Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Anal Chem ; 95(50): 18549-18556, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38073045

RESUMO

The clustered regularly interspaced short palindromic repeats (CRISPR/Cas12a) system has exhibited great promise in the rapid and sensitive molecular diagnostics for its trans-cleavage property. However, most CRISPR/Cas system-based detection methods are designed for nucleic acids and require target preamplification to improve sensitivity and detection limits. Here, we propose a generic crRNA switch circuit-regulated CRISPR/Cas sensor for the sensitive detection of various targets. The crRNA switch is engineered and designed in a blocked state but can be activated in the presence of triggers, which are target-induced association DNA to initiate the trans-cleavage activity of Cas12a for signal reporting. Additionally, RNase H is introduced to specifically hydrolyze RNA duplexed with the DNA trigger, resulting in the regeneration of the trigger to activate more crRNA switches. Such a combination provides a generic and sensitive strategy for the effective sensing of the p53 sequence, thrombin, and adenosine triphosphate. The design is incorporated with nucleic acid nanotechnology and extensively broadens the application scope of the CRISPR technology in biosensing.


Assuntos
Técnicas Biossensoriais , RNA Guia de Sistemas CRISPR-Cas , Ribonuclease H , RNA , Sistemas CRISPR-Cas/genética , DNA
2.
J Cardiothorac Surg ; 17(1): 77, 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35421997

RESUMO

BACKGROUND: Sexual dysfunction after cardiac surgery can seriously affect patients' quality of life, but the impact of cardiac surgery on sexual function has long been neglected. Compared with conventional cardiac surgery, minimally invasive cardiac surgery has the advantages of aesthetic appearance and no disruption of the sternal structure, which can greatly improve the patient's quality of life. However, studies focusing on the effects of minimally invasive mitral valve surgery (MIMVS) on sexual function have not been reported. The objective of this research was to investigate the effects of totally endoscopic mitral valve surgery on health-related quality of life and sexual function in male patients and to provide possible recommendations. METHODS: Patients who underwent median sternotomy or totally endoscopic mitral valve surgery at our institution from January 2019 to December 2020 were selected using an electronic medical record system. Data were collected by questionnaires, including the MOS 36-item short-form health survey and the International Erectile Function Questionnaire. RESULTS: There were 156 male patients who participated in our study. Of these, 112 patients completed all questionnaires. Forty-five patients (40.18%) developed postoperative sexual dysfunction, including 15 patients (29.41%) in the MIMVS group and 30 patients (49.18%) in the conventional MVS group, indicating that the incidence of sexual dysfunction could be reduced by MIMVS and that the MIMVS group scored better on the International Erectile Function Questionnaire (P < 0.05). On the evaluation of health-related quality of life, the MIMVS group scored better than the MVS group on the mental health and bodily pain subscales of the MOS 36-item short-form health survey. In addition, our study showed that postoperative sexual dysfunction was associated with physical functioning and mental health. CONCLUSIONS: In our study, totally endoscopic mitral valve surgery had less adverse effects on sexual function in male patients than conventional mitral valve surgery. In terms of health-related quality of life, totally endoscopic mitral valve surgery was superior to conventional surgery. Patients who opt for totally endoscopic mitral valve surgery may have a more satisfying and healthier sexual life than those who undergo conventional mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Disfunção Erétil , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Disfunção Erétil/etiologia , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Valva Mitral/cirurgia , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
3.
J Thorac Cardiovasc Surg ; 164(4): 1045-1052, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-33223195

RESUMO

BACKGROUND: Partial upper sternotomy (mini-ER) can be used in some adult cardiac surgeries but is seldom performed in the treatment of acute type A aortic dissection (AAAD). This study aimed to assess the feasibility and short-term outcomes of complete stent-graft replacement of the arch with triple-branched stent graft for AAAD through a mini-ER. METHODS: From 2015 to 2018, 254 patients with AAAD underwent complete stent-graft replacement of the arch with a triple-branched stent graft. Replacement was performed with conventional full sternotomy (con-ER) in 142 patients and with mini-ER in the other 112 patients. Using propensity score matching, the clinical data were compared between 100 patients in the mini-ER group and 100 patients in the con-ER group. RESULTS: After propensity score matching, there were no significant between-group differences in aortic cross-clamp time, cardiopulmonary bypass time, or total operative time. The amount of mediastinal drainage and number of red blood cell units were significantly lower in the mini-ER group compared with the con-ER group (P < .001). The intubation time was significantly shorter in the mini-ER group (P < .001). The treatment costs were also lower in the mini-ER group (P < .001). There were no significant between-group differences in 30-day mortality (9% vs 8%; P > .99) or postoperative complications. CONCLUSIONS: This study shows that extensive repair of AAAD through a mini-ER is feasible. It was superior to con-ER in terms of blood loss, postoperative ventilation time, and treatment costs.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Adulto , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Humanos , Estudos Retrospectivos , Stents , Esternotomia/efeitos adversos , Resultado do Tratamento
4.
Heart Surg Forum ; 24(5): E882-E886, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34623253

RESUMO

BACKGROUND: To investigate and analyze the learning curve of totally thoracoscopic mitral valve replacement and provide a quantitative reference for cardiac surgeons to carry out the operation step by step. METHODS: The clinical data were retrospectively analyzed of 100 consecutive patients with totally thoracoscopic mitral valve replacement successively performed by the same surgeon in a single center from May 2019 to June 2020. The learning curve was divided into 2 stages by using cumulative sum analysis, and relevant surgical parameters and perioperative indicators were analyzed. RESULTS: The first stage of the learning curve is the skill acquisition stage, which includes 1 to 40 surgical procedures. The second stage is the proficiency stage, involving 41 to 100 operations. Among the surgical parameters of the patients in the 2 stages, detectable improvements were observed in operative time, cardiopulmonary bypass time, cross-clamp time, and intraoperative injury. After surgery, the amount of drainage, length of hospital stay, blood creatinine levels, and oxygenation index 24 h after surgery were also significantly different between the 2 groups (all P < .05). The age and sex distributions of the patients were balanced, and there was no statistically significant difference in terms of conversion to median sternotomy between the 2 stages (P > .05). CONCLUSIONS: Cumulative sum analysis was used to accurately analyze the learning curve of totally thoracoscopic mitral valve replacement, indicating that 40 cases are needed to master the technique.


Assuntos
Educação de Pós-Graduação em Medicina/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/educação , Curva de Aprendizado , Valva Mitral/cirurgia , Cirurgiões/educação , Cirurgia Torácica/educação , Toracoscopia/métodos , Adulto , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Duração da Cirurgia , Estudos Retrospectivos
5.
J Invest Surg ; 34(4): 467-472, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31366250

RESUMO

BACKGROUND: Few comparative studies have focused on the advantages and disadvantages of transthoracic device closure, transcatheter device closure, and surgical repair via right submammary thoracotomy for restrictive ventricular septal defect (VSD). In this article, we compared the safety, efficacy, and clinical effects of these three treatments. Methods: The clinical data of 192 pediatric patients with a restrictive VSD in our hospital from January 2017 to May 2018 were retrospectively collected and analyzed. According to the different treatments, the patients were divided into three groups (the surgical and device groups). Results: There was no significant difference in the demographic characteristics, VSD size, mean pulmonary artery pressure, or cardiothoracic ratio. In addition, there were significant differences in the duration of mechanical ventilation, operation, hospitalization, and ICU stay between the two device groups and the surgical group, but there were no significant differences between the two device groups. Conclusions: Transthoracic device closure, transcatheter device closure, and surgical repair via right submammary thoracotomy for restrictive VSD repair are all safe and feasible. These three treatments have their own disadvantages and advantages and should be selected according to individual patients.


Assuntos
Comunicação Interventricular , Toracotomia , Criança , Comunicação Interventricular/cirurgia , Humanos , Duração da Cirurgia , Estudos Retrospectivos , Toracotomia/efeitos adversos , Resultado do Tratamento
6.
Ann Thorac Surg ; 112(1): 75-82, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33098877

RESUMO

BACKGROUND: The patch neointima technique is a modified valve-sparing aortic root repair surgery for acute type A aortic dissection and the short-term outcomes are satisfactory. The midterm outcomes have not been reported. METHODS: From January 2009 to December 2012, 147 patients underwent valve-sparing aortic root repair with the patch neointima technique for type A aortic dissection in our center. The midterm outcomes of the patients were evaluated by echocardiography and aortic computed tomography angiography. RESULTS: Of 147 patients, 32 patients (21.8%) underwent proximal arch repair, and 115 patients (78.2%) underwent proximal arch repair combined with triple-branched stent graft implantation. The perioperative mortality was 5.4%. Preoperative aortic insufficiency (AI) was observed in 94 patients (63.9%); 131 patients (89.1%) left the operating room with 0 AI; the remaining 16 patients (10.9%) had trace or less than 1+ AI. A total of 128 patients (87.1%) completed 7-year follow-up. The mean follow-up time was 5.7 ± 1.2 years. As many as 82% of patients (105) were 0 AI and 15.6% of patients (20) were 0.5+ trace or less than 1+ AI. No reoperation was performed for the aortic root. The diameters of sinotubular junction and sinus were reduced to the normal range (28.3 ± 4.2 mm and 30.5 ± 3.6 mm, respectively) and remained stable (28.9 ± 5.6 mm, P = .300, and 30.8 ± 4.2 mm, P = .540, respectively) during 7 years of follow-up. CONCLUSIONS: Valve-sparing aortic root repair with patch neointima technique was associated with stable function of the aortic valves and no expansion of the aortic root in the midterm.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Neointima/cirurgia , Doença Aguda , Adulto , Dissecção Aórtica/diagnóstico , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Neointima/diagnóstico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
Ann Thorac Surg ; 111(3): e205-e207, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33121969

RESUMO

Herein we described a novel repair approach for a left atrial esophageal fistula. Complete mediastinal debridement and simultaneous primary repairs of the left atrial posterior wall and the esophagus were completed under a median sternotomy, central cardiopulmonary bypass, left atrial circular incision around four pulmonary veins, inflamed left atrial posterior wall removal, and posterior pericardial opening.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/efeitos adversos , Fístula Esofágica/cirurgia , Esôfago/cirurgia , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiologia , Fístula/diagnóstico , Fístula/etiologia , Fístula/cirurgia , Átrios do Coração , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Cardiopatias/cirurgia , Humanos , Reoperação , Tomografia Computadorizada por Raios X
8.
Ann Thorac Surg ; 110(3): 925-932, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31991134

RESUMO

BACKGROUND: The efficacy of hemiarch replacement combined with a modified triple-branched stent graft in Debakey type I aortic dissection remains to be confirmed. METHODS: From January 2016 to December 2017, 167 patients with acute Debakey type I aortic dissection underwent hemiarch replacement combined with a modified triple-branched stent graft. The clinical and imaging data were retrospectively analyzed. The early composite endpoint was defined to comprise perioperative mortality, permanent neurologic deficits, and renal failure requiring hemodialysis at discharge. RESULTS: The overall 30-day mortality was 4.2% (7 of 167). The incidence of the composite endpoint was 11.4% (19 of 167). The risk factors for the composite endpoint were malperfusion syndrome (odds ratio 5.17; 95% confidence interval, 1.46 to 18.35; P = .011) and creatine greater than 1.5 mg/dL (odds ratio 5.44; 95% confidence interval, 2.27 to 13.06; P < .001). The overall survival was 94% at 1 year and 92.2% at 2 years during a median follow-up of 20.9 ± 9.6 months. Three patients required distal aorta reintervention. Complete thrombosis in the false lumen of the descending aorta at the level of the pulmonary bifurcation and at the level of the celiac trunk was observed in 98.8% and 10.8% of the patients, respectively. CONCLUSIONS: Hemiarch replacement combined with a modified triple-branched stent graft is a reliable technique for acute Debakey type I aortic dissection as indicated by 2 years of follow-up.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Stents , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/mortalidade , China/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
9.
Interact Cardiovasc Thorac Surg ; 29(3): 331-338, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31220275

RESUMO

In the majority of patients presenting with acute type A aortic dissection (AAD) complicated by aortic valve insufficiency, the aortic valve (AV) can be preserved by AV resuspension. A meta-analysis was performed to investigate the outcomes following AV resuspension for AAD. A systematic literature search for publications reporting outcomes after AV resuspension in AAD published between January 1998 and June 2018 was conducted. Early outcome events and linearized occurrence rates for late outcome events were derived. The retrieval process yielded 18 unique studies involving 3295 patients with a total of 17 532 patient-years (pt-yrs). Pooled early mortality was 15.5% [95% confidence interval (95% CI) 11.5-19.4%, I2 = 91.9%], and the linearized late mortality rate was 3.21%/pt-yrs (95% CI 2.49-3.77, I2 = 29%). The linearized occurrence rates for aortic root reintervention was 1.4%/pt-yrs (95% CI 0.88-1.79, I2 = 48%); for recurrent significant aortic valve insufficiency (>2+), it was 1.12%/pt-yrs (95% CI 0.79-1.45, I2 = 68%); and for endocarditis, it was 0.01%/pt-yrs (95% CI 0-0.04, I2 = 7%). The composite rate of thromboembolism and bleeding was 1.41%/pt-yrs (95% CI 0.18-2.63, I2 = 82%). A more recent surgical period was associated with a decreased hazard of reoperation on the aortic root (P < 0.001). Requirement of AV resuspension alone in AAD is a risk factor for mortality. The long-term durability of AV resuspension is excellent, with low rates of endocarditis and thromboembolism and bleeding. Root reoperation hazard has become acceptable in recent years. Preoperative aortic valve insufficiency grade exceeding 2+ is a predictor for root reoperation.


Assuntos
Dissecção Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Dissecção Aórtica/complicações , Insuficiência da Valva Aórtica/etiologia , Humanos , Medidas de Resultados Relatados pelo Paciente , Reoperação
10.
Ann Thorac Cardiovasc Surg ; 24(6): 308-314, 2018 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-30058611

RESUMO

BACKGROUND: Perventricular and transcatheter device closures are performed for perimembranous ventricular septal defect (pmVSD) to reduce the surgical trauma of conventional surgical repair via median sternotomy. Few comparative studies have been conducted among these three procedures. METHODS: From June 2015 to May 2016, 247 patients with isolated pmVSD who had undergone perventricular or transcatheter device closure or conventional surgical repair were reviewed to compare these three procedures. RESULTS: The procedure success rate was similar in these three groups. There were a statistically significant difference in operative time, aortic cross-clamping time, duration of cardiopulmonary bypass (CPB), blood transfusion amount, and medical cost in these three groups. Meanwhile, postoperative mechanical ventilation time, duration of intensive care, and length of hospital stay were longer in surgical group than the other two groups. The surgical group required the longest incision. No significant difference was noted in major adverse events. There were different advantages and disadvantages in these three kinds of procedures. CONCLUSIONS: Device closure may be alternative to conventional surgical repair for patients with isolated pmVSD. Perventricular device closure was the preferred procedure because it showed more maneuverable than transcatheter procedure with the same clinical result.


Assuntos
Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/instrumentação , Comunicação Interventricular/terapia , Dispositivo para Oclusão Septal , Esternotomia , Transfusão de Sangue , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar , Pré-Escolar , Feminino , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Lactente , Recém-Nascido , Tempo de Internação , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Respiração Artificial , Fatores de Risco , Esternotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...