Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Card Surg ; 37(7): 1907-1914, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35385586

RESUMO

BACKGROUND: The European CE Mark approval study and the MOMENTUM 3 trial demonstrated safety and a reduction in hemocompatibility-related adverse events with the use of HeartMate 3 (HM3) device. This single-center study investigated the real-world experience in HM3 patients since FDA approval. METHODS: This retrospective, observational study included patients implanted with the HM3 LVAD as a primary implant between October 2017 and March 2020. Patients were divided into trial group and postapproval group. The primary endpoint was survival at 6 months. Secondary endpoints were adverse events including pump thrombosis (requiring pump exchange), stroke, renal failure, acute limb ischemia, re-exploratory for bleeding, gastrointestinal bleeding, right ventricular failure, and driveline infection. RESULTS: A total of 189 patients were implanted with HM3 device during the study period. 174 patients met the inclusion criteria: 82 patients in the trial group and 92 patients in the postapproval group. The postapproval group had younger patients, higher preoperative mean international normalized ratio, and greater numbers of patients with bridge to transplant (BTT) indications, IINTERMACS profile 1, and use of mechanical assist devices (other than IABP) than the trial group. Other characteristics between the two groups were comparable. Overall survival at 6 months in the postapproval group was 93.3% versus 93.8% (p = .88). The postapproval group demonstrated a statistically significant lower incidence of re-explorative surgery for bleeding (10.9% vs. 46.3, p = .01) than the trial group. CONCLUSION: In this single-center study, the real-world 6-month survival in the postapproval group was comparable to the trial results. Further studies are needed to monitor long-term outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
2.
J Card Surg ; 34(12): 1629-1631, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31609485

RESUMO

Right ventricular failure continues to be the Achilles heel in the management of heart failure patients. Traditionally, either high doses of inotropes and inhaled nitric oxide or jerry-rigged temporary mechanical devices have been used to support failing right ventricles. No durable implantable right ventricular assist device has been developed to address this long-standing concern. Because of this vacuum of innovation, surgeons have started using the third-generation LVADs to support the right ventricle. The HeartMate 3 (Abbott) LVAD is a safe and effective therapy for the management of biventricular failure.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Equipamento , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade
3.
Ochsner J ; 17(1): 66-70, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28331450

RESUMO

BACKGROUND: In cases of chronic thromboembolic pulmonary hypertension (CTEPH), referral for possible surgical intervention is important because surgery can be curative. Surgery necessitates cardiopulmonary bypass and deep circulatory arrest with pulmonary thrombectomy and bilateral endarterectomy (PTE). If surgery fails, lung transplant is the next best surgical option. Medical treatment is also an important adjunct. CASE REPORT: A 35-year-old female presented 3 months after a pulmonary embolus was found to be completely occluding her left pulmonary artery. She was found to have pulmonary hypertension with a pulmonary artery pressure of 81/33 mmHg, with a mean pressure of 52 mmHg. The right atrial pressure was also severely elevated at 29 mmHg, and her echocardiogram revealed severe tricuspid regurgitation and severe right ventricular dysfunction. She underwent PTE and postoperatively was followed by the heart failure team. Her 6-minute walk distance improved from 396 meters at 1 month to 670 meters at 7 months, and her pulmonary artery pressure improved significantly to 55/17 mmHg with a mean pressure of 31 mmHg. The patient's right atrial pressure also improved significantly from 29 mmHg to 13 mmHg. CONCLUSION: CTEPH is likely underrecognized, and patients with pulmonary hypertension or a history of pulmonary embolism should be screened for CTEPH. This case illustrates the surgical treatment for CTEPH and discusses alternative and adjunctive treatments. Residual pulmonary hypertension after PTE occurs in approximately 35% of patients. Overall, 4-year mortality rates after surgery appear to be approximately 15%, and mortality rates correlate with the postoperative pulmonary vascular resistance. Recognition of chronic pulmonary thromboembolic disease as the etiology of pulmonary hypertension warrants evaluation for surgery.