Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioresour Bioprocess ; 11(1): 36, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38647805

RESUMO

Cell separation using microfluidics has become an effective method to isolate biological contaminants from bodily fluids and cell cultures, such as isolating bacteria contaminants from microalgae cultures and isolating bacteria contaminants from white blood cells. In this study, bacterial cells were used as a model contaminant in microalgae culture in a passive microfluidics device, which relies on hydrodynamic forces to demonstrate the separation of microalgae from bacteria contaminants in U and W-shaped cross-section spiral microchannel fabricated by defocusing CO2 laser ablation. At a flow rate of 0.7 ml/min in the presence of glycine as bacteria chemoattractant, the spiral microfluidics devices with U and W-shaped cross-sections were able to isolate microalgae (Desmodesmus sp.) from bacteria (E. coli) with a high separation efficiency of 92% and 96% respectively. At the same flow rate, in the absence of glycine, the separation efficiency of microalgae for U- and W-shaped cross-sections was 91% and 96%, respectively. It was found that the spiral microchannel device with a W-shaped cross-section with a barrier in the center of the channel showed significantly higher separation efficiency. Spiral microchannel chips with U- or W-shaped cross-sections were easy to fabricate and exhibited high throughput. With these advantages, these devices could be widely applicable to other cell separation applications, such as separating circulating tumor cells from blood.

2.
Biomed Microdevices ; 26(1): 11, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38236465

RESUMO

Quartz crystal microbalance (QCM) is a versatile sensing platform that has gained increasing attention for its use in bioapplications due to its high sensitivity, real-time measurement capabilities, and label-free detection. This article presents a portable QCM system for liquid biosensing that uses a modified Hartley oscillator to drive 14 mm-diameter commercial QCM sensors. The system is designed to be low-cost, easy to use, and highly sensitive, making it ideal for various bioapplications. A new flow cell design to deliver samples to the surface of the sensor has been designed, fabricated, and tested. For portability and miniaturization purposes, a micropump-based pumping system is used in the current system. The system has a built-in temperature controller allowing for accurate frequency measurements. In addition, the system can be used in benchtop mode. The capability of the present system to be used in liquid biosensing is demonstrated through an experimental test for sensitivity to changes in the viscosity of glycerol samples. It was found to have a sensitivity of 263.51 Hz/mPa.s using a 10 MHz QCM sensor. Future work regarding potential applications was suggested.


Assuntos
Glicerol , Técnicas de Microbalança de Cristal de Quartzo , Temperatura , Viscosidade
3.
Micromachines (Basel) ; 14(7)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37512651

RESUMO

Trapezoidal cross-sectional spiral microfluidic channels showed high resolution and throughput in cell separation in bio-applications. The main challenges are the complexity and high cost of the fabrication process of trapezoidal cross-sectional channels on the micro-scale. In this work, we present the application of grayscale in microfluidic channel design to overcome the complexity of the fabrication process. We also use direct engraving with a CO2 laser beam on polymethyl methacrylate (PMMA) material to drastically reduce the microfluidic chip's cost (to <30 cents) and fabrication time (to 20 min). The capability of the present fabrication methodology for cell sorting applications is demonstrated through experimental tests for the separation of white blood cells (WBCs) from whole blood at different dilution factors. The experimental results indicated that an 800 µL/min flow rate provided the optimal separation efficiency using the fabricated chip. A 90.14% separation efficiency at 1% hematocrit diluted blood sample was reported.

4.
Sensors (Basel) ; 23(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37420895

RESUMO

Acceleration-based sensors are widely used in indicating the severity of damage caused to structural buildings during dynamic events. The force rate of change is of interest when investigating the effect of seismic waves on structural elements, and hence the calculation of the jerk is necessary. For most sensors, the technique used for measuring the jerk (m/s3) is based on differentiating the time-acceleration signal. However, this technique is prone to errors especially in small amplitude and low frequency signals, and is deemed not suitable when online feedback is required. Here, we show that direct measurement of the jerk can be achieved using a metal cantilever and a gyroscope. In addition, we focus on the development of the jerk sensor for seismic vibrations. The adopted methodology optimized the dimensions of an austenitic stainless steel cantilever and enhanced the performance in terms of sensitivity and the jerk measurable range. We found, after several analytical and FE analyses, that an L-35 cantilever model with dimensions 35 × 20 × 0.5 (mm3) and a natural frequency of 139 (Hz) has a remarkable performance for seismic measurements. Our theoretical and experimental results show that the L-35 jerk sensor has a constant sensitivity value of 0.05 ((deg/s)/(G/s)) with ±2% error in the seismic frequency bandwidth of 0.1~40 (Hz) and for amplitudes in between 0.1 and 2 (G). Furthermore, the theoretical and experimental calibration curves show linear trends with a high correlation factor of 0.99 and 0.98, respectively. These findings demonstrate the enhanced sensitivity of the jerk sensor, which surpasses previously reported sensitivities in the literature.


Assuntos
Aceleração , Vibração , Simulação por Computador
5.
Micromachines (Basel) ; 10(10)2019 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-31600884

RESUMO

The formation of uniform droplets and the control of their size, shape and monodispersity are of utmost importance in droplet-based microfluidic systems. The size of the droplets is precisely tuned by the channel geometry, the surface interfacial tension, the shear force and fluid velocity. In addition, the fabrication technique and selection of materials are essential to reduce the fabrication cost and time. In this paper, for reducing the fabrication cost Polymethyl methacrylate (PMMA) sheet is used with direct write laser technique by VERSA CO2 laser VLS3.5. This laser writing technique gives minimum channel width of about 160   µ m , which limit miniaturizing the droplet. To overcome this, modification on double T-junction (DTJ) channel geometry has been done by modifying the channel inlets angles. First, a two-dimensional (2D) simulation has been done to study the effect of the new channel geometry modification on droplet size, droplets distribution inside the channel, and its throughput. The fabricated modified DTJ gives the minimum droplet diameter of 39 ± 2   µ m , while DTJ channel produced droplet diameter of 48 ± 4   µ m at the same conditions. Moreover, the modified double T-junction (MDTJ) decreases the variation in droplets diameter at the same flow rates by 4.5 - 13 % than DTJ. This low variation in the droplet diameter is suitable for repeatability of the DNA detection results. The MDTJ also enhanced the droplet generation frequency by 8 - 25 % more than the DTJ channel. The uniformity of droplet distribution inside the channel was enhanced by 3 - 20 % compared to the DTJ channel geometry. This fabrication technique eliminates the need for a photomask and cleanroom environment in addition shortening the cost and time. It takes only 20   min for fabrication. The minimum generated droplet diameter is within 40   µ m with more than 1000 droplets per second (at 10   mL / h . oil flow rate). The device is a high-throughput and low-cost micro-droplet formation aimed to be as a front-end to a dynamic droplet digital PCR (ddPCR) platform for use in resource-limited environment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...