was higher in a sub-group of patients with LVEDVI >74 ml/m2 compared to patients with LVEDVI <74 ml/m2 and controls (both P<0.05). CONCLUSION: Direct flow volume and KE proportions diminish with increased LV volumes, while non-ejecting flow proportions increase. A decrease in direct flow volume and KE at end-diastole proposes that alterations in these novel 4D flow-specific markers may detect LV dysfunction even in subtle or subclinical LV remodeling.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ventrículos do Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Idoso , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Sístole/fisiologia
17.
Physiol Rep ; 4(3)2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26841965

RESUMO

We hypothesized that the direction of global left ventricular (LV) hemodynamic forces during diastolic filling are concordant with the main flow axes in normal LVs, but that this pattern would be altered in dilated and dysfunctional LVs. Therefore, we aimed to assess the LV hemodynamic filling forces in a group of healthy subjects and compare them to the results from a group of patients with dilated cardiomyopathy (DCM). Ten healthy subjects and 10 DCM patients were enrolled. Morphological short- (SAx) and long-axis (LAx) images and 4D flow MRI data were acquired at 1.5T. The LV pressure gradients were computed from the 4D flow data using the Navier-Stokes equations. By integrating the pressure gradients over the LV volume at each time frame, the magnitude and direction of the global hemodynamic force was calculated over the cardiac cycle. The hemodynamic forces acting in the SAx- and LAx-directions were used to calculate the "SAx-max/LAx-max"-ratio for the early (E-wave) and late (A-wave) diastolic filling. In the LAx-plane, the temporal progression of the hemodynamic force followed a consistent pattern in the healthy subjects. The "SAx-max/LAx-max"-ratio was significantly larger at both E-wave (0.53 ± 0.15 vs. 0.23 ± 0.12, P < 0.0001) and A-wave (0.44 ± 0.21 vs. 0.26 ± 0.09, P < 0.03) in the DCM patients compared to the healthy subjects. 4D flow MRI data allow quantification of LV hemodynamic forces acting on the LV myocardial wall. The LV hemodynamic filling forces showed a similar temporal progression among healthy subjects, whereas DCM patients had forces that were more heterogeneous in their direction and magnitude during diastole.


Assuntos
Cardiomiopatia Dilatada/fisiopatologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
18.
J Magn Reson Imaging ; 43(3): 558-65, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26213253

RESUMO

PURPOSE: To investigate whether 4D flow magnetic resonance imaging (MRI) can detect subtle right ventricular (RV) dysfunction in primary left ventricular (LV) disease. MATERIALS AND METHODS: 4D flow and morphological 3T MRI data were acquired in 22 patients with mild ischemic heart disease who were stratified into two groups based on LV end-diastolic volume index (EDVI): lower-LVEDVI and higher-LVEDVI, as well as in 11 healthy controls. The RV volume was segmented at end-diastole (ED) and end-systole (ES). Pathlines were emitted from the ED volume and traced forwards and backwards in time to ES. The blood volume was separated into flow components. The Direct Flow (DF) component was defined as RV inflow passing directly to outflow. The kinetic energy (KE) of the DF component was calculated. Echocardiographic conventional RV indices were also assessed. RESULTS: The higher-LVEDVI group had larger LVEDVI and lower LV ejection fraction (98 ± 32 ml/m(2) ; 48 ± 13%) compared to the healthy (67 ± 12, P = 0.002; 64 ± 7, P < 0.001) and lower-LVEDI groups (62 ± 10; 68 ± 7, both P < 0.001). The RV 4D flow-specific measures "DF/EDV volume-ratio" and "DF/EDV KE-ratio at ED" were lower in the higher-LVEDVI group (38 ± 5%; 52 ± 6%) compared to the healthy (44 ± 6; 65 ± 7, P = 0.018 and P < 0.001) and lower-LVEDVI groups (44 ± 6; 64 ± 7, P = 0.011 and P < 0.001). There was no difference in any of the conventional MRI and echocardiographic RV indices between the three groups. CONCLUSION: We found that in primary LV disease mild impairment of RV function can be detected by 4D flow-specific measures, but not by the conventional MRI and echocardiographic indices.


Assuntos
Ventrículos do Coração/fisiopatologia , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Idoso , Algoritmos , Diástole , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Cinética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Projetos Piloto , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita
19.
Proteome Sci ; 15: 8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28439209

RESUMO

BACKGROUND: Data from biological samples and medical evaluations plays an essential part in clinical decision making. This data is equally important in clinical studies and it is critical to have an infrastructure that ensures that its quality is preserved throughout its entire lifetime. We are running a 5-year longitudinal clinical study, KOL-Örestad, with the objective to identify new COPD (Chronic Obstructive Pulmonary Disease) biomarkers in blood. In the study, clinical data and blood samples are collected from both private and public health-care institutions and stored at our research center in databases and biobanks, respectively. The blood is analyzed by Mass Spectrometry and the results from this analysis then linked to the clinical data. METHOD: We built an infrastructure that allows us to efficiently collect and analyze the data. We chose to use REDCap as the EDC (Electronic Data Capture) tool for the study due to its short setup-time, ease of use, and flexibility. REDCap allows users to easily design data collection modules based on existing templates. In addition, it provides two functions that allow users to import batches of data; through a web API (Application Programming Interface) as well as by uploading CSV-files (Comma Separated Values). RESULTS: We created a software, DART (Data Rapid Translation), that translates our biomarker data into a format that fits REDCap's CSV-templates. In addition, DART is configurable to work with many other data formats as well. We use DART to import our clinical chemistry data to the REDCap database. CONCLUSION: We have shown that a powerful and internationally adopted EDC tool such as REDCap can be extended so that it can be used efficiently in proteomic studies. In our study, we accomplish this by using DART to translate our clinical chemistry data to a format that fits the templates of REDCap.

20.
J Cardiovasc Magn Reson ; 17: 87, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26438074

RESUMO

BACKGROUND: Flow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity encoding (4D flow CMR) permits assessment of net flow volumes and flow patterns retrospectively at any location in a time-resolved 3D volume. However, analysis of these datasets can be demanding. The aim of this study is to develop and evaluate a fully automatic method for segmentation and analysis of 4D flow CMR data of the great thoracic vessels. METHODS: The proposed method utilizes atlas-based segmentation to segment the great thoracic vessels in systole, and registration between different time frames of the cardiac cycle in order to segment these vessels over time. Additionally, net flow volumes are calculated automatically at locations of interest. The method was applied on 4D flow CMR datasets obtained from 11 healthy volunteers and 10 patients with heart failure. Evaluation of the method was performed visually, and by comparison of net flow volumes in the ascending aorta obtained automatically (using the proposed method), and semi-automatically. Further evaluation was done by comparison of net flow volumes obtained automatically at different locations in the aorta, pulmonary artery, and caval veins. RESULTS: Visual evaluation of the generated segmentations resulted in good outcomes for all the major vessels in all but one dataset. The comparison between automatically and semi-automatically obtained net flow volumes in the ascending aorta resulted in very high correlation (r (2)=0.926). Moreover, comparison of the net flow volumes obtained automatically in other vessel locations also produced high correlations where expected: pulmonary trunk vs. proximal ascending aorta (r (2)=0.955), pulmonary trunk vs. pulmonary branches (r (2)=0.808), and pulmonary trunk vs. caval veins (r (2)=0.906). CONCLUSIONS: The proposed method allows for automatic analysis of 4D flow CMR data, including vessel segmentation, assessment of flow volumes at locations of interest, and 4D flow visualization. This constitutes an important step towards facilitating the clinical utility of 4D flow CMR.


Assuntos
Aorta/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Artéria Pulmonar/fisiopatologia , Veia Cava Inferior/fisiopatologia , Veia Cava Superior/fisiopatologia , Adulto , Idoso , Automação , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Meios de Contraste , Insuficiência Cardíaca/fisiopatologia , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...