Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(20)2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36294443

RESUMO

Heart failure with reduced ejection fraction (LV-EF < 35%) is diagnosed in app. 11,000,000 patients worldwide. For the treatment of these patients, guideline directed medical therapy has proven to reduce mortality and rehospitalization regardless of the disease's etiology. It is implemented to treat clinical symptoms by improving the left ventricular ejection fraction. Patients with a transient risk of ventricular tachycardia and sudden cardiac death can be protected by a defibrillator vest. The defibrillator vest is capable to detect and terminate ventricular arrhythmias during Guideline Directed Medical Therapy (GDMT). It is based on the recommendations of the European society of cardiology for 3 months. Afterwards, the WCD wear time could be prolonged, or, in case of persistent low ejection fraction (LV-EF ≤ 35%), an implantable cardioverter defibrillator (ICD) should be implanted, as shown in the WEARIT-II-registry. Our goal was to evaluate the effects of GDMT on LV-recovery and reduction of ICD implantations under protection with a defibrillator vest­depending on the uptitration of GDMT. Methods: 339 consecutive patients between August 2017 and September 2020 with newly diagnosed cardiomyopathy and an EF ≤ 35% were analyzed retrospectively by chart review. All patients were protected by a wearable cardioverter defibrillator (WCD). GDMT as recommended by the ESC started at discharge from hospital. The left ventricular ejection fraction (LV-EF) was determined by transthoracic echocardiography at week 4, 8 and at week 12 (in case of prolonged WCD wear time). Uptitration was performed after 4 and 8 weeks during patient visits. We focused on baseline medication as per GDMT and the dosage increase at week 4, 8 and 12. The aim was the uptitration to the maximum dosage tolerated by the patient. We also compared the LV-EF improvement in the group with and without uptitration of medication dosage. Results: The patient age was, on average, 63.2 years (SD ± 11.9 years). A total of 129 pts (38%) had ICM, 196 (58%) had NICM (incl 66 pts (19%) with DCM and 51 pts (15%) with Myocarditis, 79 pts (24%) with unknown origin) and 14 pts (4%) had other entities (e.g., Tachycardiomyopathy). In total, 21 pts (6%) had an LV-EF of less than 16%, 130 pts (38%) between 16−25% and 183 pts (54%) between 26−35%. GDMT started at discharge from the hospital included treatment with beta blocker for 327 pts (96.5%), ACE-inhibitors/Angiotensin/ARNI for 283 pts (83.5%) and Mineralcorticoid receptor antagonists (MRA) for 334 pts (88.4%). Uptitration was performed in all groups at a rate of 82.3%, 91.1% and 81.0% after 4 weeks and 64.7%, 50.3% and 66.3% after 8 weeks, respectively. After 4 weeks, 25 pts (7.4%) and, after 8 weeks, 171 pts (50.4%) had an EF increase of 5% or more (mean 14.2%). After 4 weeks, 81 patients had an LV-EF more than 35%. A total of 169 pts had a wear time of 12 weeks and an improvement of LVEF of more than 35%. Interestingly, in our study we did not find a significant difference in LV-EF improvement between the group with no uptitration and the group with uptitration. Conclusions: Guideline-directed medical therapy under protection with a WCD from ventricular arrhythmia can reduce the need for implantation of an ICD and can lead to an improvement of ejection fraction. Interestingly, the LV-EF improvement depends on the GDMT at discharge. Current guidelines recommend an initiation of all therapy columns of GDMT (sacubitril/valsartan, ACE-inhibitor/AT1-blocker, mineralcorticoidreceptorblocker, beta blocker) at once and further uptitration to the maximal dosage (ESC Guidelines 2021). A further uptitration of all drugs of GDMT should lead to improvement of LV-EF and consequently to a reduction in ICD implantations.

2.
J Clin Med ; 11(10)2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35629031

RESUMO

Guideline-directed medical therapy (GDMT) is crucial in reducing mortality in patients with heart failure with heart rate lowering by a beta blocker (BB) being an important therapeutic concept. We aimed to assess the usefulness of a wearable cardioverter/defibrillator (WCD) to provide detailed information about heart rate for managing patients with reduced left ventricular ejection fraction (LVEF) and symptoms of heart failure and to correlate mortality with the mean heart rate. A total of 4509 consecutive patients (mean age: 59 + 13 years, 88% male) were analyzed retrospectively. All patients had reduced LVEF and were prescribed a WCD for protection from sudden cardiac death (SCD) during GDMT uptitration awaiting LVEF recovery. The device continuously measured nighttime and daytime HR at the beginning and end of WCD use. Patients who died during wear time had significantly higher HRs compared with survivors: daytime beginning of use (BOU), 80 ± 15 bpm vs. 76 ± 13, p < 0.01; nighttime BOU, 76 ± 14 vs. 69 ± 13, p < 0.0001; daytime end of use (EOU), 84 ± 20 vs. 73 ± 13, p < 0.0001; nighttime EOU, 80 ± 20 vs. 65 ± 12, p < 0.0001). In conclusion, HR monitoring with a WCD yields important prognostic information and may assist in optimal usage of BB in patients with low LVEF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...