Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 513
Filtrar
2.
Diabetes Obes Metab ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38562018

RESUMO

AIMS: To establish which components of energy balance mediate the clinically significant weight loss demonstrated with use of cotadutide, a glucagon-like peptide-1 (GLP-1)/glucagon receptor dual agonist, in early-phase studies. MATERIALS AND METHODS: We conducted a phase 2a, single-centre, randomized, placebo-controlled trial in overweight and obese adults with type 2 diabetes. Following a 16-day single-blind placebo run-in, participants were randomized 2:1 to double-blind 42-day subcutaneous treatment with cotadutide (100-300 µg daily) or placebo. The primary outcome was percentage weight change. Secondary outcomes included change in energy intake (EI) and energy expenditure (EE). RESULTS: A total of 12 participants (63%) in the cotadutide group and seven (78%) in the placebo group completed the study. The mean (90% confidence interval [CI]) weight change was -4.0% (-4.9%, -3.1%) and -1.4% (-2.7%, -0.1%) for the cotadutide and placebo groups, respectively (p = 0.011). EI was lower with cotadutide versus placebo (-41.3% [-66.7, -15.9]; p = 0.011). Difference in EE (per kJ/kg lean body mass) for cotadutide versus placebo was 1.0% (90% CI -8.4, 10.4; p = 0.784), assessed by doubly labelled water, and -6.5% (90% CI -9.3, -3.7; p < 0.001), assessed by indirect calorimetry. CONCLUSION: Weight loss with cotadutide is primarily driven by reduced EI, with relatively small compensatory changes in EE.

3.
BMJ Open ; 14(4): e076613, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569710

RESUMO

OBJECTIVE: The COVID-19 pandemic accelerated changes to clinical research methodology, with clinical studies being carried out via online/remote means. This mixed-methods study aimed to identify which digital tools are currently used across all stages of clinical research by stakeholders in clinical, health and social care research and investigate their experience using digital tools. DESIGN: Two online surveys followed by semistructured interviews were conducted. Interviews were audiorecorded, transcribed and analysed thematically. SETTING, PARTICIPANTS: To explore the digital tools used since the pandemic, survey participants (researchers and related staff (n=41), research and development staff (n=25)), needed to have worked on clinical, health or social care research studies over the past 2 years (2020-2022) in an employing organisation based in the West Midlands region of England (due to funding from a regional clinical research network (CRN)). Survey participants had the opportunity to participate in an online qualitative interview to explore their experiences of digital tools in greater depth (n=8). RESULTS: Six themes were identified in the qualitative interviews: 'definition of a digital tool in clinical research'; 'impact of the COVID-19 pandemic'; 'perceived benefits/drawbacks of digital tools'; 'selection of a digital tool'; 'barriers and overcoming barriers' and 'future digital tool use'. The context of each theme is discussed, based on the interview results. CONCLUSIONS: Findings demonstrate how digital tools are becoming embedded in clinical research, as well as the breadth of tools used across different research stages. The majority of participants viewed the tools positively, noting their ability to enhance research efficiency. Several considerations were highlighted; concerns about digital exclusion; need for collaboration with digital expertise/clinical staff, research on tool effectiveness and recommendations to aid future tool selection. There is a need for the development of resources to help optimise the selection and use of appropriate digital tools for clinical research staff and participants.


Assuntos
COVID-19 , Pandemias , Humanos , Apoio Social , COVID-19/epidemiologia , Inglaterra , Projetos de Pesquisa
4.
J Diabetes Sci Technol ; : 19322968241242803, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613227

RESUMO

BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of diabetes over the 24-hour period. METHODS: We retrospectively analyzed eight weeks of data from 52 participants (adults with type 1 diabetes and adults with insulin-treated type 2 diabetes) recruited to two single-center randomized controlled studies using FCL insulin delivery during unrestricted-living conditions. Key outcomes were time spent in hypoglycemia <70 mg/dL and marked hyperglycemia >300 mg/dL by type of diabetes. RESULTS: The median percentage of time spent in hypoglycemia <70 mg/dL over the 24-hour period was lower for those with type 2 diabetes than for those with type 1 diabetes (median [interquartile range (IQR)] 0.43% [0.20-0.77] vs 0.86%, [0.54-1.46]; mean difference 0.46 percentage points [95% CI 0.23-0.70]; P < .001). Median percentage time in marked hyperglycemia >300 mg/dL was lower for those with type 2 diabetes than for those with type 1 diabetes (median [IQR] 1.8% [0.6-3.5] vs 9.3% [6.9-11.8]; mean difference 7.8 percentage points [95% CI 5.5-10.0]; P < .001). CONCLUSIONS: Using the FCL system, hypoglycemia and marked hyperglycemia exposure were lower in type 2 diabetes than in type 1 diabetes.

5.
Am J Surg Pathol ; 48(6): e43-e64, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38451836

RESUMO

Breast implant-associated anaplastic large cell lymphoma has been recognized as a distinct entity in the World Health Organization classification of hematolymphoid neoplasms. These neoplasms are causally related to textured implants that were used worldwide until recently. Consequently, there is an increased demand for processing periprosthetic capsules, adding new challenges for surgeons, clinicians, and pathologists. In the literature, the focus has been on breast implant-associated anaplastic large cell lymphoma; however, benign complications related to the placement of breast implants occur in up to 20% to 30% of patients. Imaging studies are helpful in assessing patients with breast implants for evidence of implant rupture, changes in tissues surrounding the implants, or regional lymphadenopathy related to breast implants, but pathologic examination is often required. In this review, we couple our experience with a review of the literature to describe a range of benign lesions associated with breast implants that can be associated with different clinical presentations or pathogenesis and that may require different diagnostic approaches. We illustrate the spectrum of the most common of these benign disorders, highlighting their clinical, imaging, gross, and microscopic features. Finally, we propose a systematic approach for the diagnosis and handling of breast implant specimens in general.


Assuntos
Implante Mamário , Implantes de Mama , Linfoma Anaplásico de Células Grandes , Humanos , Implantes de Mama/efeitos adversos , Feminino , Linfoma Anaplásico de Células Grandes/patologia , Linfoma Anaplásico de Células Grandes/etiologia , Implante Mamário/efeitos adversos , Implante Mamário/instrumentação , Valor Preditivo dos Testes , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Relevância Clínica
6.
Diabetologia ; 67(6): 995-1008, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517484

RESUMO

AIMS/HYPOTHESIS: Type 1 diabetes is an heterogenous condition. Characterising factors explaining differences in an individual's clinical course and treatment response will have important clinical and research implications. Our aim was to explore type 1 diabetes heterogeneity, as assessed by clinical characteristics, autoantibodies, beta cell function and glycaemic outcomes, during the first 12 months from diagnosis, and how it relates to age at diagnosis. METHODS: Data were collected from the large INNODIA cohort of individuals (aged 1.0-45.0 years) newly diagnosed with type 1 diabetes, followed 3 monthly, to assess clinical characteristics, C-peptide, HbA1c and diabetes-associated antibodies, and their changes, during the first 12 months from diagnosis, across three age groups: <10 years; 10-17 years; and ≥18 years. RESULTS: The study population included 649 individuals (57.3% male; age 12.1±8.3 years), 96.9% of whom were positive for one or more diabetes-related antibodies. Baseline (IQR) fasting C-peptide was 242.0 (139.0-382.0) pmol/l (AUC 749.3 [466.2-1106.1] pmol/l × min), with levels increasing with age (p<0.001). Over time, C-peptide remained lower in participants aged <10 years but it declined in all age groups. In parallel, glucose levels progressively increased. Lower baseline fasting C-peptide, BMI SD score and presence of diabetic ketoacidosis at diagnosis were associated with lower stimulated C-peptide over time. HbA1c decreased during the first 3 months (p<0.001), whereas insulin requirement increased from 3 months post diagnosis (p<0.001). CONCLUSIONS/INTERPRETATION: In this large cohort with newly diagnosed type 1 diabetes, we identified age-related differences in clinical and biochemical variables. Of note, C-peptide was lower in younger children but there were no main age differences in its rate of decline.


Assuntos
Autoanticorpos , Peptídeo C , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Humanos , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Adolescente , Criança , Masculino , Feminino , Peptídeo C/sangue , Adulto , Adulto Jovem , Pré-Escolar , Autoanticorpos/sangue , Hemoglobinas Glicadas/metabolismo , Glicemia/metabolismo , Estudos de Coortes , Lactente , Europa (Continente)/epidemiologia , Pessoa de Meia-Idade , Células Secretoras de Insulina/metabolismo
7.
Diabetes Technol Ther ; 26(4): 211-221, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426909

RESUMO

Introduction: The Closing the Loop in Adults With Type 1 Diabetes (CLEAR) randomized crossover study compared a novel fully closed-loop insulin delivery system with no carbohydrate entry or mealtime bolusing (CamAPS HX), with standard insulin pump therapy and glucose sensor in adults with type 1 diabetes and suboptimal glycemic outcomes. This qualitative substudy aimed to understand the psychosocial impact of using the fully automated system. Materials and Methods: Adults participating in the CLEAR study were invited to take part in a virtual semistructured interview after they had completed 8 weeks using the fully closed-loop system. Recruitment continued until there was adequate representation and data saturation occurred. Interviews were anonymized and transcribed for in-depth thematic analysis using an inductive-deductive approach. Study participants were also asked to complete questionnaires assessing diabetes distress, hypoglycemia confidence, and closed-loop treatment satisfaction. Results: Eleven participants (eight male and three female; age range 26-66 years) were interviewed. After an initial adjustment period, interviewees reported enjoying a reduction in diabetes burden, freed-up mental capacity, and improved mood. All were happy with overnight glycemic outcomes, with the majority reporting benefits on sleep. Although experiences of postprandial glucose outcomes varied, all found mealtimes easier and less stressful, particularly when eating out. Negatives raised by participants predominantly related to the insulin pump hardware, but some also reported increased snacking and challenges around resuming carbohydrate counting at trial closeout. Conclusions: In adults with type 1 diabetes, use of a fully closed-loop insulin delivery system had significant quality-of-life benefits and provided a welcome break from the day-to-day demands of living with diabetes. Clinical Trial Registration: NCT04977908.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Glicemia , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Resultado do Tratamento , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
8.
Artigo em Inglês | MEDLINE | ID: mdl-38512385

RESUMO

Introduction: This study examined associations between hypoglycemia awareness status and hypoglycemia symptoms reported in real-time using the novel Hypoglycaemia-MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone application (app) among adults with insulin-treated type 1 (T1D) or type 2 diabetes (T2D). Methods: Adults who experienced at least one hypoglycemic episode in the previous 3 months were recruited to the Hypo-METRICS study. They prospectively reported hypoglycemia episodes using the app for 10 weeks. Any of eight hypoglycemia symptoms were considered present if intensity was rated between "A little bit" to "Very much" and absent if rated "Not at all." Associations between hypoglycemia awareness (as defined by Gold score) and hypoglycemia symptoms were modeled using mixed-effects binary logistic regression, adjusting for glucose monitoring method and diabetes duration. Results: Of 531 participants (48% T1D, 52% T2D), 45% were women, 91% white, and 59% used Flash or continuous glucose monitoring. Impaired awareness of hypoglycemia (IAH) was associated with lower odds of reporting autonomic symptoms than normal awareness of hypoglycemia (NAH) (T1D odds ratio [OR] 0.43 [95% confidence interval {CI} 0.25-0.73], P = 0.002); T2D OR 0.51 [95% CI 0.26-0.99], P = 0.048), with no differences in neuroglycopenic symptoms. In T1D, relative to NAH, IAH was associated with higher odds of reporting autonomic symptoms at a glucose concentration <54 than >70 mg/dL (OR 2.18 [95% CI 1.21-3.94], P = 0.010). Conclusion: The Hypo-METRICS app is sensitive to differences in hypoglycemia symptoms according to hypoglycemia awareness in both diabetes types. Given its high ecological validity and low recall bias, the app may be a useful tool in research and clinical settings. The clinical trial registration number is NCT04304963.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38386436

RESUMO

Introduction: Nocturnal hypoglycemia is generally calculated between 00:00 and 06:00. However, those hours may not accurately reflect sleeping patterns and it is unknown whether this leads to bias. We therefore compared hypoglycemia rates while asleep with those of clock-based nocturnal hypoglycemia in adults with type 1 diabetes (T1D) or insulin-treated type 2 diabetes (T2D). Methods: Participants from the Hypo-METRICS study wore a blinded continuous glucose monitor and a Fitbit Charge 4 activity monitor for 10 weeks. They recorded details of episodes of hypoglycemia using a smartphone app. Sensor-detected hypoglycemia (SDH) and person-reported hypoglycemia (PRH) were categorized as nocturnal (00:00-06:00 h) versus diurnal and while asleep versus awake defined by Fitbit sleeping intervals. Paired-sample Wilcoxon tests were used to examine the differences in hypoglycemia rates. Results: A total of 574 participants [47% T1D, 45% women, 89% white, median (interquartile range) age 56 (45-66) years, and hemoglobin A1c 7.3% (6.8-8.0)] were included. Median sleep duration was 6.1 h (5.2-6.8), bedtime and waking time ∼23:30 and 07:30, respectively. There were higher median weekly rates of SDH and PRH while asleep than clock-based nocturnal SDH and PRH among people with T1D, especially for SDH <70 mg/dL (1.7 vs. 1.4, P < 0.001). Higher weekly rates of SDH while asleep than nocturnal SDH were found among people with T2D, especially for SDH <70 mg/dL (0.8 vs. 0.7, P < 0.001). Conclusion: Using 00:00 to 06:00 as a proxy for sleeping hours may underestimate hypoglycemia while asleep. Future hypoglycemia research should consider the use of sleep trackers to record sleep and reflect hypoglycemia while asleep more accurately. The trial registration number is NCT04304963.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38315506

RESUMO

Objective: To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. Research Design and Methods: We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range. It was approved by independent research ethics committees. Results: Two trials with 8 weeks of data from 51 adults with type 1 diabetes were analyzed and 7137 eligible meals were included. During Lyumjev compared with insulin lispro, iAUC-2h and iAUC-4h were significantly decreased following breakfast (mean difference 92 mmol/L per 2 h (95% confidence interval [CI]: 56 to 127); P < 0.001 and 151 mmol/L per 4 h (95% CI: 74 to 229); P < 0.001, respectively) and the evening meal (P < 0.001 and P = 0.011, respectively). Mean time in target range (3.9-10.0 mmol/L) for 4 h postprandially significantly increased during Lyumjev with a mean difference of 6.7 percentage points (95% CI: 3.3 to 10) and 5.7 percentage points (95% CI: 1.4 to 9.9) for breakfast and evening meal, respectively. In contrast, there were no significant differences in iAUC-2h, iAUC-4h, and the other measures of postprandial glucose control between insulin aspart and Fiasp during breakfast, lunch, and evening meal (P > 0.05). Conclusion: The use of Lyumjev with CamAPS FX closed-loop system improved postprandial glucose excursions compared with insulin lispro, while the use of Fiasp did not provide any advantage compared with insulin aspart. Clinical Trial Registration numbers: NCT04055480, NCT05257460.

11.
Acta Diabetol ; 61(5): 623-633, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376580

RESUMO

AIM: The sympathetic nervous and hormonal counterregulatory responses to hypoglycaemia differ between people with type 1 and type 2 diabetes and may change along the course of diabetes, but have not been directly compared. We aimed to compare counterregulatory hormone and symptom responses to hypoglycaemia between people with type 1 diabetes, insulin-treated type 2 diabetes and controls without diabetes, using a standardised hyperinsulinaemic-hypoglycaemic clamp. MATERIALS: We included 47 people with type 1 diabetes, 15 with insulin-treated type 2 diabetes, and 32 controls without diabetes. Controls were matched according to age and sex to the people with type 1 diabetes or with type 2 diabetes. All participants underwent a hyperinsulinaemic-euglycaemic-(5.2 ± 0.4 mmol/L)-hypoglycaemic-(2.8 ± 0.13 mmol/L)-clamp. RESULTS: The glucagon response was lower in people with type 1 diabetes (9.4 ± 0.8 pmol/L, 8.0 [7.0-10.0]) compared to type 2 diabetes (23.7 ± 3.7 pmol/L, 18.0 [12.0-28.0], p < 0.001) and controls (30.6 ± 4.7, 25.5 [17.8-35.8] pmol/L, p < 0.001). The adrenaline response was lower in type 1 diabetes (1.7 ± 0.2, 1.6 [1.3-5.2] nmol/L) compared to type 2 diabetes (3.4 ± 0.7, 2.6 [1.3-5.2] nmol/L, p = 0.001) and controls (2.7 ± 0.4, 2.8 [1.4-3.9] nmol/L, p = 0.012). Growth hormone was lower in people with type 2 diabetes than in type 1 diabetes, at baseline (3.4 ± 1.6 vs 7.7 ± 1.3 mU/L, p = 0.042) and during hypoglycaemia (24.7 ± 7.1 vs 62.4 ± 5.8 mU/L, p = 0.001). People with 1 diabetes had lower overall symptom responses than people with type 2 diabetes (45.3 ± 2.7 vs 58.7 ± 6.4, p = 0.018), driven by a lower neuroglycopenic score (27.4 ± 1.8 vs 36.7 ± 4.2, p = 0.012). CONCLUSION: Acute counterregulatory hormone and symptom responses to experimental hypoglycaemia are lower in people with type 1 diabetes than in those with long-standing insulin-treated type 2 diabetes and controls.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glucagon , Técnica Clamp de Glucose , Hipoglicemia , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/metabolismo , Masculino , Feminino , Hipoglicemia/induzido quimicamente , Hipoglicemia/etiologia , Pessoa de Meia-Idade , Adulto , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/efeitos adversos , Glicemia/metabolismo , Epinefrina/sangue , Idoso , Estudos de Casos e Controles
12.
JAMA ; 331(5): 444-445, 2024 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-38319338
14.
Diabet Med ; 41(3): e15232, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37750427

RESUMO

OBJECTIVE: We previously showed that intermittently scanned continuous glucose monitoring (isCGM) reduces HbA1c at 24 weeks compared with self-monitoring of blood glucose with finger pricking (SMBG) in adults with type 1 diabetes and high HbA1c levels (58-97 mmol/mol [7.5%-11%]). We aim to assess the economic impact of isCGM compared with SMBG. METHODS: Participant-level baseline and follow-up health status (EQ-5D-5L) and within-trial healthcare resource-use data were collected. Quality-adjusted life-years (QALYs) were derived at 24 weeks, adjusting for baseline EQ-5D-5L. Participant-level costs were generated. Using the IQVIA CORE Diabetes Model, economic analysis was performed from the National Health Service perspective over a lifetime horizon, discounted at 3.5%. RESULTS: Within-trial EQ-5D-5L showed non-significant adjusted incremental QALY gain of 0.006 (95% CI: -0.007 to 0.019) for isCGM compared with SMBG and an adjusted cost increase of £548 (95% CI: 381-714) per participant. The lifetime projected incremental cost (95% CI) of isCGM was £1954 (-5108 to 8904) with an incremental QALY (95% CI) gain of 0.436 (0.195-0.652) resulting in an incremental cost-per-QALY of £4477. In all subgroups, isCGM had an incremental cost-per-QALY better than £20,000 compared with SMBG; for people with baseline HbA1c >75 mmol/mol (9.0%), it was cost-saving. Sensitivity analysis suggested that isCGM remains cost-effective if its effectiveness lasts for at least 7 years. CONCLUSION: While isCGM is associated with increased short-term costs, compared with SMBG, its benefits in lowering HbA1c will lead to sufficient long-term health-gains and cost-savings to justify costs, so long as the effect lasts into the medium term.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/terapia , Glicemia , Análise Custo-Benefício , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas , Monitoramento Contínuo da Glicose , Medicina Estatal , Inglaterra/epidemiologia , Hipoglicemiantes
15.
Diabet Med ; 41(3): e15249, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37897112

RESUMO

AIMS: The FLASH-UK trial showed lower HbA1c with intermittently scanned continuous glucose monitoring (isCGM), as compared with self monitoring of blood glucose (SMBG), in adults with type 1 diabetes and HbA1c ≥58 mmol/mol (≥7.5%). Here, we present results from the pre-specified subgroup analysis for the 24-week HbA1c (primary outcome) and selected sensor-based secondary outcomes. METHODS: This was a multi-centre, parallel-design, randomised controlled trial. The difference in treatment effect between subgroups (baseline HbA1c [≤75 vs. >75 mmol/mol] [≤9.0 vs >9.0%], treatment modality [pump vs injections], prior participation in structured education, age, educational level, impaired awareness of hypoglycaemia, deprivation index quintile sex, ethnic group and Patient Health Questionnaire-9 [PHQ-9] detected depression category) were evaluated. RESULTS: One hundred fifty-six participants (females 44%, mean [SD] baseline HbA1c 71 [9] mmol/mol 8.6 [0.8%], age 44 [15]) were randomly assigned, in a 1:1 ratio to isCGM (n = 78) or SMBG (n = 78). The mean (SD) baseline HbA1c (%) was 8.7 (0.9) in the isCGM group and 8.5 (0.8) in the SMBG group, lowering to 7.9 (0.8) versus 8.3 (0.9), respectively, at 24 weeks (adjusted mean difference -0.5, 95% confidence interval [CI] -0.7 to -0.3; p < 0.001]. For HbA1c, there was no impact of treatment modality, prior participation in structured education, deprivation index quintile, sex or baseline depression category. The between-group difference in HbA1c was larger for younger people (a reduction of 2.7 [95% CI 0.3-5.0; p = 0.028] mmol/mol for every additional 15 years of age). Those with HbA1c 76-97 mmol/mol (>9.0%-11.0%) had a marginally non-significant higher reduction in HbA1c of 8.4 mmol/mol (3.3-13.5) compared to 3.1 (0.3-6.0) in those with HbA1c 58-75 mmol/mol (p = 0.08). For 'Time in range' (% 3.9-10 mmol/L), the difference was larger for those with at least a bachelor's degree. For 'Time below range' (% <3.9 mmol/L), the difference was larger for those using injections, older people and those with less than bachelor's degree. CONCLUSIONS: Intermittently scanned continuous glucose monitoring is generally effective across a range of baseline characteristics.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Feminino , Humanos , Idoso , Glicemia/análise , Hemoglobinas Glicadas , Automonitorização da Glicemia/métodos , Monitoramento Contínuo da Glicose , Reino Unido , Hipoglicemiantes/uso terapêutico
16.
Am J Surg Pathol ; 48(2): 221-229, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38050371

RESUMO

Germline and somatic pathogenic variants (PVs) in DICER1 , encoding a miRNA biogenesis protein, are associated with a wide variety of highly specific pathologic entities. The lung tumors pleuropulmonary blastoma, pulmonary blastoma (PB), and well-differentiated fetal lung adenocarcinoma (WDFLAC) are all known to harbor DICER1 biallelic variants (loss of function and/or somatic hotspot missense mutations), and all share pathologic features reminiscent of the immature lung. However, the role of DICER1 PVs in non-small cell lung cancer (NSCLC) is relatively unknown. Here, we aimed to establish the spectrum of lung pathologies associated with DICER1 hotspot PVs and to compare the mutational landscape of DICER1 -mutated NSCLC with and without hotspots. We queried DNA sequencing data from 12,146 NSCLCs featuring somatic DICER1 variants. 235 (1.9%) cases harboring ≥ 1 DICER1 PV were found and 9/235 (3.8%) were DICER1 hotspot-positive cases. Histologic review of DICER1 hotspot-positive cases showed that all but one tumor were classified as within the histologic spectrum of PB/WDFLAC, whereas all the DICER1 non-hotspot double variants were classified as lung adenocarcinomas, not otherwise specified. Comparison between the mutational landscape of DICER1 hotspot-positive and hotspot-negative cases revealed a higher frequency of CTNNB1 mutations in the hotspot-positive cases (5/9 vs. 2/225; P <0.00001). We conclude that DICER1 somatic hotspots are not implicated in the most common forms of NSCLC but rather select for morphologic features of lung tumor types such as PB and WDFLAC. As a corollary, cases showing this tumor morphology should undergo testing for DICER1 variants, and if positive, genetic counseling should be considered.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , MicroRNAs , Blastoma Pulmonar , Humanos , Recém-Nascido , Carcinoma Pulmonar de Células não Pequenas/genética , Neoplasias Pulmonares/genética , Mutação , MicroRNAs/genética , Blastoma Pulmonar/genética , Ribonuclease III/genética , Mutação em Linhagem Germinativa , RNA Helicases DEAD-box/genética
17.
Diabetologia ; 67(2): 371-391, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38017352

RESUMO

AIMS/HYPOTHESIS: Repeated exposures to insulin-induced hypoglycaemia in people with diabetes progressively impairs the counterregulatory response (CRR) that restores normoglycaemia. This defect is characterised by reduced secretion of glucagon and other counterregulatory hormones. Evidence indicates that glucose-responsive neurons located in the hypothalamus orchestrate the CRR. Here, we aimed to identify the changes in hypothalamic gene and protein expression that underlie impaired CRR in a mouse model of defective CRR. METHODS: High-fat-diet fed and low-dose streptozocin-treated C57BL/6N mice were exposed to one (acute hypoglycaemia [AH]) or multiple (recurrent hypoglycaemia [RH]) insulin-induced hypoglycaemic episodes and plasma glucagon levels were measured. Single-nuclei RNA-seq (snRNA-seq) data were obtained from the hypothalamus and cortex of mice exposed to AH and RH. Proteomic data were obtained from hypothalamic synaptosomal fractions. RESULTS: The final insulin injection resulted in similar plasma glucose levels in the RH group and AH groups, but glucagon secretion was significantly lower in the RH group (AH: 94.5±9.2 ng/l [n=33]; RH: 59.0±4.8 ng/l [n=37]; p<0.001). Analysis of snRNA-seq data revealed similar proportions of hypothalamic cell subpopulations in the AH- and RH-exposed mice. Changes in transcriptional profiles were found in all cell types analysed. In neurons from RH-exposed mice, we observed a significant decrease in expression of Avp, Pmch and Pcsk1n, and the most overexpressed gene was Kcnq1ot1, as compared with AH-exposed mice. Gene ontology analysis of differentially expressed genes (DEGs) indicated a coordinated decrease in many oxidative phosphorylation genes and reduced expression of vacuolar H+- and Na+/K+-ATPases; these observations were in large part confirmed in the proteomic analysis of synaptosomal fractions. Compared with AH-exposed mice, oligodendrocytes from RH-exposed mice had major changes in gene expression that suggested reduced myelin formation. In astrocytes from RH-exposed mice, DEGs indicated reduced capacity for neurotransmitters scavenging in tripartite synapses as compared with astrocytes from AH-exposed mice. In addition, in neurons and astrocytes, multiple changes in gene expression suggested increased amyloid beta (Aß) production and stability. The snRNA-seq analysis of the cortex showed that the adaptation to RH involved different biological processes from those seen in the hypothalamus. CONCLUSIONS/INTERPRETATION: The present study provides a model of defective counterregulation in a mouse model of type 2 diabetes. It shows that repeated hypoglycaemic episodes induce multiple defects affecting all hypothalamic cell types and their interactions, indicative of impaired neuronal network signalling and dysegulated hypoglycaemia sensing, and displaying features of neurodegenerative diseases. It also shows that repeated hypoglycaemia leads to specific molecular adaptation in the hypothalamus when compared with the cortex. DATA AVAILABILITY: The transcriptomic dataset is available via the GEO ( http://www.ncbi.nlm.nih.gov/geo/ ), using the accession no. GSE226277. The proteomic dataset is available via the ProteomeXchange data repository ( http://www.proteomexchange.org ), using the accession no. PXD040183.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Camundongos , Animais , Glucagon/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Peptídeos beta-Amiloides , Proteômica , Camundongos Endogâmicos C57BL , Hipoglicemia/tratamento farmacológico , Insulina/metabolismo , Hipotálamo/metabolismo , Hipoglicemiantes/efeitos adversos , Perfilação da Expressão Gênica , RNA Nuclear Pequeno/metabolismo , Glicemia/metabolismo
19.
Reprod Sci ; 31(5): 1179-1189, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133768

RESUMO

Cerebral palsy (CP) has been recognized as a group of neurologic disorders with varying etiologies and ontogenies. While a percentage of CP cases arises during labor, the expanded use of electronic fetal monitoring (EFM) to include prevention of CP has resulted in decades of vastly increased interventions that have not significantly reduced the incidence of CP for infants born at term in the USA. Litigation alleging that poor obstetrical practice caused CP in most of these affected children has led to contentious arguments regarding the actual etiologies of this condition and often resulted in substantial monetary awards for plaintiffs. Recent advances in genetic testing using whole exome sequencing have revealed that at least one-third of CP cases in term infants are genetic in origin and therefore not labor-related. Here, we will present and discuss previous attempts to sort out contributing etiologies and ontogenies of CP, and how these newer diagnostic techniques are rapidly improving our ability to better detect and understand such cases. In light of these developments, we present our vision for an overarching spectrum for proper categorization of CP cases into that the following groups: (1) those begun at conception from genetic causes (nonpreventable); (2) those stemming from adverse antenatal/pre-labor events (possibly preventable with heightened antepartum assessment); (3) Those arising from intrapartum events (potentially preventable by earlier interventions); (4) Those occurring shortly after birth (possibly preventable with closer neonatal monitoring); (5) Those that appear later in the postnatal period from non-labor-related causes such as untreated infections or postnatal intracranial hemorrhages.


Assuntos
Paralisia Cerebral , Humanos , Paralisia Cerebral/etiologia , Paralisia Cerebral/diagnóstico , Paralisia Cerebral/epidemiologia , Paralisia Cerebral/prevenção & controle , Paralisia Cerebral/genética , Gravidez , Feminino , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...