Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol Case Rep ; 36: 102025, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39175930

RESUMO

Purpose: Conjunctival melanoma is a rare neoplasm with high rates of recurrence and metastasis. Traditional management includes surgical excision and cryotherapy, followed by adjuvant therapy as needed. Immune checkpoint inhibitors, including nivolumab, are a targeted treatment option with improved survival rates. However, various immune-related adverse effects have been reported with these drugs. While systemic granulomatous inflammation is a documented systemic side effect, it has rarely been reported in the conjunctiva and ocular adnexa. Observation: A patient with a history of recurrent metastatic conjunctival melanoma presented with both a left sub-conjunctival and upper eyelid lesion after the commencement of treatment with nivolumab. The lesions were excised with a clinical suspicion for metastasis and consisted of noncaseating granulomatous inflammation with no evidence of malignancy on histopathologic examination. Infectious and primary autoimmune etiologies were ruled out. Conclusion and importance: This is a biopsy-proven case of periocular immune checkpoint inhibitor-associated granulomatous inflammation.

2.
Invest Ophthalmol Vis Sci ; 65(5): 17, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38717424

RESUMO

Purpose: We aimed to identify structural differences in normal eyes, early age-related macular degeneration (AMD), and intermediate AMD eyes using optical coherence tomography (OCT) in a well-characterized, large cross-sectional cohort. Methods: Subjects ≥ 60 years with healthy normal eyes, as well as early or intermediate AMD were enrolled in the Alabama Study on Age-related Macular Degeneration 2 (ALSTAR2; NCT04112667). Using Spectralis HRA + OCT2, we obtained macular volumes for each participant. An auto-segmentation software was used to segment six layers and sublayers: photoreceptor inner and outer segments, subretinal drusenoid deposits (SDDs), retinal pigment epithelium + basal lamina (RPE + BL), drusen, and choroid. After manually refining the segmentations of all B-scans, mean thicknesses in whole, central, inner and outer rings of the ETDRS grid were calculated and compared among groups. Results: This study involved 502 patients, 252 were healthy, 147 had early AMD, and 103 had intermediate AMD eyes (per Age-Related Eye Disease Study [AREDS] 9-step). Intermediate AMD eyes exhibited thicker SDD and drusen, thinner photoreceptor inner segments, and RPE compared to healthy and early AMD eyes. They also had thicker photoreceptor outer segments than early AMD eyes. Early AMD eyes had thinner photoreceptor outer segments than normal eyes but a thicker choroid than intermediate AMD eyes. Using the Beckman scale, 42% of the eyes initially classified as early AMD shifted to intermediate AMD, making thickness differences for photoreceptor outer segments and choroid insignificant. Conclusions: With AMD stages, the most consistent structural differences involve appearance of drusen and SDD, followed by RPE + BL thickness, and then thickness of photoreceptor inner and outer segments. Structural changes in the transition from aging to intermediate AMD include alterations in the outer retinal bands, including the appearance of deposits on either side of the RPE.


Assuntos
Corioide , Degeneração Macular , Drusas Retinianas , Epitélio Pigmentado da Retina , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Corioide/patologia , Corioide/diagnóstico por imagem , Estudos Transversais , Degeneração Macular/diagnóstico , Drusas Retinianas/diagnóstico , Segmento Externo das Células Fotorreceptoras da Retina/patologia , Epitélio Pigmentado da Retina/patologia , Epitélio Pigmentado da Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia
4.
Invest Ophthalmol Vis Sci ; 65(2): 1, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300559

RESUMO

Purpose: Lack of valid end points impedes developing therapeutic strategies for early age-related macular degeneration (AMD). Delayed rod-mediated dark adaptation (RMDA) is the first functional biomarker for incident early AMD. The relationship between RMDA and the status of outer retinal bands on optical coherence tomography (OCT) have not been well defined. This study aims to characterize these relationships in early and intermediate AMD. Methods: Baseline data from 476 participants was assessed including eyes with early AMD (n = 138), intermediate AMD (n = 101), and normal aging (n = 237). Participants underwent volume OCT imaging of the macula and rod intercept time (RIT) was measured. The ellipsoid zone (EZ) and interdigitation zone (IZ) on all OCT B-scans of the volumes were segmented. The area of detectable EZ and IZ, and mean thickness of IZ within the Early Treatment Diabetic Retinopathy Study (ETDRS) grid were computed and associations with RIT were assessed by Spearman's correlation coefficient and age adjusted. Results: Delayed RMDA (longer RIT) was most strongly associated with less preserved IZ area (r = -0.591; P < 0.001), followed by decreased IZ thickness (r = -0.434; P < 0.001), and EZ area (r = -0.334; P < 0.001). This correlation between RIT and IZ integrity was not apparent when considering normal eyes alone within 1.5 mm of the fovea. Conclusions: RMDA is correlated with the status of outer retinal bands in early and intermediate AMD eyes, particularly, the status of the IZ. This correlation is consistent with a previous analysis of only foveal B-scans and is biologically plausible given that retinoid availability, involving transfer at the interface attributed to the IZ, is rate-limiting for RMDA.


Assuntos
Macula Lutea , Degeneração Macular , Humanos , Degeneração Macular/diagnóstico , Retina , Fóvea Central , Biomarcadores , Nonoxinol
5.
Res Sq ; 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38045283

RESUMO

We present SLIViT, a deep-learning framework that accurately measures disease-related risk factors in volumetric biomedical imaging, such as magnetic resonance imaging (MRI) scans, optical coherence tomography (OCT) scans, and ultrasound videos. To evaluate SLIViT, we applied it to five different datasets of these three different data modalities tackling seven learning tasks (including both classification and regression) and found that it consistently and significantly outperforms domain-specific state-of-the-art models, typically improving performance (ROC AUC or correlation) by 0.1-0.4. Notably, compared to existing approaches, SLIViT can be applied even when only a small number of annotated training samples is available, which is often a constraint in medical applications. When trained on less than 700 annotated volumes, SLIViT obtained accuracy comparable to trained clinical specialists while reducing annotation time by a factor of 5,000 demonstrating its utility to automate and expedite ongoing research and other practical clinical scenarios.

6.
medRxiv ; 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37745353

RESUMO

Purpose: While intermediate and late age-Related Macular Degeneration (AMD) have been widely investigated, rare studies were focused on the pathophysiologic mechanism of early AMD. Delayed rod-mediated dark adaptation (RMDA) is the first functional biomarker for incident early AMD. The status of outer retinal bands on optical coherence tomography (OCT) may be potential imaging biomarkers and the purpose is to investigate the hypothesis that the integrity of interdigitation zone (IZ) may provide insight into the health of photoreceptors and retinal pigment epithelium (RPE) in early AMD. Methods: We establish the structure-function relationship between ellipsoid zone (EZ) integrity and RMDA, and IZ integrity and RMDA in a large-scale OCT dataset from eyes with normal aging (n=237), early AMD (n=138), and intermediate AMD (n=101) by utilizing a novel deep-learning-derived algorithm with manual correction when needed to segment the EZ and IZ on OCT B-scans (57,596 B-scans), and utilizing the AdaptDx device to measure RMDA. Results: Our data demonstrates that slower RMDA is associated with less preserved EZ (r = -0.334; p<0.001) and IZ area (r = -0.591; p<0.001), and decreased IZ thickness (r = -0.434; p<0.001). These associations are not apparent when considering normal eyes alone. Conclusions: The association with IZ area and RMDA in large-scale data is biologically plausible because retinoid availability and transfer at the interface attributed to IZ is rate-limiting for RMDA. This study supports the hypothesis that the IZ integrity provides insight into the health of photoreceptors and RPE in early AMD and is a potential new imaging biomarker.

7.
Analyst ; 141(7): 2259-69, 2016 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-26936406

RESUMO

A novel electrochemical sensing platform for nitrobenzene has been developed using silver nanoparticles (AgNPs) embedded in the poly(amic) acid (PAA) polymer matrix (PAA-AgNPs). PAA was synthesized via the polycondensation reaction of para-phenylenediamine and benzene-1,2,4,5-tetracarboxylic dianhydride. PAA-AgNP nanocomposites were synthesized by the in situ reduction of a silver precursor by the polymer at room temperature in a one-step approach without using an extraneous reducing or capping agent. The composite was subsequently characterized in solution and as a thin film. The X-ray diffraction technique revealed the crystalline nature of the PAA films with the embedded AgNPs. Unlike conventional polymers, the synthesized PAA membrane exhibits significant UV/Vis spectroscopic response. The sequestered nanoparticles also show the characteristic surface plasmon resonance (SPR) peaks confirming the presence of AgNPs. Integrated charge areas were 4.826 mC and 2.176 C for PAA/GC and PAA-AgNPs/GC respectively. The charge at the PAA-AgNP/GC electrode is 451 times greater than that at the PAA/GC electrode suggesting that the AgNP composite exhibits higher electroactivity. When tested as a sensor for nitrobenzene, the PAA-AgNP modified GC electrode showed promising potential as an electrochemical sensor. The electrochemical sensors exhibit a wide linear dynamic range (10-600 µM) with a correlation coefficient of 0.9735, a detection limit of 1.68 µM and a sensitivity of 7.88 µA µM(-1). The sensor also exhibited minimal interference effects on structurally-similar nitroaromatic compounds and metal species such as 4-nitroaniline (4-NA), 2-nitrophenol (2-NP), dinitrobenzene (DNB), Pb(2+) and Cd(2+).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA