1.
Kyobu Geka ; 76(11): 928-932, 2023 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-38056950

RESUMO

This is a 2-case report of concomitant left atrial( LA) surgical ablation through the left atrial appendage( LAA) for atrial fibrillation( AF) during aortic valve replacement( AVR). Case 1, a 74-year-old man, and Case 2, an 85-years-old woman, were presented for AVR and AF. Under the cardio-pulmonary bypass, right and left pulmonary vein isolations( PVIs) were performed with radiofrequency( RF) ablation devices. Through the opened LAA, an RF lesion was placed to connect the bilateral PVIs and the LAA, and another RF line was placed toward the mitral annulus. A right atrial( RA) isthmus ablation was also performed through a RA incision. Postoperatively, sinus rhythm and both RA and LA contraction were obtained, and have been maintained for 7.5 and 5 years without classⅠ/Ⅲ antiarrhythmic drugs in Case 1 and 2, respectively. This procedure is considered to be effective and safe, although further study is needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Masculino , Feminino , Humanos , Idoso de 80 Anos ou mais , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Átrios do Coração/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos
2.
Kyobu Geka ; 75(2): 83-87, 2022 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-35249081

RESUMO

This report presents a modified procedure of tricuspid valve ring annuloplasty (R-TAP) with posterior annular plication for functional tricuspid regurgitation (TR). Sutures on the native annulus were placed by a standard fashion in R-TAP, and those on the posterior annulus and its bilateral commissures were passed through in a narrow range between the 3 and 4 o'clock positions of the 26-mm ring. The other sutures were done with an usual manner and the ring was fixed to the annulus, resulting in the posterior annular plication( bicuspidization). Follow-up was performed for more than 5 years( mean: 7.9 years, range:5.5~11.5 years) by echocardiography in 13 cases. Postoperative TR reduced significantly to less than moderate, which was maintained during the entire follow-up period, even in the case with atrial fibrillation. There was no sign of tricuspid stenosis. R-TAP with posterior annular plication was feasible, reproducible, and effective, although further investigation is needed.


Assuntos
Anuloplastia da Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia , Seguimentos , Humanos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
3.
Kyobu Geka ; 72(12): 969-973, 2019 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-31701905

RESUMO

This is a 3-case report of mitral valve replacement (MVR) with an On-X mechanical valve followed up to 10 years. Case 1(64-year-old man) and case 2 (66-year-old woman) experienced traffic accident and traumatic event, respectively, in their chronic phase after MVR. Case 1 had multiple bone fractures of the bilateral lower limbs, which was followed by systemic infection and pyogenic spondylitis. He needed long-term antibiotics therapy for more than 4 years. Case 2 fell down at home and severely hit her head, which resulted in a traumatic subarachnoid hemorrhage. She was in a deep coma, and needed discontinuation of anticoagulation therapy for 4 weeks. Case1, 2, and 3(54-year-old man) are doing well in New York Heart Association functional class I without any valve-related thromboembolic or hemorrhagic events at 10, 9 and 8 years after MVR, respectively. On-X valve performance has also been found well maintained in all cases by echocardiography, even after traumatic accident or discontinuation of anticoagulation in Case 1 and 2. In this report, the On-X mechanical valve demonstrated good midterm result of its valve performance in the mitral position and its potential advantages in antithrombogenicity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Tromboembolia , Idoso , Anticoagulantes , Valva Aórtica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Kyobu Geka ; 68(7): 496-9, 2015 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-26197823

RESUMO

This report discusses intraoperative endoscopic evaluation of the aortic valve performed in 2 cases of aortic valve repair. The "direct" or real image by the endoscopy helped to confirm the preoperatively-known lesion and even to detect a new legion which was not detected preoperatively. The endoscopy also enabled the evaluation of the aortic valve under the pressure-loaded condition without releasing the aortic clamp. Postoperative aortic regurgitation was grade I or less in both cases, although it progressed to grade II at 1 year in case 2. Echocardiographic parameters demonstrated no change in the size of the aortic root configuration for 8 and 5 years in case 1 and case 2, respectively. Intraoperative aortic endoscopy was useful to define the pathogenesis of aortic regurgitation and to evaluate the cusp repair procedures, which may contribute to a good mid-term result of aortic valve repair.


Assuntos
Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Endoscopia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica , Fatores de Risco , Resultado do Tratamento