Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Sci Total Environ ; 818: 151803, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-34808151

RESUMO

Plant-soil interactions affect arsenic and nutrient availability in arsenic-contaminated soils, with implications for arsenic uptake and tolerance in plants, and leaching from soil. In 22-week column experiments, we grew the arsenic hyperaccumulating fern Pteris vittata in a coarse- and a medium-textured soil to determine the effects of phosphorus fertilization and mycorrhizal fungi inoculation on P. vittata arsenic uptake and arsenic leaching. We investigated soil arsenic speciation using synchrotron-based spectromicroscopy. Greater soil arsenic availability and lower nutrient content in the coarse-textured soil were associated with greater fern arsenic uptake, lower biomass (apparently a metabolic cost of tolerance), and arsenic leaching from soil, due to lower transpiration. P. vittata hyperaccumulated arsenic from coarse- but not medium-textured soil. Mass of plant-accumulated arsenic was 1.2 to 2.4 times greater, but aboveground biomass was 74% smaller, in ferns growing in coarse-textured soil. In the presence of ferns, mean arsenic loss by leaching was 195% greater from coarse- compared to the medium-textured soil, and lower across both soils compared to the absence of ferns. In the medium-textured soil arsenic concentrations in leachate were higher in the presence of ferns. Fern arsenic uptake was always greater than loss by leaching. Most arsenic (>66%) accumulated in P. vittata appeared of rhizosphere origin. In the medium-textured soil with more clay and higher nutrient content, successful iron scavenging increased arsenic release from soil for leaching, but transpiration curtailed leaching.


Assuntos
Arsênio , Pteris , Poluentes do Solo , Arsênio/análise , Biodegradação Ambiental , Biomassa , Nutrientes , Pteris/metabolismo , Solo , Poluentes do Solo/análise
2.
Data Brief ; 31: 105969, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32728601

RESUMO

Implant-bone biomechanics and mechanoadaptation of peri­implant tissue in space (around and along the length of an implant) and time (3-, 11-, and 24-day following implantation) are important for functional osseointegration of dental implants. Spatiotemporal shifts in biomechanics of implant-bone complex in rat maxillae were correlated with maximum (tensile) and minimum (compressive) principal strain profiles in peri­implant tissue using a hybrid model; biomechanics in situ paired with digital volume correlation. Spatiotemporal changes in elemental counts and their association with mineral density of the peri­implant tissue were mapped using electron dispersive X-ray and X-ray fluorescence microprobe techniques. Data provided within are related to biomechanical testing of an implant-bone complex in situ. Data also highlight the power of correlating elemental colocalization with tension and compression regions of the peri­implant tissues to explain spatiotemporal mechanoadaptation of implant-bone complexes. Further interpretation of data is provided in "Mechanoadaptive Strain and Functional Osseointegration of Dental Implants in Rats [1]."

3.
Interface Focus ; 10(4): 20200012, 2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32637067

RESUMO

Three-dimensionally preserved Ediacaran fossils occur globally within sandstone beds. Sandy siliciclastic deposits of the Ediacaran Wood Canyon Formation (WCF) in the Montgomery Mountains, Nevada, contain two fossil morphologies with similar shapes and sizes: one exhibits mm-scale ridges and a distinct lower boundary and the other is devoid of these diagnostic features. We interpret these as taphomorphs of erniettomorphs, soft-bodied organisms with uncertain taxonomic affinities. We explore the cast-and-mould preservation of both taphomorphs by petrography, Raman spectroscopy, X-ray fluorescence microprobe and X-ray diffraction. All fossils and the surrounding sedimentary matrix contain quartz grains, iron-rich chlorite and muscovite. The ridged fossils contain about 70% larger quartz grains compared to the ridgeless taphomorph, indicating a lower abundance of clay minerals in the ridged fossil. Chlorite and muscovite likely originated from smectite and kaolinite precursors that underwent lower greenschist facies metamorphism. Kaolinite and smectite are inferred to have been abundant in sediments around the ridged fossil, which enabled the preservation of a continuous, distinct, clay- and kerogen-rich bottom boundary. The prevalence of quartz in the ridged fossils of the WCF and in erniettomorphs from other localities also suggests a role for this mineral in three-dimensional preservation of erniettomorphs in sandstone and siltstone deposits.

4.
Bone ; 137: 115375, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32335376

RESUMO

Spatiotemporal implant-bone biomechanics and mechanoadaptive strains in peri-implant tissue are poorly understood. Physical and chemical characteristics of an implant-bone complex (IBC) were correlated in three-dimensional space (along the length and around a dental implant) to gather insights into time related integration of the implant with the cortical portion of a jaw bone in a rat. Rats (N = 9) were divided into three experimental groups with three rats per time point; 3-, 11-, and 24-day. All rats were fed crumbled hard pellets mixed with water (soft-food diet) for the first 3 days followed by a hard-food diet with intact hard-food pellets (groups of 11- and 24-day only). Biomechanics of the IBCs harvested from rats at each time point was evaluated by performing mechanical testing in situ in tandem with X-ray imaging. The effect of physical association (contact area) of a loaded implant with adapting peri-implant tissue, and resulting strain within was mapped by using digital volume correlation (DVC) technique. The IBC stiffness at respective time points was correlated with mechanical strain in peri-implant tissue. Results illustrated that IBC stiffness at 11-day was lower than that observed at 3-day. However, at 24-day, IBC stiffness recovered to that which was observed at 3-day. Correlative microscopy and spectroscopy illustrated that the lower IBC stiffness was constituted by softer and less mineralized peri-implant tissue that contained varying expressions of osteoconductive elements. Lower IBC stiffness observed at 11-day was constituted by less mineralized peri-implant tissue with osteoconductive elements that included phosphorus (P) which was co-localized with higher expression of zinc (Zn), and lower expression of calcium (Ca). Higher IBC stiffness at 24-day was constituted by mineralized peri-implant tissue with higher expressions of osteoconductive elements including Ca and P, and lower expressions of Zn. These spatiotemporal correlative maps of peri-implant tissue architecture, heterogeneous distribution of mineral density, and elemental colocalization underscore mechanoadaptive physicochemical properties of peri-implant tissue that facilitate functional osseointegration of an implant. These results provided insights into 1) plausible "prescription" of mechanical loads as an osteoinductive "therapeutic dose" to encourage osteoconductive elements in the peri-implant tissue that would facilitate functional osseointegration of the implant; 2) a "critical temporal window" between 3 and 11 days, and perhaps it is this acute phase during which key candidate regenerative molecules can be harnessed to accelerate osseointegration of an implant under load.


Assuntos
Implantes Dentários , Osseointegração , Animais , Fenômenos Biomecânicos , Ratos , Titânio
5.
J Synchrotron Radiat ; 10(Pt 2): 125-36, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12606790

RESUMO

Two new soft X-ray scanning transmission microscopes located at the Advanced Light Source (ALS) have been designed, built and commissioned. Interferometer control implemented in both microscopes allows the precise measurement of the transverse position of the zone plate relative to the sample. Long-term positional stability and compensation for transverse displacement during translations of the zone plate have been achieved. The interferometer also provides low-distortion orthogonal x, y imaging. Two different control systems have been developed: a digital control system using standard VXI components at beamline 7.0, and a custom feedback system based on PC AT boards at beamline 5.3.2. Both microscopes are diffraction limited with the resolution set by the quality of the zone plates. Periodic features with 30 nm half period can be resolved with a zone plate that has a 40 nm outermost zone width. One microscope is operating at an undulator beamline (7.0), while the other is operating at a novel dedicated bending-magnet beamline (5.3.2), which is designed specifically to illuminate the microscope. The undulator beamline provides count rates of the order of tens of MHz at high-energy resolution with photon energies of up to about 1000 eV. Although the brightness of a bending-magnet source is about four orders of magnitude smaller than that of an undulator source, photon statistics limited operation with intensities in excess of 3 MHz has been achieved at high energy resolution and high spatial resolution. The design and performance of these microscopes are described.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...