1.
Artigo em Inglês | MEDLINE | ID: mdl-38797375

RESUMO

Among the symptoms presented by patients with SARS-Cov-2 infection, we can find various otorhinolaryngological alterations. Dysphonia appears in up to 79% of infected patients during the acute phase. Dysphonia can also occur as a sequelae, often underestimated, possibly due to its appearance along with other symptoms, also in patients after prolonged intubation or tracheostomy. We present a systematic review of the literature with a bibliographic search in PubMed, Cochrane and Google Scholar, with MESH terms including studies in English and Spanish. The results of the studies found and the vocal manifestations in patients during COVID-19 disease and the consequences produced are analysed. Dysphonia is an acute manifestation of COVID-19 with alterations in aerodynamic and acoustic analysis and in fibrolaryngoscopy. Post-COVID dysphonia can be a persistent symptom that is often underestimated, requiring multidisciplinary management and speech therapy intervention. Laryngeal sequelae are common in post-intubation or post-tracheostomy patients and are related to intubation time, tube number, pronation and respiratory sequelae.

2.
Acta otorrinolaringol. esp ; 75(1): 23-30, ene.-feb. 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229268

RESUMO

Introducción El umbral de confort máximo o maximum comfort level (MCL), umbral eléctrico o threshold level (THR) e impedancia eléctrica cambian en el postoperatorio del implante coclear durante meses hasta estabilizarse. El objetivo de este artículo es establecer la variación durante cinco años posquirúrgicos de la impedancia, y su relación con MCL en adultos implantados unilateralmente. Métodos Estudio retrospectivo a cinco años, con 78 pacientes adultos implantados con MED-EL en un hospital terciario desde el año 2000 hasta 2015. Se analizó la variación de impedancia, MCL y relación entre ellos, en electrodos basales (9-12), medios (5-8) y apicales (1-4), realizando análisis inferencial ANOVA de medidas repetidas con comparaciones entre tiempos consecutivos, corregidas con criterio Bonferroni. Resultados Treinta y tres hombres (42,3%) y 45 mujeres (57,7%), con edad media 52,7 ± 14,6 años. Se consideró «estabilidad» el momento del seguimiento sin diferencias estadísticamente significativas entre una visita y la siguiente. Los cambios en la impedancia en electrodos medios dejaron de ser estadísticamente significativos a los tres meses, y en apicales a los seis meses, con valores medios de 5,84 y 6,43 kohms. MCL se estabilizó a los dos años en electrodos basales y apicales, y a los tres años en medios, con valores medios de 24,9, 22,7 y 25,6 qu. Hubo correlación entre MCL e impedancia en electrodos medios hasta 3 meses y en apicales hasta un año. Conclusiones La impedancia eléctrica desciende significativamente en electrodos medios y apicales hasta tres y seis meses. El MCL aumenta significativamente hasta dos años. La impedancia se relaciona con MCL hasta seis meses. (AU)


Introduction The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. Methods Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. Results 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7 ± 14.6 years. “Stability” was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43 kohms. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6 qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. Conclusions Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Impedância Elétrica , Implantes Cocleares/efeitos adversos , Telemetria , Estudos Retrospectivos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38224870

RESUMO

INTRODUCTION: The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. METHODS: Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. RESULTS: 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7±14.6 years. "Stability" was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43kΩ. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. CONCLUSIONS: Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.


Assuntos
Implante Coclear , Implantes Cocleares , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Impedância Elétrica , Estudos Retrospectivos , Limiar Auditivo