1.
Phys Med Biol ; 63(21): 215012, 2018 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-30353889

RESUMO

Four-dimensional (4D) Ultrafast ultrasound imaging was recently proposed to image and quantify blood flow with high sensitivity in 3D as well as anatomical, mechanical or functional information. In 4D Ultrafast imaging, coherent compounding of tilted planes waves emitted by a 2D matrix array were used to image the medium at high volume rate. 4D ultrafast imaging, however, requires a high channel count (>1000) to drive those probes. Alternative approaches have been proposed and investigated to efficiently reduce the density of elements, such as sparse or under-sampled arrays while maintaining a decent image quality and high volume rate. The row-columns configuration presents the advantage of keeping a large active surface with a low amount of elements and a simple geometry. In this study, we investigate the row and column addressed (RCA) approach with the orthogonal plane wave (OPW) compounding strategy using real hardware limitations. We designed and built a large 7 MHz 128 + 128 probe dedicated to vascular imaging and connected to a 256-channel scanner to implement the OPW imaging scheme. Using this strategy, we demonstrate that 4D ultrafast Power Doppler imaging of a large volume of [Formula: see text] up to [Formula: see text] depth, both in vitro on flow phantoms and in vivo on the carotid artery of a healthy volunteer at a volume rate of 834 Hz.


Assuntos
Imageamento Tridimensional/métodos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Hemodinâmica , Humanos , Fatores de Tempo , Ultrassonografia Doppler/métodos
2.
Phys Med Biol ; 62(11): 4571-4588, 2017 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-28248655

RESUMO

4D ultrafast ultrasound imaging was recently shown using a 2D matrix (i.e. fully populated) connected to a 1024-channel ultrafast ultrasound scanner. In this study, we investigate the row-column addressing (RCA) matrix approach, which allows a reduction of independent channels from N × N to N + N, with a dedicated beamforming strategy for ultrafast ultrasound imaging based on the coherent compounding of orthogonal plane wave (OPW). OPW is based on coherent compounding of plane wave transmissions in one direction with receive beamforming along the orthogonal direction and its orthogonal companion sequence. Such coherent recombination of complementary orthogonal sequences leads to the virtual transmit focusing in both directions which results into a final isotropic point spread function (PSF). In this study, a 32 × 32 2D matrix array probe (1024 channels), centered at 5 MHz was considered. An RCA array, of same footprint with 32 + 32 elements (64 channels), was emulated by summing the elements either along a line or a column in software prior to beamforming. This approach allowed for the direct comparison of the 32 + 32 RCA scheme to the optimal fully sampled 32 × 32 2D matrix configuration, which served as the gold standard. This approach was first studied through PSF simulations and then validated experimentally on a phantom consisting of anechoic cysts and echogenic wires. The contrast-to-noise ratio and the lateral resolution of the RCA approach were found to be approximately equal to half (in decibel) and twice the values, respectively, obtained when using the 2D matrix approach. Results in a Doppler phantom and the human humeral artery in vivo confirmed that ultrafast Doppler imaging can be achieved with reduced performances when compared against the equivalent 2D matrix. Volumetric anatomic Doppler rendering and voxel-based pulsed Doppler quantification are presented as well. OPW compound imaging using emulated RCA matrix can achieve a power Doppler with sufficient contrast to recover the vein shape and provides an accurate Doppler spectrum.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Humanos
3.
Ultrasonics ; 42(1-9): 465-71, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047330

RESUMO

This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on the directivity pattern are shown. A theoretical analysis of acousto-optic phenomenon, based on the plane wave decomposition of radiated field by the array is developed. Theoretical and experimental results are compared, showing first that waves with phase velocity near the one of the fluid are greatly amplified. Second, the interaction of laser beam with edge wave produced by the vertical size of elements induces a parasitic temporal pulse on the x-t diagram and so an interference pattern in the omega-k diagram. Corrections are proposed to eliminate errors induced by acousto-optic interactions and validated by comparing predicted diffraction field with measurements.