Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Occup Environ Hyg ; 19(8): 455-468, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35687041

RESUMO

The list of EPA-approved disinfectants for coronavirus features many products for use on hard, non-porous materials. There are significantly fewer products registered for use on porous materials. Further, many common, high-touch surfaces fall in between non-porous materials such as glass and porous materials such as soft fabrics. The objective of this study was to assess the efficacy of selected commercially available disinfectant products against coronaviruses on common, high-touch surfaces. Four disinfectants (Clorox Total 360, Bleach solution, Vital Oxide, and Peroxide Multi-Surface Cleaner) were evaluated against Murine Hepatitis Virus A59 (MHV) as a surrogate coronavirus for SARS-CoV-2. MHV in cell culture medium was inoculated onto four materials: stainless steel, latex-painted drywall tape, Styrene Butadiene rubber (rubber), and bus seat fabric. Immediately (T0) or 2-hr (T2) post-inoculation, disinfectants were applied by trigger-pull or electrostatic sprayer and either held for recommended contact times (Spray only) or immediately wiped (Spray and Wipe). Recovered infectious MHV was quantified by median tissue culture infectious dose assay. Bleach solution, Clorox Total 360, and Vital Oxide were all effective (>3-log10 reduction or complete kill of infectious virus) with both the Spray Only and Spray and Wipe methods on stainless steel, rubber, and painted drywall tape when used at recommended contact times at both T0 and T2 hr. Multi-Surface Cleaner unexpectedly showed limited efficacy against MHV on stainless steel within the recommended contact time; however, it showed increased (2.3 times greater efficacy) when used in the Spray and Wipe method compared to Spray Only. The only products to achieve a 3-log10 reduction on fabric were Vital Oxide and Clorox Total 360; however, the efficacy of Vital Oxide against MHV on fabric was reduced to below 3-log10 when applied by an electrostatic sprayer compared to a trigger-pull sprayer. This study highlights the importance of considering the material, product, and application method when developing a disinfection strategy for coronaviruses on high-touch surfaces.


Assuntos
COVID-19 , Desinfetantes , Vírus da Hepatite Murina , Animais , Desinfetantes/farmacologia , Desinfecção/métodos , Camundongos , Borracha/farmacologia , SARS-CoV-2 , Hipoclorito de Sódio/farmacologia , Aço Inoxidável/farmacologia
2.
Phys Rev E Stat Nonlin Soft Matter Phys ; 70(2 Pt 1): 021909, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15447517

RESUMO

Evidence is presented that adds to the debate surrounding the question: To what extent does neural control of cardiac output exploit noise? The transduction capability of cardiac afferent neurons, situated in and adjacent to the heart, is vital to feedback in control of cardiac function. An analysis of in situ cardiac afferent activity shows evidence of independent and exponentially distributed interspike intervals. An anatomical basis for such memoryless interspike intervals ultimately derives from the fact that each afferent neuron is associated with a field of sensory neurites, or bare nerve endings, that transduce local chemical and mechanical stimuli in a many-to-one fashion. As such, cardiac afferent neurons and their sensory neurite inputs are respectively modeled here by the Hodgkin-Huxley equations forced by "red" noise (decaying power spectrum) perturbing an otherwise constant subthreshold input. A variable barrier competition model is derived from these equations in order to address the question: How are noisy inputs being processed by sensory neurons to cause each spike? It is found that ion channels are responsible for significant input "whitening" (increased spectral power at higher frequency) through differentiation of the inputs. Such whitening is a means to distinguish low-frequency control signals from otherwise red noise fluctuations. Furthermore, spiking occurs when backward moving averages of the whitened inputs, over a window of the order of the sodium activation time scale, exceed an approximately constant barrier.


Assuntos
Biofísica/métodos , Coração/fisiologia , Neurônios Aferentes/fisiologia , Neurônios/metabolismo , Potenciais de Ação , Animais , Humanos , Modelos Neurológicos , Modelos Estatísticos , Modelos Teóricos , Probabilidade , Processos Estocásticos , Fatores de Tempo
3.
Neuromuscul Disord ; 11(6-7): 579-82, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11525888

RESUMO

Neuromuscular blocking agents are routinely used as an adjunct therapy for critically ill patients. Unlike many neuromuscular blocking agents, vecuronium does not cause significant histamine release, which may lead to bronchoconstriction. Due to a short duration of action and limited accumulation, vecuronium has been widely used. Prolonged ventilatory dependence due to persistent neuromuscular blockade has been reported in patients treated with vecuronium. We report a case of an 8-year-old girl who had a primarily motor axonopathy presenting with weakness after extended vecuronium administration with prolonged course of recovery. This primarily motor neuropathy with axonal features may be a variant of critical illness polyneuropathy, a rarely reported condition in pediatric patients.


Assuntos
Doença dos Neurônios Motores/induzido quimicamente , Doença dos Neurônios Motores/diagnóstico , Fármacos Neuromusculares não Despolarizantes/efeitos adversos , Polineuropatias/induzido quimicamente , Polineuropatias/diagnóstico , Brometo de Vecurônio/efeitos adversos , Criança , Eletromiografia , Feminino , Humanos , Doença dos Neurônios Motores/classificação , Condução Nervosa/efeitos dos fármacos , Polineuropatias/classificação , Recuperação de Função Fisiológica
4.
Phys Rev E Stat Nonlin Soft Matter Phys ; 63(4 Pt 1): 041911, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11308881

RESUMO

Regional cardiac control depends upon feedback of the status of the heart from afferent neurons responding to chemical and mechanical stimuli as transduced by an array of sensory neurites. Emerging experimental evidence shows that neural control in the heart may be partially exerted using subthreshold inputs that are amplified by noisy mechanical fluctuations. This amplification is known as aperiodic stochastic resonance (ASR). Neural control in the noisy, subthreshold regime is difficult to see since there is a near absence of any correlation between input and the output, the latter being the average firing (spiking) rate of the neuron. This lack of correlation is unresolved by traditional energy models of ASR since these models are unsuitable for identifying "cause and effect" between such inputs and outputs. In this paper, the "competition between averages" model is used to determine what portion of a noisy, subthreshold input is responsible, on average, for the output of sensory neurons as represented by the Fitzhugh-Nagumo equations. A physiologically relevant conclusion of this analysis is that a nearly constant amount of input is responsible for a spike, on average, and this amount is approximately independent of the firing rate. Hence, correlation measures are generally reduced as the firing rate is lowered even though neural control under this model is actually unaffected.


Assuntos
Coração/inervação , Neurônios Aferentes/fisiologia , Neurônios/patologia , Processos Estocásticos , Animais , Fenômenos Biofísicos , Biofísica , Modelos Neurológicos , Modelos Estatísticos , Rede Nervosa , Transmissão Sináptica , Fatores de Tempo
6.
Artigo em Inglês | MEDLINE | ID: mdl-11046466

RESUMO

Aperiodic stochastic resonance (ASR) is studied for a densely interconnected population of excitatory and inhibitory neurons that exhibit hysteresis. Switching between states in the presence of noisy external forcing is represented as a "competition between averages" and this is further explained through a semianalytical model. In contrast to energy-based approaches where only the timing of a switch between states is represented, the competition between averages also identifies the input history responsible for a switch. This last point leads to some interesting conclusions regarding cause and effect in the presence of noisy forcing of a hysteretic system. For example, at subthreshold inputs, it is found that the input history causing a switch between states is primarily dependent upon the noise level even though the corresponding time to switch is sensitive to both the distance from the threshold and the noise level. Since the application considered here is to cardiac neuronal control, control performance is considered over the full input range. Noise tuning for adequate control performance is found to be unnecessary if the noise level is high enough. This is consistent with studies of ASR for sensory neurons. Another observation made here that may be of clinical significance is that at higher noise levels, constraints placed upon inputs to ensure adequate control performance are likely to depend upon the switching direction.


Assuntos
Coração/inervação , Coração/fisiologia , Modelos Neurológicos , Miocárdio/citologia , Neurônios/fisiologia , Método de Monte Carlo , Processos Estocásticos , Fatores de Tempo , Pressão Ventricular/fisiologia
8.
IEEE Trans Biomed Eng ; 45(7): 942-5, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9644904

RESUMO

An electrocardiogram (ECG) compression algorithm based on a combination of the Karhunen-Loeve transform (KLT) and multirate sampling is introduced. The use of multirate sampling reduces KLT computational times to those reported for wavelet-packet-based compression techniques. A beat-by-beat quality controlled compression criterion is shown to be necessary to ensure clinically adequate reconstruction of each beat. The resulting quality controlled algorithm efficiently achieves compression rates of approximately 30-40:1 for the MIT-BIH database.


Assuntos
Algoritmos , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Controle de Qualidade
9.
Pediatr Neurol ; 16(3): 245-8, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9165518

RESUMO

We report the case of a severely hypotonic and weak term newborn who required ventilatory support from the time of birth. Serial neurophysiologic studies were consistent with severe demyelinating polyneuropathy. The infant's condition deteriorated over several weeks despite treatment with corticosteroids and intravenous immunoglobulin (IVIG) for presumed inflammatory demyelinating polyneuropathy. Histopathologic findings in a sural nerve biopsy, however, were similar to those previously reported in congenital hypomyelinating neuropathies. After 12 weeks of hospitalization and after discontinuation of corticosteroids, the patient began to recover and required no further ventilatory support. Remarkable improvement has continued for 18 months. This patient raises questions about the underlying mechanisms of hypomyelinating neuropathies in early infancy.


Assuntos
Doenças Desmielinizantes/fisiopatologia , Doenças do Recém-Nascido/fisiopatologia , Doenças do Sistema Nervoso Periférico/fisiopatologia , Corticosteroides/uso terapêutico , Biópsia , Doenças Desmielinizantes/patologia , Doenças Desmielinizantes/terapia , Feminino , Humanos , Imunoglobulinas Intravenosas/uso terapêutico , Recém-Nascido , Doenças do Recém-Nascido/patologia , Doenças do Recém-Nascido/terapia , Doenças do Sistema Nervoso Periférico/patologia , Doenças do Sistema Nervoso Periférico/terapia , Remissão Espontânea , Nervo Sural/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...