Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Fr Ophtalmol ; 45(3): 331-337, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35063295

RESUMO

PURPOSE: To explore the national trend in prescriptions for glaucoma and ocular hypertension (OHT) in France between 2014 and 2019. METHODS: This is a retrospective descriptive study based on prescription data from the Primary Health Insurance Fund databases. All patients with a social security number who received one or more glaucoma/OHT prescriptions between 2014 and 2019 were identified. Figures for 2020 are not yet available as of the date of submission of this article. Demographic characteristics from Common Classification of Medical Acts information and from National Institute of Statistics and Economic Studies were analyzed. The data analysis was carried out using the R version 3.6.2.software from the available databases of the Information Systems Medicalization Program. RESULTS: Our results suggest an increase in the number of patients treated with glaucoma drugs, which cannot be explained simply by demographic growth. There is also a change in drug prescription habits, both in the class of medication used and in the use of fixed combinations. We also note the increasing use of SLT (Selective Laser Trabeculoplasty), a relatively newer tool in the therapeutic arsenal. Over the same time period, demographic characteristics remained stable; age and sex distribution for each year remained constant. In addition, the phenomenon of poor therapeutic compliance, which we attempted to explore, remained stable. DISCUSSION: This study updates the French epidemiologic data available on prescriptions for glaucoma and ocular hypertension, a true public health concern. CONCLUSION: On the one hand, prescribing practices have evolved over the study period. On the other hand, the number of patients treated has increased faster than the growth of the French population over the same period. These findings are consistent with trends observed in previous studies.


Assuntos
Glaucoma , Terapia a Laser , Hipertensão Ocular , Trabeculectomia , Anti-Hipertensivos/uso terapêutico , Glaucoma/tratamento farmacológico , Glaucoma/epidemiologia , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Terapia a Laser/métodos , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/epidemiologia , Prescrições , Estudos Retrospectivos , Trabeculectomia/métodos
3.
J Fr Ophtalmol ; 43(7): 642-652, 2020 Sep.
Artigo em Francês | MEDLINE | ID: mdl-32631687

RESUMO

The COVID-19 pandemic has dramatically changed our daily lives as ophthalmologists. This general review firstly provides a better understanding of the virus responsible for the pandemic: the SARS-CoV-2, and the clinical manifestations of the COVID-19 disease. The second part is detailing the pathophysiology, clinical signs and challenges of ocular involvement, which seems rare and not functionally severe, but which may be a potential source of contamination. Finally, we discuss the preventive measures that need to be implemented in our daily practice to avoid any viral dissemination.


Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Infecções Oculares Virais/virologia , Pneumonia Viral/complicações , Betacoronavirus/genética , Betacoronavirus/ultraestrutura , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/prevenção & controle , Técnicas de Diagnóstico Oftalmológico , Olho/virologia , Infecções Oculares Virais/fisiopatologia , Infecções Oculares Virais/prevenção & controle , Genoma Viral , Humanos , Microscopia Eletrônica , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/fisiopatologia , Pneumonia Viral/prevenção & controle , SARS-CoV-2 , Integração Viral
6.
J Fr Ophtalmol ; 42(5): 499-516, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30955899

RESUMO

Spectral domain optical coherence tomography (SD-OCT) provides an objective quantification of the lesions of various target tissue structures in glaucoma, with unprecedented resolution, which has now demonstrated its interest in controlling the progression of glaucomatous neuropathy, from early stages to late stages. A certain number of well-established proofs state that a progressive modification in OCT is a common predictor of functional loss, and that patients with rapid OCT changes have an increased risk of developing glaucomatous scotoma. Follow-up of the progression goes through three stages. It consists first of all in detecting the evolution of damage to the retinal nerve fiber layer (RNFL), then that of the macular ganglion cell complex (GCC), in order to better define this progression of the damage to the target structures and, thirdly, to complete its analysis by integrating it with the analysis of the functional impairment. We note today that there is a greater risk of developing a future functional deficit of the visual field in subjects with a RNFL loss slope greater than -1/year, for all clinical stages of glaucoma. The characteristics of GCC progression are much better specified. Often earlier than that of the progress of the thinning of the RNFL and much faster in the subjects considered as "progressors", its cartography is better defined, with a particular interest for the follow-up of diversion maps and "wide field" acquisitions offering better visibility of deficits and their progression. To date, a certain number of suspicious indicators of short-term progress can be retained, highlighting the essential precaution of having two or more basic measures and a confirmation of the change on at least one new OCT acquisition. Finally, if the interpretation of the progression must always be based on clinical examination data, and the macula in particular, it remains crucial to confront the progression of the RNFL with that of the GCC and with that of the visual field.


Assuntos
Glaucoma/diagnóstico , Glaucoma/patologia , Tomografia de Coerência Óptica/métodos , Envelhecimento/patologia , Envelhecimento/fisiologia , Progressão da Doença , Humanos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Fibras Nervosas/patologia , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Fatores de Tempo , Campos Visuais
7.
J Fr Ophtalmol ; 40(10): 865-875, 2017 Dec.
Artigo em Francês | MEDLINE | ID: mdl-29174296

RESUMO

PURPOSE: The Icare® Home tonometer is a new rebound tonometer, developed for intraocular pressure (IOP) self-monitoring. The main objective of our study was to evaluate the reliability and reproducibility of measurements taken with the Icare® Home tonometer in glaucoma patients compared to the Goldmann applanation tonometer. A secondary objective was to investigate factors that could influence the reproducibility of these measurements. MATERIALS AND METHODS: Fifty-two glaucoma patients were included in this prospective, non-randomized, monocentric study. IOP measurements were performed on the right eye and then on the left eye in the following order (3 measurements of IOP for each method): air tonometer (T-Air), Icare® Home tonometer by the patient (RT-P), Icare® Home tonometer by an ophthalmologist (RT-O), Goldmann applanation tonometer (GAT). RESULTS: Forty-four patients (85%) managed to take their IOP on both eyes with the Icare® Home tonometer. Mean IOPs were 14.35±3.93mmHg (T-Air), 13.43±4.65mmHg (RT-P), 14.13±4.29mmHg (RT-O), 14.74±3.84mmHg (GAT). The intraclass correlation indices (ICC) on the 3 repeated IOP measurements were 0.924, 0.872, 0.947 and 0.957, respectively. Bland-Altman analysis found a mean difference (bias) between GAT and RT-P, between GAT and RT-O, and between RT-O and RT-P, respectively, of 1.31, 0.61 and 0.70mmHg, with a 95% confidence interval of -3.34 to 5.96, -3.91 to 5.14 and -3.44 to 4.84mmHg, respectively. The reproducibility of the measurements taken with the Icare® Home tonometer did not vary according to corneal thickness or age of the patients. CONCLUSION: The Icare® Home tonometer provides reliable and reproducible IOP values in glaucoma patients, although it appears to slightly underestimate the IOP measurements compared to the Goldmann applanation tonometer.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular , Hipertensão Ocular/diagnóstico , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos , Idoso , Autoavaliação Diagnóstica , Feminino , Glaucoma/fisiopatologia , Serviços de Assistência Domiciliar , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Reprodutibilidade dos Testes , Autocuidado , Sensibilidade e Especificidade
8.
J Fr Ophtalmol ; 40(1): 22-28, 2017 Jan.
Artigo em Francês | MEDLINE | ID: mdl-28081918

RESUMO

PURPOSE: To evaluate the lowering of intraocular pressure (IOP) one year after SLT and to assess if differences are related to number of pre-SLT topical treatments in ocular hypertension (OHT) and primary open angle glaucoma (POAG) patients. METHODS: Retrospective review of 106 eyes of 13 OHT and 93 POAG patients treated by SLT for insufficient IOP control, allergy, discomfort or non-compliance to glaucoma medications, excluding patients with less than 1 year of follow-up after SLT. IOP was measured by applanation before and at 1, 6 and 12 months after SLT. RESULTS: Hundred and six eyes untreated (n=13), or treated with one (n=25), two (n=40) or three or more (n=28) glaucoma medications were included. Mean IOP decreased from 19.4±3.6mmHg preoperatively to 15.7±3.1mmHg at 12 months, which corresponds to an average decrease of 18.8%. At 1 year, 62.2% (n=66) were responders (IOP reduction≥3mmHg): 92.3% without medications (n=12), 68% with one (n=17), 57.5% with two (n=23) and 50% with three or more medications (n=14). Their average IOP decreased from 20.7±3.4 to 15.2±2.9mmHg (26.6%), respectively from 20.8±2.6 to 15.8±3.2 (25%) without medications, 20.6±3.2 to 14.9±3.7 (27.3%) with one, 20.8±4.1 to 15.5±3.3 (25.1%) with two and 20.7±3.2 to 14.4±2.4mmHg (29.7%) with three medications. CONCLUSIONS: The number of responders seems to be greater in OHT and POAG patients without or with few glaucoma medications, but the IOP reduction seems to be similar regardless of the number of glaucoma medications.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/efeitos dos fármacos , Terapia a Laser/métodos , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/cirurgia , Trabeculectomia/métodos , Administração Tópica , Terapia Combinada , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Hipertensão Ocular/fisiopatologia , Cuidados Pré-Operatórios/métodos , Período Pré-Operatório , Estudos Retrospectivos , Resultado do Tratamento
9.
J Fr Ophtalmol ; 38(9): 832-43, 2015 Nov.
Artigo em Francês | MEDLINE | ID: mdl-26494495

RESUMO

PURPOSE: To evaluate intra- and interobserver reproducibility of macular GCC thickness measurement by automated segmentation on the Canon HS-100 SD-OCT (Tokyo, Japan) in normal (N), hypertensive (OHT) and glaucomatous eyes. METHODS: A total of 179 eyes of 93 patients were included: 90 N, 28 OHT and 36 early glaucoma and 25 advanced glaucoma. All patients underwent a complete ophthalmologic exam, central corneal thickness and 24-2 standard automated perimetry (HFA SITA standard). Each of two observers performed three macular acquisitions with the Canon OCT HS-100. Acquisitions were analyzed with the Glaucoma 3D mode, which estimated the macular GCC thickness in global, superior and inferior hemisectors, and in eight separate macular areas. Reproducibility was assessed by intraclass correlation coefficient (ICC), coefficient of variation (CV) and test-retest variability (TRTV) calculated as 1.96 times the standard deviation. RESULTS: Mean GCC thickness was respectively 92.4 µm, 89.0 µm, 80.7 µm and 71.2 µm in N, OHT, early and advanced glaucomatous eyes. In all groups, intra- and interobserver reproducibility ranged respectively for ICC from 89.8 to 99.8% and from 90.2 to 99.4%, for CV from 0.43 to 1.95% and from 0.58 to 2.16% and for TRTV from 0.8 to 3.22 µm and from 1.04 to 3.53 µm. GCC thickness measurements using the new HS-100 SD-OCT were highly reproducible. However, in the advanced glaucoma group, while the reproducibility of GCC thickness measurement is good in the average, superior and inferior hemisectors of the macula, it was slightly less for the paracentral sectors, especially inferior. These sectors correspond generally to the areas most affected by glaucoma. CONCLUSION: The reproducibility of GCC thickness measurements using the new Canon HS-100 SD-OCT is high for normal, OHT, and glaucomatous eyes. It is thus a reliable and reproducible ancillary test available to the clinician for the examination of glaucomatous optic neuropathies.


Assuntos
Hipertensão Ocular/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Desenho de Equipamento , Glaucoma/patologia , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Células Ganglionares da Retina/citologia , Tomografia de Coerência Óptica/instrumentação
11.
J Fr Ophtalmol ; 38(1): 46-52, 2015 Jan.
Artigo em Francês | MEDLINE | ID: mdl-25575418

RESUMO

INTRODUCTION: Clinical determination of the outer limits of the optic disk (OD) doesn't always correspond to the true anatomic limits of the optic nerve head (ONH) defined by the Bruch's membrane opening (BMO). A new index analyzing the OD with optical coherence tomography (OCT), "minimal rim width" (BMO-MRW), evaluates the smallest thickness of the neuroretinal rim between the BMO and the internal limiting membrane. The purpose of this study was to evaluate new software for automatic measurement of the BMO-MRW. MATERIALS AND METHODS: This study investigated 95 eyes: 40 control eyes and 55 eyes followed and treated for primary open angle glaucoma (42 early glaucoma, 7 moderate glaucoma and 6 advanced glaucoma). After a precise localization of the OD center, 24 radial scans of the ONH are taken with the Spectralis OCT (Heidelberg Engineering, Germany). From the 48 measurements of BMO-MRW, the mean thickness as well as that in each of the 6 papillary sectors of this new index are calculated. ROC curves analysis (receiver operating characteristic) was used to assess the diagnostic capabilities of the various parameters. RESULTS: Thicknesses of all parameters were statistically lower in glaucoma than in controls. The mean value and inferotemporal sector (IT) had the best diagnostic capabilities without significant difference between them (BMO-MRW-average = 0.890 ± 0.062, BMO-MRW-IT = 0.881 ± 0.066, P = 0.59). The area under the curve was lowest in the temporal sector (0.820 ± 086 statistically lower than the average value, P = 0.04). CONCLUSIONS: This preliminary study of a new automated analysis of the neuroretinal rim highlights the diagnostic value of the BMO-MRW index. This evaluation appears to be best correlated with the anatomy of the ONH with good diagnostic sensitivity.


Assuntos
Antropometria/métodos , Lâmina Basilar da Corioide/ultraestrutura , Disco Óptico/ultraestrutura , Tomografia de Coerência Óptica/métodos , Idoso , Algoritmos , Antropometria/instrumentação , Área Sob a Curva , Feminino , Glaucoma de Ângulo Aberto/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Software , Tomografia de Coerência Óptica/instrumentação
14.
J Fr Ophtalmol ; 37(9): 682-8, 2014 Nov.
Artigo em Francês | MEDLINE | ID: mdl-25262053

RESUMO

PURPOSE: To evaluate efficacy and patient satisfaction of presbyopic hyperopes treated with centered PresbyLASIK (multifocality centered on near vision) by the SUPRACOR technique (Technolas Perfect Vision). MATERIALS AND METHODS: This is a retrospective study carried out at Percy Army Teaching Hospital from September 2011 through September 2013. Fifty-nine eyes of 29 patients were included and underwent PresbyLASIK. Study parameters included uncorrected binocular distance (DVA) and near (NVA) visual acuity, aberrometry, central corneal curvature by corneal topography (bump), and patient satisfaction (questionnaire). RESULTS: Mean uncorrected binocular visual acuity was found to be 0.09 logmar for DVA and 0.22 for NVA on post-operative day one, 0.04 logmar for DVA and 0.17 for NVA at 1 month post-operatively, 0.15 logmar for DVA and 0.19 for NVA at 3 months post-operatively, and -0.02 logmar for DVA and 0.18 for NVA at 6 months post-operatively. Mean central corneal curvature was found to be 2.56±0.9 diopters. There were significantly more higher-order aberrations in the central 5mm post-operatively (P<0.01). Among the patients undergoing bilateral SUPRACOR LASIK, 79% were entirely satisfied with the surgery, and all patients would recommend the procedure to their family and friends. Eighty-six percent of these patients acheived total spectacle independence at distance and near. CONCLUSION: SUPRACOR PresbyLASIK is a method of choice in overcoming spectacle dependence in presbyopic hyperopes.


Assuntos
Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Presbiopia/cirurgia , Aberrometria , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Retrospectivos , Visão Binocular , Acuidade Visual
15.
J Fr Ophtalmol ; 36(4): 378-83, 2013 Apr.
Artigo em Francês | MEDLINE | ID: mdl-23541534

RESUMO

Iridocorneal angle assessment is essential in glaucoma diagnosis and management, and gonioscopy remains the clinical reference standard for its evaluation. However, performance and interpretation of gonioscopy requires experience and has several limitations. Ultrasound biomicroscopy (UBM) and more recently anterior segment OCT (AS-OCT) and Scheimpflug camera have contributed to a better understanding of the mechanisms of angle-closure, screening of patients at risk for angle-closure glaucoma, and understanding of angle structures in secondary open angle glaucomas. Rapid and non-contact, AS-OCT has made this analysis easier than with UBM, but it is limited by its weak penetration through iris and scleral tissues.


Assuntos
Córnea/patologia , Diagnóstico por Imagem/métodos , Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ângulo Fechado/diagnóstico , Gonioscopia/métodos , Iris/patologia , Córnea/diagnóstico por imagem , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Glaucoma de Ângulo Fechado/patologia , Glaucoma de Ângulo Fechado/terapia , Humanos , Iris/diagnóstico por imagem , Microscopia Acústica/métodos , Radiografia , Tomografia de Coerência Óptica/métodos
16.
J Fr Ophtalmol ; 36(4): 299-309, 2013 Apr.
Artigo em Francês | MEDLINE | ID: mdl-23541535

RESUMO

Early detection of ganglion cell loss is possible with new algorithms for the assessment of the Macular Ganglion Cell Complex (GCC) by SD-OCT. The various data acquisition protocols used by the various versions of software, as well as their accuracy and reproducibility, must be taken into account. Current results show similar ability to detect glaucoma as compared to Retinal Nerve Fiber Layer thickness (RNFL), with some limitations, possible artifacts, and interpretation pitfalls which must be taken into account. The role of the significance map and of various indices (Focal Loss Volume, Global Loss Volume, GCIPL minimum...); data obtained in the setting of various clinical entities (tilted disc, peripapillary atrophy, large and small optic discs, high myopia...); and detection of progression, especially in advanced glaucoma, underline the role of macular GCC analysis as a complementary method to peripapillary RNFL thickness. The diagnostic precision and better reproducibility of these new software protocols offer new perspectives in the detection and management of progression in various stages of the management of glaucomatous optic neuropathy.


Assuntos
Glaucoma/patologia , Macula Lutea/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Progressão da Doença , Angiofluoresceinografia , Glaucoma/complicações , Humanos , Miopia/complicações , Miopia/patologia , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/métodos
17.
J Fr Ophtalmol ; 35(6): 426-31, 2012 Jun.
Artigo em Francês | MEDLINE | ID: mdl-22475537

RESUMO

INTRODUCTION: Retinal vein occlusions are the second leading cause of retinal vascular disease, after diabetic retinopathy. In the case of young subjects, a thorough etiological investigation must be conducted in order to diagnose rare etiologies, such as this heterozygous mutation of the factor II gene associated with a central retinal vein occlusion (CRVO), occurring in a young subject within the context of trauma. OBSERVATION: The case deals with a 35-year-old soldier on a mission in a conflict zone. He was the victim of blast injury as a result of the explosion of an improvised explosive device (IED) or homemade bomb, and presented a sudden decline in visual acuity in his left eye associated with the clinical picture of a CRVO. Analysis showed a heterozygous factor II G20210A gene mutation. CONCLUSION: Retinal vein occlusions are always serious visual events. In the case of young subjects, a thorough etiological investigation must be conducted in search of rare abnormalities likely to lead to retinal vein occlusion.


Assuntos
Traumatismos Craniocerebrais/complicações , Oclusão da Artéria Retiniana/diagnóstico , Oclusão da Artéria Retiniana/etiologia , Adulto , Idade de Início , Bombas (Dispositivos Explosivos) , Traumatismos Craniocerebrais/diagnóstico , Substâncias Explosivas/efeitos adversos , Humanos , Masculino , Militares , Oclusão da Artéria Retiniana/epidemiologia
18.
J Fr Ophtalmol ; 34(5): 313-7, 2011 May.
Artigo em Francês | MEDLINE | ID: mdl-21536340

RESUMO

INTRODUCTION: Choroidal thickness (CT) can be evaluated with spectral domain OCT. The authors report the results from a preliminary study comparing CT in normal and glaucomatous eyes. PATIENTS AND METHOD: The aim of this study was to measure subfoveolar CT in normal and glaucomatous eyes and to evaluate the recent enhanced depth imaging technique (EDI SD-OCT). Seventeen eyes of nine healthy subjects where compared with 23 eyes of 14 glaucomatous patients. CT was evaluated using a Spectralis™ OCT. A section was obtained within a 30° scan centered on the fovea, with 100 scans averaged for each section. Two acquisitions were made for each eye by the same operator to obtain an average CT measurement. The results were compared with clinical examination data (refractive error, peripapillary atrophy, and age). RESULTS: There was a strong correlation between the two measurements r=0.99 (p<0.001). The mean age of the healthy group was 72.76±7.71 years, the mean refractive error was 0.71±0.74 D, and peripapillary atrophy was present in 29% of the eyes. The mean subfoveal CT was 224.38µm. The mean age of the glaucomatous group was 71.39±11.37, the mean refractive error was-1.37±2.74 D, and peripapillary atrophy was present in 70% of the eyes. The mean subfoveal CT was 219.98µm. There was no significant difference between the two populations for the subfoveolar CT or refractive errors. In both groups, there was a negative correlation between CT and peripapillary atrophy. In healthy eyes, peripapillary atrophy was correlated with age (p<0.001), whereas it was not in the glaucomatous population (p=0.795). DISCUSSION: This is the first study, to our knowledge, evaluating EDI OCT in glaucomatous eyes. Reproducibility was excellent. There was always a negative correlation between CT and peripapillary atrophy. There was no CT difference between the normal and glaucomatous group, but the number of patients was small. CONCLUSION: Further studies are required to evaluate the possible relationship between CT and peripapillary atrophy and the link with the evolutive stage of the glaucomatous neuropathy.


Assuntos
Antropometria/métodos , Corioide/patologia , Glaucoma de Ângulo Aberto/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Atrofia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Projetos Piloto , Erros de Refração/diagnóstico , Reprodutibilidade dos Testes
19.
J Fr Ophtalmol ; 33(4): 291-5, 2010 Apr.
Artigo em Francês | MEDLINE | ID: mdl-20304520

RESUMO

Adherence to glaucoma therapy is a major factor of therapeutic efficacy. It reflects the patient's perception of the glaucoma disease and its treatment. Evaluation of adherence, often underestimated, is simple with a four-step strategy underscoring the importance of informing and educating the patient. The quality of the physician-patient relationship is essential for a good adapted assessment with every patient and at all stages of the disease so as to enhance adherence to glaucoma treatment and help patients.


Assuntos
Glaucoma/tratamento farmacológico , Cooperação do Paciente , Atitude Frente a Saúde , Glaucoma/prevenção & controle , Humanos , Adesão à Medicação , Motivação , Destreza Motora , Educação de Pacientes como Assunto , Relações Médico-Paciente , Meio Social , Resultado do Tratamento
20.
J Fr Ophtalmol ; 33(1): 2-9, 2010 Jan.
Artigo em Francês | MEDLINE | ID: mdl-20005005

RESUMO

OBJECTIVE: The Visual Field Index -VFI- is a new perimetric index allowing evaluation of visual function level and progression. In this study, we analysed this new index, that provides a trend analysis of visual field loss progression in Ocular Hypertension and Glaucoma. We also compared results with event analysis. METHODS: Retrospective study on 94 eyes of 54 patients: 35 OHT(ocular hypertension), 34 early POAG (primary open angle glaucoma) (0>MD>-6 dB), 13 moderate POAG (-6>MD>-12 dB) and 12 advanced POAG (MD<-12 dB), with a mean follow-up of 6.5 years (4 to 8 years). Each subject performed a mean number of 10 standard automated perimetry visual field tests (Humphrey SITA Standard 24-2), excluding tests without reliable indices. VFI progression rate was analysed. VFI progression during the first half period of follow up was compared with that during the second half period. VFI progression was confronted with script alert messages delivered by the last GPA (Guided Progression Analysis) event analysis program. RESULTS: VFI values were "stable or with low progression" in 100% of OHT patients, 88% of early POAG, 38.5% of moderate POAG, 33% of advanced POAG. Progression during the first half period (mean of 3 years) of follow-up could be extrapolated for the second half period in 97% of OHT patients, 76% of early POAG, 70% of moderate POAG, 75% of advanced POAG. Results from VFI trend analysis and GPA event analysis corresponded in 97% of OHT patients, 85% of early POAG, 85% of moderate POAG, and 87% of advanced POAG. DISCUSSION: VFI seems to be a useful indicator for glaucoma evaluation and progression follow-up. It completes the event analysis. Some very advanced POAG cannot be analysed by GPA event analysis. VFI should be able to be used for further follow-up. All these results require validation in larger population. The purpose would be to assess if VFI is able to detect different profiles of progression to help treatment decisions.


Assuntos
Glaucoma/fisiopatologia , Campos Visuais , Técnicas de Diagnóstico Oftalmológico , Progressão da Doença , Humanos , Hipertensão Ocular/fisiopatologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...