Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 15: 1647-1657, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33907378

RESUMO

PURPOSE: This study assessed effectiveness and safety of the novel Clareon intraocular lens (IOL; model SY60CL; Alcon Vision LLC). PATIENTS AND METHODS: This was a prospective, single-arm, unmasked clinical trial at 16 investigative clinical sites in the United States. Included were adults ≥22 years who required cataract extraction by phacoemulsification. Following phacoemulsification, 350 subjects received SY60CL IOL unilaterally; 342 completed the study. Monocular best corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) were evaluated. The primary effectiveness endpoint was the percentage of subjects with CDVA ≤0.3 logMAR at month 12. Safety was assessed by monitoring adverse events (AEs). Visual acuity and safety outcomes were compared with historical safety and performance endpoint (SPE) rates. RESULTS: At 12 months post-implantation, 99.7% of subjects receiving the SY60CL IOL achieved monocular CDVA ≤0.3 logMAR (primary effectiveness endpoint; 1-sided 95% upper confidence limit >SPE rate); 99.7% and 86.8% of subjects achieved monocular CDVA of ≤0.34 (20/40 Snellen or better) and ≤0.04 logMAR (20/20 Snellen or better), respectively. At 12 months, >95% of subjects achieved mean monocular UDVA ≤0.3 logMAR; 97.1% and 57.6% of subjects achieved monocular CDVA of ≤0.34 and ≤0.04 logMAR, respectively. Mean monocular CDVA and UDVA were -0.05 and 0.04 logMAR, respectively. AEs were within SPE limits. The most common nonserious ocular AE was posterior capsule opacification (5.4%). Serious AEs were <1%, and no serious ocular AEs were assessed as related to the device. There were no observations for IOL glistenings at 12 months. CONCLUSION: Results of this study supported effectiveness and safety of the SY60CL IOL. Visual acuity outcomes with the SY60CL IOL exceeded the SPE rates for monocular CDVA and AEs were within the limit of historic SPE rates. (Model number SY60WF is the Clareon lens approved by the FDA.).

2.
J Cataract Refract Surg ; 43(1): 29-41, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28317674

RESUMO

PURPOSE: To assess the effectiveness and safety of a multifocal intraocular lens (IOL) with +2.5 diopter (D) additional power compared with a monofocal IOL. SETTING: Fifteen sites in the United States. DESIGN: Prospective randomized patient- and observer-masked clinical trial. METHODS: Randomized patients received multifocal or monofocal IOLs bilaterally. Visual acuity (33 cm, 40 cm, 53 cm, 60 cm, 4 m) was measured; safety was assessed through adverse event rates. Patient-reported visual outcomes were evaluated using the Visual Tasks questionnaire. The frequency and severity of visual disturbances were evaluated using the Assessment of Photic Phenomena and Lens EffectS questionnaire. RESULTS: The multifocal IOL (n = 155) provided better corrected distance visual acuity at 53 cm than the monofocal IOL (n = 165) (0.322 versus 0.512 logMAR; between-group difference, -0.190 logMAR; P < .0001) and 40 cm but not at 4 m. Ocular adverse event rates were less than 3.84% in both groups. Serious adverse event rates were comparable between the 2 IOL types. Patients with multifocal IOLs reported less difficulty with near tasks (with and without correction) and intermediate tasks (without correction). Difficulty with extended-intermediate and distance tasks was similar between groups. The most frequently reported self-rated severe phenomena were halos, starbursts, and glare. Most patients (monofocal ≥72%; multifocal ≥73%) reported never experiencing blurred, distorted, or double vision. CONCLUSIONS: The +2.5 D multifocal IOL provided better vision at 40 cm and 53 cm and similar vision at 4 m compared with the monofocal IOL. Safety profiles and visual phenomena were comparable between groups.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Facoemulsificação , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Método Duplo-Cego , Feminino , Ofuscação , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Estudos Prospectivos , Inquéritos e Questionários , Visão Binocular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA