Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 11(5): 29, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35639406

RESUMO

Purpose: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. Methods: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. Results: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. Conclusions: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. Translational Relevance: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases.


Assuntos
Movimentos Sacádicos , Campos Visuais , Sensibilidades de Contraste , Humanos , Testes Visuais
2.
Transl Vis Sci Technol ; 10(12): 12, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34614164

RESUMO

Purpose: The aim of the current study was to develop and validate an automated contrast sensitivity (CS) test using a live- detection of optokinetic nystagmus (OKN) and an adaptive psychometric procedure. In addition, the study sought to replicate the known effect of defocus on CS for the OKN-based measurements in emmetropic participants. Methods: Fifteen participants viewed a horizontally moving grating while their eyes were tracked with an infra-red (IR) eye-tracker. To simulate the clinical conditions of the CS measurements, the participants were stimulated monocularly as the left eye was occluded by an IR filter. The horizontal eye position was continuously analyzed for OKN responses, and the stimulus contrast was changed by an adaptive psychometric method depending on the outcome. Furthermore, the newly proposed OKN live-detection was verified against an offline analysis and an expert-observer judgement. The OKN-based CS was measured for six spatial frequencies at normal vision and three levels of defocus using spherical convex lenses. Results: The newly proposed OKN live-detection method showed a sufficient detection performance for implementation of adaptive procedures, and the detection rate is similar or better compared to offline detection methods. Spatial frequency and defocus had a significant effect on the OKN-based CS (P < 0.0001 for both). Conclusions: The current study presents a novel method to measure motion CS in an automated way, combining the real-time detection of OKN and an adaptive psychometric procedure. Furthermore, the known effect of defocus on CS was successfully replicated with the newly developed tool. Translational Relevance: OKN-based CS is a novel approach to assess spatial vision, which is sensitive to subtle effects of defocus, allowing use with nonverbal patients and infants. Furthermore, the newly developed tool may improve the performance of such measurements.


Assuntos
Sensibilidades de Contraste , Nistagmo Optocinético , Humanos , Transtornos da Visão/diagnóstico , Testes Visuais , Visão Ocular
3.
J Eye Mov Res ; 11(4)2020 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-33828709

RESUMO

Microsaccades are involuntary eye movements occurring naturally during fixation. In this study, microsaccades were investigated under monocularly and binocularly stimulated conditions with respect to their directional distribution and rate signature, that refers to a curve reporting the frequency modulation of microsaccades over time. For monocular stimulation the left eye was covered by an infrared filter. In both stimulation conditions, participants fixated a Gabor patch presented randomly in orientation of 45° or 135° over a wide range of spatial frequencies appearing in the center of a monitor. Considering the microsaccadic directions, this study showed microsaccades to be preferably horizontally oriented in their mean direction, regardless of the spatial characteristics of the grating. Furthermore, this outcome was found to be consistent between both stimulation conditions. Moreover, this study found that the microsaccadic rate signature curve correlates between both stimulation conditions, while the curve given for binocular stimulation was already proposed as a tool for estimation of visual performance in the past. Therefore, this study extends the applicability of microsaccades to clinical use, since parameters as contrast sensitivity, has been measured monocularly in the clinical attitude.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...