Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
2.
J. Transcatheter Interv ; 30: eA20210020, 20220101. ilus
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1400033

RESUMO

A troca valvar mitral transcateter apresenta-se como uma nova opção terapêutica para o tratamento de próteses cirúrgicas degeneradas em pacientes com alto risco cirúrgico. É crescente o número de procedimentos valve-in-valve mitral ao longo dos últimos anos. O presente caso relata uma experiência inicial com esse tipo de procedimento, sendo efetivado de forma segura e eficaz em uma paciente idosa de alto risco cirúrgico para retroca valvar.


Transcatheter mitral valve replacement is a new option to treat deteriorated surgical prosthesis in high surgical risk patients. The number of valve-in-valve mitral procedures has been growing in the last few years. This case reports an initial experience with this type of procedure, safely and effectively performed in an elderly female patient with high-risk for valve replacement.

3.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1353336

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite , Substituição da Valva Aórtica Transcateter
4.
J Am Heart Assoc ; 10(18): e020682, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34546114

RESUMO

Background No study has evaluated the impact of the additional manipulation demanded by multiple resheathing (MR) in patients undergoing transcatheter aortic valve replacement with repositionable self-expanding valves. Methods and Results This study included a real-world, multicenter registry involving 16 centers from Canada, Germany, Latin America, and Spain. All consecutive patients who underwent transcatheter aortic valve replacement with the Evolut R, Evolut PRO, and Portico valves were included. Patients were divided according to the number of resheathing: no resheathing, single resheathing (SR), and MR. The primary end point was device success. Secondary outcomes included procedural complications, early safety events, and 1-year mortality. In 1026 patients, the proportion who required SR and MR was 23.9% and 9.3%, respectively. MR was predicted by the use of Portico and moderate/severe aortic regurgitation at baseline (both with P<0.01). Patients undergoing MR had less device success (no resheathing=89.9%, SR=89.8%, and MR=80%; P=0.01), driven by more need for a second prosthesis and device embolization. At 30 days, there were no differences in safety events. At 1 year, more deaths occurred with MR (no resheathing=10.5%, SR=8.0%, and MR=18.8%; P=0.014). After adjusting for baseline differences and center experience by annual volume, MR associated with less device success (odds ratio, 0.42; P=0.003) and increased 1-year mortality (hazard ratio, 2.06; P=0.01). When including only the Evolut R/PRO cases (N=837), MR continued to have less device success (P<0.001) and a trend toward increased mortality (P=0.05). Conclusions Repositioning a self-expanding valve is used in a third of patients, being multiple in ≈10%. MR, but not SR, was associated with more device failure and higher 1-year mortality, regardless of the type of valve implanted.


Assuntos
Substituição da Valva Aórtica Transcateter , Catéteres , Humanos , Incidência , Razão de Chances , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Cardiorenal Med ; 11(4): 166-173, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34261063

RESUMO

BACKGROUND: Acute kidney injury (AKI) has shown to adversely affect outcomes in patients undergoing transcutaneous aortic valve replacement (TAVR), and its correct risk estimation may interfere in procedural planning and strategies. The aim of the study was to test and compare 6 scores in predicting AKI after TAVR. METHODS: We tested 6 scores (the contrast material limit score, volume-to-creatinine clearance ratio, ACEF, CR4EATME3AD3, Mehran model A, and Mehran model B) in a total of 559 consecutive patients included in the Brazilian TAVR registry. RESULTS: All scores had a poor accuracy and calibration to predict the occurrence of AKI grade 1 or 2. All scores improved the accuracy of AKI risk prediction when stratified for AKI grade 2/3 and AKI grade 3 for all scores. The CR4EATME3AD3 was the best predictor of AKI stage 2/3 (AUC: 0.62; OR: 1.12; 95% CI 1.01-1.26; p = 0.04) and AKI stage 3 (AUC: 0.64; OR: 1.16; 95% CI 1.02-1.32; p = 0.02). Mehran models A and B were both good models for AKI stage 3 (AUC: 0.63; OR: 1.10; 95% CI 1.01-1.22; p = 0.05; and AUC: 0.62; OR: 1.10; 95% CI 1.00-1.21; p = 0.05, respectively). CONCLUSIONS: None of the current models demonstrated validity in detecting AKI when its lower grades were evaluated. CR4EATME3AD3 was the best score in predicting moderate to severe AKI after TAVR. These findings suggest that contrast-induced AKI may not be the only factor related to kidney injury after TAVR.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco
6.
Arq Bras Cardiol ; 116(6): 1059-1069, 2021 06.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34133587

RESUMO

BACKGROUND: Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. OBJECTIVE: To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. METHODS: Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. RESULTS: Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). CONCLUSIONS: Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


FUNDAMENTO: A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. OBJETIVO: Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. MÉTODOS: Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. RESULTADOS: RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). CONCLUSÕES: A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Brasil , Seguimentos , Humanos , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
7.
Arq. bras. cardiol ; 116(6): 1059-1069, Jun. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1278328

RESUMO

Resumo Fundamento A regurgitação mitral (RM) é prevalente em pacientes submetidos a implante transcateter de válvula aórtica (TAVI). Há algumas controvérsias sobre o impacto prognóstico da RM na sobrevida de pacientes submetidos a TAVI. Objetivo Examinar a relação entre TAVI e RM em uma população de pacientes do Registro Brasileiro de TAVI. Métodos Setecentos e noventa e cinco pacientes do Registro Brasileiro de TAVI foram divididos na linha de base, alta e acompanhamento de acordo com o grau da RM da maneira seguinte: ausente/leve (RMAL) ou moderado/grave (RMMG). Eles foram subsequentemente reagrupados de acordo com as mudanças imediatas e tardias na gravidade da RM após TAVI da maneira seguinte: RM sem mudança, melhora ou piora. Foram analisados os preditores e o impacto prognóstico na linha de base, bem como as mudanças na gravidade da RM. A significância estatística foi estabelecida em p < 0,05. Resultados RMMG basal estava presente em 19,3% dos pacientes e foi um preditor de aumento da mortalidade tardia. Imediatamente após o TAVI, 47,4% dos casos melhoraram para RMAL, previsto por uma pontuação mais alta da Society of Thoracic Surgeons e um grau mais alto de regurgitação aórtica basal. No acompanhamento, 9,2% dos casos de RMAL pioraram para RMMG, enquanto 36,8% dos casos de RMMG melhoraram para RMAL. Fração de ejeção do ventrículo esquerdo (FEVE) mais baixa na linha de base e melhora na FEVE durante o acompanhamento foram preditores de melhora da RM. Piora progressiva da RM no acompanhamento foi um preditor independente de maior mortalidade tardia após TAVI (p = 0,005). Conclusões A RMMG na linha de base é um preditor de mortalidade tardia após TAVI. FEVE mais baixa e melhora na FEVE durante o acompanhamento são preditores de melhora da RM após TAVI. A pior progressiva da gravidade da RM durante o acompanhamento é um preditor independente de mortalidade tardia; isto é um achado raro na literatura.


Abstract Background Mitral regurgitation (MR) is prevalent in patients undergoing transcatheter aortic valve implantation (TAVI). There are some controversies about the prognostic impact of MR in survival of TAVI patients. Objective To examine the relationship between TAVI and MR in a patient population from the Brazilian TAVI Registry. Methods Seven hundred and ninety-five patients from the Brazilian TAVI Registry were divided at baseline, discharge, and follow-up according to their MR grade as follows: absent/mild (AMMR) or moderate/severe (MSMR). They were subsequently regrouped according to their immediate and late changes in MR severity after TAVI as follows: no change, improved, or worsened MR. Predictors and prognostic impact on baseline as well as changes in MR severity were analyzed. Statistical significance was set at p < 0.05. Results Baseline MSMR was present in 19.3% of patients and was a predictor of increased late mortality. Immediately after TAVI, 47.4 % of cases improved to AMMR, predicted by a higher Society of Thoracic Surgeons score and a higher grade of baseline aortic regurgitation. Upon follow-up, 9.2% of cases of AMMR worsened to MSMR, whereas 36.8% of cases of MSMR improved to AMMR. Lower baseline left ventricular ejection fraction (LVEF) and improvement in LVEF at follow-up were predictors of MR improvement. Progressive worsening of MR upon follow-up was an independent predictor of higher late mortality after TAVI (p = 0.005). Conclusions Baseline MSMR predicts late mortality after TAVI. Lower LVEF and improved LVEF at follow-up predict MR improvement after TAVI. Progressive worsening of MR severity at follow-up is an independent predictor of late mortality, which is a rare finding in the literature.


Assuntos
Humanos , Estenose da Valva Aórtica/cirurgia , Implantação de Prótese , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Mitral/cirurgia , Valva Aórtica/cirurgia , Volume Sistólico , Índice de Gravidade de Doença , Brasil , Seguimentos , Função Ventricular Esquerda , Resultado do Tratamento
8.
J Invasive Cardiol ; 33(3): E200-E205, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33600354

RESUMO

BACKGROUND: In high-expertise transradial (TR) centers, the radiation exposure to patients during coronary angiography (CAG) is equivalent to transfemoral use. However, there is no definitive information during TR-CAG regarding the use of a single, dedicated catheter to impart less radiation exposure to patients. OBJECTIVE: We compare the radiation exposure to patients during right TR-CAG with Tiger II catheter (Terumo Interventional Systems) vs Judkins right (JR) 4.0/Judkins left (JL) 3.5 catheters (Cordis Corporation). METHODS: This multicenter, randomized, and prospective trial included 180 patients submitted to right TR-CAG, with the primary objective of observing radiation exposure to patients through the measurement of fluoroscopy time, air kerma (AK), and dose-area product (DAP) using Tiger II (group 1) vs JR 4.0 and JL 3.5 Judkins catheters (group 2). Secondary outcomes included contrast volume usage and the need to use additional catheters to complete the procedure (the crossover technique). RESULTS: Group 1 demonstrated reduced fluoroscopy time (2.47 ± 1.05 minutes in group 1 vs 2.68 ± 1.26 minutes in group 2; P=.01) and non-significant reduction of AK (540.9 ± 225.3 mGy in group 1 vs 577.9 ± 240.1 mGy in group 2; P=.34) and DAP (3786.7 ± 1731.7 µGy•m² in group 1 vs 4058.0 ± 1735.4 µGy•m² in group 2; P=.12). Contrast volume usage (53.46 ± 10.09 mL in group 1 vs 55.98 ± 10.43 mL in group 2; P=.13) and the need for additional catheters (5.56% in group 1 vs 4.44% in group 2; P>.99) were similar between groups. CONCLUSION: The Tiger II catheter was able to reduce radiation exposure to patients submitted to TR-CAG through a significant reduction in fluoroscopy time.


Assuntos
Cateterismo Cardíaco , Exposição à Radiação , Cateterismo Cardíaco/efeitos adversos , Catéteres , Angiografia Coronária/efeitos adversos , Vasos Coronários , Humanos , Estudos Prospectivos , Artéria Radial , Doses de Radiação , Exposição à Radiação/prevenção & controle
9.
Catheter Cardiovasc Interv ; 97(2): 259-264, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31922359

RESUMO

OBJECTIVES: This article aimed to compare the outcomes after hybrid revascularization with conventional coronary artery bypass grafting (CABG) surgery. BACKGROUND: The concept of hybrid coronary revascularization combines the advantages of CABG and percutaneous coronary intervention to improve the treatment of patients with complex multivessel disease. METHODS: The Myocardial hybrid revascularization versus coronary artERy bypass GraftING for complex triple-vessel disease-MERGING study is a pilot randomized trial that allocated 60 patients with complex triple-vessel disease to treatment with hybrid revascularization or conventional CABG (2:1 ratio). The primary outcome was the composite of all-cause death, myocardial infarction, stroke, or unplanned repeat revascularization at 2 years. RESULTS: Clinical and anatomical characteristics were similar between groups. After a mean follow-up of 802 ± 500 days, the primary endpoint rate was 19.3% in the hybrid arm and 5.9% in the CABG arm (p = NS). The incidence of unplanned revascularization increased over time in both groups, reaching 14.5 versus 5.9% in the hybrid and in the CABG groups, respectively (p = .4). Of note, in the hybrid group, there were no reinterventions driven by the occurrence of stent restenosis. CONCLUSIONS: Hybrid myocardial was feasible but associated with increasing rates of major adverse cardiovascular events during 2 years of clinical follow-up, while the control group treated with conventional surgery presented with low rates of complications during the same period. In conclusion, before more definitive data arise, hybrid revascularization should be applied with careful attention in practice, following a selective case-by-case indication.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Seguimentos , Humanos , Revascularização Miocárdica , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
11.
J Invasive Cardiol ; 32(10): 364-370, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32999089

RESUMO

OBJECTIVES: To compare severe complications related to radial access and those related to femoral access using vascular closure devices for patients undergoing primary percutaneous coronary intervention (PCI). BACKGROUND: Femoral artery access is still used for acute myocardial infarction management; studies comparing state-of-the-art radial and femoral techniques are required to minimize bias regarding the outcomes associated with operator preferences. METHODS: We performed a randomized study comparing radial access with a compression device and anatomic landmark-guided femoral access with a hemostatic vascular closure device. The severe complication rates related to the access site were assessed until hospital discharge. A meta- analysis including studies with comparable populations reporting severe bleeding and major adverse cardiovascular event rates was performed. RESULTS: A total of 250 patients were included who underwent PCI between January 2016 and February 2019. Mean age was 61.5 ± 12.2 years, 73.2% were men, and 28.4% had diabetes. There were no differences between groups or in vascular access-related severe complication rates (8.0% for femoral group vs 5.6% for radial group; P=.45). Although radial access was associated with decreased vascular complications related to the access site when compared with the femoral approach (relative risk [RR], 0.64; 95% confidence interval [CI], 0.43-0.95), the meta-analysis did not show an impact on severe bleeding (RR, 0.74; 95% CI, 0.37-1.46) or severe cardiovascular adverse events (RR, 0.69; 95% CI, 0.30-1.58). CONCLUSIONS: Compliance with femoral artery puncture techniques and routine use of a vascular closure device promoted low severe complication rates.


Assuntos
Intervenção Coronária Percutânea , Dispositivos de Oclusão Vascular , Idoso , Feminino , Artéria Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Artéria Radial/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
12.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33044863
13.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1148174
15.
Circ Cardiovasc Interv ; 12(11): e007938, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31694412

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Tomada de Decisão Clínica , Remoção de Dispositivo , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Feminino , Humanos , Incidência , Masculino , Seleção de Pacientes , Desenho de Prótese , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Assuntos
Sistema de Registros , Incidência , Endocardite , Substituição da Valva Aórtica Transcateter
17.
Rev. esp. cardiol. (Ed. impr.) ; 72(1): 21-29, ene. 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-182495

RESUMO

Introducción y objetivos: El daño renal agudo (DRA) ocurre con frecuencia tras el implante percutáneo de válvula aórtica (TAVI) y se asocia con una mayor mortalidad. Sin embargo, el impacto del DRA en la evolución a largo plazo continúa siendo controvertida. Por dicho motivo se evalúa el impacto del DRA el resultado a corto y largo plazo tras el TAVI usando los criterios Valve Academic Research Consortium 2. Métodos: Se incluyeron 794 pacientes consecutivos con estenosis aórtica grave en un registro multicéntrico brasileño. Para la identificación de los predictores de DRA se utilizó el análisis de regresión logística. La supervivencia a 4 años se determinó mediante las curvas de Kaplan-Meier y para determinar el impacto del DRA en la mortalidad entre los supervivientes a 12 meses se usó un análisis de punto de referencia ajustado. Resultados: La incidencia de DRA tras el TAVI fue del 18%. Los predictores independientes de DRA fueron: edad, diabetes mellitus, hemorragia mayor o amenazante para la vida y la malaposición valvular. El DRA se asoció independientemente con un riesgo mayor de muerte total (HR ajustada = 2,8; IC95%, 2,0-3,9; p < 0,001) y cardiovascular (HR ajustada = 2,9; IC95%, 1,9-4,4; p < 0,001) durante el periodo de seguimiento completo. Sin embargo, cuando se consideró solo los supervivientes a 12 meses, no hubo diferencias en ambos objetivos clínicos (HR ajustada = 1,2; IC95%, 0,5-2,4; p = 0,71, y HR = 0,7; IC95%, 0,2-2,1; p = 0,57, respectivamente). Conclusiones: El DRA es una complicación frecuente tras el TAVI. La edad avanzada, la diabetes, la hemorragia mayor o amenazante para la vida y la malaposición valvular eran factores predictivos de DRA. El DRA se asoció con el pronóstico a corto y largo plazo, sin embargo, el impacto del DRA sobre la mortalidad se limitó al primer año tras el TAVI


Introduction and objectives: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI) and is associated with higher mortality. However, the impact of AKI on long-term outcomes remains controversial. Therefore, we sought to evaluate the impact of AKI on short- and long-term outcomes following TAVI using the Valve Academic Research Consortium 2 criteria. Methods: Consecutive patients (n = 794) with severe aortic stenosis who underwent TAVI were included in a multicenter Brazilian registry. Logistic regression analysis was used to identify predictors of AKI. Four-year outcomes were determined as Kaplan-Meier survival curves, and an adjusted landmark analysis was used to test the impact of AKI on mortality among survivors at 12 months. Results: The incidence of AKI after TAVI was 18%. Independent predictors of AKI were age, diabetes mellitus, major or life-threatening bleeding and valve malpositioning. Acute kidney injury was independently associated with higher risk of all-cause death (adjusted HR, 2.8; 95%CI, 2.0-3.9; P < .001) and cardiovascular mortality (adjusted HR, 2.9; 95%CI, 1.9-4.4; P < .001) over the entire follow-up period. However, when considering only survivors at 12 months, there was no difference in both clinical endpoints (adjusted HR, 1.2; 95%CI, 0.5-2.4; P = .71, and HR, 0.7; 95%CI, 0.2-2.1; P = .57, respectively). Conclusions: Acute kidney injury is a frequent complication after TAVI. Older age, diabetes, major or life-threatening bleeding, and valve malpositioning were independent predictors of AKI. Acute kidney injury is associated with worse short- and long-term outcomes. However, the major impact of AKI on mortality is limited to the first year after TAVI


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Injúria Renal Aguda/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Complicações Pós-Operatórias
18.
Rev Esp Cardiol (Engl Ed) ; 72(1): 21-29, 2019 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29358043

RESUMO

INTRODUCTION AND OBJECTIVES: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI) and is associated with higher mortality. However, the impact of AKI on long-term outcomes remains controversial. Therefore, we sought to evaluate the impact of AKI on short- and long-term outcomes following TAVI using the Valve Academic Research Consortium 2 criteria. METHODS: Consecutive patients (n = 794) with severe aortic stenosis who underwent TAVI were included in a multicenter Brazilian registry. Logistic regression analysis was used to identify predictors of AKI. Four-year outcomes were determined as Kaplan-Meier survival curves, and an adjusted landmark analysis was used to test the impact of AKI on mortality among survivors at 12 months. RESULTS: The incidence of AKI after TAVI was 18%. Independent predictors of AKI were age, diabetes mellitus, major or life-threatening bleeding and valve malpositioning. Acute kidney injury was independently associated with higher risk of all-cause death (adjusted HR, 2.8; 95%CI, 2.0-3.9; P < .001) and cardiovascular mortality (adjusted HR, 2.9; 95%CI, 1.9-4.4; P < .001) over the entire follow-up period. However, when considering only survivors at 12 months, there was no difference in both clinical endpoints (adjusted HR, 1.2; 95%CI, 0.5-2.4; P = .71, and HR, 0.7; 95%CI, 0.2-2.1; P = .57, respectively). CONCLUSIONS: Acute kidney injury is a frequent complication after TAVI. Older age, diabetes, major or life-threatening bleeding, and valve malpositioning were independent predictors of AKI. Acute kidney injury is associated with worse short- and long-term outcomes. However, the major impact of AKI on mortality is limited to the first year after TAVI.


Assuntos
Injúria Renal Aguda/epidemiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/etiologia , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
19.
Int. j. cardiovasc. sci. (Impr.) ; 30(4): f:299-l:306, jul.-ago 2017. tab, graf
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-846765

RESUMO

Fundamento: A técnica radial reduz a prevalência de complicações vasculares, sangramento grave e mortalidade quando cotejada à técnica femoral. Entretanto, esta ainda predomina como via de acesso preferencial para a efetivação de procedimentos coronários invasivos, requerendo a adoção de estratégias capazes de minimizar intercorrências. Objetivos: Comparar a sobrevida livre de eventos cardiovasculares adversos graves aos 12 meses de pacientes submetidos à estratégia intervencionista precoce pelo acesso radial ou femoral com dispositivo de oclusão vascular. Métodos: Estudo randomizado de não inferioridade envolvendo 240 pacientes com síndrome coronariana aguda sem supradesnível do segmento ST. A função de sobrevivência livre de morte, infarto agudo do miocárdio ou acidente vascular encefálico foi estimada pelo modelo de Kaplan-Meier e comparada utilizando-se o teste de log rank. Resultados: A taxa de complicações vasculares no sítio de punção arterial aos 30 dias foi de 12,5% no grupo Angio-Seal e de 13,3% no grupo radial (p = 1,000). A incidência de sangramento grave ou transfusão sanguínea aos 12 meses também não diferiu entre os grupos (2,5% versus 1,7%, p = 1,000). Não se observou diferença quanto à curva de sobrevida livre de eventos cardiovasculares adversos graves (90,8% versus 94,2%, p = 0,328). Conclusões: Não houve distinção entre as técnicas na sobrevida livre de eventos cardiovasculares adversos graves aos 12 meses de seguimento. Ensaios clínicos com maior poder estatístico são necessários para a validação desses achados


Background: The radial approach reduces the prevalence of vascular complications, major bleeding and mortality when compared to the femoral approach. However, the last still prevails as the preferred approach for the performance of invasive coronary procedures, requiring the adoption of strategies to minimize complications. Objectives: To compare the survival free of major adverse cardiovascular events at 12 months in patients undergoing early intervention strategy by the radial or femoral access with vascular closure device. Methods: Randomized non inferiority trial involving 240 non-ST-segment elevation acute coronary syndrome patients. The survival free of death, myocardial infarction or stroke was estimated by the Kaplan-Meier method and compared using the log rank test. Results: The 30-day rate of vascular complications in the arterial puncture site was 12.5% in the Angio-Seal group and 13.3% in the radial group (p = 1.000). The 12-month incidence of major bleeding or blood transfusion did not differ between groups (2.5% vs. 1.7%, p = 1.000). There was no difference in survival free of major adverse cardiovascular events (90.8% versus 94.2%, p = 0.328). Conclusions: There was no distinction between the techniques in survival free of major adverse cardiovascular events at 12 months of followup. Clinical trials with greater statistical power are needed to validate these findings


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artéria Radial/cirurgia , Artéria Femoral/cirurgia , Intervenção Coronária Percutânea/métodos , Dispositivos de Oclusão Vascular , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/fisiopatologia , Interpretação Estatística de Dados , Resultado do Tratamento , Isquemia Miocárdica/complicações , Hemorragia/complicações , Hemostasia
20.
Catheter Cardiovasc Interv ; 89(6): 976-982, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27514319

RESUMO

OBJECTIVES: To compare the radial versus femoral approach using Angio-Seal for the incidence of access site complications among non-ST-segment elevation acute coronary syndrome patients undergoing invasive strategy. BACKGROUND: Arterial access is a major site of complications after invasive coronary procedures. Vascular closure devices provide more comfort to patients decreasing time to hemostasis and need for bed rest. However, the inconsistency of data proving their safety limits their routine adoption as a strategy to prevent vascular complications. METHODS: Single-center non-inferiority trial where 240 patients were randomized to radial or femoral access using Angio-Seal. The primary objective was the occurrence of complications at the arterial puncture site until 30 days after the procedure. RESULTS: There were no baseline clinical differences between groups, except for a greater prevalence of female patients in the radial group (33.3 vs. 20.0%, P = 0.020). Hemostasis was achieved in the entire radial group with the use of TR Band and in 95% of the procedures in the femoral group with Angio-Seal (P = 0.029). Except for a higher incidence of asymptomatic arterial occlusion in the radial group, there were no differences among the other analyzed outcomes. According to the noninferiority test, the use of Angio-Seal was noninferior to the radial approach, considering the margin of 15% (12.5 vs. 13.3%, difference -0.83%, 95% CI -9.31 - 7.65, P for noninferiority <0.001). CONCLUSIONS: Angio-Seal seems noninferior in the incidence of access site complications at 30 days when compared with the radial approach. © 2016 Wiley Periodicals, Inc.


Assuntos
Síndrome Coronariana Aguda/terapia , Cateterismo Cardíaco/métodos , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/métodos , Artéria Radial , Dispositivos de Oclusão Vascular , Síndrome Coronariana Aguda/diagnóstico , Fatores Etários , Idoso , Brasil , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Feminino , Hemorragia/sangue , Hemorragia/etiologia , Hemostasia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Intervenção Coronária Percutânea/efeitos adversos , Punções , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...