1.
Clin Chim Acta ; 548: 117464, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37399883

RESUMO

BACKGROUND: Peripheral venous blood (PVB) gas analysis has become an alternative to arterial blood gas (BG) analysis in assessing acid-base balance. This study aimed to compare the effects of blood collection devices and modes of transportation on peripheral venous BG parameters. METHODS: PVB-paired specimens were collected from 40 healthy volunteers into blood gas syringes (BGS) and blood collection tubes (BCT), transported by either a pneumatic tube system (PTS) or human courier (HC) to the clinical laboratory, and compared using a two-way ANOVA or Wilcoxon signed-rank test. To determine clinical significance, the PTS and HC-transported BGS and BCT biases were compared to the total allowable error (TEA). RESULTS: PVB partial pressure of oxygen (pO2), fractional oxyhemoglobin (FO2Hb), fractional deoxyhemoglobin (FHHb), and oxygen saturation (sO2) showed statistically significant differences between BGS and BCT (p < 0.0001). Compared to HC-transported BGS and BCT, statistically significant increases in pO2, FO2Hb, sO2, oxygen content (only in BCT) (all p < 0.0001), and base excess extracellular (only in BCT; p < 0.0014) concentrations and a statistically significant decrease in FHHb concentration (p < 0.0001) were found in BGS and BCT delivered by PTS. The biases between PTS- and HC-transported BGS and BCT exceeded the TEA for many BG parameters. CONCLUSIONS: Collecting PVB in BCT is unsuitable for pO2, sO2, FO2Hb, FHHb, and oxygen content determinations.


Assuntos
Coleta de Amostras Sanguíneas , Meios de Transporte , Humanos , Gasometria , Oxigênio , Dióxido de Carbono
2.
Clin Chim Acta ; 531: 342-351, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35513039

RESUMO

BACKGROUND: We discovered that blood collection tubes (BCTs) were inadvertently recentrifuged due to improper placement on our automated preanalytical system. This study was undertaken to determine the impact of recentrifugation of blood specimens collected in serum separator (SSTs) and plasma separator (PSTs) tubes after refrigerated storage for 24 and 72 h on the concentrations of chemistry and immunochemistry analytes. METHODS: Blood was collected from 20 volunteers in SSTs and PSTs, centrifuged, and 36 chemistry and 14 immunochemistry analytes were measured at baseline in single-centrifuged tubes on a Roche Cobas 8000 chemistry platform. After baseline testing, the BCTs were refrigerated for 24 or 72 h, recentrifuged and retested. The results were compared to the single-centrifuged tubes for statistical significance. RESULTS: Recentrifugation of BCTs after 24 or 72 h of refrigerated storage showed statistically significant increases in lactate dehydrogenase activity and potassium concentration and statistically significant decreases in glucose (except in SSTs after 24 h of refrigerated storage) and CO2 concentration, but no significant differences in immunochemistry analyte concentrations. CONCLUSION: It may be safe to report most routine chemistry and immunochemistry analyte concentrations from recentrifuged SSTs and PSTs on the Roche Cobas 8000, which may save time and costs associated with recollection and retesting.


Assuntos
Coleta de Amostras Sanguíneas , Plasma , Coleta de Amostras Sanguíneas/métodos , Centrifugação , Humanos , Imunoquímica , Potássio
4.
Clin Biochem ; 49(1-2): 90-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26375014

RESUMO

OBJECTIVE: The objective of this study was to compare newly-modified and aged chemoPET tubes, which contain no problematic surfactants, with commercially available serum blood collection tubes (BCTs) for use in analysis of cortisol, total triiodothyronine (TT3), total thyroxine (TT4), and routine clinical chemistry analytes in serum from apparently healthy volunteers and pooled quality control (QC) specimens. MATERIALS AND METHODS: Blood specimens collected from 60 apparently healthy volunteers (18 males, 42 females) and pooled QC specimens poured into seven different BCTs were analyzed by a trained phlebotomist. Cortisol, TT3, and TT4 levels were measured on an Immulite 1000 instrument and routine chemistry tests were analyzed on a Siemens RxL instrument. The significance of differences between chemoPET and other BCT types compared to glass tubes were assessed by Student's paired t-test or repeated measures ANOVA or their non-parametric equivalents. The BCT-related biases (deviation from glass tubes) in analyte concentrations were compared with the current desirable allowable bias, derived from biological variation. Serum analyte concentrations in the different BCTs that exceeded their respective significant change limits were considered clinically significant. RESULTS: No statistically and/or clinically significant differences were noted in the analyte concentrations from serum specimens and pooled QC material when our newly modified and aged chemoPET tubes were compared to glass and other BCTs. CONCLUSIONS: The chemoPET tubes described here may be a suitable alternative to serum BCTs that contain problematic surfactants known to interfere with some clinical assays on the Immulite 1000 and RxL instruments.


Assuntos
Flebotomia/instrumentação , Humanos , Controle de Qualidade