1.
Magn Reson Med Sci ; 13(3): 145-53, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24990468

RESUMO

PURPOSE: We explored a recovery correction technique that can correct metabolite loss during perchloric acid (PCA) extraction and minimize inter-assay variance in quantitative (1)H nuclear magnetic resonance (NMR) spectroscopy of the brain and evaluated its efficacy in 5-fluorouracil (5-FU)- and saline-administered rats. METHODS: We measured the recovery of creatine and dl-valine-2,3-d2 from PCA extract containing both compounds (0.5 to 8 mM). We intravenously administered either 5-FU for 4 days (total, 100 mg/kg body weight) or saline into 2 groups of 11 rats each. We subsequently performed PCA extraction of the whole brain on Day 9, externally adding 7 µmol of dl-valine-2,3-d2. We estimated metabolite concentrations using an NMR spectrometer with recovery correction, correcting metabolite concentrations based on the recovery factor of dl-valine-2,3-d2. For each metabolite concentration, we calculated the coefficient of variation (CEV) and compared differences between the 2 groups using unpaired t-test. RESULTS: Equivalent recoveries of dl-valine-2,3-d2 (89.4 ± 3.9%) and creatine (89.7 ± 3.9%) in the PCA extract of the mixed solution indicated the suitability of dl-valine-2,3-d2 as an internal reference. In the rat study, recovery of dl-valine-2,3-d2 was 90.6 ± 9.2%. Nine major metabolite concentrations adjusted by recovery of dl-valine-2,3-d2 in saline-administered rats were comparable to data in the literature. CEVs of these metabolites were reduced from 10 to 17% before to 7 to 16% after correction. The significance of differences in alanine and taurine between the 5-FU- and saline-administered groups was determined only after recovery correction (0.75 ± 0.12 versus 0.86 ± 0.07 for alanine; 5.17 ± 0.59 versus 5.66 ± 0.42 for taurine [µmol/g brain tissue]; P < 0.05). CONCLUSION: A new recovery correction technique corrected metabolite loss during PCA extraction, minimized inter-assay variance in quantitative (1)H NMR spectroscopy of brain tissue, and effectively detected inter-group differences in concentrations of brain metabolites between 5-FU- and saline-administered rats.


Assuntos
Encefalopatias/metabolismo , Encéfalo/metabolismo , Fluoruracila/administração & dosagem , Espectroscopia de Ressonância Magnética/métodos , Percloratos , Valina/metabolismo , Animais , Creatina/metabolismo , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Cloreto de Sódio/administração & dosagem
2.
J Magn Reson Imaging ; 38(1): 225-30, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23238830

RESUMO

PURPOSE: To explore simultaneous magnetic resonance imaging (MRI) for multiple hepatoma-bearing rats in a single session suppressing motion- and flow-related artifacts to conduct preclinical cancer research efficiently. MATERIALS AND METHODS: Our institutional Animal Experimental Committee approved this study. We acquired PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) T2 - and diffusion-weighted images of the liver in one healthy and 11 N1-S1 hepatoma-bearing rats in three sessions using a 3-T clinical scanner and dedicated multiarray coil. We compared tumor volumes on MR images and those on specimens, evaluated apparent diffusion coefficients (ADC) of the tumor, and compared them to previously reported values. RESULTS: Each MRI session took 39-50 minutes from anesthesia induction to the end of scans for four rats (10-13 minutes per rat). PROPELLER provided artifact-reduced T2 - and diffusion-weighted images of the rat livers. Tumor volumes on MR images ranged from 0.04-1.81 cm(3) and were highly correlated with those on specimens. The ADC was 1.57 ± 0.37 × 10(-3) mm(2) /s (average ± SD), comparable to previously reported values. CONCLUSION: PROPELLER allowed simultaneous acquisition of artifact-reduced T2 - and diffusion-weighted images of multiple hepatoma-bearing rats. This technique can promote high-throughput preclinical MR research for liver cancer.


Assuntos
Algoritmos , Artefatos , Carcinoma Hepatocelular/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Linhagem Celular Tumoral , Feminino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade