Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Front Cardiovasc Med ; 11: 1336291, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38380178

RESUMO

Background: Evidence of the association between AMplitude Spectral Area (AMSA) of ventricular fibrillation and outcome after out-of-hospital cardiac arrest (OHCA) is limited to short-term follow-up. In this study, we assess whether AMSA can stratify the risk of death or poor neurological outcome at 30 days and 1 year after OHCA in patients with an initial shockable rhythm or with an initial non-shockable rhythm converted to a shockable one. Methods: This is a multicentre retrospective study of prospectively collected data in two European Utstein-based OHCA registries. We included all cases of OHCAs with at least one manual defibrillation. AMSA values were calculated after data extraction from the monitors/defibrillators used in the field by using a 2-s pre-shock electrocardiogram interval. The first detected AMSA value, the maximum value, the average value, and the minimum value were computed, and their outcome prediction accuracy was compared. Multivariable Cox regression models were run for both 30-day and 1-year deaths or poor neurological outcomes. Neurological cerebral performance category 1-2 was considered a good neurological outcome. Results: Out of the 578 patients included, 494 (85%) died and 10 (2%) had a poor neurological outcome at 30 days. All the AMSA values considered (first value, maximum, average, and minimum) were significantly higher in survivors with good neurological outcome at 30 days. The average AMSA showed the highest area under the receiver operating characteristic curve (0.778, 95% CI: 0.7-0.8, p < 0.001). After correction for confounders, the highest tertiles of average AMSA (T3 and T2) were significantly associated with a lower risk of death or poor neurological outcome compared with T1 both at 30 days (T2: HR 0.6, 95% CI: 0.4-0.9, p = 0.01; T3: HR 0.6, 95% CI: 0.4-0.9, p = 0.02) and at 1 year (T2: HR 0.6, 95% CI: 0.4-0.9, p = 0.01; T3: HR 0.6, 95% CI: 0.4-0.9, p = 0.01). Among survivors at 30 days, a higher AMSA was associated with a lower risk of mortality or poor neurological outcome at 1 year (T3: HR 0.03, 95% CI: 0-0.3, p = 0.02). Discussion: Lower AMSA values were significantly and independently associated with the risk of death or poor neurological outcome at 30 days and at 1 year in OHCA patients with either an initial shockable rhythm or a conversion rhythm from non-shockable to shockable. The average AMSA value had the strongest association with prognosis.

2.
J Invasive Cardiol ; 35(11)2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37992330

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) using the MitraClip (Abbott Vascular) system has emerged as a standard treatment for patients with symptomatic severe secondary or inoperable primary mitral regurgitation (MR). The relatively recent approval of the PASCAL Transcatheter Valve Repair System (Edwards Lifesciences) has expanded the options of TEER devices. However, evidence comparing PASCAL with MitraClip systems is still limited. METHODS: We conducted a systematic literature research and meta-analysis in PubMed, Medline, and EMBASE databases for studies comparing PASCAL and MitraClip systems. RESULTS: Four observational studies and 1 randomized controlled trial, involving 1315 patients total, were eligible for inclusion. All patients exhibited symptomatic (NYHA II-IV) MR grades 3+ or 4+. Baseline characteristics were comparable across all included studies. The clinical outcomes were assessed according to the Mitral Valve Academic Research Consortium consensus. The procedural success rates for the 2 devices were comparable in terms of achieving post-procedural MR grades of less than or equal to 2+ and less than or equal to 1+. Furthermore, most patients improved their clinical status, with no significant differences between patients treated with PASCAL and those treated with MitraClip. In terms of safety, both procedures exhibited low overall mortality rates and occurrence of major adverse events (MAE), without significant difference between the 2 devices. These findings remained consistent in both short- and long-term follow-up assessments. CONCLUSIONS: Our study revealed similar effectiveness and safety profiles between the PASCAL and MitraClip devices in patients experiencing significant symptomatic MR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
4.
Intern Emerg Med ; 18(8): 2397-2405, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37556074

RESUMO

The optimal energy for defibrillation has not yet been identified and very often the maximum energy is delivered. We sought to assess whether amplitude spectral area (AMSA) of ventricular fibrillation (VF) could predict low energy level defibrillation success in out-of-hospital cardiac arrest (OHCA) patients. This is a multicentre international study based on retrospective analysis of prospectively collected data. We included all OHCAs with at least one manual defibrillation. AMSA values were calculated by analyzing the data collected by the monitors/defibrillators used in the field (Corpuls 3 and Lifepak 12/15) and using a 2-s-pre-shock electrocardiogram interval. We run two different analyses dividing the shocks into three tertiles (T1, T2, T3) based on AMSA values. 629 OHCAs were included and 2095 shocks delivered (energy ranging from 100 to 360 J; median 200 J). Both in the "extremes analysis" and in the "by site analysis", the AMSA values of the effective shocks at low energy were significantly higher than those at high energy (p = 0.01). The likelihood of shock success increased significantly from the lowest to the highest tertile. After correction for age, call to shock time, use of mechanical CPR, presence of bystander CPR, sex and energy level, high AMSA value was directly associated with the probability of shock success [T2 vs T1 OR 3.8 (95% CI 2.5-6) p < 0.001; T3 vs T1 OR 12.7 (95% CI 8.2-19.2), p < 0.001]. AMSA values are associated with the probability of low-energy shock success so that they could guide energy optimization in shockable cardiac arrest patients.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Fibrilação Ventricular/terapia , Cardioversão Elétrica , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/complicações , Estudos Retrospectivos , Amsacrina , Eletrocardiografia
5.
J Clin Med ; 12(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445464

RESUMO

BACKGROUND: Devices for mechanical cardiopulmonary resuscitation (CPR) are recommended when high quality CPR cannot be provided. Different devices are available, but the literature is poor in direct comparison studies. Our aim was to assess whether the type of mechanical chest compressor could affect the probability of return of spontaneous circulation (ROSC) and 30-day survival in Out-of-Hospital Cardiac Arrest (OHCA) patients as compared to manual standard CPR. METHODS: We considered all OHCAs that occurred from 1 January 2015 to 31 December 2022 in seven provinces of the Lombardy region equipped with three different types of mechanical compressor: Autopulse®(ZOLL Medical, MA), LUCAS® (Stryker, MI), and Easy Pulse® (Schiller, Switzerland). RESULTS: Two groups, 2146 patients each (manual and mechanical CPR), were identified by propensity-score-based random matching. The rates of ROSC (15% vs. 23%, p < 0.001) and 30-day survival (6% vs. 14%, p < 0.001) were lower in the mechanical CPR group. After correction for confounders, Autopulse® [OR 2.1, 95%CI (1.6-2.8), p < 0.001] and LUCAS® [OR 2.5, 95%CI (1.7-3.6), p < 0.001] significantly increased the probability of ROSC, and Autopulse® significantly increased the probability of 30-day survival compared to manual CPR [HR 0.9, 95%CI (0.8-0.9), p = 0.005]. CONCLUSION: Mechanical chest compressors could increase the rate of ROSC, especially in case of prolonged resuscitation. The devices were dissimilar, and their different performances could significantly influence patient outcomes. The load-distributing-band device was the only mechanical chest able to favorably affect 30-day survival.

6.
J Am Heart Assoc ; 12(10): e027923, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37183852

RESUMO

Background Once the return of spontaneous circulation after out-of-hospital cardiac arrest is achieved, a 12-lead ECG is strongly recommended to identify candidates for urgent coronary angiography. ECG has no apparent role in mortality risk stratification. We aimed to assess whether ECG features could be associated with 30-day survival in patients with out-of-hospital cardiac arrest. Methods and Results All the post-return of spontaneous circulation ECGs from January 2015 to December 2018 in 3 European centers (Pavia, Lugano, and Vienna) were collected. Prehospital data were collected according to the Utstein style. A total of 370 ECGs were collected: 287 men (77.6%) with a median age of 62 years (interquartile range, 53-70 years). After correction for the return of spontaneous circulation-to-ECG time, age >62 years (hazard ratio [HR], 1.78 [95% CI, 1.21-2.61]; P=0.003), female sex (HR, 1.5 [95% CI, 1.05-2.13]; P=0.025), QRS wider than 120 ms (HR, 1.64 [95% CI, 1.43-1.87]; P<0.001), the presence of a Brugada pattern (HR, 1.49 [95% CI, 1.39-1.59]; P<0.001), and the presence of ST-segment elevation in >1 segment (HR, 1.75 [95% CI, 1.59-1.93]; P<0.001) were independently associated with 30-day mortality. A score ranging from 0 to 26 was created, and by dividing the population into 3 tertiles, 3 classes of risk were found with significantly different survival rate at 30 days (score 0-4, 73%; score 5-7, 66%; score 8-26, 45%). Conclusions The post-return of spontaneous circulation ECG can identify patients who are at high risk of mortality after out-of-hospital cardiac arrest earlier than other forms of prognostication. This provides important risk stratification possibilities in postcardiac arrest care that could help to direct treatments and improve outcomes in patients with out-of-hospital cardiac arrest.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/terapia , Angiografia Coronária/métodos , Taxa de Sobrevida , Eletrocardiografia/métodos , Reanimação Cardiopulmonar/métodos
7.
Front Cardiovasc Med ; 10: 1179815, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255711

RESUMO

Objective: Antiarrhythmic drugs are recommended for out of hospital cardiac arrest (OHCA) with shock-refractory ventricular fibrillation (VF). Amplitude Spectral Area (AMSA) of VF is a quantitative waveform measure that describes the amplitude-weighted mean frequency of VF, it correlates with intramyocardial adenosine triphosphate (ATP) concentration, it is a predictor of shock efficacy and an emerging indicator to guide defibrillation and resuscitation efforts. How AMSA might be influenced by amiodarone administration is unknown. Methods: In this international multicentre observational study, all OHCAs receiving at least one shock were included. AMSA values were calculated by retrospectively analysing the pre-shock ECG interval of 2 s. Multivariable models were run and a propensity score based on the probability of receiving amiodarone was created to compare two randomly matched samples. Results: 2,077 shocks were included: 1,407 in the amiodarone group and 670 in the non-amiodarone group. AMSA values were lower in the amiodarone group [8.8 (6-12.7) mV·Hz vs. 9.8 (6-14) mV·Hz, p = 0.035]. In two randomly matched propensity score-based groups of 261 shocks, AMSA was lower in the amiodarone group [8.2 (5.8-13.5) mV·Hz vs. 9.6 (5.6-11.6), p = 0.042]. AMSA was a predictor of shock success in both groups but the predictive power was lower in the amiodarone group [Area Under the Curve (AUC) non-amiodarone group 0.812, 95%CI: 0.78-0.841 vs. AUC amiodarone group 0.706, 95%CI: 0.68-0.73; p < 0.001]. Conclusions: Amiodarone administration was independently associated with the probability of recording lower values of AMSA. In patients who have received amiodarone during cardiac arrest the predictive value of AMSA for shock success is significantly lower, but still statistically significant.

8.
Am J Cardiovasc Drugs ; 23(3): 269-276, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37061614

RESUMO

BACKGROUND: Atrial fibrillation (AF) frequently complicates hypertrophic cardiomyopathy (HCM), and anticoagulation significantly decreases the risk of stroke in this population. To date, no randomized controlled trials (RCTs) have compared direct oral anticoagulants (DOACs) and vitamin K antagonists (VKAs). The present study aimed to systematically compare the two anticoagulation strategies in terms of effectiveness and safety. METHOD: We performed a systematic literature search and meta-analysis in the PubMed, MEDLINE, and EMBASE databases for studies reporting all-cause mortality, major bleeding, or thromboembolic events (TEs). Since no RCTs were available, we included observational studies only. The overall hazard ratio (HR) and 95% confidence interval (CI) for each analyzed parameter were pooled using a random-effects model. RESULTS: Five observational studies including 6919 patients were eligible for inclusion. Compared with VKAs, DOACs were associated with statistically significant lower rates of all-cause mortality (HR 0.64, 95% CI 0.35-0.54; p < 0.00001), comparable major bleeding events (HR 0.64, 95% CI 0.40-1.03; p = 0.07), and TEs (HR 0.94, 95% CI 0.73-1.22; p = 0.65). CONCLUSIONS: Compared with VKAs, a DOAC-based strategy might represent an effective and safe strategy regarding all-cause mortality, major/life-threatening bleeding complications, and TEs in HCM patients with concomitant AF. However, further prospective studies are necessary to reinforce a DOAC-based anticoagulation strategy in this population.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Hemorragia/tratamento farmacológico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/tratamento farmacológico , Cardiomiopatia Hipertrófica/induzido quimicamente , Administração Oral , Vitamina K
10.
Am Heart J ; 255: 94-105, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36272451

RESUMO

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Assuntos
Oclusão Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico , Angiografia Coronária , Infarto do Miocárdio/diagnóstico , Eletrocardiografia/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico
12.
Int J Cardiol ; 372: 76-79, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36496041

RESUMO

BACKGROUND AND AIM: Measurement of cardiac index (CI) is crucial in the hemodynamic assessment of critically ill patients in the intensive care unit (ICU). The most reliable trans-thoracic echocardiography (TTE) technique for CI estimation is the left ventricular outflow tract (LVOT) Doppler method that requires, among other parameters, the LVOT cross-sectional area (CSA) measurement. However, inherent and practical disadvantages, mostly related to the ICU setting, hamper LVOT-CSA assessment. In this study, we aimed to validate a simplified formula, leveraging on LVOT-velocity time integral (VTI) and heart rate (HR) only, for non-invasive estimation of CI in ICU patients. METHODS AND RESULTS: We prospectively enrolled 50 consecutive patients admitted to our ICU requiring pulmonary artery catheterization (PAC) over a one-year period. For each patient we measured the CI by PAC (CIPAC) and TTE. The latter was obtained both with the "traditional formula" (traditional CITTE), requiring LVOT-CSA assessment, and our new "simplified formula" (simplified CITTE). The correlation between the simplified CITTE and CIPAC was strong (r = 0.81) and resulted significantly greater than the traditional CITTE and CIPAC correlation (r = 0.70; p < 0.05 for Pearson r coefficients comparison). Both TTE-based CI showed an acceptable agreement (+0.19 ± 0.48 L/min/m2 for simplified CITTE and - 0.18 ± 0.58 L/min/m2 for traditional CITTE) with the reference CIPAC. CONCLUSION: In this study, we validated a practical approach, leveraging on TTE LVOT-VTI and HR only, for non-invasive estimation of CI in ICU patients.


Assuntos
Ecocardiografia , Unidades de Terapia Intensiva , Humanos , Hemodinâmica , Ultrassonografia Doppler , Cuidados Críticos , Reprodutibilidade dos Testes
13.
Int J Cardiol ; 365: 123-130, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35901908

RESUMO

BACKGROUND: Several patients undergoing transcatheter aortic valve replacement (TAVR) also require oral anticoagulation (OAC) for atrial fibrillation (AF) or deep vein thromboembolism. However, the optimal type of OAC strategy (direct oral anticoagulants, DOACs, or vitamin K antagonists, VKA) is still unclear in this setting. METHOD: We performed systematic literature research and meta-analysis in PubMed, Medline, and EMBASE databases for studies reporting either all-cause mortality, major/life-threatening bleeding or stroke events. RESULTS: Ten observational studies and two randomized controlled trials (RCTs) including a total of 29,485 patients were eligible for inclusion. Compared to VKA, DOACs use after TAVR was associated with a modest but significantly lower rates of all-cause mortality (RR 0.90; 95% CI: 0.81-0.99, p-value 0.04) with results mainly driven by observational studies. Cardiovascular mortality (RR 1.03; 95% CI: 0.81-1.30; p-value 0.84), total stroke events (RR 0.97; 95% CI: 0.76-1.23, p-value 0.79), major/life-threatening bleeding (RR 0.93; 95% CI: 0.72-1.21, p-value 0.61) and minor bleeding (RR 0.96; 95% CI: 0.74-1.23; p-value 0.72) were similar between VKA and DOACs. CONCLUSION: Considering the totality of available evidence, in patients who underwent TAVR with a concomitant indication for OAC, DOACs-based strategy is an effective and safe anticoagulation strategy compared to VKA.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrinolíticos/uso terapêutico , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Vitamina K
14.
J Cardiovasc Pharmacol ; 80(2): 180-186, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35580320

RESUMO

ABSTRACT: Postoperative atrial fibrillation (POAF) is a frequently reported postcardiac surgery complication leading to increased in-hospital and long-term mortality rates. Many randomized controlled trials (RCTs) have recently suggested using statins to protect against POAF. Therefore, we performed a systematic literature search and meta-analysis in electronic databases for eligible studies published between January 2006 and January 2022. The principal inclusion criteria were as follows: RCTs' study design, statin-naive patients, total study participants ≥50 units, and statin pretreatment started no more than 21 days before cardiac surgery. In the primary analysis, statin pretreatment reduced the incidence of POAF compared with placebo. Analyzing different molecules, atorvastatin was associated with lower incidence of POAF but rosuvastatin was not. We therefore performed a sensitivity analysis excluding RCTs affected by important risk of biases. Thus, studies whose participants were ≥199 were those eligible for the secondary analysis. No statistically significant difference between statin pretreatment and placebo (OR 0.87; 95% CI: 0.71-1.07, P = 0.18) as well as for atorvastatin (OR 0.88; 95% CI: 0.61-1.28; P = 0.48; I 2 = 84%) and rosuvastatin (OR 0.87; 95% CI: 0.68-1.12, P = 0.29) was observed. To conclude, statin pretreatment before cardiac surgery is not associated with a significant reduction in POAF occurrence.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Inibidores de Hidroximetilglutaril-CoA Redutases , Atorvastatina/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Rosuvastatina Cálcica/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...