Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(5 Pt 2): 056501, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12059719

RESUMO

Smith-Purcell radiation, generated when a beam of charged particles passes close to the surface of a diffraction grating, has been studied in the visible spectral range at wavelengths of 360 and 546 nm with the low emittance 855 MeV electron beam of the Mainz Microtron MAMI. The beam focused to a spot size of 4 microm (full width at half maximum) passed over optical diffraction gratings of echelle profiles with blaze angles of 0.8 degrees, 17.27 degrees, and 41.12 degrees and grating periods of 0.833 and 9.09 microm. Taking advantage of the specific emission characteristics of Smith-Purcell radiation a clear separation from background components, such as diffracted synchrotron radiation from upstream beam optical elements and transition radiation, was possible. The intensity scales with a modified Bessel function of the first kind as a function of the distance between electron beam and grating surface. Experimental radiation factors have been determined and compared with calculations on the basis of Van den Berg's theory [P.M. Van den Berg, J. Opt. Soc. Am. 63, 689 (1973)]. Fair agreement has been found for gratings with large blaze angles while the measurement with the shallow grating (blaze angle 0.8 degrees ) is at variance with this theory. Finally, the optimal operational parameters of a Smith-Purcell radiation source in view of already existing powerful undulator sources are discussed.

2.
Z Arztl Fortbild Qualitatssich ; 94(1): 71-7, 2000 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-10721168

RESUMO

The Medical Advisory Service of the Health Insurance in the area of the Northern Rhine (MDK Nordrhein) has set up an internal concept for quality management since 1998. This concept includes the installation and performance of quality circles. Staff members were internally qualified as "presenters". They worked out principles for quality circles of the MDK North Rhine which were implemented as binding basic rules by the managing conference of the MDK. The principles will be presented in detail.


Assuntos
Participação nas Decisões , Programas Nacionais de Saúde , Alemanha , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Gestão da Qualidade Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...