Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38386144

RESUMO

Microbial fuel cells (MFCs) are a promising technology for obtaining energy in wastewater. Effective extracellular electron transfer is one of the key factors for its practical application. In this work, carbon dots (CDs) enriched with oxygen-containing groups on the surface were synthesized as an efficient anode modifier using a simple hydrothermal method and common reactants. The experimental findings indicated that anodes modified with CDs exhibited increased electrical conductivity and greater hydrophilicity. These modifications facilitated increased microorganism loading and contributed to enhancing electrochemical processes within the anode biofilm. The CD-modified MFCs exhibited higher maximum power density (661.1 ± 42.6 mW·m-2) and open-circuit voltage (534.50 ± 6.4 mV), which were significantly better than those of the blank group MFCs (484.1 ± 14.1 mW·m-2 and 447.50 ± 12.1 mV). The use of simple carbon materials to improve the microbial loading on the MFCs anode and the electron transfer between the microbial-electrode may provide a new idea for the design of efficient MFCs.

2.
Tree Physiol ; 43(7): 1233-1249, 2023 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-37017317

RESUMO

Long noncoding ribonucleic acids (lncRNAs) play crucial roles in regulating key biological processes; however, our knowledge of lncRNAs' roles in plant adaptive evolution is still limited. Here, we determined the divergence of conserved lncRNAs in closely related poplar species that were either tolerant or sensitive to salt stress by comparative transcriptome analysis. Among the 34,363 identified lncRNAs, ~3% were shared among poplar species with conserved sequences but diversified in their function, copy number, originating genomic region and expression patterns. Further cluster analysis revealed that the conserved lncRNAs showed more similar expression patterns within salt-tolerant poplars (Populus euphratica and P. pruinosa) than between salt-tolerant and salt-sensitive poplars. Among these lncRNAs, the antisense lncRNA lncERF024 was induced by salt and the differentiated expression between salt-sensitive and salt-tolerant poplars. The overexpression of lncERF024 in P. alba var. pyramidalis enhanced poplar tolerance to salt stress. Furthermore, RNA pull-down and RNA-seq analysis showed that numerous candidate genes or proteins associated with stress response and photosynthesis might be involved in salt resistance in PeulncERF024-OE poplars. Altogether, our study provided a novel insight into how the diversification of lncRNA expression contributes to plant adaptation traits and showed that lncERF024 may be involved in the regulation of both gene expression and protein function conferring salt tolerance in Populus.


Assuntos
Populus , RNA Longo não Codificante , Transcriptoma , RNA Longo não Codificante/genética , Populus/genética , Perfilação da Expressão Gênica , Estresse Salino/genética , Regulação da Expressão Gênica de Plantas , Estresse Fisiológico/genética
3.
ACS Appl Mater Interfaces ; 15(1): 1234-1246, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36578164

RESUMO

The efficient and durable oxygen reduction reaction (ORR) catalyst is of great significance to boost power generation and pollutant degradation in microbial fuel cells (MFCs). Although transition metal-nitrogen-codoped carbon materials are an important class of ORR catalysts, copper-nitrogen-codoped carbon is not considered a suitable MFC cathode catalyst due to the insufficient performance and especially instability. Herein, we report a three-dimensional (3D) hierarchical porous copper, nitrogen, and boron codoped carbon (3DHP Cu-N/B-C) catalyst synthesized by the dual template method. The introduced B atom as an electron donor increases the electron density around the Cu-Nx active site, which significantly promotes the efficiency of the ORR process and stabilizes the active site by preventing demetallization. Thus, the 3DHP Cu-N/B-C catalyst exhibited excellent ORR performance with the half-wave potential of 0.83 V (vs reversible hydrogen electrode (RHE)) in a 0.1 M KOH electrolyte and 0.68 V (vs RHE) in a 50 mM PBS electrolyte. Meanwhile, 3DHP Cu-N/B-C had satisfactory stability with 94.16% current retention after 24 h of chronoamperometry test, which is better than that of 20% Pt/C. The MFCs using 3DHP Cu-N/B-C not only showed a maximum power density of up to 760.14 ± 19.03 mW m-2 but also operating durability of more than 50 days. Moreover, the 16S rDNA sequencing results presented that the 3DHP Cu-N/B-C catalyst had a positive effect on the microbial community of the MFC with more anaerobic electroactive bacteria in the anode biofilm and fewer aerobic bacteria in the cathode biofilm. This study provides a new approach for the development of Cu-based ORR electrocatalysts as well as guidance for the rational design of high-performance MFCs.


Assuntos
Fontes de Energia Bioelétrica , Fontes de Energia Bioelétrica/microbiologia , Domínio Catalítico , Cobre , Oxirredução , Oxigênio/química , Carbono/química , Catálise , Nitrogênio/química
4.
Acta Haematol ; 145(1): 63-71, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34284381

RESUMO

INTRODUCTION: Autoimmune hemolytic anemia is a potentially lethal disease characterized by autoimmune hemolysis. Although human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) have been reported as a promising therapy, there is limited evidence regarding warm autoimmune hemolytic anemia (wAIHA) patients. This study aimed to investigate the potential therapeutic effects of hUC-MSCs via immune regulation in wAIHA patients. METHODS: Peripheral blood mononuclear cells (PBMCs) from 10 wAIHA patients and 8 healthy controls were isolated from peripheral blood and cultured for 3 days with or without the presence of hUC-MSCs; PBMCs were co-cultured with hUC-MSCs using Transwell assays. The supernatant cytokine levels were measured after culture through AimPlex Multiple Immunoassays for Flow, including IL-2, IL-4, IL-10, IFN-γ, TNF-α, and IL-17A. The percentages of regulatory T cells, regulatory B cells, and Th1/Th2 in PBMCs were also assessed before and after culturing. RESULTS: In the wAIHA group, hUC-MSCs could upregulate the Treg and Breg proportions after culturing for 3 days, and the Treg and Breg percentages increased after co-culturing with hUC-MSCs in the wAIHA group compared with PBMC cultured alone for 3 days (8.29 ± 8.59 vs. 6.82 ± 1.32, 3.82 ± 1.87 vs. 1.75 ± 1.20, respectively). Compared with the PBMC wAIHA group, the levels of TNF-α (2.13 ± 2.07 vs. 16.20 ± 21.13 pg/mL, p = 0.019) and IL-10 (10.51 ± 18.42 vs. 37.78 ± 44.20 pg/mL, p = 0.012) were significantly elevated in the PBMC + hUC-MSCs wAIHA group. CONCLUSION: The hUC-MSCs contributed to the increasing proportion of regulatory cell populations in PBMCs of wAIHA patients, thereby potentially regulating autoimmune response; thus, hUC-MSCs may be a promising approach for wAIHA treatment.


Assuntos
Anemia Hemolítica Autoimune/imunologia , Citocinas/imunologia , Imunomodulação , Linfócitos/imunologia , Células-Tronco Mesenquimais/imunologia , Cordão Umbilical/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anemia Hemolítica Autoimune/patologia , Técnicas de Cocultura , Feminino , Humanos , Linfócitos/patologia , Masculino , Células-Tronco Mesenquimais/patologia , Pessoa de Meia-Idade , Cordão Umbilical/patologia
5.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 29(4): 1301-1307, 2021 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-34362520

RESUMO

OBJECTIVE: To understand the characteristics of patients with mimicking specificity autoantibodies through the analysis of the causes of autoantibodies, specificity of antibodies, strategy of blood transfusion, effect of transfusion and distribution of antibodies in China and abroad. METHODS: A total of 23 patients who applied for blood in our hospital from January 2017 to June 2019 were identified as mimicking specificity autoantibodies by antibody identification or absorption-elution test. The causes of mimicking specificity autoantibodies, antibody specificity, blood transfusion strategy and blood transfusion effect were analyzed. The relevant articles on antibodies published in China and abroad were summarized and sorted out, and the distribution of antibodies was analyzed. RESULTS: All the 23 patients with mimicking specificity autoantibodies were Rh blood group system antibodies, of which mimicking anti-Ce autoantibodies were the most common (34.8%), followed by mimicking anti-e autoantibodies (26.1%), mimicking anti-D autoantibodies (21.7%), mimicking anti-C autoantibodies (8.7%) and mimicking anti-E autoantibodies (8.7%). Except for 2 cases with suspected history of blood transfusion, the other 21 cases had a history of blood transfusion / pregnancy. The most common cause of mimicking autoantibodies was drug, followed by infection and autoimmune diseases. The hemoglobin (Hb) of pretransfusion in the blood transfusion group was (48.4±23.9) g/L, which was significantly lower than (86.0±38.9) g/L in the non-transfusion group (P<0.01). Except for 2 cases who could not evaluate the effect of blood transfusion, the effective rate of transfusion was 100%. According to the retrospective statistics of 32 related articles published in China and abroad, the most type of mimicking antibodies were in Rh blood group system, accounting for 79.28%, among which anti-E was the main part of all mimicking autoantibodies, accounting for 21.95%. The following ones were in Kidd system MNSs system, and Kell system. CONCLUSION: Combined with the clinical symptoms and the degree of difficulty of blood matching, the best strategy of blood transfusion should be selected to ensure the safety of blood transfusion.


Assuntos
Antígenos de Grupos Sanguíneos , Isoanticorpos , Autoanticorpos , Transfusão de Sangue , Feminino , Humanos , Gravidez , Estudos Retrospectivos
6.
Mil Med Res ; 8(1): 33, 2021 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-34024283

RESUMO

BACKGROUND: The vital signs of trauma patients are complex and changeable, and the prediction of blood transfusion demand mainly depends on doctors' experience and trauma scoring system; therefore, it cannot be accurately predicted. In this study, a machine learning decision tree algorithm [classification and regression tree (CRT) and eXtreme gradient boosting (XGBoost)] was proposed for the demand prediction of traumatic blood transfusion to provide technical support for doctors. METHODS: A total of 1371 trauma patients who were diverted to the Emergency Department of the First Medical Center of Chinese PLA General Hospital from January 2014 to January 2018 were collected from an emergency trauma database. The vital signs, laboratory examination parameters and blood transfusion volume were used as variables, and the non-invasive parameters and all (non-invasive + invasive) parameters were used to construct an intelligent prediction model for red blood cell (RBC) demand by logistic regression (LR), CRT and XGBoost. The prediction accuracy of the model was compared with the area under the curve (AUC). RESULTS: For non-invasive parameters, the LR method was the best, with an AUC of 0.72 [95% confidence interval (CI) 0.657-0.775], which was higher than the CRT (AUC 0.69, 95% CI 0.633-0.751) and the XGBoost (AUC 0.71, 95% CI 0.654-0.756, P < 0.05). The trauma location and shock index are important prediction parameters. For all the prediction parameters, XGBoost was the best, with an AUC of 0.94 (95% CI 0.893-0.981), which was higher than the LR (AUC 0.80, 95% CI 0.744-0.850) and the CRT (AUC 0.82, 95% CI 0.779-0.853, P < 0.05). Haematocrit (Hct) is an important prediction parameter. CONCLUSIONS: The classification performance of the intelligent prediction model of red blood cell transfusion in trauma patients constructed by the decision tree algorithm is not inferior to that of the traditional LR method. It can be used as a technical support to assist doctors to make rapid and accurate blood transfusion decisions in emergency rescue environment, so as to improve the success rate of patient treatment.


Assuntos
Transfusão de Sangue/métodos , Eritrócitos , Previsões/métodos , Ferimentos e Lesões/terapia , Adulto , Área Sob a Curva , Transfusão de Sangue/estatística & dados numéricos , China , Técnicas de Apoio para a Decisão , Árvores de Decisões , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Ferimentos e Lesões/fisiopatologia
7.
Transfus Med ; 31(4): 262-270, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34028930

RESUMO

BACKGROUND: The paucity of accurate quantitative standards for determining the quantity of red blood cells (RBCs) needed for perioperative patients and the predominant application of the "preoperative hemoglobin + surgery type" empirical decision-making model have led to widespread RBC application problems. OBJECTIVE: The mathematical model of preoperative variables constructed by machine learning (ML) methods can help doctors decide preoperative RBC applications. METHODS: We retrospectively analysed 130 996 records of patients who received surgery in our hospital from January 2011 to June 2017. Through the analysis of multiple preoperative parameters that may affect the RBC transfusion volume, we used ML algorithms to build up the artificial intelligence (AI) model to predict the accurate RBC demand quantity and compared each result with those predicted by clinicians. RESULTS: Among the seven ML algorithms, the light gradient boosting machine (Lightgbm) algorithm was the best. The AI model predicted whether the patients needed RBC transfusion, and the area under curve (AUC) was 0.908 (95% CI 0.907-0.913). The AI model was more accurate than doctors in predicting RBC of 0, 2, and 4 units (85% data), with RMSEs of 1.61 vs. 2.15, 1.06 vs. 1.21, and 1.46 vs. 1.68, respectively. However, the AI model was not better than doctors in 1, 3, 5-6, 7-8, and 9-10 units (15% data), with RMSEs of 0.92 vs. 0.89, 0.92 vs. 0.89, 2.73 vs. 1.94, 4.53 vs. 3.92, and 6.26 vs. 5.08, respectively. CONCLUSION: Through the comparison of seven ML methods, the Lightgbm algorithm-based model is more accurate than clinician experience-based in predicting preoperative RBC transfusion, which reduces the risk of untimely blood supply caused by insufficient preoperative blood preparation, and reduces the unnecessary cost of blood compatibility testing caused by excessive preoperative blood preparation.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Transfusão de Sangue , Eritrócitos , Humanos , Estudos Retrospectivos
8.
Indian J Hematol Blood Transfus ; 37(1): 126-133, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33707845

RESUMO

It is difficult to predict RBC consumption accurately. This paper aims to use big data to establish a XGBoost Model to understand the trend of RBC accurately, and forecast the demand in time. XGBoost, which implements machine learning algorithms under the Gradient Boosting framework can provide a parallel tree boosting. The daily RBC usage and inventory (May 2014-September 2017) were investigated, and rules for RBC usage were analysed. All data were divided into training sets and testing sets. A XGBoost Model was established to predict the future RBC demand for durations ranging from a day to a week. In addition, the alert range was added to the predicted value to ensure RBC demand of emergency patients and surgical accidents. The gap between RBC usage and inventory was fluctuant, and had no obvious rule. The maximum residual inventory of a certain blood group was up to 700 units one day, while the minimum was nearly 0 units. Upon comparing MAE (mean absolute error):A:10.69, B:11.19, O:10.93, and AB:5.91, respectively, the XGBoost Model was found to have a predictive advantage over other state-of-the-art approaches. It showed the model could fit the trend of daily RBC usage. An alert range could manage the demand of emergency patients or surgical accidents. The model had been built to predict RBC demand, and the alert range of RBC inventory is designed to increase the safety of inventory management.

9.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 28(3): 904-908, 2020 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-32552956

RESUMO

OBJECTIVE: To evaluate the characteristics of autoimmune hemolytic anemia caused by salvianolate by antibody detection and clinical index monitoring. METHODS: Micro-column gel anti-human globulin method was used for irregular antibody screening and antibody identification. Salvianolate, sodium creatine phosphate and levocarnitine were used to sensitize red blood cells that were compatible with the patient's plasma, and the RBCs were used to test drug antibody in patient plasma respectively. The patient's clinical examination of hemolysis index and blood transfusion effect were analyed retrospectively. RESULTS: The patients were positive for irregular antibody screening, and there were antoanti-Ce antibodies in serum. The erythrocytes sensitized with salvianolate in the patient's serum were positive, while those sensitized with sodium creatine phosphate and levocarnitine were negative. CONCLUSION: Salvianolate causes drug-induced autoimmune hemolytic anemia in this patient.


Assuntos
Anemia Hemolítica Autoimune , Transfusão de Sangue , Eritrócitos , Humanos , Extratos Vegetais , Estudos Retrospectivos
10.
J Clin Apher ; 35(3): 206-216, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32240559

RESUMO

INTRODUCTION: Neuromyelitis optica (NMO) is an autoimmune disease with a high rate of blindness and positive for the detection of aquaporin-4 antibody (AQP4) in most patients. NMO acute attacks are managed by high-doses of intravenous methylprednisolone followed by oral taper, and if symptoms fail to resolve, therapeutic plasma exchange (TPE) is added. TPE can remove pathological antibodies and inflammatory factors leading to clinical improvement. METHODS: A total of 40 TPE fluid collections from the first to fifth TPE treatments were obtained from eight patients. Exosomes were isolated by ultracentrifugation. Mass spectrometry analyses were used to compare protein change in TPE fluid collection exosomes after the first to the fifth TPE treatments in these patients. RESULTS: We detected 647 exosome proteins through data-independent acquisition analysis. It was found that some unknown functional antibody fragments and complement pathway proteins decreased after TPE treatment. The results revealed a significant involvement of the following two key pathways: the primary immunodeficiency and systemic lupus erythematosus that may be associated with NMO pathophysiology and TPE treatment efficacy (P < .05). A series of complement proteins may contribute to NMO; in addition, the following proteins increased with plasma exchange: complement factor H-related protein 5, bridging integrator 2, neuroplastin, pigment epithelium-derived factor, ficolin-1, extracellular matrix protein 1, and fatty acid-binding protein 5. CONCLUSION: Our study may provide a new perspective on the pathogenesis and treatment efficacy of NMO.


Assuntos
Aquaporina 4/imunologia , Exossomos/patologia , Neuromielite Óptica/imunologia , Neuromielite Óptica/terapia , Troca Plasmática/efeitos adversos , Adulto , Autoanticorpos/imunologia , Biologia Computacional , Feminino , Humanos , Imunoglobulina G/imunologia , Lúpus Eritematoso Sistêmico/imunologia , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Plasmaferese/efeitos adversos , Doenças da Imunodeficiência Primária/imunologia , Ultracentrifugação
11.
Front Genet ; 10: 777, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31543901

RESUMO

Long noncoding RNAs (lncRNAs) are involved in various biological regulatory processes, but their roles in plants resistance to salt stress remain largely unknown. To systematically explore the characteristics of lncRNAs and their roles in plant salt responses, we conducted strand-specific RNA-sequencing of four tissue types with salt treatments in two closely related poplars (Populus euphratica and Populus alba var. pyramidalis), and a total of 10,646 and 10,531 lncRNAs were identified, respectively. These lncRNAs showed significantly lower values in terms of length, expression, and expression correction than with mRNA. We further found that about 40% and 60% of these identified lncRNAs responded to salt stress with tissue-specific expression patterns across the two poplars. Furthermore, lncRNAs showed weak evolutionary conservation in sequences and exhibited diverse regulatory styles; in particular, tissue- and species-specific responses to salt stress varied greatly in two poplars, for example, 322 lncRNAs were found highly expressed in P. euphratica but not in P. alba var. pyramidalis and 3,425 lncRNAs were identified to be species-specific in P. euphratica in response to salt stress. Moreover, tissue-specific expression of lncRNAs in two poplars were identified with predicted target genes included Aux/IAA, NAC, MYB, involved in regulating plant growth and the plant stress response. Taken together, the systematic analysis of lncRNAs between sister species enhances our understanding of the characteristics of lncRNAs and their roles in plant growth and salt response.

12.
Clin Chim Acta ; 498: 68-75, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31421121

RESUMO

BACKGROUND: Platelet antibodies can lead to clinical diseases such as platelet transfusion refractoriness (PTR), fetal/neonatal alloimmune thrombocytopenia (FNAIT), etc. This study is aimed at understanding CD36 expression, platelet alloantibody distribution in different populations in Northern China, and effects of platelet alloantibodies on pregnancy. STUDY DESIGN AND METHODS: Whole blood samples of 612 subjects including hematological patients, pregnant women, and blood donors were collected at a single center, then CD36 expressions were determined, followed by platelet antibody screening and characterization of platelet antibody specificity. A retrospective analysis was performed in 1552 pregnant women admitted to Department of Obstetrics, in order to investigate FNAIT occurrence. RESULTS: Rate of CD36 deficiency expression was 2.12% (13/612), all cases exhibited type II deficiency without type I deficiency being detected, and such rate is lower than that in Southern China (3.43%), Japanese (4.87%) and in the black people (4.18%), and higher than that in the White people (0.09%). Positive rates of platelet antibody screening in hematological patient group (6.86%, 14/204) and in pregnant women group (6.31%, 13/206) are higher than that in blood donor group (0.49%, 1/202), P < .01. Out of 1552 pregnant women, there were not children with FNAIT. CONCLUSION: The frequency of CD36 deficiency in northern China was low, all of them were type II deficiency, and no CD36 antibody was detected. It is speculated that the risk of immune-related thrombocytopenia caused by CD36 deficiency in this population is very low. Platelet antibodies should be monitored early in patients with hematological and multiple miscarriages pregnant.


Assuntos
Plaquetas/imunologia , Antígenos CD36/deficiência , Isoanticorpos/farmacologia , Doadores de Sangue , China/epidemiologia , Feminino , Doenças Hematológicas/imunologia , Humanos , Isoanticorpos/metabolismo , Masculino , Gravidez , Complicações na Gravidez/imunologia , Púrpura Trombocitopênica Idiopática/etiologia , Púrpura Trombocitopênica Idiopática/imunologia , Estudos Retrospectivos , Trombocitopenia Neonatal Aloimune/etiologia , Trombocitopenia Neonatal Aloimune/imunologia
13.
Bioresour Technol ; 222: 14-23, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27697733

RESUMO

Fruit and vegetable waste (FVW) is become a serious problem in developing countries. Enzymolysis is a potentially useful method for the treatment of FVW. In the present study, novel recycled magnetic molecular imprinting immobilised cellulases were prepared based on magnetic modified chitosan (MCTS) and Fe3O4. The properties of obtained were characterised by IR and grain-size measurements. Evaluation of a single factor affecting the loading efficiency of supports and the mixed immobilised enzymes showed better capacity than single immobilised, or free, enzymes. The immobilisation process could improve cellulase stability and repeatability of the method. Meanwhile, the kinetic parameters were also verified. The immobilised enzymes retained most of their capacity after 60days' storage while free enzymes lost it within 30days. Tests showed that the immobilised enzymes developed excellent capacity and five anthocyanins were collected.


Assuntos
Antocianinas/isolamento & purificação , Celulases/metabolismo , Enzimas Imobilizadas/metabolismo , Frutas/química , Magnetismo/métodos , Impressão Molecular/métodos , Nanopartículas/química , Verduras/química , Glucose/análise , Concentração de Íons de Hidrogênio , Cinética , Reciclagem , Temperatura , Fatores de Tempo , Resíduos
14.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 23(5): 1478-82, 2015 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-26524061

RESUMO

OBJECTIVE: To evaluate the effects of the 25 Gy 6°Co irradiation on the physiological and biochemical properties and the functions of the platelets during storage. METHODS: A total of 15 bags of platelets were apheresis-collected from 15 healthy donors, and each bag of platelets were divided into 2 parts, then the platelets were divided into the control group (without 25 Gy 6°Co irradiation) and the irradiated group (with 25 Gy 6°Co irradiation) groups. The two groups of platelets were kept under the condition of (22 ± 2) °C and shaken. The Platelet count and pH value were detected on the d 1, d 2, d 3, d 4 and d 5. The variables such as R, K values, α angle and maximal amplitude (MA) were measured by thrombelastography on the same days. Hypotonic shock response (HSR), morphological score were devised. RESULTS: There were no statistically significant difference in Plt counts, mean platelet volume (MPV), platelet distribute width (PDW) and pH between the two groups (P > 0.05), and Plt count decreased on the end of storage. There were no marked changes in HSR level and morphological score between the two groups during storage, and there were no significant difference between the two groups (P > 0.05). In the TEG analysis there were no significant difference of the R, K, α angle and MA values between the two groups (P > 0.05). R value showed upward trend increased along with prolongation of preserved time (P < 0.01), no significant changes in α angle (P > 0.05), K value was slightly higher and MA value was lower in the last day of storage than the days 1-4 (P < 0.01), respectively. CONCLUSION: 25 Gy 6°Co gamma-ray irradiation can not damage the physiological, biochemical properties and the functions of the platelets during storage. In order to ensure the best curative effect, it is suggested that no matter the platelets were irradiated or not, the platelets should be used as soon as possible.


Assuntos
Plaquetas/efeitos da radiação , Preservação de Sangue , Raios gama , Humanos , Contagem de Plaquetas
15.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 23(4): 1081-6, 2015 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-26314450

RESUMO

OBJECTIVE: To investigate the factors influencing platelet transfusion results so as to improve the platelet transfusion efficiency. METHODS: According to the clinical symptoms (bleeding condition is stopped or improved)and the corrected count of increment (CCI), the patients were divided into efficient transfusion and inefficient transfusion groups. A total of 20 671 patients' clinical data and main platelet transfusion parameters in 26 045 tranfusions including platelet count of per- and post- transfusion, platelet component sorts, storage time and transfusion number were analysed. RESULTS: The comparison of platelet transfusion efficiency in age and sex between two groups did not showed statistical difference (P > 0.05), the platelet count before transfusion between two groups showed statistical difference (t = -5.59, P < 0.001) after converting to log, a significant linear correlation did not exist between storage time of the platelet and CCI (corrected count of increment), but there was statistical difference in transfusion efficiency of patients with different diseases. The patients with hematologic diseases showed lower efficiency of platelet transfusion. According to the results of Wilcocon test detection, there was difference between different times of transfusion and transfusion efficiency, that is to say, the transfusion frequency was higher, the transfusion efficency was lower. The Fisher test indicated that the transfusion efficiency of single platelet transfusion was lower than that of transfussed platelet with other blood components (P < 0.01). CONCLUSION: Platelet transfusion efficiency associates with many factors, including different diseases, whether being transfused with other blood components, the platelet count before transfusion, transfusion frequency, but the time of storage does not relate to the transfusion efficacy.


Assuntos
Transfusão de Plaquetas , Plaquetas , Doenças Hematológicas , Humanos , Contagem de Plaquetas
16.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 21(5): 1275-9, 2013 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-24156449

RESUMO

This study was aimed to analyze the serological characteristics, efficacy and safety of incompatible RBC transfusion in patients with autoimmune hemolytic anemia (AIHA). The patients with idiopathic or secondary AIHA were analyzed retrospectively, then the serological characteristics and the incidence of adverse transfusion reactions were investigated, and the efficacy and safety of incompatible RBC transfusion were evaluated according to the different autoantibody type and infused different RBC components. The results showed that out of 61 cases of AIHA, 21 cases were idiopathic, and 40 cases were secondary. 8 cases (13.1%) had IgM cold autoantibody, 50 cases (82.0%) had IgG warm autoantibody, and 3 cases (4.9%) had IgM and IgG autoantibodies simultaneously. There were 18 cases (29.5%) combined with alloantibodies. After the exclusion of alloantibodies interference, 113 incompatible RBC transfusions were performed for 36 patients with AIHA, total efficiency rate, total partial efficiency rate and total inefficiency rate were 56.6%, 15.1% and 28.3%, respectively. Incompatible RBC transfusions were divided into non-washed RBC group and washed RBC group. The efficiency rate, partial efficiency rate and inefficiency rate in non-washed RBC group were 57.6%, 13.0% and 29.4%, respectively. The efficiency rate, partial efficiency rate and inefficiency rate in washed RBC group were 53.6%, 21.4% and 25.0%, respectively. There was no significant difference of transfusion efficacy (P > 0.05) in two groups. Incompatible RBC transfusions were also divided into IgM cold autoantibody group and IgG warm autoantibody group. The efficiency rate, partial efficiency rate and inefficiency rate in IgM cold autoantibody group were 46.2%, 30.8% and 29.4%, respectively. The efficiency rate, partial efficiency rate and inefficiency rate in IgG warm autoantibody group were 56.7%, 13.4% and 29.9%, respectively. There was no significant difference of transfusion efficacy (P > 0.05 ) in two groups. Hemolytic transfusion reaction was not observed in all incompatible RBC transfusions. It is concluded that the same ABO type of non-washed RBC transfusion and O type washed RBC transfusion are all relatively safe for the AIHA patients with severe anemia after the exclusion of alloantibodies interference. There is no significant difference of transfusion efficacy in two groups. The same ABO type of non-washed RBC transfusion is more convenient and efficient than washed RBC transfusion, and excessive use of type O RBCs can also be avoided.


Assuntos
Anemia Hemolítica Autoimune/imunologia , Anemia Hemolítica Autoimune/terapia , Transfusão de Eritrócitos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anemia Hemolítica Autoimune/diagnóstico , Tipagem e Reações Cruzadas Sanguíneas , Feminino , Humanos , Isoanticorpos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...