1.
Sci Rep ; 4: 4740, 2014 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-24751935

RESUMO

Cortical mapping of cognitive function during infancy is poorly understood in low-income countries due to the lack of transportable neuroimaging methods. We have successfully piloted functional near infrared spectroscopy (fNIRS) as a neuroimaging tool in rural Gambia. Four-to-eight month old infants watched videos of Gambian adults perform social movements, while haemodynamic responses were recorded using fNIRS. We found distinct regions of the posterior superior temporal and inferior frontal cortex that evidenced either visual-social activation or vocally selective activation (vocal > non-vocal). The patterns of selective cortical activation in Gambian infants replicated those observed within similar aged infants in the UK. These are the first reported data on the measurement of localized functional brain activity in young infants in Africa and demonstrate the potential that fNIRS offers for field-based neuroimaging research of cognitive function in resource-poor rural communities.


Assuntos
Cognição/fisiologia , Vigilância em Saúde Pública , Espectroscopia de Luz Próxima ao Infravermelho , África , Córtex Cerebral/fisiologia , Feminino , Hemodinâmica , Humanos , Lactente , Masculino , Neuroimagem , Oxiemoglobinas/metabolismo , Saúde da População Rural , Espectroscopia de Luz Próxima ao Infravermelho/métodos
2.
Adv Exp Med Biol ; 812: 263-269, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24729242

RESUMO

We used optical topography (OT) to investigate cognitive function in infants in rural Gambia. Images of changes in oxyhaemoglobin and deoxyhaemoglobin concentrations were reconstructed using a multispectral algorithm which uses the finite element method (FEM) to model the propagation of light through scattering tissue using the diffusion equation. High quality OT data enabled us to reconstruct images with robust representation of haemodynamic changes. OT is a feasible neuroimage technology for this resource-poor setting.


Assuntos
Encéfalo/fisiologia , Algoritmos , Análise de Elementos Finitos , Gâmbia , Humanos , Lactente , Espectroscopia de Luz Próxima ao Infravermelho
3.
Med Eng Phys ; 35(11): 1692-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23706504

RESUMO

We have designed, built and successfully tested a prototype portable and wireless near-infrared spectroscopy system. It takes forward the well-established series of NIRO spectroscopy instruments made by Hamamatsu Photonics (Hamamatsu City, Japan). It uses an identical optical probe, and has a data acquisition rate of 10 Hz. It illuminates the tissue with laser diode sources at 3 wavelengths of 775, 810 and 850 nm, and detects the reflected light with 2 silicon photodiode detectors at 2 different separations, enabling spatially resolved spectroscopy to be performed. We have tested it with both in vitro and in vivo experiments to establish its basic functionality for use in studies of both brain and muscle.


Assuntos
Encéfalo , Músculos , Espectrofotometria Infravermelho/instrumentação , Tecnologia sem Fio/instrumentação , Desenho de Equipamento , Humanos , Masculino , Reprodutibilidade dos Testes , Manobra de Valsalva , Caminhada/fisiologia
4.
Neuroimage ; 55(4): 1610-6, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21255658

RESUMO

We describe a series of novel simultaneous EEG and diffuse optical imaging studies of newborn infants. These experiments provide evidence of large, transient haemodynamic events which occur repeatedly and consistently within and across several infants with neurological damage, all of whom were diagnosed with seizures. A simple but independent process of rejecting artifacts and identifying events within diffuse optical imaging data is described, and this process is applied to data from 4 neurologically damaged neonates and from 19 healthy, age-matched controls. This method results in the consistent identification of events in three out of four of the neurologically damaged infant group which are dominated by a slow (>30s) and significant increase in oxyhaemoglobin concentration, followed by a rapid and significant decrease before a slow return to baseline. No comparable events are found in any of our control data sets. The importance and physiological implications of our findings are discussed, as is the suitability of a combined EEG and diffuse optical imaging approach to the study and monitoring of neonatal brain injury.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiopatologia , Circulação Cerebrovascular , Diagnóstico por Computador/métodos , Eletroencefalografia/métodos , Nefelometria e Turbidimetria/métodos , Oxigênio/análise , Feminino , Humanos , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Rev Sci Instrum ; 81(9): 093706, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20886986

RESUMO

We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.


Assuntos
Fundo de Olho , Iluminação/métodos , Imagem Molecular/instrumentação , Semicondutores , Feminino , Humanos , Masculino , Análise Espectral
6.
Phys Med Biol ; 54(20): 6277-86, 2009 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-19794240

RESUMO

A solid dynamic phantom with tissue-like optical properties is presented, which contains seven discrete targets impregnated with thermochromic pigment located at different depths from the surface. Changes in absorption are obtained in response to localized heating of the targets, simulating haemodynamic changes occurring in the brain and other tissues. The depth sensitivity of a continuous wave optical topography system was assessed successfully using the phantom. Images of the targets have been reconstructed using a spatially variant regularization, and the determined spatial localization in the depth direction is shown to be accurate within an uncertainty of about 3 mm down to a depth of about 30 mm.


Assuntos
Encéfalo/patologia , Tomografia Óptica/métodos , Absorção , Algoritmos , Desenho de Equipamento , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Óptica e Fotônica , Imagens de Fantasmas , Polietileno/química , Software
7.
Phys Med Biol ; 54(18): N403-8, 2009 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-19687562

RESUMO

We describe a phantom for simultaneous electroencephalography (EEG) and near-infrared imaging which consists of a solid, optically turbid and electrically conducting interface enclosing a tissue-mimicking aqueous scattering solution. The interface provides an electrical contact impedance comparable to that of the human scalp while the phantom as a whole has optical properties and electrical conductivity equivalent to that of head tissue. The construction is described and our design is evaluated experimentally using an optically absorbing target which also provides an EEG-equivalent electric field source. The results of this simultaneous EEG and near-infrared imaging experiment are presented.


Assuntos
Materiais Biomiméticos , Mapeamento Encefálico/instrumentação , Eletroencefalografia/instrumentação , Nefelometria e Turbidimetria/instrumentação , Imagens de Fantasmas , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Desenho Assistido por Computador , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Raios Infravermelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Phys Med Biol ; 54(7): 2093-102, 2009 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-19287076

RESUMO

We present a novel probe design which enables simultaneous electroencephalography (EEG) and near-infrared (NIR) optical imaging to be performed in a manner which is easy to apply, allows for optimum co-registration of the two forms of data and maximizes the number of sensors which can be applied to a given area. Our probe design is evaluated using a dual-modality, tissue-mimicking phantom and by performing a simple functional activation study of the human motor cortex. We successfully acquired NIR optical and EEG data simultaneously for both our phantom and our human motor cortex experiments, clearly demonstrating the effectiveness and suitability of our 'opto-electrode'.


Assuntos
Eletroencefalografia/instrumentação , Raios Infravermelhos , Córtex Motor/fisiologia , Integração de Sistemas , Eletrodos , Desenho de Equipamento , Humanos , Masculino , Fibras Ópticas , Imagens de Fantasmas , Fatores de Tempo , Adulto Jovem
9.
Phys Med Biol ; 53(21): N407-13, 2008 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-18843169

RESUMO

An electrically-activated phantom for evaluating diffuse optical imaging systems has been designed based on an array of semiconductor diodes which are used to heat a thermochromic dye embedded in a solidified polyester resin with tissue-like optical properties. The array allows individual diodes to be addressed sequentially, thus simulating the movement of a small volume of contrasting optical absorption. Two designs of diode-array phantom are described and results of imaging experiments are presented.


Assuntos
Fenômenos Ópticos , Imagens de Fantasmas , Semicondutores , Absorção , Eletrodos , Semicondutores/instrumentação , Temperatura
10.
Phys Med Biol ; 53(2): 329-37, 2008 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-18184989

RESUMO

A novel design of solid dynamic phantom with tissue-like optical properties is presented, which contains variable regions of contrast which are activated electrically. Reversible changes in absorption are produced by localized heating of targets impregnated with thermochromic pigment. A portable, battery-operated prototype has been constructed, and its optical and temporal characteristics have been investigated. The phantom has been developed as a means of assessing the performance of diffuse optical imaging systems, such as those used to monitor haemodynamic changes in the brain and other tissues. Images of the phantom have been reconstructed using data acquired with a continuous wave optical topography system.


Assuntos
Imagens de Fantasmas , Tomografia Óptica/instrumentação , Imagem Corporal Total/instrumentação , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Tomografia Óptica/métodos , Imagem Corporal Total/métodos
11.
Med Eng Phys ; 29(4): 516-24, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-16919494

RESUMO

A prototype dialysis system for the treatment of premature babies has been designed, built and successfully tested. It can be used to treat babies who are suffering from renal failure or metabolic disorders. These patients are difficult or impossible to treat conventionally, due to their very small total blood volume (typically 40ml) and their intolerance to donated blood. There was a strong case for developing a dialysis system specifically designed for the treatment of such patients. The system is based on a manually operated device that had been previously developed. The method differs from conventional dialysis in several ways. Blood access to the patient is via a single venous catheter. Only a very small amount of blood is needed to prime the extracorporeal circuit--this can be as little as 6.8ml in the smallest patients. This compares very favourably with the volumes needed in conventional circuits, which are in the range of 15-40ml. This small priming volume means that donated blood is not needed to prime the circuit, which reduces the risks and complexity of the treatment. The clearance and ultrafiltration rates that can be achieved are independent of the rate that blood can be accessed from the patient, since the same blood passes back and forth through the dialyser several times. In vitro testing covered several areas of operation. The accuracy of the ultrafiltration process was established. The clearance rates that could be achieved were determined. The clearances that have been obtained experimentally with the new system are consistently above 40% of the mean blood flow rate through the system. The largest mean blood flow rate available is 5ml/min, so the maximum clearance is approximately 2ml/min. The maximum ultrafiltration rate that can be obtained is 50ml/h. The amount of damage caused to the blood by the system was found to be well within acceptable clinical limits. In vivo testing established the feasibility of using a computer algorithm to control the withdrawal of blood from the patient. The system has been used successfully to treat seven patients at the time of publication.


Assuntos
Injúria Renal Aguda/terapia , Doenças Metabólicas/terapia , Diálise Renal/instrumentação , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Diálise Renal/métodos
12.
Neuroimage ; 30(2): 521-8, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16246586

RESUMO

Optical tomography has been used to reconstruct three-dimensional images of the entire neonatal head during motor evoked responses. Data were successfully acquired during passive movement of each arm on four out of six infants examined, from which eight sets of bilateral images of hemodynamic parameters were reconstructed. Six out of the eight images showed the largest change in total hemoglobin in the region of the contralateral motor cortex. The mean distance between the peak response in the image and the estimated position of the contralateral motor cortex was 10.8 mm. These results suggest that optical tomography may provide an appropriate technique for non-invasive cot-side imaging of brain function.


Assuntos
Potencial Evocado Motor/fisiologia , Córtex Motor/fisiologia , Movimento/fisiologia , Tomografia/métodos , Algoritmos , Braço/fisiologia , Feminino , Lateralidade Funcional/fisiologia , Hemodinâmica/fisiologia , Hemoglobinas/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Masculino , Oxigênio/sangue
SELEÇÃO DE REFERÊNCIAS