Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 13(17)2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37685297

RESUMO

Ultra-high-frequency ultrasound (UHFUS) has a reported potential to differentiate between aganglionic and ganglionic bowel wall, referred to as histoanatomical differences. A good correlation between histoanatomy and UHFUS of the bowel wall has been proven. In order to perform more precise and objective histoanatomical morphometrics, the main research objective of this study was to develop a computer program for the assessment and automatic calculation of the histoanatomical morphometrics of the bowel wall in UHFUS images. A computer program for UHFUS diagnostics was developed and presented. A user interface was developed in close collaboration between pediatric surgeons and biomedical engineers, to enable interaction with UHFUS images. Images from ex vivo bowel wall samples of 23 children with recto-sigmoid Hirschsprung's disease were inserted. The program calculated both thickness and amplitudes (image whiteness) within different histoanatomical bowel wall layers. Two observers assessed the images using the program and the inter-observer variability was evaluated. There was an excellent agreement between observers, with an intraclass correlation coefficient range of 0.970-0.998. Bland-Altman plots showed flat and narrow distributions. The mean differences ranged from 0.005 to 0.016 mm in thickness and 0 to 0.7 in amplitude units, corresponding to 1.1-3.6% and 0.0-0.8% from the overall mean. The computer program enables and ensures objective, accurate and time-efficient measurements of histoanatomical thicknesses and amplitudes in UHFUS images of the bowel wall. The program can potentially be used for several bowel wall conditions, accelerating research within UHFUS diagnostics.

2.
Diagnostics (Basel) ; 13(8)2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37189490

RESUMO

Hirschsprung's disease (HD) is characterized by aganglionosis in the bowel wall, requiring resection. Ultra-high frequency ultrasound (UHFUS) imaging of the bowel wall has been suggested to be an instantaneous method of deciding resection length. The aim of this study was to validate UHFUS imaging of the bowel wall in children with HD by exploring the correlation and systematic differences between UHFUS and histopathology. Resected fresh bowel specimens of children 0-1 years old, operated on for rectosigmoid aganglionosis at a national HD center 2018-2021, were examined ex vivo with UHFUS center frequency 50 MHz. Aganglionosis and ganglionosis were confirmed by histopathological staining and immunohistochemistry. Histoanatomical layers of bowel wall in histopathological and UHFUS images, respectively, were outlined using MATLAB programs. Both histopathological and UHFUS images were available for 19 aganglionic and 18 ganglionic specimens. The thickness of muscularis interna correlated positively between histopathology and UHFUS in both aganglionosis (R = 0.651, p = 0.003) and ganglionosis (R = 0.534, p = 0.023). The muscularis interna was systematically thicker in histopathology than in UHFUS images in both aganglionosis (0.499 vs. 0.309 mm; p < 0.001) and ganglionosis (0.644 versus 0.556 mm; p = 0.003). Significant correlations and systematic differences between histopathological and UHFUS images support the hypothesis that UHFUS reproduces the histoanatomy of the bowel wall in HD accurately.

3.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37238152

RESUMO

It has been shown that ultra-high frequency (UHF) ultrasound applied to the external bowel wall can delineate the histo-anatomic layers in detail and distinguish normal bowel from aganglionosis. This would potentially reduce or lessen the need for biopsies that are currently mandatory for the diagnosis of Hirschsprung's disease. However, to our knowledge, no suitable rectal probes for such a use are on the market. The aim was to define the specifications of an UHF transrectal ultrasound probe (50 MHz center frequency) suitable for use in infants. Probe requirements according to patient anatomy, clinicians' requests, and biomedical engineering UHF prerequisites were collected within an expert group. Suitable probes on the market and in clinical use were reviewed. The requirements were transferred into the sketching of potential UHF ultrasound transrectal probes followed by their 3D prototype printing. Two prototypes were created and tested by five pediatric surgeons. The larger and straight 8 mm head and shaft probe was preferred as it facilitated stability, ease of anal insertion, and possible UHF technique including 128 piezoelectric elements in a linear array. We hereby present the procedure and considerations behind the development of a proposed new UHF transrectal pediatric probe. Such a device can open new possibilities for the diagnostics of pediatric anorectal conditions.

4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 194-197, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086230

RESUMO

Despite advances in MRI, the detection and characterisation of lymph nodes in rectal cancer remains complex, especially when assessing the response to neo-adjuvant treatment. An alternative approach is functional imaging, previously shown to aid characterization of cancer tissues. We report proof-of-concept of the novel technique Contrast-Enhanced Magneto-Motive Ultrasound (CE-MMUS) to recover information relating to local perfusion and lymphatic drainage, and interrogate tissue mechanical properties through magnetically induced tissue deformations. The feasibility of the proposed application was explored using a combination of pre-clinical ultrasound imaging and finite element analysis. First, contrast enhanced ultrasound imaging on one wild type mouse recorded lymphatic drainage of magnetic microbubbles after bolus injection. Second, preliminary CE-MMUS data were acquired as a proof of concept. Third, the magneto-mechanical interactions of a magnetic microbubble with an elastic solid were simulated using finite element software. Accumulation of magnetic microbubbles in the inguinal lymph node was verified using contrast enhanced ultrasound, with peak enhancement occurring 3.7 s post-injection. Preliminary CE-MMUS indicates the presence of magnetic contrast agent in the lymph node. The finite element analysis explores how the magnetic force is transferred to motion of the solid, which depends on elasticity and bubble radius, indicating an inverse relation with displacement. Combining magnetic microbubbles with MMUS could harness the advantages of both techniques, to provide perfusion information, robust lymph node delineation and characterisation based on mechanical properties. Clinical Relevance- Robust detection and characterisation of lymph nodes could be aided by visualising lymphatic drainage of magnetic microbubbles using contrast enhanced ultrasound imaging and magneto-motion, which is dependent on tissue mechanical properties.


Assuntos
Linfonodos , Microbolhas , Animais , Meios de Contraste/química , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Camundongos , Ultrassonografia/métodos
5.
Nanomedicine (Lond) ; 17(14): 1013-1025, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-36043897

RESUMO

Early and accurate diagnoses are important for successful cancer treatment. Lymph node involvement is often critical, and magnetomotive ultrasound (MMUS) has been proposed for its detection and characterization. MMUS relies on a magnetic contrast agent, for example, iron oxide nanoparticles, delivered to the tissue of interest, magnetically set in motion and detected using ultrasound. The magneto-mechanical interaction has not previously been evaluated on a cellular level. Here we demonstrate uptake and dose-dependent retention of magnetic nanoparticles in two human adenocarcinoma cell lines, with <10% cytotoxicity which did not increase following magnetic excitation. Further, the oxidative stress levels were not affected by magnetic particles or force. Thus, we found no evidence of adverse effects from the magneto-mechanical interactions under these conditions.


Assuntos
Meios de Contraste , Nanopartículas de Magnetita , Humanos , Meios de Contraste/química , Nanopartículas de Magnetita/química , Ultrassonografia , Magnetismo , Linfonodos
6.
Br J Radiol ; 95(1135): 20211128, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35522781

RESUMO

OBJECTIVES: Despite advances in MRI the detection and characterisation of lymph nodes in rectal cancer remains complex, especially when assessing the response to neoadjuvant treatment. An alternative approach is functional imaging, previously shown to aid characterisation of cancer tissues. We report proof of concept of the novel technique Contrast-Enhanced Magneto-Motive Ultrasound (CE-MMUS) to recover information relating to local perfusion and lymphatic drainage, and interrogate tissue mechanical properties through magnetically induced deformations. METHODS: The feasibility of the proposed application was explored using a combination of experimental animal and phantom ultrasound imaging, along with finite element analysis. First, contrast-enhanced ultrasound imaging on one wild type mouse recorded lymphatic drainage of magnetic microbubbles after bolus injection. Second, tissue phantoms were imaged using MMUS to illustrate the force- and elasticity dependence of the magnetomotion. Third, the magnetomechanical interactions of a magnetic microbubble with an elastic solid were simulated using finite element software. RESULTS: Accumulation of magnetic microbubbles in the inguinal lymph node was verified using contrast enhanced ultrasound, with peak enhancement occurring 3.7 s post-injection. The magnetic microbubble gave rise to displacements depending on force, elasticity, and bubble radius, indicating an inverse relation between displacement and the latter two. CONCLUSION: Combining magnetic microbubbles with MMUS could harness the advantages of both techniques, to provide perfusion information, robust lymph node delineation and characterisation based on mechanical properties. ADVANCES IN KNOWLEDGE: (a) Lymphatic drainage of magnetic microbubbles visualised using contrast-enhanced ultrasound imaging and (b) magnetomechanical interactions between such bubbles and surrounding tissue could both contribute to (c) robust detection and characterisation of lymph nodes.


Assuntos
Meios de Contraste , Microbolhas , Animais , Meios de Contraste/química , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Camundongos , Imagens de Fantasmas , Ultrassonografia/métodos
7.
Ultrasound Med Biol ; 48(2): 333-345, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34802840

RESUMO

Magnetomotive ultrasound is an emerging technique that enables detection of magnetic nanoparticles. This has implications for ultrasound molecular imaging, and potentially addresses clinical needs regarding determination of metastatic infiltration of the lymphatic system. Contrast is achieved by a time-varying magnetic field that sets nanoparticle-laden regions in motion. This motion is governed by vector-valued mechanical and magnetic forces. Understanding how these forces contribute to observed displacement patterns is important for the interpretation of magnetomotive ultrasound images. Previous studies have captured motion adjacent to nanoparticle-laden regions that was attributed to diamagnetism. While diamagnetism could give rise to a force, it cannot fully account for the observed displacements in magnetomotive ultrasound. To isolate explanatory variables of the observed displacements, a finite element model is set up. Using this model, we explore potential causes of the unexplained motion by comparing numerical models with earlier experimental findings. The simulations reveal motion outside particle-laden regions that could be attributed to mechanical coupling and the principle of mass conservation. These factors produced a motion that counterbalanced the time-varying magnetic excitation, and whose extent and distribution was affected by boundary conditions as well as compressibility and stiffness of the surroundings. Our findings emphasize the importance of accounting for the vector-valued magnetic force in magnetomotive ultrasound imaging. In an axisymmetric geometry, that force can be represented by a simple scalar expression, an oversimplification that rapidly becomes inaccurate with distance from the symmetry axis. Additionally, it results in an underestimation of the vertical force component by up to 30%. We therefore recommend using the full vector-valued force to capture the magnetic interaction. This study enhances our understanding of how forces govern magnetic nanoparticle displacement in tissue, contributing to accurate analysis and interpretation of magnetomotive ultrasound imaging.


Assuntos
Campos Magnéticos , Magnetismo , Análise de Elementos Finitos , Movimento (Física) , Ultrassonografia
8.
Ultrasound Med Biol ; 46(11): 3170-3171, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32782089
9.
Ultrasound Med Biol ; 46(10): 2636-2650, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32753288

RESUMO

This review discusses magnetomotive ultrasound, which is an emerging technique that uses superparamagnetic iron oxide nanoparticles as a contrast agent. The key advantage of using nanoparticle-based contrast agents is their ability to reach extravascular targets, whereas commercial contrast agents for ultrasound comprise microbubbles confined to the blood stream. This also extends possibilities for molecular imaging, where the contrast agent is labeled with specific targeting molecules (e.g., antibodies) so that pathologic tissue may be visualized directly. The principle of action is that an external time-varying magnetic field acts to displace the nanoparticles lodged in tissue and thereby their immediate surrounding. This movement is then detected with ultrasound using frequency- or time-domain analysis of echo data. As a contrast agent already approved for magnetic resonance imaging (MRI) by the US Food and Drug Administration, there is a shorter path to clinical translation, although safety studies of magnetomotion are necessary, especially if particle design is altered to affect biodistribution or signal strength. The external modulated magnetic field may be generated by electromagnets, permanent magnets, or a combination of the two. The induced nanoparticle motion may also reveal mechanical material properties of tissue, healthy or diseased, one of several interesting potential future aspects of the technique.


Assuntos
Meios de Contraste , Nanopartículas Magnéticas de Óxido de Ferro , Ultrassonografia/métodos , Humanos , Movimento (Física)
10.
Ultrasound Med Biol ; 46(8): 2070-2078, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32423572

RESUMO

The acoustic properties of ultrasound phantom materials have always been important, but with new applications interrogating tissue mechanical properties, viscoelasticity has also become an interesting feature to consider. Along with Young's modulus, the viscous component of tissue is affected by certain diseases and can therefore be used as a biomarker. Furthermore, viscoelasticity varies between tissue types and individuals, and therefore it would be useful with a phantom material that reflects this physiological range. Here we describe a gel for ultrasound imaging with a range of mechanical properties given by mixing different ratios of two oil-based gels, clear ballistic and styrene-ethylene/butylene-styrene (SEBS). The gels were mixed in five different proportions, ranging from 0-100% of either gel. For each of the gel compositions, we measured time of flight to determine speed of sound, narrowband ultrasound transmission for attenuation, stress-relaxation for viscoelasticity, mass and volume. Analysis of the stress-relaxation data using the generalized Maxwell model suggests that the material can be described by five parameters, E0, E1, E2, η1 and η2, and that each of these parameters decreases as more SEBS is incorporated into the mixed material. Instantaneous Young's modulus (the sum of E0, E1 and E2 in our model) ranges between 49 and 117 kPa for the different ratios, similar to values reported for cancerous tissue. Despite the large span of obtainable mechanical properties, speed of sound is relatively constant regardless of composition, with mean value estimates (± 95 % CI) between 1438 ± 9 and 1455 ± 3 m/s for pure and mixed gels. This was attributed to a variation in density and Poisson's ratio, following from the relation linking them to speed of sound and elasticity. Furthermore, both speed of sound and attenuation were within a suitable range for ultrasound phantoms. Combining this ballistic gel with SEBS copolymer in oil allows for control of mechanical properties, both elastic and viscous as evaluated by the material model. Furthermore, it does so without compromising ease of use, longevity and safety of the pre-made gel.


Assuntos
Imagens de Fantasmas , Som , Ultrassonografia , Elasticidade , Polietilenos , Poliestirenos , Substâncias Viscoelásticas , Viscosidade
11.
Sci Rep ; 7(1): 4824, 2017 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-28684867

RESUMO

Current methods for intra-surgical guidance to localize metastases at cancer surgery are based on radioactive tracers that cause logistical challenges. We propose the use of a novel ultrasound-based method, magnetomotive ultrasound (MMUS) imaging that employ a nanoparticle-based contrast agent that also may be used for pre-operative PET/MRI imaging. Since MMUS is radiation free, this eliminates the dependence between pre- and intra-operative imaging and the radiation exposure for the surgical staff. This study investigates a hypothetical clinical scenario of pre-operative PET imaging, combined with intra-operative MMUS imaging, implemented in a sentinel lymph node (SLN) rat model. At one-hour post injection of 68Ga-labelled magnetic nanoparticles, six animals were imaged with combined PET/CT. After two or four days, the same animals were imaged with MMUS. In addition, ex-vivo MRI was used to evaluate the amount of nanoparticles in each single SLN. All SLNs were detectable by PET. Four out of six SLNs could be detected with MMUS, and for these MMUS and MRI measurements were in close agreement. The MRI measurements revealed that the two SLNs undetectable with MMUS contained the lowest nanoparticle concentrations. This study shows that MMUS can complement standard pre-operative imaging by providing bedside real-time images with high spatial resolution.


Assuntos
Meios de Contraste/química , Radioisótopos de Gálio/química , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Linfonodo Sentinela/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Animais , Meios de Contraste/farmacocinética , Feminino , Compostos Férricos/química , Radioisótopos de Gálio/farmacocinética , Humanos , Imageamento por Ressonância Magnética/instrumentação , Nanopartículas de Magnetita/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Ratos , Ratos Wistar , Biópsia de Linfonodo Sentinela , Coloração e Rotulagem/métodos , Tomografia Computadorizada por Raios X/instrumentação , Ultrassonografia/instrumentação
12.
Artigo em Inglês | MEDLINE | ID: mdl-25073135

RESUMO

Detection and removal of sentinel lymph nodes (SLN) is important in the diagnosis and treatment of cancer. The SLN is the first regional lymph node draining the primary tumor, and if the cancer has spread, it is most likely to find metastases in the SLN. In this study, we have for the first time been able to image the very same contrast agent, superparamagnetic iron oxide nanoparticles (SPIO-NPs), in rat SLNs by using both our frequency- and phase-gated magnetomotive ultrasound (MMUS) algorithm and conventional magnetic resonance imaging (MRI); MMUS post mortem, MRI in vivo. For both higher NP-concentration and smaller NPs, we found that the MMUS data showed a larger magnetomotive displacement (1.56 ± 0.43 and 1.94 ± 0.54 times larger, respectively) and that the MR-images were affected to a higher degree. The MMUS displacement also increased with lower excitation frequency (1.95 ± 0.64 times larger for 5 Hz compared with 15 Hz) and higher excitation voltage (2.95 ± 1.44 times larger for 30 V compared with 10 V). The results show that MMUS has potential to be used as bedside guidance during SLN surgery, imaging the same particles that were used in prior staging with other imaging techniques.


Assuntos
Linfonodos/química , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/análise , Animais , Feminino , Linfonodos/metabolismo , Nanopartículas de Magnetita/administração & dosagem , Nanopartículas de Magnetita/química , Ratos , Ratos Wistar , Ultrassonografia
13.
Artigo em Inglês | MEDLINE | ID: mdl-23475915

RESUMO

It has recently been demonstrated that superparamagnetic iron oxide nanoparticles can be used as magnetomotive ultrasound contrast agents. A time-varying external magnetic field acts to move the particles and, thus, the nanoparticle-laden tissue. However, the difficulty of distinguishing this magnetomotive motion from undesired movement induced in regions without nanoparticles or other motion artifacts has not been well reported. Using a high-frequency linear-array system, we found that displacements outside nanoparticle-laden regions can be similar in magnitude to those in regions containing nanoparticles. We also found that the displacement outside the nanoparticle regions had a phase shift of approximately π radians relative to that in the nanoparticle regions. To suppress signals arising from undesirable movements, we developed an algorithm based on quadrature detection and phase gating at the precise frequency of nanoparticle displacement. Thus, clutter at other frequencies can be filtered out, and the processed signal can be color-coded and superimposed on the B-mode image. The median signal-to-clutter ratio improvement using the proposed algorithm was 36 dB compared with simply summing the movement energy at all frequencies. This clutter rejection is a crucial step to move magnetomotive ultrasound imaging of nanoparticles toward in vivo investigations.


Assuntos
Meios de Contraste/química , Nanopartículas de Magnetita/química , Processamento de Sinais Assistido por Computador , Ultrassonografia/instrumentação , Algoritmos , Imagens de Fantasmas , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...