Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 216(5): 1267-1272, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33703927

RESUMO

OBJECTIVE. The purpose of this study was to determine clinical outcomes of patients undergoing TIPS reduction. MATERIALS AND METHODS. In this institutional review board-approved, HIPAA-compliant study, all TIPS reductions performed at two institutions from January 1, 2008 to January 31, 2016, were retrospectively identified. Patients were divided into two groups according to pre-TIPS symptoms: volume overload due to ascites or hydrothorax (VO; n = 14) or variceal bleeding (VB; n = 12). Patient demographics, pre-TIPS model for end-stage liver disease score, pre- and post-TIPS portosystemic gradients, and clinical parameters were recorded. The primary endpoint was change in symptoms of hepatic encephalopathy (HE; West Haven criteria), right heart failure, or liver dysfunction. Secondary endpoints included paracentesis rate for the VO group and rebleeding for the VB group. RESULTS. The degree of HE increased in 24 of 26 patients (92%) after TIPS placement and decreased in 24 of 26 patients (92%) after TIPS reduction. Mean West Haven scores for the VO group decreased after TIPS reduction (from 2.57 ± 0.97 [SD] to 1.07 ± 0.70; p < .001). Mean West Haven scores for the VB group also decreased after TIPS reduction (from 2.45 ± 0.89 to 1.27 ± 0.86; p = .007). Right heart failure improved in two of three patients (67%), and total bilirubin improved in one of three patients (33%). Follow-up data were available up to median of 134 days (interquartile range, 44-286). TIPS reduction led to an increased paracentesis rate compared with before TIPS placement in four of 14 patients with VO (29%). One patient had a stable paracentesis rate after TIPS reduction compared with before TIPS placement. Variceal rebleeding did not occur in any patients with VB after TIPS reduction. At 54 days after TIPS reduction, one of the 12 patients with VB (9%) experienced hematemesis due to an endoscopically proven band-related ulcer. CONCLUSION. TIPS reduction successfully resolved HE and refractory right heart failure in most patients. In patients with VB, TIPS reduction with variceal embolization results in a low risk of short-term recurrent VB. However, in patients with VO, ascites may return or worsen after TIPS reduction despite improvement in HE.


Assuntos
Insuficiência Cardíaca/cirurgia , Encefalopatia Hepática/cirurgia , Hepatopatias/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Cardiovasc Intervent Radiol ; 40(7): 1118-1122, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28175974

RESUMO

Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.


Assuntos
Ampola Hepatopancreática , Colestase Extra-Hepática/terapia , Doenças do Ducto Colédoco/terapia , Remoção de Dispositivo , Hipersensibilidade/terapia , Níquel/efeitos adversos , Stents/efeitos adversos , Feminino , Humanos , Hipersensibilidade/diagnóstico , Pessoa de Meia-Idade , Testes do Emplastro
3.
AJR Am J Roentgenol ; 208(3): 650-655, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27959638

RESUMO

OBJECTIVE: Transjugular intrahepatic portosystemic shunt (TIPS) with variceal embolization is routinely performed to treat variceal bleeding. Embolization using vascular plugs is reported, but outcomes are not known. Outcomes and material costs of embolization using vascular plugs and coils are compared. MATERIALS AND METHODS: A single center's medical records of TIPS procedures (May 2003-December 2014) with variceal embolization were reviewed. Twenty patients with vascular plug embolization (age [± SD], 50 ± 10 years; seven men and 13 women; median Model for End-Stage Liver Disease [MELD], 20; interquartile range [IQR], 14-23) were compared with an age-, sex-, and MELD-matched cohort who underwent coil embolization (age, 50 ± 9 years; seven men and 13 women; median MELD, 17; IQR, 15-19; p = 0.52). Procedure details, primary outcome (rebleeding), secondary outcome (mortality), and costs were compared. RESULTS: Vascular plug use was associated with a lower fluoroscopy time (49.05 minutes [IQR, 36-62] vs 68 minutes [IQR, 49-76]; p = 0.006) and total procedure time (255 minutes [IQR, 205-290] for vascular plugs vs 275 minutes [IQR, 230-330]; p = 0.05). Total volume of contrast agent used was similar (180 mL [IQR, 155-234] for vascular plugs vs 210 mL [IQR, 185-261]; p = 0.14). In patients with at least a 30-day follow-up, rebleeding rates (2/17 [12%] for vascular plugs vs 4/15 [27%]; p = 0.40) and mortality (2/17 [12%] for vascular plugs vs 4/15 [27%]; p = 0.66) were similar. Per procedure, vascular plugs cost significantly more than coils ($1292 ± $676 vs $228 ± $292, p < 0.0001). CONCLUSION: The use of vascular plugs or coils has similar outcomes for variceal embolization after TIPS. The advantages of vascular plug use (i.e., reduced fluoroscopy or procedure time) may be offset by increased material cost, a trade-off that merits further study given current cost concerns in health care.


Assuntos
Embolização Terapêutica/instrumentação , Varizes Esofágicas e Gástricas/terapia , Hemorragia Gastrointestinal/terapia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Terapia Combinada/métodos , Embolização Terapêutica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Feminino , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Derivação Portossistêmica Transjugular Intra-Hepática/instrumentação , Estudos Retrospectivos , Resultado do Tratamento , Varizes
4.
Semin Intervent Radiol ; 32(2): 195-208, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26038626

RESUMO

Iatrogenic injury to the urinary tract, including the kidneys, ureters, bladder, and urethra, is a potential complication of surgical procedures performed in or around the retroperitoneal abdominal space or pelvis. While both diagnostic and interventional radiologists often play a central and decisive role in the identification and initial management of a variety of iatrogenic injuries, discussions of these injuries are often directed toward specialists such as urologists, obstetricians, gynecologists, and general surgeons whose procedures are most often implicated in iatrogenic urinary tract injuries. Interventional radiologic procedures can also be a source of an iatrogenic urinary tract injury. This review describes the clinical presentation, risk factors, imaging findings, and management of iatrogenic renal vascular and urinary tract injuries, as well as the radiologist's role in the diagnosis, treatment, and cause of these injuries.

5.
J Vasc Interv Radiol ; 23(9): 1233-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22920982

RESUMO

Various adjunctive techniques have been reported for challenging inferior vena cava (IVC) filter retrievals (1-4). One particularly challenging obstacle to successful IVC filter retrieval is the formation of a radiolucent fibrin cap over the embedded apex of the IVC filter. This obstacle is a result of filter tilting that creates turbulent blood flow, which promotes fibrin cap formation. The aim of this brief report is to depict a novel technique for IVC filter retrieval: guide wire-manipulated disruption of the fibrin cap.


Assuntos
Remoção de Dispositivo/métodos , Fibrina/metabolismo , Filtros de Veia Cava , Veia Cava Inferior/cirurgia , Catéteres , Remoção de Dispositivo/instrumentação , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia Intervencionista , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...