Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(6): 062702, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38394565

RESUMO

The cross section of the ^{13}C(α,n)^{16}O reaction is needed for nuclear astrophysics and applications to a precision of 10% or better, yet inconsistencies among 50 years of experimental studies currently lead to an uncertainty of ≈15%. Using a state-of-the-art neutron detection array, we have performed a high resolution differential cross section study covering a broad energy range. These measurements result in a dramatic improvement in the extrapolation of the cross section to stellar energies potentially reducing the uncertainty to ≈5% and resolving long standing discrepancies in higher energy data.

2.
Phys Rev Lett ; 131(22): 221801, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38101357

RESUMO

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ^{127}I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of 9.2_{-1.8}^{+2.1}×10^{-40} cm^{2}. This corresponds to a value that is ∼41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on ^{127}I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be 5.2_{-3.1}^{+3.4}×10^{-40} and 2.2_{-0.5}^{+0.4}×10^{-40} cm^{2}, respectively.

3.
Phys Rev Lett ; 130(21): 212701, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37295108

RESUMO

The rate of the final step in the astrophysical αp process, the ^{34}Ar(α,p)^{37}K reaction, suffers from large uncertainties due to a lack of experimental data, despite having a considerable impact on the observable light curves of x-ray bursts and the composition of the ashes of hydrogen and helium burning on accreting neutron stars. We present the first direct measurement constraining the ^{34}Ar(α,p)^{37}K reaction cross section, using the Jet Experiments in Nuclear Structure and Astrophysics gas jet target. The combined cross section for the ^{34}Ar,Cl(α,p)^{37}K,Ar reaction is found to agree well with Hauser-Feshbach predictions. The ^{34}Ar(α,2p)^{36}Ar cross section, which can be exclusively attributed to the ^{34}Ar beam component, also agrees to within the typical uncertainties quoted for statistical models. This indicates the applicability of the statistical model for predicting astrophysical (α,p) reaction rates in this part of the αp process, in contrast to earlier findings from indirect reaction studies indicating orders-of-magnitude discrepancies. This removes a significant uncertainty in models of hydrogen and helium burning on accreting neutron stars.


Assuntos
Hélio , Hidrogênio , Modelos Estatísticos , Nêutrons
4.
Phys Rev Lett ; 130(5): 051803, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800477

RESUMO

The COHERENT Collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220 MeV/c^{2} using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9 keV_{nr}. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6 kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants α_{D}<0.64, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

5.
Phys Rev Lett ; 129(8): 081801, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36053683

RESUMO

We measured the cross section of coherent elastic neutrino-nucleus scattering (CEvNS) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source at Oak Ridge National Laboratory. New data collected before detector decommissioning have more than doubled the dataset since the first observation of CEvNS, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT Collaboration determined the cross section to be (165_{-25}^{+30})×10^{-40} cm^{2}, consistent with the standard model, giving the most precise measurement of CEvNS yet. The timing structure of the neutrino beam has been exploited to compare the CEvNS cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino nonstandard interactions while testing lepton flavor universality and measures the weak mixing angle as sin^{2}θ_{W}=0.220_{-0.026}^{+0.028} at Q^{2}≈(50 MeV)^{2}.

6.
Rev Sci Instrum ; 93(5): 053103, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649763

RESUMO

This paper describes the development of a pulsed light source using the discharge from an electrode in a medium of various noble gases. This source can be used to aid in the characterization and testing of new vacuum-ultraviolet sensitive light detection devices. The source includes a novel spark driver circuit, a spark chamber into which different noble gases can be introduced, and an optical attenuation cell capable of being filled with different gases to allow for the attenuation of the pulsed light down to single photon levels. We describe the construction, calibration, and characterization of this device deployed at a dedicated light detection test stand at Oak Ridge National Laboratory.

7.
Phys Rev Lett ; 126(1): 012002, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480779

RESUMO

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10^{-39} cm^{2}-consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

8.
Phys Rev Lett ; 125(6): 062501, 2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32845657

RESUMO

Precise antineutrino measurements are very sensitive to proper background characterization. We present an improved measurement of the ^{13}C(α,n)^{16}O reaction cross section which constitutes significant background for large ν[over ¯] detectors. We greatly improve the precision and accuracy by utilizing a setup that is sensitive to the neutron energies while making measurements of the excited state transitions via secondary γ-ray detection. Our results shows a 54% reduction in the background contributions from the ^{16}O(3^{-},6.13 MeV) state used in the KamLAND analysis.

9.
Curr Oncol ; 27(3): e271-e275, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32669933

RESUMO

Background: Despite universal access to health care in Canada, there are disparities relating to social determinants of health that contribute to discrepancies between rural and urban areas in cancer incidence and outcomes. Given that Canada has one of the highest-quality national population-based cancer registry systems in the world and that little information is available about cancer statistics specific to northwestern Ontario, the purpose of the present study was to estimate the percentage of cancer patients without documentation of a specialist consultation (medical or radiation oncology consultation) and to determine factors that affect access to specialist consultation in northwestern Ontario. Methods: This population-based retrospective study used administrative data obtained through the Ontario Cancer Data Linkage Project. For each index case, a timeline was constructed of all Ontario Health Insurance Plan billing codes and associated service dates, starting with the primary cancer diagnosis and ending with death. Specific factors affecting access to specialist consultation were assessed. Results: Within the 6-year study period (2010-2016), 2583 index cases were identified. Most (n = 2007, 78%) received a specialist consultation. Factors associated with not receiving a specialist consultation included older age [p < 0.0001; odds ratio (or): 0.29; 95% confidence interval (ci): 0.19 to 0.44] and rural residence (p < 0.0001; or: 0.48; 95% ci: 0.48 to 0.72). Factors associated with receiving a specialist consultation included a longer timeline (p < 0.0001; or: 1.32; 95% ci: 1.19 to 1.46), a diagnosis of breast cancer (p < 0.0001; or: 2.51; 95% ci: 1.43 to 4.42), and a diagnosis of lung cancer (p < 0.0001; or: 1.77; 95% ci: 1.38 to 2.26). Conclusions: This study is the first to look at care access in northwestern Ontario. The complexity and multidisciplinary nature of cancer care makes the provision of appropriate care a challenge; a one-size-fits-all disease prevention and treatment strategy might not be appropriate.


Assuntos
Neoplasias/terapia , Adulto , Análise de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ontário
10.
Phys Rev Lett ; 122(25): 251801, 2019 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-31347897

RESUMO

This Letter reports the first measurement of the ^{235}U ν[over ¯]_{e} energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9 m from the 85 MW_{th} highly enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678±304(stat) ν[over ¯]_{e}-induced inverse beta decays, the largest sample from HEU fission to date, 99% of which are attributed to ^{235}U. Despite broad agreement, comparison of the Huber ^{235}U model to the measured spectrum produces a χ^{2}/ndf=51.4/31, driven primarily by deviations in two localized energy regions. The measured ^{235}U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν[over ¯]_{e} energy region of 5-7 MeV.

11.
Phys Rev Lett ; 122(5): 052701, 2019 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-30822026

RESUMO

Detection of nuclear-decay γ rays provides a sensitive thermometer of nova nucleosynthesis. The most intense γ-ray flux is thought to be annihilation radiation from the ß^{+} decay of ^{18}F, which is destroyed prior to decay by the ^{18}F(p,α)^{15}O reaction. Estimates of ^{18}F production had been uncertain, however, because key near-threshold levels in the compound nucleus, ^{19}Ne, had yet to be identified. We report the first measurement of the ^{19}F(^{3}He,tγ)^{19}Ne reaction, in which the placement of two long-sought 3/2^{+} levels is suggested via triton-γ-γ coincidences. The precise determination of their resonance energies reduces the upper limit of the rate by a factor of 1.5-17 at nova temperatures and reduces the average uncertainty on the nova detection probability by a factor of 2.1.

12.
PLoS One ; 14(1): e0210101, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30682060

RESUMO

Recognizing evolutionary trends in phenotypic means and rates requires the application of phylogenetic comparative methods (PCMs). Most PCMs are unsuited to make full use of fossil information, which is a drawback, given the inclusion of such data improves, and in some cases even corrects, the proper understanding of trait evolution. Here we present a new computer application, written in R, that allows the simultaneous computation of temporal trends in phenotypic mean and evolutionary rate along a phylogeny, and to contrast such patterns among different clades within the tree. By using simulation experiments, we show the new implementation, names search.trend is as powerful as existing PCM tools in discerning macroevolutionary patterns in phenotypic means and rates, but differently from any other PCM allows comparing individual clades to each other, and provides rich information about trait evolution for all lineages in the tree.


Assuntos
Evolução Biológica , Biologia Computacional/métodos , Extinção Biológica , Fósseis , Filogenia , Algoritmos , Fenótipo , Software
13.
Sci Rep ; 8(1): 7340, 2018 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-29743608

RESUMO

Members of the hominins - namely the so-called 'australopiths' and the species of the genus Homo - are known to possess short and deep mandibles and relatively small incisors and canines. It is commonly assumed that this suite of traits evolved in early members of the clade in response to changing environmental conditions and increased consumption of though food items. With the emergence of Homo, the functional meaning of mandible shape variation is thought to have been weakened by technological advancements and (later) by the control over fire. In contrast to this expectation, we found that mandible shape evolution in hominins is exceptionally rapid as compared to any other primate clade, and that the direction and rate of shape change (from the ape ancestor) are no different between the australopiths and Homo. We deem several factors including the loss of honing complex, canine reduction, and the acquisition of different diets may have concurred in producing such surprisingly high evolutionary rates. This study reveals the evolution of mandibular shape in hominins has strong morpho-functional and ecological significance attached.


Assuntos
Hominidae/anatomia & histologia , Hominidae/fisiologia , Mandíbula/anatomia & histologia , Animais , Evolução Biológica , Fósseis , Humanos , Mandíbula/patologia
14.
Phys Rev Lett ; 121(25): 251802, 2018 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-30608854

RESUMO

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of ^{235}U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton ^{6}Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 m water equivalent overburden. Data collected during 33 live days of reactor operation at a nominal power of 85 MW yield a detection of 25 461±283 (stat) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5σ statistical significance within 2 h of on-surface reactor-on data taking. A reactor model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the reactor antineutrino anomaly at 2.2σ confidence level.

15.
Science ; 357(6356): 1123-1126, 2017 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-28775215

RESUMO

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross section is by far the largest of all low-energy neutrino couplings. This mode of interaction offers new opportunities to study neutrino properties and leads to a miniaturization of detector size, with potential technological applications. We observed this process at a 6.7σ confidence level, using a low-background, 14.6-kilogram CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the standard model for this process, were observed in high signal-to-background conditions. Improved constraints on nonstandard neutrino interactions with quarks are derived from this initial data set.

16.
Curr Oncol ; 22(4): 246-51, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26300662

RESUMO

BACKGROUND: Cancer is a health concern in Inuit populations. Unique cultural, dietary, and genetic factors and geographic isolation influence cancer epidemiology in this group. Inuit-specific data about oncology treatments and survival outcomes in Canadian Inuit referred to urban treatment centres are lacking. METHODS: A retrospective chart review of Inuit patients referred to The Ottawa Hospital Cancer Centre (tohcc) from the Baffin region of Nunavut between 2000 and 2010 was conducted. Nunavut cancer registry data were used to establish the percentage of cancer cases referred and their survival outcomes. RESULTS: Of 307 cancer patients registered among Baffin-region Inuit, 216 [70% (63 men, 153 women)] were referred to tohcc for chemotherapy (ct) and radiation therapy (rt). Mean age in the referred group was 59.3 years (range: 25-89 years), and current smokers constituted half the group (52%). The cancers most commonly leading to referral in men were lung (55%), colorectal (19%), and nasopharyngeal (11%) cancers; in women, they were lung (46%), colorectal (24%), breast (10%), nasopharyngeal (6%), and cervical (5%) cancers. Of the 216 referred patients, 82 (38%) had already undergone surgery, and 18 (8%) received chemoradiation or rt only, all given with curative intent. Among the surgical patients referred, 33 (40%) and 23 (28%) went on to receive adjuvant ct and adjuvant rt respectively. Among 116 patients referred for palliative care, 64 (55%) received ct, 76 (66%) received rt, 43 (37%) received both ct and rt, and 19 (16%) received neither treatment. Median all-stage overall survival was 10 months for patients with lung cancer [95% confidence interval: 6.1 to 13.9 months] and 37 months for patients with colorectal cancer [95% confidence interval: 14.8 to 59.2 months]. CONCLUSIONS: High uptake of palliative and adjuvant ct and rt was observed in the Inuit patients referred to tohcc. Lung cancer was the most common cancer in referred Inuit men and women. The survival rates for Inuit lung cancer patients referred to tohcc were comparable to those in the rest of Canada. Further research is required to understand reasons for non-referral of Canadian Inuit to tohcc.

17.
Phys Rev Lett ; 107(9): 092701, 2011 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-21929233

RESUMO

Fusion cross sections were measured for the exotic proton-halo nucleus 8B incident on a 58Ni target at several energies near the Coulomb barrier. This is the first experiment to report on the fusion of a proton-halo nucleus. The resulting excitation function shows a striking enhancement with respect to expectations for normal projectiles. Evidence is presented that the sum of the fusion and breakup yields saturates the total reaction cross section.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...