Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Mol Neurosci ; 15: 979479, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36034500

RESUMO

Cell-attached current-clamp (CA/CC) recordings have been proposed to measure resting membrane potential and synaptic/agonist responses in neurons without disrupting the cell membrane, thus avoiding the intracellular dialysis that occurs in conventional whole-cell recordings (WC). However, the accuracy of CA/CC recordings in neurons has not been directly assessed. Here, we used concomitant CA and WC current clamp recordings from cortical neurons in brain slices. Resting membrane potential values and slow voltage shifts showed variability and were typically attenuated during CA/CC recordings by ~10-20% relative to WC values. Fast signals were slowed down and their amplitude was greatly reduced: synaptic potentials by nearly 2-fold, and action potentials by nearly 10-fold in CA/CC mode compared to WC. The polarity of GABAergic postsynaptic responses in CA/CC mode matched the responses in WC, and depolarising GABAergic potentials were predominantly observed during CA/CC recordings of intact neonatal CA3 hippocampal pyramidal neurons. Similarly, CA/CC recordings reliably detected neuronal depolarization and excitation during network-induced giant depolarizing potentials in the neonatal CA3 hippocampus, and revealed variable changes, from depolarization to hyperpolarization, in CA1 pyramidal cells during sharp wave ripples in the adult hippocampus. Thus, CA/CC recordings are suitable for assessing membrane potential but signal distortion, probably caused by leakage via the seal contact and RC filtering should be considered.

2.
eNeuro ; 8(4)2021.
Artigo em Inglês | MEDLINE | ID: mdl-34380654

RESUMO

Full-band DC recordings enable recording of slow electrical brain signals that are severely compromised during conventional AC recordings. However, full-band DC recordings may be limited by the amplifier's dynamic input range and the loss of small amplitude high-frequency signals. Recently, Neuralynx has proposed full-band recordings with inverse filtering for signal reconstruction based on hybrid AC/DC-divider RRC filters that enable only partial suppression of DC signals. However, the quality of signal reconstruction for biological signals has not yet been assessed. Here, we propose a novel digital inverse filter based on a mathematical model describing RRC filter properties, which provides high computational accuracy and versatility. Second, we propose procedures for the evaluation of the inverse filter coefficients, adapted for each recording channel to minimize the error caused by the deviation of the real values of the RRC filter elements from their nominal values. We demonstrate that this approach enables near 99% reconstruction quality of high-potassium-induced cortical spreading depolarizations (SDs), endothelin-induced ischemic negative ultraslow potentials (NUPs), and whole-cell recordings of membrane potential using RRC filters. The quality of the reconstruction was significantly higher than with the existing inverse filtering procedures. Thus, RRC filters with inverse filtering are optimal for full-band EEG recordings in various applications.


Assuntos
Encéfalo , Eletroencefalografia , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA